0% found this document useful (0 votes)
42 views

Assignment 1

1. Formulate the Y-bus matrix for the 4-bus power system shown using the singular transformation method, with bus 1 as the reference bus. 2. Formulate the Y-bus matrix for the 4-bus power system shown using the singular transformation method, accounting for line and generator reactances and half line charging admittances. 3. Formulate the Y-bus matrix for the 3-bus power system shown under three cases: (a) without line 2-3, (b) the effect of adding line 2-3 with no mutual coupling, and (c) adding line 2-3 with a mutual impedance of j0.01 pu to line 2-3(

Uploaded by

Kunal Bhargude
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
42 views

Assignment 1

1. Formulate the Y-bus matrix for the 4-bus power system shown using the singular transformation method, with bus 1 as the reference bus. 2. Formulate the Y-bus matrix for the 4-bus power system shown using the singular transformation method, accounting for line and generator reactances and half line charging admittances. 3. Formulate the Y-bus matrix for the 3-bus power system shown under three cases: (a) without line 2-3, (b) the effect of adding line 2-3 with no mutual coupling, and (c) adding line 2-3 with a mutual impedance of j0.01 pu to line 2-3(

Uploaded by

Kunal Bhargude
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 5

Course : PSA

Topic: Power Flow Analysis

Due Date: 11 October 2022


1. For the power system network shown in g 1, formulate

Y-bus by singular transformation method. The self and mutual


impedances in pu are indicated in the gure. Take bus-1 as
reference.

3 4

j 0.35

jo 3 Jo o
50.2 jo 25

2 jo 3 1

Figure: 1

2. For the power system network shown is gure 2, obtain Y-bus by


singular transformation method. The reactance of each line is 0.01
pu and that of the generator is 0.05 pu. Each line has a half line
charging admittance of 0.05 pu.

G N N
92

1 3 2

Figure: 2

3. Figure 3 Shows a 3- bus power system transmission network.


The line impedances are given below:

Formulate Y - bus for the following cases:

(a) Assume that the line shown dotted between Bus-2 and B-3 ,
that is line 2- 3(2) is not present.

(b) Discuss which element of Y-bus obtained in case (a) are


a ected when the dotted line 2-3(2) is connected. The new line has

no mutual coupling with other lines.

(c) Obtain the modi ed Y-bus when line 2-3(2) which has a mutual

impedance of j0.01 pu with line 2-3(1) is connected.

2 3

1 CReference

Figure: 3

4. Consider a 2-bus system shown in gure 4. The loads at the


buses are shown in the gure. The Y-bus of the network is
· ¸
1:72\ ¡ 70 1:8\110

Ybus =

1:8\110 1:72\ ¡ 70

Assume at start. Use second iteration value of V2 to calculate

injected power at bus-1.

I
1.2 504

0.5 10.2
Figure: 4

5. For a 3-bus system, the line and bus data are as follows:

1:04\0

All values are in pu. Compute bus voltages at buses 2 and 3


at the end of second iteration. Use acceleration factor of 1.6.

Use at start.

6. For the network shown in gure 5, obtain the complex bus bar
voltage at bus 2 at the end of the rst iteration using fast
decoupled method.

V1 = 1:0\0±

P2 + j Q2 = ¡5:96 + j1:46

jV3j = 1:02; P3 = 2 pu

0 04 5005 0 02 5003

G G

I 2 3

Figure: 5

7. For a given power system in gure 6, determine voltages at


buses 2 and 3 by N-R method after one iteration.

NO 5 51.0 pu

j 0.5 jo 4

j 0.4

3 I V 1 04200

vi stjo 6 pu