Fault Code: 122 Intake Manifold 1 Pressure Sensor Circuit - Voltage Above Normal or Shorted To High Source
Fault Code: 122 Intake Manifold 1 Pressure Sensor Circuit - Voltage Above Normal or Shorted To High Source
QSK38, QSK50 and QSK60 (CM850 Modular Common Rail System) Troubleshooting and Rep…
(/qs3/pubsys2/xml/en/manual/4021533/4021533-titlepage.html)
Overview
Codes Reason Effect
Fault Code: 122 Intake Manifold 1 Pressure
Sensor Circuit - Voltage
PID(P):
Above Normal or Shorted to None on performance for
SPN: 102
High Source. High signal Power Generation
FMI: 3/3
voltage detected at
the applications.
Lamp: Amber
intake manifold pressure
SRT: circuit.
https://quickserve.cummins.com/qs3/portal/service/manual/en/4021533/ 1/3
9/21/22, 12:42 PM QuickServe Online | (4021533) QSK38, QSK50 and QSK60 (CM850 Modular Common Rail System) Troubleshooting and Rep…
Intake Manifold 1 Pressure Sensor Circuit QSK50 and QSK60 Power Generation Engines
Circuit Description
The intake manifold 1 pressure sensor monitors intake manifold pressure and passes the
information to the engine control
module (ECM) through the engine harness. If the intake
manifold 1 pressure sensor circuit voltage becomes too high, it will
cause a derate condition on
industrial applications.
Component Location
The intake manifold 1 pressure sensor is located in the left bank front air intake manifold. Refer to
Procedure 100-002 (/qs3/pubsys2/xml/en/procedures/05/05-100-002-tr.html) for a detailed
component location view.
Shoptalk
There are multiple ECMs for the engine models included in this manual. Each ECM has an
individual source address that displays
when INSITE™ electronic service tool is connected.
When troubleshooting a fault code, use the source address displayed in
INSITE™ electronic
service tool to determine which ECM and circuit is affected.
The intake manifold 1 pressure sensor shares supply and return wires in the engine harness with
other sensors. Opens and shorts
in the engine harness can cause multiple fault codes to be
active. Before troubleshooting Fault Code 122, check for multiple
faults.
https://quickserve.cummins.com/qs3/portal/service/manual/en/4021533/ 2/3
9/21/22, 12:42 PM QuickServe Online | (4021533) QSK38, QSK50 and QSK60 (CM850 Modular Common Rail System) Troubleshooting and Rep…
Last Modified: 29-May-2012
https://quickserve.cummins.com/qs3/portal/service/manual/en/4021533/ 3/3