Subtle Weigh
Subtle Weigh
Product Guide
ISO SUBTLEWEIGH
9001 Electric (India) Pvt. Ltd.
Subtleweigh
Weighing & Dosing Systems Are
Recognized
Around The World
HIGH ACCURACY
STABLE PERFORMANCE
LONG - TERM LIFE
TECHNICAL
DEFINITIONS OF
TERMINOLOGY
1. RATED CAPACITY (R.C) 10. TEMPERATURE EFFECT ON ZERO BALANCE
The maximum axial load cell is designed to measure within its The change in zero balance due to a change in ambient
specification.
temperature.Usually expressed as +/- a percentage change in rated
output per degree C change in ambient temperature over the
2. RATED OUTPUT (R.O)
The algebraic difference between the outputs at no-load and at rated load. compensated temperature range.
Usually load cell output is specified in milli-volts per volt at rated capacity.
11. TERMINAL RESISTANCE, INPUT
3. NON LINEARITY The resistance of the load cell circuit measured at the excitation
terminal, at standard temperature, with no-load applied, and with the
The maximum deviation of the calibration output terminals open-circuited.
% 100
N L on increasing load only. The resistance of the load cell circuit measured at the output signal
terminals, at standard temperature, with no-load applied, and with the
excitation terminals open-circuited.
0 Output % 100
1
3 3 output. 14. EXCITATION
2
The points are taken on the same The voltage or current applied to the input terminals of the load cell.
1
continuous cycle. The deviation is
0 Output % 100 expressed as a percent of rated output. 15. SAFE OVERLOAD
The maximum load in percent of rated capacity which can be applied
5. REPEATABILITY without causing a permanent change in the performance specifications.
17. CREEP
The change in load cell output occurring with time, while under load, and
with all environmental conditions and other variables remaining
0 Output % 100
constant.Usually measured with rated load applied and expressed as a
6. ZERO BALANCE percent of rated output over a specific period of time.
The output signal of the load cell with rated excitation and with no load
applied, usually expressed in percent of rated output.
18. ACCURACY
Stated as a limit tolerance which defines the average deviation between
7. TEMPERATURE RANGE COMPENSATED
The range of temperature over which a load cell is compensated to the actual output versus theoretical output.
maintain rated output and zero balance within specific limits. In practical load cell applications, the potential errors of nonlinearity,
hysteresis, repeatability and temperature effects do not normally occur
8. TEMPERATURE RANGE, SAFE simultaneously, nor are they necessarily additive.
The range of temperature over which a load cell may be safely operated up Therefore, accuracy is calculated based upon the RMS value of
to full scale without causing failure but specifications may not be met.
potential errors, assuming a temperature band °æ 10°…. Full rated load
applied, and proper set up and calibration.
9. TEMPERATURE EFFECT ON RATED OUTPUT
The change in rated output due to a change in ambient temperature. Potential errors of the readout, cross talk, or creep effects are not
Usually expressed as + /- a percentage change in rated output per degree included.
C change in ambient temperature, over the compensated temperature
range.
Typical Dimension
Weigh Feeder is a variable speed conveyor incorporating belt weighing and speed control for installation
directly under the storage silo, suited for industrial environments with particularly heavy duty conditions. The
flow rate is held constant by varying the speed of the conveyor inversely with respect to belt load by means of
a VVVF Drive.
Material is fed into the weigh feeder via a feed hopper equipped with a manually adjustable profile gate
which controls the material bed height on the feeder belt. The weighing assembly built into the feeder
measures the gravimetric force applied by the material travelling down the belt and converts this force into
mV signal which is proportional to the loading on the belt. A digital speed sensor continuously monitors the
belt speed and the microprocessor based measurement & control system SWC32 integrates these two
signals to give you an instantaneous rate of flow and totalized weight of material that has passed through the
feeder.
Typical Dimension
In case where taking drop test is not practically possible or where interruption of the process is not
permissible for taking drop test, an on-line check weighing system can be installed along with Subtleweigh
Weighfeeders for dynamically cross-checking the weighfeeder performance and inserting the correction
factor thereafter online.
Hopper
Belt
Weighfeeder
Screw Feeder
SWC 32
SWD 32
In case of on-line check weighing, the storage silo is placed on load cells at each of its support points and the
output from these load cells are fed into the weighfeeder controller, which in this case will have an additional
weigh module.
The operator has to press a “check weighing start” button. This will automatically turn off silo feeding. Silo
feeding can be re-started once on-line calibration procedure is complete. At the end of the pre-determined
sampling time the operator will have to press the “check weighing stop” button. The loss in weight from the
silo is accurately measured by the controller and compared with the totalized weight of discharge from the
weighfeeder during this period. The correction factor is automatically generated and can be inserted at the
operator's discretion.
Depending of the material property, it is often required to install a pre-feeder before the weigh feeder. There
are various types of pre-feeders for various applications.
Opening
200 x 200
200 x 250
300 x 300
350 x 350
400 x 400
500 x 500
550 x 550
600 x 600
Screw Feeder
For application like pulvarised coal, lime,
etc. with large bunker openings, screw
feeder is used for accurately regulating
material feed in to the weighfeeder infeed
hopper.
Screw feeder consists of a tubular trough
section with screw flight, single or twin
agitator for flow assistance and a drive
assembly. The length and diameter of the
screw varies with application and
capacity.
dP
Q= Feed rate measurement with loss in weight principle
Dt
Typical Dimension
Application
Continuous measurement and feed of bulk
material streams up to approx.1200 cu.mtr/hr
at material temperature up to 500 deg.
l Iron & Steel
l Cement
l Dry Powder Chemicals
l Building Materials
Design Advantages
There are no knife edges or bearings and no
articulated joints & hence no wear & tear. The
flow rate is determined with the aid of a
maintenance free strain gauge type Load Cell.
Other advantages are fully dust free operation
& low space requirements. Pre feeders used
are for instance Star feeder (RVF), Dosing
Valve, Pneumatic Valve, Vibrating feeder or
Feed Screw.
Typical applications
Measure free flowing bulk solids such as Cement, Fly Ash, etc. during Load Out.
Measure recycles from Cement Grinding Mills when the measuring signal may be used to control the
addition of fresh material.
Feed Raw Meal to Heat Exchanger or Rotary Kin in Cement Factories
Accuracy
A regular accuracy check using a check weigh bin, an automatic check - and - correct system, is available
which ensures that a feeding and measuring accuracy of ± 0.5% to ± 1% will be achieved.
Batch weighing is an extension of the hopper weighing system, where two or more materials are desired to
be mixed in a fixed proportion. Here either each of the storage hoppers for all the materials are individually
weighed or as a standard practice, a common weigh hopper is positioned below the storage bins.
The operational sequence is such that after the first material has been filled in the common weigh hopper up
to the set weight, the signal from the weight indicator will close the discharge gate of the first storage bin and
open the discharge gate of the second storage bin. Again when the batch weight of the second material has
been reached, the signal from the weight indicator will close the discharge gate of the second storage bin
and open that of the third, and so on.
Depending on the requirement of end user the operation sequence can be fully automatic or semi-
automatic.
A Ladle Weighing System can be used to increase the safety and efficiency in the production process.
Weighbeams are installed between the base structure and the weighbridge, without need for modifications
of the ladle supporting structure. This will give the precise net weight of the molten metal in the ladle.
Weighing accuracy ± 0.5 % of full scale.
Typical Applications
l Ladle Turrets
l Ladle Ferries
l Fixed Mount Ladle Supports
Benefits
l Compact design
l Simple installation
l Suitable for harsh environment
l Maintenance free
Systems are made by SWC-32 central control unit, that reads load cell signal & if necessary speed signal
from a tachometric genetator. A set of analog & digital inputs and outputs allows data exchange between
SWC-32 & field.
An operator interface panel SWD-32 can be connected for configuration & display purposes.
Expansion modules SLCI,SPBA-32, & MOD-32 can be added, the first one is for reading another load cell
input, the second one is for profibus DP communication with PLC/DCS and the third one is for modbus
communication with PLC/DCS.
Clock 80 MHz
Supply - Auxiliary Power Supply (CN1) (the equipment must be suitably earthed)
24V DC
General Info
Page
Digital Inputs
Digital Outputs
Analog Inputs
Analog Outputs
Features
l Appropriate for weight and measurement system
l 24 bit Sigma-Delta A/D converter for high accuracy
l Simple full digital calibration
l Simulative (mV/V memory) or live load calibration
l 3 Set point relay output
l Hold, peak hold and auto zero
l Optional analog output
Technical Specification
Analog Input & A/D Conversion:
Technical
Power Supply 24 V DC
Weight 200 g
Digital Part
Option
The converted data along with two limit switch data (if applicable) are sent to the PLC/DCS through Profibus
network or analog 4-20 mA output.
l Data Aquisition system with load cell(s), speed sensor(s) & limit switch input.
Output goes to PLC/DCS through Profibus DP or 4-20mA analog output.
l Compatible with strain gauge transducers, with a maximum bridge resistance of 350 Ω.
l Parallel Redundancy.
CP 100 local control panel with digital display unit is used in conjunction with DAS32D & DAS32DH for local
control & display. Any two parameters can be displayed simultaneously in CP 100 and the same can be
used for local operation of the weighfeeder.
Hardware Features
Power Supply 24 V DC
Clock 80 MHz
Module Pulse Per Revoluation Part No. Diameter of the shaft (mm).
Tachometer 36 OPG-15D-36 15
Tachometer 1024 OPG-15D-1024 15
Phone Nos :
+ 91 (033) 6450-2112 / 2573-7167
Fax No :
+ 91 (033) 033 25735653
E-mail :
[email protected] | [email protected]
Website :