Sunpro Series

R32 EVI Inverter Heating & Cooling Heat Pump

Guangdong New Energy Technology Development Co.,Ltd.


NO.125, Chuangyou Road, Xintang Town, Zengcheng, Guangzhou, Guangdong, P.R.China
+86-20-86735355
[email protected]
www.newntide.com
R32 Low GWP Refrigerant
70%
CO² Emissions

Compared to the refrigerants widely used today, such as R407C and R410A, Lower GWP
R32 has a global warming potential that is two-thirds lower and is remark-
2088
able for its low environmental impact, which helps to speed up its popularity 1740
in the heat pump industry.
675

R410A R407C R32

Wide Running Range

15:43Powered by inverter EVI technology, Sunpro Series Air to Water Heat Pump features a wide operating temperature range
for house heating, cooling, and domestic hot water. It means it can reach high water temperature in a cold climate and work
safely and reliably at ambient temperatures as low as -25℃.

Outlet Water Temperature(℃)


65

55

45

35

25

15

5 Ambient Temperature(℃)

-25 -15 -5 5 15 25 35 45

Sunpro Series Heat Pump Traditional Heat Pump

Increased Efficiency

With a maximum COP of 6.15 and a top level of Erp A+++, the Sunpro Series EVI DC inverter heat pump can charge and recircu-
late more efficiently than the DC inverter heat pump. It consumes less energy and therefore helps families reduce heating
bills.

COP up to 6.15
Hot Water Temp℃

6.00 W35℃
5.00 W45℃
4.00 W55℃
3.00
2.00
1.00 Ambient Temperature(℃)
0.00
-25℃ -20℃ -15℃ -7℃ 2℃ 7℃ 12℃ 20℃

NEWNTIDE PRODUCT DESCRIPTION


Intelligent Defrosting Full DC Inverter Technology

Intelligent defrosting uses pressure sliding defrosting technology to determine the exact defrosting time and start pressure Sunpro Series adopts a twin-rotary inverter compressor and inverter brushless motor. With this technology, users can enjoy
according to the actual ambient temperature. It saves energy and makes the heat pump work with high efficiency. maximum comfort at the lowest costs.

Defrosting Pressure

Temperature

Shorter Heating Time Smaller Temperature Fluctuation

Ambient Temperature

Smart Colorful Touch Display


Running Time

Target Temperature Sunpro Series Traditional ON/OFF Heat Pump


The Sunpro Series is equipped with a 4 -inch color room display, which can be installed on the wall. Featured with 0.5°C
precise temperature control, water temperature curve display, easy timing, one-key mute, etc,it is very user-friendly.

Intelligent Water Temperature Adjustment

The unique control logic enables Sunspro Series to adjust the outlet water temperature intelligently, according to the
real-time ambient temperature. Thanks to this function, users can not only enjoy great comfort but also save more bills.

Target Temperature

55℃

35℃

Ambient Temperature

-20℃ 20℃

NEWNTIDE PRODUCT DESCRIPTION


Super Low Noise Global Application Potential

In addition to brushless DC inverter fans, Sunpro Series EVI heat pumps adopt reinforced sound reduction measures such as With the above features, Sunpro Series can be widely used:
the dual shock absorption by the famous-brand compressor. The sound levels start as low as 42dB(A), making itself the
quietest system in our DC inverter lineup.

Floor Heating Central Heating


Sunpro Series
EVI Heat Pump -25℃~
43℃

Heating, Cooling, EVI technology


and DHW all year ensures a stable
round. operation from
-25℃ to 43℃.

Shower Hot Water Kitchen Hot Water

Various capacity Wide Voltage Range


selections ( 170-254V for single
(8 ~ 30 kW) for phase, 320-460V for
different houses. 3 phase)

Guaranteed Safety
Components and Details
The refrigerant R32 is considered to be environmentally friendly, but improper handling and storage might lead to potential
safety issues. All of this can be avoided by using the Sunpro series R32 DC inverter heat pump since they are
designed with anti-explosion measures to guarantee safety.

Inverter Brushless DC Smart Wifi


Compressor Inverter Motor Control

Unique Fan Guard 4-inch Touch Hidden Screw


Screen Dispaly Design

NEWNTIDE PRODUCT DESCRIPTION


Parameters
R32 EVI Full inverter Heating & Cooling Heat Pump

Model NE-F 40HCR4INEM-SA 60HCR4INEM-SA 90HCR4INEM-SA 130HCR4INEM-SA 160HCR4INEM-SA Model NE-F 180HCR4INEM-SA 200HCR4TINEM-SA 230HCR4TINEM-SA 260HCR4TINEM-SA 310HCR4TINEM-SA
Power Supply(V/Ph/Hz) 220-240V~/50Hz 380-415V/3N~/ 50Hz Power Supply(V/Ph/Hz) 380-415V/3N~/ 50Hz
Refrigerant Type R32 Refrigerant Type R32
[Space Heating] Ambient Temperature (DB/WB): 7°C/6°C, Water Temperature (Inlet/Outlet): 30°C/35°C. [Space Heating] Ambient Temperature (DB/WB): 7°C/6°C, Water Temperature (Inlet/Outlet): 30°C/35°C.
Max. Heating Capacity(kW) 1.69~4.12 1.73~6.06 2.32~8.65 3.53~12.76 4.81~16.05 Max. Heating Capacity(kW) 6.15~18.33 6.36~20.44 8.43~23.11 8.54~25.93 10.13~31.32
Power Input(kW) 0.27~0.88 0.28~1.31 0.38~1.88 0.58~2.83 0.81~3.67 Power Input(kW) 1.03~4.14 1.08~4.61 1.41~5.32 1.46~6.08 1.73~7.23
COP 6.15~4.65 6.13~4.61 6.06~4.59 6.01~4.51 5.89~4.37 COP 5.95~4.42 5.87~4.33 5.94~4.34 5.82~4.26 5.83~4.33
[Space Heating] Ambient Temperature (DB/WB): 7°C/6°C, Water Temperature (Inlet/Outlet): 50°C/55°C. [Space Heating] Ambient Temperature (DB/WB): 7°C/6°C, Water Temperature (Inlet/Outlet): 50°C/55°C.
Max. Heating Capacity(kW) 1.09~3.52 1.12~5.29 1.81~7.83 2.38~10.86 2.82~14.12 Max. Heating Capacity(kW) 3.44~16.40 3.41~17.69 4.41~20.09 4.67~22.27 5.34~26.89
Power Input(kW) 0.25~1.32 0.26~2.03 0.43~3.05 0.58~4.31 0.64~5.34 Power Input(kW) 0.78~6.33 0.89~7.04 1.01~7.61 1.04~8.66 1.25~10.54
COP 4.32~2.65 4.24~2.61 4.15~2.56 4.11~2.52 4.37~2.64 COP 4.39~2.59 4.32~2.51 4.34~2.64 4.28~2.57 4.27~2.55
[Space Cooling] Ambient Temperature (DB/WB): 35°C / -, Water Temperature (Inlet/Outlet): 12°C/7°C. [Space Cooling] Ambient Temperature (DB/WB): 35°C / -, Water Temperature (Inlet/Outlet): 12°C/7°C.
Max. Cooling Capacity(kW) 0.95~3.41 0.97~4.86 1.43~7.17 2.06~10.33 2.63~13.16 Max. Cooling Capacity(kW) 3.12~15.13 3.31~16.82 3.80~19.01 4.37~21.85 5.03~26.39
Power Input(kW) 0.20~1.22 0.21~1.76 0.32~2.67 0.46~3.89 0.59~5.02 Power Input(kW) 0.71~5.73 0.76~6.44 0.88~7.23 1.02~8.40 1.19~10.11
EER 4.61~2.79 4.55~2.75 4.45~2.68 4.43~2.65 4.41~2.62 EER 4.36~2.65 4.32~2.61 4.31~2.63 4.25~2.60 4.23~2.61
[Hot Water] Ambient Temperature (DB/WB): 20°C/15°C, Water Temperature from 15°C to 55°C. [Hot Water] Ambient Temperature (DB/WB): 20°C/15°C, Water Temperature from 15°C to 55°C.
Max. Heating Capacity(kW) 4.91 7.32 10.37 15.31 19.25 Max. Heating Capacity(kW) 21.60 23.95 27.73 31.07 37.52
Power Input(kW) 1.01 1.51 2.15 3.21 3.98 Power Input(kW) 4.54 5.05 5.74 6.52 7.95
COP 4.83 4.83 4.82 4.76 4.83 COP 4.75 4.74 4.83 4.76 4.72
ErP Level (35°C) A+++ ErP Level (35°C) A+++
ErP Level (55°C) A++ ErP Level (55°C) A++
Electric Heater Rated Input(kW) 3 Electric Heater Rated Input(kW) 3
Max. Power Input(kW) 4.4(1.4+3) 5.1(2.1+3) 6.1(3.1+3) 7.5(4.5+3) 8.8(5.8+3) Max. Power Input(kW) 9.6(6.6+3) 10.2(7.2+3) 11.5(8.5+3) 12.7(9.7+3) 14.7(11.7+3)
Max. Running Current (A) 20(6.3+13.7) 23.2(9.5+13.7) 27.8(14.1+13.7) 341(20.4+13.7) 23.8(10.1+13.7) Max. Running Current (A) 25.2(11.5+13.7) 26(12.3+13.7) 28.3(14.6+13.7) 30.4(16.7+13.7) 33.9(20.2+13.7)
Circulating Pump Built-in Circulating Pump Built-in
Fan Motor Type DC motor Fan Motor Type DC motor
Water Side Heat Exchanger Plate Heat Exchanger (Danfoss) Water Side Heat Exchanger Plate Heat Exchanger (Danfoss)
Air Side Heat Exchanger Finned Heat Exhanger Air Side Heat Exchanger Finned Heat Exhanger
Expansion Tank Volume (L) 2 5 Expansion Tank Volume (L) 5 8
Display 4-inch Colored Touch Screen Display 4-inch Colored Touch Screen
Wi-Fi Function Yes Wi-Fi Function Yes

Rated Water Flow (m³/h) 0.7 1 1.6 2.1 2.7 Rated Water Flow (m³/h) 3.1 3.4 4 4.4 5.24
Water Pressure Drop (kPa) 15 17 20 22 24 Water Pressure Drop (kPa) 26 28 30 31 33
Water Pipe Connection 1" 1" 1 1/4" 1 1/4" 1 1/4" Water Pipe Connection 1 1/4" 1 1/4" 1 1/2" 1 1/2" 1 1/2"
Sound Pressure Level at 1m dB(A) 42~52 42~53 43~54 43~55 44~55 Sound Pressure Level at 1m dB(A) 44~56 45~58 45~58 46~59 47~60
Operation Range (°C) -25~43 Operation Range (°C) -25~43
Max. Outlet Water Temperature (°C) 60 Max. Outlet Water Temperature (°C) 60
Water Proof Class IPX4 Water Proof Class IPX4
Electricity Shock Proof Ⅰ Electricity Shock Proof Ⅰ
Net Dimensions (L×W×H) (mm) 1150×450×695 1338 x 450 x 870 1338 x 450 x 1320 Net Dimensions (L×W×H) (mm) 1338 x 450 x 1320 1338 x 450 x 1500