0% found this document useful (0 votes)
875 views8 pages

20-HIM-A3, 20-HIM-A5 Programming Guide

This document provides instructions for programming PowerFlex drives using an external Human Interface Module (HIM). It describes: 1. The keys on the HIM including ESC, Select, arrows, Enter, Start, Jog, Stop, and their functions for navigating menus and changing parameter values. 2. The ALT key which provides secondary functions for other keys like displaying languages or removing the HIM without faulting the drive. 3. Examples of using the ALT key to access the S.M.A.R.T menu, view parameter values, toggle manual control, and remove the HIM safely. The document instructs the user on navigating the HIM interface using the keys to

Uploaded by

Sultan Alhammadi
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
875 views8 pages

20-HIM-A3, 20-HIM-A5 Programming Guide

This document provides instructions for programming PowerFlex drives using an external Human Interface Module (HIM). It describes: 1. The keys on the HIM including ESC, Select, arrows, Enter, Start, Jog, Stop, and their functions for navigating menus and changing parameter values. 2. The ALT key which provides secondary functions for other keys like displaying languages or removing the HIM without faulting the drive. 3. Examples of using the ALT key to access the S.M.A.R.T menu, view parameter values, toggle manual control, and remove the HIM safely. The document instructs the user on navigating the HIM interface using the keys to

Uploaded by

Sultan Alhammadi
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 8

Programming PowerFlex Drives (70, 70EC, 700Std, 700VC Series A & B)/ SMC Flex

Soft Starters with 20-HIM-A3 or 20-HIM-A5 External Door Mounted HIM


Direction Drive Status Alarm Auto/Man Information (The ALT View Function is allowed)

This is the “User Display” Window – The drive


typically defaults to this window after 30 seconds

This is User Display Line 0

This is User Display Line 1

This is User Display Line 2

Blue Programming Keys

Programming Instructions shown using a 20-HIM-A3


Key Descriptions
Escape
ESC Pressing the Escape Key once takes you back one level.

Select
Sel
When at the parameter level pressing select will move the cursor to the line of the
Display where the parameter value is. Then you are able to change its value. If the value
of the parameter is at a Bit level then repeatedly pressing the Select key will move the
cursor from one bit to the next (going from right to left).

Up and Down Arrows


Allows you to move between the different levels in the menu. When changing the
parameter value these will increase or decrease the value. The longer you hold down the
key the faster it changes the value.

Enter (This is the Universal key/Symbol used for “Enter”)


Pressing this key will select the Item Highlighted in the menu and take you to the
next level. Pressing this key when the value of a parameter has been changed will
then write the changed value to the drive.

1
Key Descriptions continued
Programming Instructions shown using a 20-HIM-A3

Key Descriptions
Start
| Pressing Start will cause the Drive Output/Power IGBT’s to start modulating or put the
drive in a run condition. If no start inhibit is present, Mask, fault or alarm. If a digital input
is programmed for 2 wire control. The Start Button is disabled unless P192 Bit 1 = 1.
Once started the STS LED should be solid Green.

Jog
Jog From a stopped state press and HOLD Jog – this causes the Drive Output /Power
IGBT’S to start modulating and follow the speed reference of P100 Jog1. If no start inhibit
is present, Mask, fault or alarm. When the Jog Key is released - Then the Drive Output/
Power IGBT’s will stop modulating and the Drive will be in a stopped condition.

Backspace
Pressing Backspace will delete / remove the text immediately to the left of the cursor.

Stop
O Pressing stop will do one of the following based on P155 or P156 setting: Coast, Ramp,
Ramp to Hold, DC Brake or Fast Brake. If a fault is displayed and is resetable pressing
and releasing the stop key will clear the fault – when P241 is enabled.

2
Key Descriptions continued
Programming Instructions shown using a 20-HIM-A3

Key Descriptions
Change Direction
Pressing the change direction key will cause the Drive/Motor to go in the opposite
Direction. Unless a mask is set to lock out this function. Or reverse disable P190

Digital Pot Up and Down Arrows

When the HIM is used as the speed reference. Either Press and hold or press and
Release repeatedly the Up/Down arrows. Will Increase/Decrease the speed.

The Numerical Numbers can be utilized to increase or decrease a


7 8 9 Parameter Value – when at a Parameter. When at the User display
window - these keys can be used to enter a speed reference. When the
4 5 6 HIM is selected as a speed reference.
1 2 3
0 Decimal Point (500.20, 5.34, and 0.12 etc…)
. (Allows you to use a fractional value)
Changes a Parameter value to a Positive or Negative
+/- Key Descriptions continued

3
Key Descriptions
ALT (using the ALT Key)
ALT
The ALT key is Color coded Yellow for 2nd function. This means whenever the ALT Key is
Pressed and Released the Keys that are labeled in Yellow text that is their 2nd function
And are now available to be selected within a 3 sec time frame. (See below for details).
Note: For the list below typically you will be at the “User Display” window.
(If after pressing ALT and the 2nd Function Key - nothing happens – then Press the ESC Key once.)
(Then follow the prompts in the display)
2nd Function S.M.A.R.T
S.M.A.R.T Pressing and Releasing the ALT key and then within Approximately 3 sec Press and
ESC Release the Blue ESC key Displays the “S.M.A.R.T ” Start-up menu.

View 2nd Function View (At the “User Display” window)


Displays only the Top Line of the display and an oversized Display line 1
Sel
2nd Function View (You must be at the “Main Menu” with “Parameter” Highlighted)
View Pressing and Releasing the ALT key and then within Approximately 3 sec Press and
Sel Release the Blue Sel key displays the “Parameter” Sub menu

2nd Function Lang


Lang
Pressing and Releasing the ALT key and then within Approximately 3 sec Press and
Release the Blue UP Arrow key displays the Language Selection menu
2nd Function Auto / Man (Providing or Removing Manual control with the HIM)
Auto / Man Pressing and Releasing the ALT key and then within Approximately 3 sec Press and
Release the Blue Down Arrow key Attempts to provide or remove Manual control

2nd Function Remove


Remove Pressing and Releasing the ALT key and then within Approximately 3 sec Press and
Release the Blue Enter key this Allows HIM removal without causing a fault (if the HIM is
not the last controlling device or does not have manual control of the drive).
Press and Release ALT and then P. and R. (.) Press and Release ALT and then P. and R. (+/-)
A Value can be entered as an Exponent Displays the Parameter Menu
. (Not available on PowerFlex 700) +/- For Viewing / Editing Parameters.
2nd Function Exp nd
Param # 2 Function Param#
Exp
ALT / 2nd Function Examples

4
Press and Release

ALT Alternate (ALT) This is displayed for


Key is Active Approximately 3 seconds

Press and Release


ALT
SMART List:
Then Digital IN2 Sel
Stop/Brk Mode A
Press and Release
Minimum Speed
S.M.A.R.T
ESC
Displays the “S.M.A.R.T” Start-up menu.
(Starting At the “User Display” window)
Press and Release
ALT

0.00
Then
Press and Release
View
Sel

Provides a Magnified view


Amps
of the User Display line 1

Press and Release

ALT
English?
Then Français?
Press and Release ¿Español?
Italiano?
Lang

Displays the Language menu.

ALT / 2nd Function Examples Continued

5
Press and Release
ALT
Auto Manual
Go to HIM Manual
Then Speed Control?
Press and Release Press Enter ()
Auto / Man

(To toggle between HIM and Auto control of the Drive – when using the HIM)

Press and Release


ALT
Remove HIM
Do you wish to?
Then
To Continue
Press and Release Press Enter ()
Remove

Allows HIM removal without causing a fault if the HIM is not actively controlling the drive/motor
with logic commands (the only one Selected in the Logic mask) or providing a speed reference

Press and Release


ALT
Param #: 1
Then
Output Freq
Press and Release
0.0 HZ
+/-
Param #

Allows entry of a parameter number for viewing/editing

ALT / 2nd Function Examples Continued


(At the “Main Menu” with “Parameter” Highlighted)

6
Press and Release
ALT Param Dspy Item:
File Group Par
Then
Press and Release Numbered List
View Changed Params
Sel

Provides the selection of how parameters will be viewed and continued to be viewed this way
even when AC power has been cycled.
Programming Instructions shown using a 20-HIM-A3
Programming/Changing Parameters
ESC
ESC Sel
Sel
Escape Select UP Down Enter

Starting At the “User Display” window

Press and Release


ESC
Then

This window will be displayed


This is the Main Menu: and has the
following Selections in its list:
Main Menu:
Diagnostics
0.00 HZ Parameter
Device Select
Main Menu: Memory Storage
Diagnostics Start-Up
Preferences
Parameter
These Selections will be explained in
Device Select
greater detail – in the following pages /
Menu Structure
Programming/Changing Parameters
ESC
ESC Sel
Sel
Escape Select UP Down Enter
Note: Changing Parameter 196 to a value of “1 Advanced” – allows access to all Parameters.
7
Press and Release
ALT

Then
Press and Release
View
Sel
Then
This window will be displayed

Use the Up and


Down Arrows to
Highlight
Numbered List
Then Press the
Enter Key
Then
This window will be displayed Then Press Enter and this window will be displayed

Key in any parameter number you want to go to - then Press and Release the Enter key. This will
take you to that parameter. Then you can Press and Release the Sel Key – Now you are able to
change the value of the parameter -with the Up/ Down Keys or the Numerical Keys – once the value
is changed -then you must Press and Release the Enter Key to write the change into the drive. Then
you can key in the next parameter or Press and Release the Esc Key to go back to any previous
Menu/Display.

Note: Changing Parameter 196 to a value of “1 Advanced” – allows access to all Parameters.