The document discusses five high-volume air sampling systems from HI-Q Environmental Products Company designed to meet EPA standards for collecting PM-10 particles smaller than 10 micrometers from ambient air. The systems feature size-selective inlets to sample air at 40 CFM and include enclosures, filter holders, timers, and calibrated brushless or brushed blowers powered by 115 or 230 VAC. A variety of options are available including additional filters, tubing, cabinets, and continuous monitoring equipment.
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0 ratings0% found this document useful (0 votes)
57 views1 page
Hvas PM 10
The document discusses five high-volume air sampling systems from HI-Q Environmental Products Company designed to meet EPA standards for collecting PM-10 particles smaller than 10 micrometers from ambient air. The systems feature size-selective inlets to sample air at 40 CFM and include enclosures, filter holders, timers, and calibrated brushless or brushed blowers powered by 115 or 230 VAC. A variety of options are available including additional filters, tubing, cabinets, and continuous monitoring equipment.
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1
HI-Q
Outdoor Hi-Volume Air Samplers
PM10-Series PM-10 Size Selective High Volume Air Sampling Systems
• Complete Systems Designed to Meet or Exceed U.S. EPA Federal
Reference Method Performance Specifications for PM-10 Sampling • Three High Performance Systems to choose from • Brushless & Brushed Motor Driven 2 & 3-Stage Blowers Available • NIST Traceable Flow Calibration The EPA Clean Air Act of 1990 established a measuring standard to evaluate and monitor the health effects of thoracic inhaleable particles. The standard was set that in order for an environment to be healthy, in terms of these particles, it must have a concentration of less than 50 µg/m3 of particles with aerodynamic diameters less than 10 microns. The standard has been deemed PM-10, particulate size of 10um. Adherence to this standard is most important in industries and environments which produce a large mass of PM-10’s such as mills, mines, and biomedical facilities. HI-Q Environmental Products Company Ordering Information offers five complete PM-10 sampling systems designed to meet or exceed U.S. EPA Federal Ref- PM10-5300AFC (3-Stage) & PM10-5200AFC (2-Stage) erence Method performance specifications for the Automatic/PID Mass Flow Control, PM10 HI-Vol Air Sampling System, 115 collection of PM-10 in ambient air. Each of the five VAC, with PLC controlled 3 or 2 Stage Brushless Blower. Date logs to systems incorporates the same size selective inlet Micro-SD Card in .csv format. Unit includes 8” x 10” filter paper holder, 8” mounted on top of any of HI-Q’s five High Volume, x 10” paper cartridge and PM-10 Size Selective Inlet. Standard Units are Outdoor, TSP Air Sampling Systems depicted on SCFM. See HVP-5300/5200AFC Series samplers for complete description the previous pages. The inlet is designed to sample & available options. at a flow rate of 40 CFM. PM10-4300AFC (3-Stage) & PM10-4200AFC (2-Stage) Automatic/PID Mass Flow Control, PM-10 HI-Vol Air Sampling System, 115 Motor/Pump: PM10-5300AFC: Brushless, Electronic Control/3-Stage. VAC, with PLC controlled 3 or 2 Stage Brushless Blower. Unit includes 8” PM10-5200AFC: Brushless, Electronic Control/2-Stage. x 10” filter paper holder, 8” x 10” paper cartridge and PM-10 Size Selective PM10-4300AFC: Brushless, Electronic Control/3-Stage. Inlet. Standard Units are SCFM. See HVP-4300/4200AFC Series samplers PM10-4200AFC: Brushless, Electronic Control/2-Stage. for complete description & available options. PM10-3300BRL: Brushless, Mechanical Control/3-Stage. PM10-3000BRL: Brushless, Mechanical Control/2 Stage. PM10-3300BRL (3-Stage) & PM10-3000BRL (2-Stage) PM10-2000: Brushed, Mechanical Control/2-Stage. Manual Speed Control, Brushless 3 or 2 Stage Blower, PM-10, High Vol Housing: Anodized Aluminum Outdoor Shelter with lockable control Air Sampling System. 115VAC. Unit includes 8”x10” filter paper holder, 8” panel door. See HI-Q’s HVP-2000 & PM10-HEAD for overall x 10” paper cartridge and PM-10 Size Selective Inlet. Standard Units are cabinet & Size Selective Inlet dimensions. ACFM. See HVP-3300/3000BRL Series samplers for complete description Calibrated Flow Range: 10-50 CFM (CMM unit calibration upon request). & available options. NIST Traceable Calibration. PM10-2000 Unit Net Weight: ~50 lbs. Cabinet Weight (avg.). 44 lbs. Size Selective Inlet. Manual Speed Control, Brushed Motor Blower PM-10, HI-Vol Air Sampling Shipping Weight 20” x 20” x 50” @ 58 lbs. Cabinet Carton (avg.). System. 115 VAC. Unit includes 8” x 10” filter paper holder, 8” x 10” paper & Dimensions: 32” x 32” x 26” @ 52 lbs. Size Selective Inlet Carton. cartridge and PM-10 Size Selective Inlet. Standard Units are ACFM. See PM10-3-Stage 115 VAC, 50/60 Hz.,10 Amp, 800 Watt HVP-2000 Series samplers for complete description & available options. Power Specifications: 230 VAC, 50/60 Hz., 10.5 Amp, 1200 Watt PM10-2-Stage 115 VAC, 50/60Hz., 5.0 Amp, 250 Watt PM10-5300AFC/230,PM10-5200AFC/230,PM10-4300AFC/230, PM10- 4200AFC/230,PM10-3300BRL/230, PM10-3000BRL/230, & PM10-2000/230 are Power Specifications: 230 VAC, 50/60Hz., 5.0 Amp, 400 Watt the 230 Volt versions of units described above. PM10-2000 115 VAC, 50/60Hz., 9.0 Amp, 300 Air Watts Power Specifications: 230 VAC, 50/60Hz., 4.6 Amp, 269 Air Watts Options: Elapsed Timer: Electronic, Resettable Hours & Tenths of Hours, 7DAYTMR EXHAUST-10 (all units) LCD read out, 5 year internal battery. Mechanical 7 Day Skip Timers 10’ Exhaust Tubing Flow Totalizer: Resettable Standard Cubic Feet 7DAY-ELCTMR HIQ-6009 (PM10-4300& 4200 only) (total volume in cubic meters or liters upon request) Programmable Electronic Timer Silicone Release Spray Flow Display: Standard Cubic Feet per Minute for shim plate HVP-PR4-3 (PM10-4300 & 4200 only) (SCCM or SLPM display upon request) Continuous Flow/Pressure Recorder 810-CARTRIDGE Flow Calibrator: See Air Flow Calibrators Additional 8”x10” HVP-CAB-STBLZRS paper cartridge Filter Media: See Filter Media For Air Sampling Section Cabinet Stabilizer Set Optional Equipment: See “Options” listed above & Air Sampling Accessories
7386 Trade Street / San Diego, CA 92121 / Phone 858-549-2820 / Fax 858-549-9657 / www.HI-Q.net 7