Mobile Call GSM Alarm System

Download as pdf or txt
Download as pdf or txt
You are on page 1of 28

Konlen Technology--The proffessional home alarm system provider

MOBILE CALL
GSM Alarm System

USER’
S MANUAL

Profile
For a better understanding of this product, please read this user
manual thoroughly before using it.

www.konlen.com

Downloaded from www.Manualslib.com manuals search engine


CONTENTS
Function Introduction 1-1
Alarm Host Diagram 1-4
Functions Settings 4-4
Initialization 4-4
Enter Settings 4-5
Exit Settings 5-5
Factory Reset 5-5
Coding of Remote Controller 5-6
Delete Remote Controller 6-6
Coding of Defense Zone 6-6
Delete Defense Zone 7-7
Change Password 7-7
Change Operation Password 7-7
Change Program Password 7-8
Clock Setting 8-8
Timing Settings 9-9
Timely Arm 9-9
Timely Disarm 9-9
Timing Control 10-10
Out Arm Delay Setting 10-10
Alarm Delay Setting 10-10
Alarm Number Setting 10-11
Delete Phone Number 11-11

Downloaded from www.Manualslib.com manuals search engine


CONTENTS
SMS Number Setting 11-12
Delete SMS Number 12-12
SMS Notification for Arm/Disarm 12-12

Defense Zone Programming 12-13


Home Arm Defense Zone Setting 13-13
Voice Recording 14-14
Siren Setting 14-14
Operation Instructions 15-15
System Status 15-15
Remote Controller Operate 15-15
Out Arm 16-16
Home Arm 15-15
Disarm 16-17
Answer Alarm Call 17-17
Remote Control 17-18
Emergency Help 18-18
System Dialing Function 18-18
Alarming Record Checking 18-19
GSM Signal Checking 19-19
Notes 20-20
Technical Parameters 21-21
Components List 22-22
Care and Maintenance 22-22

Downloaded from www.Manualslib.com manuals search engine


Function Introduction

ΚΜ
Function Instruction
7 wired and 99 wireless defense zones;
LCD screen with time clock display;
Voice prompt for all operations;
3 groups of timely arm and disarm;
Can store 6 phone numbers: when alarming, system will make alarm call
to these numbers automatically;
Can store 3 SMS numbers: when alarming, system will send alarming SMS
automatically;
10-second automatic message recording;
Built-in artificial intelligent digital voice announcer;
Built-in artificial intelligent English message;
Users can make calls by using keypad on alarm panel, just like a telephone;
One-key-control function: Out Arm, Home Arm, Remote Arm;
Arm/ disarm by SMS or call remotely;
SOS, fire, gas, door, hall, window, balcony, and boundary places alarm;
Real-time, delay, 24 hours, bypass defense zones programming function;
Wireless coding: easy to add additional wireless accessories;
Remote control Arm, Disarm, Monitor, and Intercom by phone;
SMS alert for power failure or recovery;
Built-in AAA NI-HI rechargeable battery: make alarm when power off.

ΚΜ
Alarm Host Diagram
In order to make the main unit get the wireless signal well for all wireless
accessories, please put the alarm host at the central place of your defense
area.
s away from large metal objects and house hold appliances
Make sure it’
which may cause high frequency interference, as well as barriers such as
reinforced concrete wall or fire door, etc.

1 Alarm Host Diagram


Downloaded from www.Manualslib.com manuals search engine
Alarm Host Diagram

Alarm Panel front schematic diagram:

Alarm Panel back schematic diagram:

Wired terminal block:

Speaker PIR Siren

2 Alarm Host Diagram


Downloaded from www.Manualslib.com manuals search engine
Alarm Host Diagram

1 LB- Positive of two-way speaker (red cable)

2 LB+ Negative of two-way speaker (black cable)

3 GND Ground

4 Z1 Wired sensor 1: support both NO and NC

5 GND Ground

6 Zone 2 Wired sensor 2: support both NO and NC

7 Zone 3 Wired sensor 3: support both NO and NC

8 GND GND

9 Zone 4 Wired sensor 4: support both NO and NC

10 Zone 5 Wired sensor 5: support both NO and NC

11 GND GND

12 Wired sensor 6: support both NO and NC


Zone 6
13 Zone 7 Wired sensor 7: support both NO and NC

14 SP- Negative of siren (black cable)

15 SP+ Positive of siren (red cable)

Note:

1. “LB -” and “LB +”are to connect external speaker. If you think


the internal speaker is not loud enough, pleasecontact us for
professional speakers.
2. Connect one cable of the wired sensor to GND and the other to
“Z1/Z2/Z3…/Z7”.
3. Please pay attention to the siren connection. Do not mix the two
cables together when connecting. Otherwise, it will damage the
transistor in the main panel.

3 Alarm Host Diagram


Downloaded from www.Manualslib.com manuals search engine
Alarm Host Diagram

LCD display:

ΚΜ
Functions Settings
1. Initialization
Please insert SIM card and plug in power adaptor, and then power on the
system, all the LED lights will be on for 2 seconds and you will hear a long
beep; the system comes into initialization. After the time clock displays on
the LCD screen, the [GSM] starts flashing and the main unit starts to detect
the GSM network until a long beep.
Then the [GSM] indicator goes out indicating the system comes into disarm
status.
Finally, turn on the backup battery switch.
2. Enter Settings
In the state of disarm, input 4-digit password by the keypad on the main
unit and press [ # ] button to confirm. You will hear a voice prompt: please
enter instruction. At the same time, [ SET ] indicator is on without flashing
and [0000] displays on the screen, indicating the system enters setting status.
You can perform different settings repeatedly as long as the system keeps in
setting status. The system will exit setting mode and return to disarm status
if you don’t press any keypad button for 40 seconds.

4 Functions Settings
Downloaded from www.Manualslib.com manuals search engine
Functions Settings

Note: In setting status, press can delete the numbers input.


The system default password is [8888].

Operating method: [ XXXX ] Ö [#]


X indicates the new 4-digit password.
LCD display:

3. Exit Settings
Press [ ] and [#] buttons, the main unit emits a long beep and exits settings.
*
The [ SET ] indicator goes out and the system returns to disarm state.
Ö
5VKXGZOTMSKZNUJ 澬澭澬#澭
*
4. Factory Reset
In disarm status, use keypad to input [95175308246] and press [#] to confirm,
all the LED indicators will be on for 2 seconds and you will hear a long beep.
The main unit gets all its settings cleared and restores to its factory settings
successfully.
Operating method: [95175308246] + [#]

5. Coding of Remote Controller


The remote controller has to be code to the alarm host in order to perform
normally.
In setup state, use keypad to input [20], input the remote controller number
[1~8], and then press [ # ] to confirm. The main unit emits a long beep and
you will hear “ remote control coding ”. The [ ] indicator is on without
flashing; press any button on the wireless remote controller, the main unit
makes a long beep and you will hear “coding completed”, [ ] indicator
goes out, indicating the remote controller succeeds in coding.
Operating method: [20] Ö [A] Ö [#]
A indicates: 1~8 remote controllers number.

5 Functions Settings
Downloaded from www.Manualslib.com manuals search engine
Functions Settings

You can add maximum 8 remote controllers.

LCD display:

6. Delete Remote Controller


‘t control the main unit after ‘s
The remote controller can it deleted.

In setup state, use keypad to input [21 ], then input the remote controller
number [1-8], and then press [ # ] to confirm. The main unit emits a long
beep and the [Signal] indicator flickers once. You will hear a voice prompt
“delete completed”.
Operating method: [21] Ö[A] Ö [#]
A indicates: 1~8 remote controllers number.

7. Coding of Defense Zone


Wireless detectors have to be coded to the main unit in order to trigger
it alarm.

In setup state, use keypad to input [23], input the defense zone number
you want to code [ 01~99 ], and then input [#] to confirm. The main unit
emits a long beep and the corresponding defense zone is displayed on
the screen. You will hear a voice prompt “detector coding”.
Then trigger a wireless detector to emit a wireless signal; after receiving
the signal, the main unit makes a long beep, and you will hear “coding
completed”, the [ ] indicator goes out at the same time.

Operating method: [23] Ö[XX] Ö[#]


XX indicates: 01 ~99 defense zones number
LCD display:

6 Functions Settings
Downloaded from www.Manualslib.com manuals search engine
Functions Settings

8. Delete Defense Zone


The wireless detector can’
t control the main unit after it’
s deleted.
In setup state, use keypad to input [24], then input the defense zone
number you want to delete [ 01~99 ], and then input [#] to confirm.
The main unit emits a long beep and the defense zone indicator
flickers once.
You will hear a voice prompt “delete completed”.
Operating method: [24] Ö [XX] Ö [#]
XX indicates: 01 ~99 defense zones number

9. Change Password
1). Change Operation Password
Operation password is the password used to disarm or remote control.
In setup status, use keypad to input [30], then input the 4-digit new
password, and then press [#] to confirm. The main unit will make a long
beep and you will hear a voice prompt “setting completed”.
Operating method: [30] Ö [XXXX] Ö[#]
XXXX indicates: the new 4-digit password
For example: change the system password to 1012
Operating method: [30] Ö [1012] Ö [#]
LCD display:

2). Change Program Password


Program password is the password you should input in order to setup
the system.

In setup status, use keypad to input [ 31 ], then input the 4-digit new
password, and then press [#] to confirm. The main unit will make a long
beep and you will hear a voice prompt “setting completed”.

7 Functions Settings
Downloaded from www.Manualslib.com manuals search engine
Functions Settings

Operating method: [31] Ö [ XXXX ] Ö [#]


XXXX indicates: the new 4-digit password
For example: change the system password to 2846
Operating method: [31] Ö [2846] Ö [#]

LCD display:

Note: the operation password and the programming password can not
be set as the same number.

10. Clock Setting


In setup status, use keypad to input [32], then input the last 2 digits [AA]
of the present year, the two digits [BB] of the month, the two digits [CC]
of the date, the two digits [DD] of the hour (24-hour system), the two
digits [EE] of the minute, the two digits [FF] of the second, and finally
enter [ # ] to confirm. You will hear a long beep and a voice prompt
“setting completed”.
Operating method: [32]Ö[AA]Ö[BB]Ö[CC] Ö[DD]Ö [EE]Ö [FF]Ö [#]
AA indicates: the last 2 digits of the present year
BB indicates: the 2 digits of the present month
CC indicates: the 2 digits of the present date
DD indicates: the 2 digits of the present hour
EE indicates: the 2 digits of the present minute
FF indicates: the 2 digits of the present second
For example: set the time as 15:35:40, Oct. 1st, 2009
Operating method: [32]Ö[09]Ö[10] Ö[01]Ö[15]Ö [35]Ö[40]Ö[#]

8 Functions Settings
Downloaded from www.Manualslib.com manuals search engine
Functions Settings

11. Timing Settings


1 ). Timely Arm
In setup status, use keypad to input [33~35], then input the hour [AA]
and minute [BB] of the time you want to set to arm, and finally input [#]
to confirm. You will hear a long beep and a voice prompt
“setting completed”.
Operating method: [XX]Ö [AA]Ö [BB]Ö[#]
XX indicates: the address code 33, 34, 35 of the timely arming
AA indicates: the hour of the setting time
BB indicates: the minute of the setting time
For example: set the arm time as 45’10pm
Operating method: [33] Ö[22]Ö[45]Ö[#]
LCD display:

2). Timely Disarm


In setup status, use keypad to input [36~38], then input the hour [AA]
and minute [BB] of the time you want to set to disarm, and finally input
[#] to confirm. You will hear a long beep and a voice prompt
“setting completed”.
Operating method: [XX]Ö[AA]Ö[BB]Ö[#]
XX indicates: the address code 36, 37, 38 of the timely disarming
AA indicates: the hour of the setting time
BB indicates: the minute of the setting time
For example: set the arm time as 55’7am
Operating method: [33] Ö[22]Ö[45]Ö[#]
LCD display:

9 Functions Settings
Downloaded from www.Manualslib.com manuals search engine
Functions Settings

3). Timing Control


In setup status, use keypad to input [39], then input the number indicating
turning on timely arm/ disarm [1/0], and then input [#] to confirm. You will
hear a long beep and a voice prompt “setting completed”. The factory
default is off.
Operating method: [39]Ö[0/1]Ö[#]
0: turn off the function of timely arm/ disarm
1: turn on the function of timely arm/ disarm
For example: turn on the function of timely arm/ disarm
Operating method: [39]Ö[1]Ö[#]
Time Setting for Out Arm Delay (Default: 60 sec)
In setup state, input the command: 44 + [XX] + #
XX indicates: the delay time of out arm; XX= 01-99: 1 sec to 99 sec
Note: The setting is effective only with the keypad operation.
The operation by remote controller or SMS is immediate arm without delay.

Time Setting for Alarm Delay (Default: 40 sec)


In setup state, input the command: 45 + [XX] + #
XX indicates: the delay time of alarm; XX= 01-99: 1 sec to 99 sec
Note: The setting is effective only when a zone is set as Alarm Delay Zone.
Note: Before the system enters arm or alarm status
it will emit a "Di" sound per second.

12. Alarm Number Setting


In setup state, input [ 51] ~ [ 56 ], then input the voice alarm-receiving
number (mobile number or telephone number), and then press [#] to
confirm. The main unit will make a long beep, the [Signal] indicator will
flicker once, and you will hear “setting completed” , which indicate
voice alarm-receiving number is set successfully.
Operating method: [XX]Ö[YY…YY]Ö[#]

10 Functions Settings
Downloaded from www.Manualslib.com manuals search engine
Functions Settings

XX indicates: the 1- 6 alarming user number [51] ~ [56]


YY….YY indicates: voice alarm-receiving phone number
For example: set 13811111111 as the first voice call number
Operating method: [51]Ö[13811111111]Ö[#]
LCD display:

13. Delete Phone Number


In setup state, input [51] ~ [56], and then press [#] to confirm, the main
unit will make a long beep and the [Signal] indicator will flicker once and
you will hear “delete completed”, which indicate the alarming user
number is deleted successfully.
Operating method: [XX]Ö[#]
XX indicates: the 1- 6 alarming user number [51] ~ [56]
For example: Delete the third alarming user number from the system.
Operating method: [53]Ö[#]
LCD display:

14. SMS Receiving Number Setting


SMS Receiving number means when system is alarming, it will only send
SMS to this mobile number. You can set maximum 3 SMS numbers.
In setup state, input [57] ~ [59], then input the SMS receiving number,
and then press [#] button to confirm. The main unit will make a beep, the
[Signal] indicator will flicker once and you will hear “setting completed”,
which indicate setup successfully.
Operating method: [XX] Ö[YY…YY]Ö[#]
XX indicates: address codes of message-receiving numbers from the first
group to the third group [57] ~ [59]
YY…YY indicates: the SMS receiving number

11 Functions Settings
Downloaded from www.Manualslib.com manuals search engine
Functions Settings

For example: setup 13822222222 as the first SMS receiving number


Operating method: [57]Ö[138222222]Ö[#]
15. Delete SMS Receiving Number
In setup state, use keypad to input [57] ~ [59], a nd then press [#] button
to confirm. The main unit will make a beep, the [ Signal ] indicator will
flicker once and you will hear “delete completed”, which indicate SMS
number is deleted successfully.
Operating method: [XX] Ö[#]
XX indicates: address codes of message-receiving numbers from the first
group to the third group [57] ~ [59]
For example: delete the first SMS user number from the system
Operating method: [57]Ö[#]
1).SMS Notification for Arm/Disarm (Default: OFF)
In setup state, input the command 77 + [1/ 0] + # (1: ON, 0: OFF)
After starting this function, the system can send SMS to three SMS receiving
numbers (57~59 as mentioned above) when the system enters arm/ disarm
status through wireless remote controllers or its panel keyboard operation.

16. Defense Zone Programming


If you want to change the alarm attribute of defense zone, such as turn
off the siren when system alarms, you can do it by defense zone
programming.
In setup state, first input [60], then the defense zone number [01~99],
then input defense zone type [1~4], then input defense zone location
number [1~8], and then select siren on/off [0/1], at last press [#] to
confirm. You will
hear the main unit emit a long beep and a voice prompt
“setting completed”.
Operating method: [60]Ö[AA]Ö[B]Ö[C]Ö[D]Ö[#]

12 Functions Settings
Downloaded from www.Manualslib.com manuals search engine
Functions Settings

AA: defense zone number [01~99] means zone 1 to zone 99;


B: defense zone type
[1]: real-time defense zone [2]: 40 seconds delay defense zone
[3]: 24 hours defense zone [4]: bypass defense zone
C: defense zone location
[1] SOS Alarm [2] Fire Alarm [3] Gas Leak Alarm
[4] Door Alarm [5] Hall Alarm [6] Window Alarm
[7] Balcony Alarm [8] Boundary Alarm
D: siren ON/OFF: [0] OFF, [1] ON
For example: set defense zone 12 to be 24-hour, fire alarm and siren on
Operating method: [60]Ö[12]Ö[3]Ö[2]Ö[1]Ö[#]

17. Home Arm Defense Zone Setting


If you want some detectors work and some do not, you can use
[Home Arm] function.
In setup state, use keypad to input [ 61 ], then choose the corresponding
defense zone number [01~99], then choose [ Home Arm], and then
choose whether alarm [0/1] button, and finally press [ # ] to confirm.
The main unit will make a long beep and a voice prompt
“setting completed”.
Operating method: [61]Ö[XX] Ö[A]Ö[#]
XX indicates: [ 01~99 ] is defense zone 1 to defense zone 99
A indicates: [0] Home arm but not alarm
[1] Home arm and alarm
For example: set defense zone 11 to be Home arm and alarm
Operating method: [61]Ö[11]Ö[1]Ö [#]
For example: set defense zone 12 as Home arm but not alarm
Operating method: [61]Ö[12]Ö[0]Ö [#]

13 Functions Settings
Downloaded from www.Manualslib.com manuals search engine
Functions Settings

18. Voice Recording


In setup state, use keypad to input [701], and then press [#] to confirm.
The main unit will emit a beep and the [ ] indicator is on, and after 10
seconds countdown, recording starts: record at 30cm away from the
main unit with moderate tone; 10 seconds later, the main unit will make
a beep indicating the recording stops and the recorded voice will replay.
Operating method: [701] Ö[#]
LCD display:

19. Siren Setting


In setup state, use keypad to input [75]; in the operation of arm/ disarm
by remote control, select if the siren sounds or not by [0/1] button, and
then press [#] to confirm. The main unit will emit a long beep and a
voice prompt “setting completed”.
Operating method: [75] Ö[A]Ö[#]
A indicates: [0] Siren off; [1] Siren on; System default: [0] Siren off
For example: set siren on when arm/ disarm
Operating method: [75] Ö[1] Ö[#]

LCD display:

20. Siren Setting in “Emergency Help” mode


In setup state, use keypad to input [76], and then [1/0], finally press [#]
to confirm. The main unit will make a long beep and a voice prompt
“setting completed”.
Operating method: [76]Ö[A]Ö[#]
A indicates:
[0]: siren off in “Emergency Help” mode
[1]: siren on in “Emergency Help” mode
System default: [0] siren off

14 Functions Settings
Downloaded from www.Manualslib.com manuals search engine
Functions Settings

ΚΜ
Operation Instructions
1. System status. There are 4 status as following
1). Arm: defense zone 1~99 will alarm when detectors are triggered
2). Home Arm: in arm status, the defense zone which is set as
[Home Arm] will alarm when detectors are triggered.
3). Disarm: defense zone 1~99 will not alarm when detector triggered
(except 24 hours defense zone)
4). System setup status: In this status, all defense zones will not alarm
when detectors are triggered.
2. Remote Controller Operation
Users can use remote controller to set system as Out Arm, Home
Arm, Emergency Alarm, Real-time Disarm and etc.

1). Out Arm: Press button


2). Disarm: Press button
3). Home Arm: Press button
4). Emergency Alarm: Press button, system will alarm at once.

3. Home Arm
It means, for the safety, while somebody is at home, you need to enable the
peripheral door, window, balcony and boundary detectors of the alarm
system while prevent from triggering the indoor detectors, which may
cause improper warning; then, you shall select Arm at Home, let just
part of the detectors work and disable the other parts.

Main Unit Operation: Press [At Home ] button on keypad


Remote Control Operation: Press [ ] button on remote controller
LCD display:

15 Functions Settings
Downloaded from www.Manualslib.com manuals search engine
Functions Settings

4. Out Arm
It means to guard all around your house while everyone is going out;
all the detectors of the host are always working; when the detector is
triggered by detecting source (anti-theft, fire prevention, gas leak, etc.),
the alarm system will sound the alarm.
Press [Out Home ] button on keypad, system will make a beep per
second and totally 100 beeps. The [OUT ARM] indicator will be on
without flashing. It means Out Arm is set successfully.
Arm Operation: Press [Out Home ] button, the system will enter arm
status 100 seconds later.
LCD display:

You can also set out arm by SMS remotely. The SMS command is: Remote
Control Password (Default: 1234) + [1]
After the setting, the host makes a "Di" sound, ARM LED is on and you will
receive a SMS: System armed.
5. Disarm
It means to stop the alarm when the main unit sounds the alarm or make
the alarm system in the state of non-warning. After disarming, even if you
trigger the detector, the main unit would not sound alarm (excluding
24-hour defense areas).
Use keypad to input system password, then press [#] button. [Out Home]
or [At Home] lights will be off. It means disarm setting successful.
Remote Control Operation: Press [ ] button on remote controller
Main Unit Operation: input system password + [#]
LCD display:

You can also set disarm by SMS remotely. The SMS command is: Remote
Control Password (Default: 1234) + [2]

16 Functions Settings
Downloaded from www.Manualslib.com manuals search engine
Functions Settings

After the setting, the host makes "Di" Di" sound, ARM LED is off and you
will receive a SMS: System disarmed.
Note: If you send arm or disarm SMS by the mobile phone number stored
in the system before (refer to “SMS Receiving Number Setting), you will
receive two arm/disarm SMS.

6. Answer Alarm Call


When the main unit sounds alarm, it will dial the preset numbers. If no one
answers the call, the system will call the next user number automatically.
The system will call each preset numbers for 3 times in order.
If you answer the call, you will hear the pre-record voice. You can set system
via your telephone or mobile phone keypad.
If you hang-up directly without answering the call, the system will call each
preset number for 3 times circularly.
Press [*]: Read the alarm information.
Press [1]: Main unit stops alarming and Arm; it stops calling users.
Press [2]: Main unit stops alarming and Disarm; it stops calling users.
Press [3]: Siren off and monitors the scene for 30 seconds; for continued
monitoring, press [3] again to monitor for another 30 seconds.
Press [4]: Main unit starts a 30-second two-way intercom. It cannot be
controlled by the mobile during the time of intercom.

7. Remote Control
Dial the number associated to the alarm main unit by phone (mobile
phone ), and after one ringing cycle, you can hear a voice prompt
“Please enter password”. If the password is right, you will here
“Press 1 to arm, Press 2 to disarm, Press 3 to Monitor, Press 4 to
Intercom”. If the password is wrong, you will hear a prompt voice
“wrong password, please re-enter”.

17 Functions Settings
Downloaded from www.Manualslib.com manuals search engine
Functions Settings

Press [1]: arm, if finished successfully, you will hear a voice prompt
“System armed”.
Press [2]: disarm, if finished successfully, you will hear a voice prompt
“System disarmed”.
Press [3]: monitoring for 30 seconds, to continue monitoring, press [3]
again to monitor for another 30 seconds.
Press [4]: two-way intercom for 30 seconds. You can’t operate the main
unit during this time.
8. Emergency Help
Press [Emergency ] button on keypad, or [ ] button on remote controller
or wireless panic button, the main unit will alarm and make call to the preset
user numbers.

9. System Dialing Function


In disarm status, you can use the main unit to make any call just like a
land-line telephone. Dial telephone number on keypad, press [ ] button,
the main unit will make a beep and the [ Signal ] indicator will be flashing.
After the call, press [ ] button again, the main unit will be in disarm status.

10. Alarming Record Checking


In disarm state, input [*0#], then the main unit will make a long beep and
enters the state of alarm record checking. After displaying the alarm and
defense zone number indicator, the LCD screen will display the exact
alarming time of this defense zone. Press 2, you can upturn to check the
previous alarming record; press 8, downturn to check; and press [*#]
to exit checking.

18 Functions Settings
Downloaded from www.Manualslib.com manuals search engine
Functions Settings

For example: the 51st defense zone; the 7th alarming; alarming time: 12:10,
August 1st, 2008. LCD display for one second, and then display the alarming
time:

You can also check the alarm records by SMS ( Max: Latest 9 records).
SMS Check Command: Remote Control Password (Default: 1234) + [3]
Reply SMS:
Eg: Alarm record:
NO1 Zone: 05 TIME: 11-06-25 11:37
(It indicates the first record: wireless zone 5 alarm time)…………….
NO9 Zone: 19 Time: 11-06-25 11:45
(It indicates the first record: wireless zone 19 alarm time)
11. GSM Signal Checking
Before installing the main unit, you should check the signal of the installing
place in order to ensure the unit can perform well. In setup state, input
[81]Ö #, the main unit will make a long beep and display 00 + XX ( XX
indicate s the intensity of the signal). And the intensity should be within
the range of 07-31; if it’s less than 07, you should change place.
For example: if the signal intensity is 12, it will display as:

[Notes:]
Only under Out Arm status, the system has the function of sending SMS
alert for power failure/ power recovery. While in Disarm or Home Arm
status, it does not.
The SMS content:
Power failure: Power charger off
Power recovery: Power charger on

19 Functions Settings
Downloaded from www.Manualslib.com manuals search engine
Technical Parameters

[ Technical Parameters ]
List 1:
Input Voltage DC12V/1A
Standby Current <55mA
Alarming Current <450mA
Wireless Frequency 3.`6:+<3œ
GSM Frequency 900/ 1800/ 1900MHz
Back-up Battery NI-HI AAA*6 DC7.2V
Siren Volume 110dB

List 2:
Defense Zone Arm Home Arm Type Alarm Information Siren
Zone 1 effective invalid real-time Door alarm yes
Zone 2 effective invalid real-time Hall alarm yes
Zone 3 effective effective real-time Window alarm yes
Zone 4 effective effective real-time Balcony alarm yes
Zone 5 effective effective 24 hours Fire alarm yes
Zone 6 effective effective 24 hours Gas alarm yes
Emergency
effective effective 24 hours Emergency alarm no
button
Zone 7-99 effective invalid real-time Emergency alarm yes
Wired defense
effective invalid real-time Emergency alarm yes
`UTKͧͨ

Operation Password 8888 Remote control On

Remote control Password 1234 Siren Off


Siren sound time 180sec Home Appliance Optional

20 Technical Parameters
Downloaded from www.Manualslib.com manuals search engine
Components list

[Components list ]
Main panel 1pc Remote controller 2pcs
Siren 1pc PIR sensor 1pc
Door sensor 1pc Power adapter 1pc
User manual 1pc

[ Care and Maintenance ]


The alarm system has excellent design and uses advanced technologies.
It shall be used with care. The following suggestions are required to
maintain your obligations under the warranty terms, and for prolonging
the service life of the system.
Place the control panel and all parts and accessories out of children’s
reach.
Keep the alarm system dry. Rain, humidity and various fluids or moisture
all will corrupt the electronic circuit.
Do not use or place the alarm system in dirty locations,otherwise the
electronic elements will be damaged.
Do no place the system in excessively hot locations.
High temperature will shorten t he service life of electronic equipment,
damage batteries, deform or even melt some plastic parts.
Do not place the system in excessively cold locations.
Other wise condensation many occur and damage the
circuit board of the alarm system.
It is recommended that you check and test the alarm
system periodically:

21 Care and Maintenance


Downloaded from www.Manualslib.com manuals search engine
Care and Maintenance

Check the main unit every three months:

1. Whether it can arm/disarm normally;


2. Whether it can dial the number for alarm normally;
3. Whether it can receive wireless detectors’signal normally;
4. Whether the back - up battery can work normally.

Check the wireless detectors once a month:

1. Trigger wireless detectors to see if system can alarm normally;


2. Check all detectors’ batteries to see if it’
s in low voltage;
3. Check whether wireless detectors can send signal to the main
unit normally.

Check the SIM card:

1. Check the use of SIM card, such as network signal, balance, etc.
2. Make sure the PIN code verification of the SIM card is closed.
3. Please keep the password and SIM card number safe, in case that
other people remote control the system illegally.
Since the alarm system is continuously in operation or standby mode,
the supply adaptor of the control panel shall be connected to a safe
and reliable socket.
Do not place the system near your bedroom or office table, because the
siren will make high-loudness sound in the case of alarm, which may
adversely affect your rest or work.
If the alarm system will not be used for a long time, please disconnect the
system from the power supply.
Please do not disassemble, repair or alter the products without permission,
or it may cause accidents and faults.

22 Care and Maintenance


Downloaded from www.Manualslib.com manuals search engine
Care and Maintenance

Do not drop this product on the ground or on hard objects, as it may lead
to massive impact to cause faults and damages.
Without approval and consent of relevant authorities, please do not set
“110”, “119” or the alarm phone number of police station for this
main unit.
Please read the suggestions above carefully and follow the instructions
herein. If any of the equipment does not work properly, please send it to
the dealer or authorized service point for repair. We will try our best to
solve the problem for you as soon as possible.

The Following Sensors Are Optional

23 Care and Maintenance


Downloaded from www.Manualslib.com manuals search engine
Care and Maintenance

Optional sensors/detectors are packed separately. They include remote


controller, outdoor siren, transmitter, wireless PIR, wireless gap sensor,
wireless gas detector, wireless smoke detector, panic button, baluster,
etc. You can choose according to your specific requirements.

24 Care and Maintenance


Downloaded from www.Manualslib.com manuals search engine
MOBILE CALL

2011.12.V2.0 GSM Alarm System

Downloaded from www.Manualslib.com manuals search engine

You might also like