FATEKIoT QuickStart en
FATEKIoT QuickStart en
Ver 1.2
2019.11.04
Tony Liu
FATEK Automation
1
Agenda
▪ Glossary
▪ Quick Start for setting a FATEK IoT project on the Web site
▪ Quick Start for basic function on the Web site
▪ Quick Start for the APP (FATEK IoT)
▪ Quick Start for FvDesigner iAccess Function
2 FATEK Automation
Glossary
4 FATEK Automation
Glossary – Dataitem
⚫ Dataitem is a general name for the specific registers on iMonoitor or iAccess.
⚫ Dataitem could be an internal register in HMI or an external register in the link device(PLC).
⚫ Dataitem supports these function:
➢ Read/Write Data
➢ Data log (iMonitor only)
➢ Alarm (iMonitor only)
5 FATEK Automation
Glossary – HWID, Service Password, and LID
⚫ The three important items are in HMI system setting
⚫ HWID is the unique and unchangeable ID. It has been decided in the manufactory. When you
configure the device(HMI) in your a FATEK IoT project, you will need it.
⚫ Service Password is the password for iMonitor and iAccess.
⚫ License for iAccess, provided by dealer. It can not reuse for other devices when it's activated.
84DE3FDA-E8A9-4575-8367-EF07FBA0AD1E
1234
EFGHXWZHYNSPXKBRWEN4468ULOQ
6 FATEK Automation
Quick Start for setting a FATEK IoT
project on the web site
8 FATEK Automation
The project setting UI introduction
Config Area
9 FATEK Automation
User setting UI introduction
Note:
1. After adding a User Admin or User, go to the registered email to check up the registration
authentication letter to activate the account (Figure 10).
10 2. User list will display the certification status (the certification letter will expire after 72 hours.) FATEK Automation
iMonitor Dataitems setting UI introduction
11 FATEK Automation
iMonitor Dataitems setting UI introduction
- Device Setting
If your HMI project (FvDesigner) has link devices (PLC),you may be set the
link device first, before configuring an external register as a Dataitem.
Important:
The settings for HWID and Service Password in the device setting must be same with ones in HIM system
12 FATEK Automation
setting. If you set them on the web first, please don’t forget to set them on HMI, otherwise the FATEK IoT(HMI)
never be enabled.
iMonitor Dataitems setting UI introduction
- Dataitem Setting
Hint:
The rule of register string validity is same with FvDesigner. We
recommend to copy the register string from FvDesiger first,
especially the Dataitem is an external register. It can guarantee
the string validity. In the future, we will provide the register string
validation function on the web UI.
13 FATEK Automation
iMonitor Dataitems setting UI introduction
- Dataitem Group Setting
Decide that which device provides location for the Dataitem group
VirHMI_01 AAA
` Temperature_1 Speed_1 `
BBB
Temperature_2 Speed_2
Temperature_3 Speed_3
CCC
Temperature_4 Speed_4
Important:
iMonitor only access the Dataitem in the Dataitem group. Please do not forget to add the interested one into the group.
14 FATEK Automation
iMonitor Dataitems setting UI introduction
- (Historic) Trend Setting
MyGP
Tem_1 Tem_2 Tem_3 Speed_2
Speed_3 Speed_4
Important:
Please remember to enable the data log function for the selected Dataitem.
15 FATEK Automation
iAccess Devices setting UI introduction
16 FATEK Automation
iAccess Devices setting UI introduction
- Device Group Setting
Decide that which device provides location for the Device group
AAA
`
BBB
CCC
Important:
iAccess only access the data item which the device is added in a device group. Please do not forget to add the interested device into the device group..
17 FATEK Automation
Quick Start for basic function on the
Web site
19 FATEK Automation
iMonitor UI introduction
- iMonitor
20 FATEK Automation
iMonitor UI introduction
- iMonitor->Detail
21 FATEK Automation
iMonitor UI introduction
- Hitoric Trend
22 FATEK Automation
iAccess UI introduction
23 FATEK Automation
iLocation UI introduction
24 FATEK Automation
Quick Start for the APP (FATEK IoT)
26 FATEK Automation
How to Logout
27 FATEK Automation
iMonitor UI introduction
Dataitem Group Detail Dataitem real time trend and data log
TonyGroup2
28 FATEK Automation
iMonitor UI introduction
- Group Detail
Device Statue Dataitem Group Detail Alarm Event
29 FATEK Automation
iMonitor UI introduction
- Historic Trend
Historic Trend
30 FATEK Automation
iAccess UI introduction
Device Group Detail iAccess Dataitem
31 FATEK Automation
Quick Start for
FvDesigner iAccess Function
33 FATEK Automation
Device Selection
34 FATEK Automation
Download, Upload and Passthrough
35 FATEK Automation