HiMS2000 software
for N300 Inverter
PRESENTATION
2008. 08
Electro Electric Systems 1
Contents
1. Major features of HiMS2000
2. RS485 communication network
3. Equipment for using HiMS2000 S/W
4. Cable connection & inverter setting
5. HiMS2000 S/W Installation
6. HiMS2000 S/W Operating
Thanks for your interest in our products.
This presentation introduced briefly about directions of HiMS2000 software.
For more information, please refer to our website, http://www.hyundai-elec.com , or contact us.
We look forward to a mutually rewarding relationship with you.
Electro Electric Systems 2
Major Features of HiMS2000
HiMS is an initial letter for
9 HiMS
H yundai
H ii nverter M anagement
M SS ystem.
9 It is possible to
-. control inverter-motor driving system on your laptop.
-. observe inverter-motor driving system on your laptop.
-. change or check inverter parameters on your laptop.
-. watch the waveform inverter-motor driving system.
-. simulate some applications.
Electro Electric Systems 3
RS485 Communication Network
PC or
Notebook
N300 #1 N300 #2 N300 #N
RS232
Signal
Converter
TRX+ TRX-
TM2 TM2 TM2
RS485 SP SN RP SN SP SN RP SN SP SN RP SN
Send/Receive (-)
Send/Receive (+)
Electro Electric Systems Termination Jumper 4
Equipment for using Hims2000 S/W
N300 Inverter
Notebook PC or Desktop PC
z CPU : Pentium III, 800MHz or more
z Memory : 128MB RAM or more
z Comm. Channel : RS232 Interface
z Operating system : Windows98, Windows2000, WindowsXP
Signal converter : RS232 To RS485
Connection cable : Shield cable
Electro Electric Systems 5
Cable connection & inverter setting (1/3)
Step 1 : Cable connection between PC and N300.
N300
PC RS232 Converter RS485
Item Pin No. Item Pin. No. Terminal
DCD 1 TXD N/A SP
RXD 2 RXD N/A SN
TXD 3 GND N/A
DTR 4
SG(GND) 5 TRXD+ N/A
DSR 6 TRXD- N/A
RTS 7
CTS 8
RI 9
* NOTE : The name, pin number and cable connection method can differ according to
equipment manufacturing company.
Please, connect cable after confirm manual contents in your converters.
If the PLCs have a RS485 communication port, don’t use the converter (RS232
to RS485 converter) between the PLC and inverters.
Electro Electric Systems 6
Cable connection & inverter setting (2/3)
Step 2 : Set a termination resistor at end of the wiring.
Electro Electric Systems 7
Cable connection & inverter setting (3/3)
Step 3 : Setting for inverter function code
Fucntion Default Setting for
Item Description
code setting HiMS2000
Data command 02 : Digital operator
C070 02 03
source 03 : RS485 connector
Communication 04 : 4800 bps
C071 04 02
baud rate 05 : 9600 bps
C072 Node address 1. 1.~32. Node address for inverter
7 : 7 bit,
C073 Data bits 7 8
8 : 8 bit
C074 Parity 00 00 No parity
C075 Stop bits 1 1 1 : 1 bit
0 to 1000ms time that the inverter waits fo
C078 Wait time 0. 0.
respond to network master
Electro Electric Systems 8
HiMS2000 S/W Installation(1/4)
Step 1 : Download S/W on WEB site, and execute
the setup.exe file. (http://www.hyundai-elec.com)
Step 2 : S/W installation will be progressed.
Click the “Next” button two times.
Electro Electric Systems 9
HiMS2000 S/W Installation(2/4)
Step 3 : Fill in the “Name” and Step 4 : Click the “Next” button.
“Company” text field, and click the Or select another directory and click
“Next” button. the “Next” button.
Electro Electric Systems 10
HiMS2000 S/W Installation(3/4)
Step 5 : Select the Program Step 6 : Click the “Next” button.
Folder listed below, and click “Next”
button.
Electro Electric Systems 11
HiMS2000 S/W Installation(4/4)
Step 7 : Click the “Finish” button if the setup is finished .
Electro Electric Systems 12
HiMS2000 S/W Operating(1/22)
Starting HiMS2000
¾ Start HiMS2000 S/W
¾ Set the COM port (COM1 or COM2 or another
number in case of using the USB To RS232
converter) ; Please check your computer.
¾ Click the “OK” button.
¾ After click the “OK” button, you can see the
following message.
Electro Electric Systems 13
HiMS2000 S/W Operating(2/22)
Calculation View Communication Status
Basic screen
Start Drive Parameter Auto tuning Trend Trip Monitor Parameter Parameter Parameter Node
View View View View View View View Upload Download Compare Address
view view view
Electro Electric Systems
Display system Information Display current inverter status 14
HiMS2000 S/W Operating(3/22)
Operating screen
¾ Set both Frequency command and Drive command to RS485 in order to
operate Inverter using HiMS2000 software.
¾ Click the icon on HiMS2000 display screen.
Electro Electric Systems 15
HiMS2000 S/W Operating(4/22)
Operating screen
¾ Set frequency command to RS485.
Set the frequency commanding
using “+” button.
Electro Electric Systems 16
HiMS2000 S/W Operating(5/22)
Operating screen
¾ Set Drive Command to RS485
Set the Drive command
using “+” button.
Electro Electric Systems 17
HiMS2000 S/W Operating(6/22)
Operating screen
¾ Set Control methods to VC.
Set the Control methods
using “+” button.
Electro Electric Systems 18
HiMS2000 S/W Operating(7/22)
Operating screen
¾ Set frequency and rotating direction
Display current output frequency
Display current rotating direction
Set rotating direction
Set frequency command
Electro Electric Systems 19
HiMS2000 S/W Operating(8/22)
Parameter screen
¾ Parameter Up-load
All of the inverter parameter is uploaded to the PC.
Parameter Up-load icon
Electro Electric Systems 20
HiMS2000 S/W Operating(9/22)
Parameter screen
¾ Change the setting value of Parameter
Parameter code
Setting value
Parameter setting
range
Electro Electric Systems 21
HiMS2000 S/W Operating(10/22)
Parameter screen
¾ Save Parameter : User can save all of the inverter parameter in PC.
Save parameter menu
File name
Electro Electric Systems 22
HiMS2000 S/W Operating(11/22)
Parameter screen
¾ Download Parameter
All of the inverter parameter is downloaded to the inverter.
In case of exchanging inverters, you can do it at once with this function.
Download parameter icon
Download parameter menu
Electro Electric Systems 23
HiMS2000 S/W Operating(12/22)
Parameter screen
¾ Compare Parameter
Compare saving parameter in PC with current setting value.
After comparing, display only different parameter between saving and setting parameter.
In case of malfunction suddenly, user can check parameters at once with this function
Compare parameter icon
Download parameter menu
Electro Electric Systems 24
HiMS2000 S/W Operating(13/22)
Graph screen
¾ User can check output frequency, current, voltage, power, input/output
terminal function and contact status.
Graph menu
Red : terminal closed
Green : terminal open
Electro Electric Systems 25
HiMS2000 S/W Operating(14/22)
Graph screen
¾ User can change Y-axis range using “+” button.
Click
Electro Electric Systems 26
HiMS2000 S/W Operating(15/22)
Trend screen
¾ User can check some waveforms only one window for comparing each
other.
Trend menu
User can set each channel
ratio.
For example ;
- frequency : 10
- channel range : -100 ~ 100
User can see some inverter
output data.
Electro Electric Systems 27
HiMS2000 S/W Operating(16/22)
Trip screen
¾ User can check the 6-times inverter trip information.
Trip history menu
Contents of trip event history
Electro Electric Systems 28
HiMS2000 S/W Operating(17/22)
Simulator screen
¾ Driving simulation function (1) - Crane
User can select Crane or
Laundry.
Electro Electric Systems 29
HiMS2000 S/W Operating(18/22)
Simulator screen
¾ Driving simulation function (2) - Laundry
User can select Crane or
Laundry.
Electro Electric Systems 30
HiMS2000 S/W Operating(19/22)
Save EEPROM
¾ If user changed the value of parameter of inverter, refer to below.
① In case inverter power does not turn off, inverter is driver with changed
parameter.
② But, in case inverter power turn off and turn on, all of the data that user
changed using HiMS2000 disappear from memory of inverter.
③ Therefore, must store data to EEPROM in case user wants to store.
Electro Electric Systems 31
HiMS2000 S/W Operating(20/22)
Save EEPROM
¾ EEPROM Check : Verifies whether or nor it is possible to set a particular
parameter in the EEPROM.
EEPROM check menu
Click “Yes” button in above.
Electro Electric Systems 32
HiMS2000 S/W Operating(21/22)
Save EEPROM
¾ EEPROM Save : Sets a value in the EEPROM.
EEPROM save menu
Click “Yes” button in above.
Electro Electric Systems 33
HiMS2000 S/W Operating(22/22)
Calculate constant
¾ Recalculates the inverter’s internal motor constants.
¾ Use this function after the base frequency or any Hxxx parameters are
changed via the serial link commands.
EEPROM check menu
Click “Yes” button in above.
Electro Electric Systems 34
The End
Thank you for your attention.
http://www.hyundai-elec.com
Electro Electric Systems 35