Vildon Filter Tfe 90

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

TFP 90P

Cartridge Filter MERV 16

Media and support cage are


potted into cover and base for a
strong leak-proof configuration

TFP filter cartridges


provide the optimum
ratio between filtering
area, pleat depth and
number of pleats

Corrosion Resistant
End-Caps and stainless
steel internal liners

viledon depth loading synthetic media filter cartridges meet all the requirements of standard systems
as to dimensions, depth and filter performance. viledon’s filtration superiority, known as the
viledon difference, is highlighted by the following:
viledon cartridge filters are developed for use in supply TFP 90P (Plastic) is specifically designed for demanding
air systems for gas turbines and turbo compressors both corrosive environments. This TFP version includes plastic (non-
on and off shore. corrosive) and stainless steel (non-corrosive) internal liner.
The cartridge is uniquely designed to minimize pressure Moisture-resistant up to 100% relative humidity.
drops while maximizing useful service life cycles, even The TFP 90P meets the 25" W.G. GE™ 72 Hour Wet Air Filter
under extreme operating conditions. Breach Test
The synthetic media operates effectively in high Temperature Resistance: Continuous 160°F, peaks 175°F
temperatures and high relative humidity conditions, and The viledon TFP 90P filters are NOT designed for pulsing.
is resistant to chemical damage. This product has been GREENGUARD Indoor Air Quality
The TFP 90P tested in tandem (conical & cartridge) has Certified® by the GREENGUARD Environmental Institute
an initial pressure drop of only 0.55" W.G. when tested under the GREENGUARD Standard for low emitting and
@ 1,360 CFM, this greatly increases gas turbine output microbial resistant products.
while maintaining longer life versus generic "me-too"
cartridge filters.
The filter cartridges provide optimized ratio between
filtering area, pleat depth and number of pleats.
Technical Data- viledon TFP 90P
Particle Removal Efficiency Resistance Curve
100 0.80
0.76
90
0.70
80
0.60
Removal Efficiency %

70

Resistance (in WG)


60 0.50 0.50
50
0.40
40

30 0.30 0.30

20
0.20
0.16
10
0.10
0 0.07
0.1 1 10
0.00
Particle Diameter (um) 150 300 450 600 750

Initial Load 1 Load 2 Load 3 Load 4 Load 5 Air Flow Rate (CFM)

ASHRAE 52.2
BHT-07-768 REV1
Performance Unit TFP 90P
Rated Air Flow CFM 600
Initial Resistance “w.g. .50
Final Resistance “w.g. 3.2
Tandem Rated Air Flow CFM 1,360
Tandem Initial Resistance “w.g. .55
MERV@1968 16

ADDITIONAL DATA
Performance Unit TFP 90P
GE™ 72 Hour Wet Air Filter
“w.g. 25
Breach Test
Torque Recommendations ft.lbs 4
AVAILABLE SIZES
Model Length Shape OD/Bolt Hole
TFP 90P K66S1 26” Conical N/A/N/A
TFP 90P S66S1 26” Cylinder 12 3/4” / 1/2”
TFP 90 S66S1-02 26” Cylinder 12 3/4” / 1 1/4”

The figures given are mean values subject to tolerances due to normal production fluctuations. Our explicit written
confirmation is always required for the correctness and applicability of the information involved in any particular case.

viledon® is a registered trademark of Freudenberg

Freudenberg Filtration Technologies LP


2975 Pembroke Road
Hopkinsville, Ky 42240
Tel: 1-270-887-5145
Fax: 1-270-890-0743
www.freudenberg-filter.com