Solar Pump Excel Computation

The Mabuhay Solar Pump Irrigation Project aims to provide 0.02029 cubic meters per second or 321.60 gallons per minute of water for 6 hours per day from a source 10.46 meters above and 60 meters from the pumphouse. The total dynamic head is calculated to be 36.28786 feet or 11.06 meters based on the vertical distance and estimated friction head loss through plastic piping. The project aims to find a submersible solar pump that can meet the required discharge rate against this total dynamic head.

Uploaded by

mary joy Panama
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
242 views3 pages

Solar Pump Excel Computation

The Mabuhay Solar Pump Irrigation Project aims to provide 0.02029 cubic meters per second or 321.60 gallons per minute of water for 6 hours per day from a source 10.46 meters above and 60 meters from the pumphouse. The total dynamic head is calculated to be 36.28786 feet or 11.06 meters based on the vertical distance and estimated friction head loss through plastic piping. The project aims to find a submersible solar pump that can meet the required discharge rate against this total dynamic head.

Uploaded by

mary joy Panama
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
You are on page 1/ 3

Name of Project: MABUHAY SOLAR PUMP IRRIGATION PROJECT

Location:
Implementing office:

Data:
Required Discharge (Q): 0.02029 cu.m/s
321.60 GPM
Design hours of Pumping:
9 :00 Am
3 :00 Pm
6.00 Hours
360 minutes
Total Required Discharge per day=
115,776.93 Gallons
TOTAL DYNAMIC HEAD =Vertical Head + Effective Additional Head due to Pipe Friction

A.Source to Pumphouse-1
Vertical Distance= 10.46 m 34.31926 ft
Horizontal Distance= 60 m 196.86 ft

Friction Head Loss  (in feet per 100ft plastic pipe)


Nominal Pipe Diameter
GPM 3/8” ½” ¾” 1” 1 ¼” 1 ½”
1 3.3 1.1 0.3 x x x
1 11.8 3.8 1 0.3 0.1 x
3 42.5 13.7 3.5 1.1 0.3 0.1
4 62.2 20.7 5.3 1.6 0.4 0.2
5 x 29 7.4 2.3 0.6 0.3
6 x 49.5 12.6 3.9 1 0.5
8 x 74.5 19 5.9 1.6 0.7
10 x x 68.6 21.2 5.6 2.6
20 x x x x 11.8 5.6
30 x x x x 20.1 9.5
40 x x x x x 9.5
50 x x x x x 14.4

TOTAL DYNAMIC HEAD= 34.31926 + (1 ft effective vertical Head/100 ft)


= 34.31926 + 1.9686
= 36.28786 Ft

FIND THE SUMBERSIBLE SOLAR PUMP THAT FITS THE BILL

Required Discharge= 321.60 GPM


Head= 36.28786 Ft OR 11.06 meters
7.47913