Applications include
• Control rooms
Based on the proven open path design,
• Personal refuge areas
• Turbine enclosures
Searchline Excel Cross-Duct was
Features & benefits
developed in response to the unique
• Fast speed of response provides
earliest warning
requirements for monitoring in HVAC
• High sensitivity allows low alarm set points
• Alignment free design makes
ducting and Turbine Enclosures.
installation simple
• Duct flex and vibration tolerance keeps
Searchline Excel Cross-Duct delivers the Cross duct flammable gas detectors
the system online
highest speed of response at low alarm compliment other system gas protectors
• Integral functional gas test facility allows
set points over a wide temperature range such as toxic gas detection, providing a fast
for simple system check
and effective protection to gas ingress into
• Contamination resistant optics reduce the
With continuous improvement and the highest ventilation ducts.
need for unscheduled maintenance
quality manufacturing and control processes,
• Immune to catalytic poisons
Honeywell Analytics Searchline Excel Open
• Works in inert atmospheres
Path flammable gas detector provides best in
class gas detection. Searchline Excel is often
the chosen primary flammable gas detector in
conjunction with Searchpoint Optima Plus as
complimenting flammable point detection.
Specification
Available Gas Calibrations Methane (gas mixtures where methane is the main constituent (>70%) and the balance is C2 - C6 hydrocarbons)*
Detection Range 0-100% LEL
Minimum Alarm Thresholds 20% LEL (>0.5 to 2.5m duct width) 10% LEL (>2.5m to 5m duct width)
Speed of Response T90 < 1 second
Output Signals Measuring range: 4-20mA sink or source (Default current source)
Over range: 21mA
Warning: 3mA
Beam Block: 2.5mA
Inhibit: 2mA
Fault: 0mA
Receiver: Receiver:
II 2 G Ex d IIC T5 (Tamb -40°C to +65°C) Gb Ex d IIC T5 (Tamb -40°C to +65°C) Gb
II 2 G Ex d IIC T6 (Tamb -40°C to +40°C) Gb Ex d IIC T6 (Tamb -40°C to +40°C) Gb
UL: Class 1 Groups B, C, D and Class 1 Zone 1 AEx d IIB +
Hydrogen (Amb -40°C to +65°C)
Heated Panel
ATEX: II 2 G Ex d IIC Gb T3 (Tamb -40°C to +60°C)
UL: Class 1, DIV 1, Groups B, C, D Tamb -40°C to +60°C
Path 0.5m - 5m
Heated
retro reflector
Mounting plate
Mounting cell
Transmitter
Receiver
Conduit
Terminal Box
Honeywell Analytics Gas Detection
Honeywell Analytics is able to provide gas detection solutions to meet the requirements of all
applications and industries. Contact us in the following ways:
Headquarters
Europe, Middle East, Africa Americas Asia Pacific
Life Safety Distribution AG Honeywell Analytics Distribution Inc. Honeywell Analytics
Javastrasse 2 405 Barclay Blvd. Asia Pacific
8604 Hegnau Lincolnshire, IL 60069 #701 Kolon Science Valley (1)
Switzerland USA 43 Digital-Ro 34-Gil, Guro-Gu
Tel: +41 (0)44 943 4300 Tel: +1 847 955 8200 Seoul 152-729
Fax: +41 (0)44 943 4398 Toll free: +1 800 538 0363 Korea
[email protected] Fax: +1 847 955 8210 Tel: +82 (0) 2 6909 0300
[email protected] Fax: +82 (0) 2 2025 0388
Customer Service:
India Tel: +91 124 4752700
Tel: +800 333 222 44 (Freephone number)
Tel: +41 44 943 4380 (Alternative number) [email protected]
Fax: +800 333 222 55
Middle East Tel: +971 4 450 5800 (Fixed Gas Detection)
Middle East Tel: +971 4 450 5852 (Portable Gas Detection)
EMEA: [email protected]
US: [email protected]
AP: [email protected]
www.honeywellanalytics.com
www.raesystems.com
Honeywell Analytics
Experts in Gas Detection
Please Note:
While every effort has been made to ensure accuracy in this publication, no responsibility can be accepted for errors or
omissions. Data may change, as well as legislation, and you are strongly advised to obtain copies of the most recently
issued regulations, standards, and guidelines. This publication is not intended to form the basis of a contract.