V-RTU2000 Catalogue Web

Download as pdf or txt
Download as pdf or txt
You are on page 1of 13

V-RTU2000 Product Series

V-RTU2000, Veesta Remote Terminal Unit


2000 Product Series

V-RTU 2000
Overview
V-RTU2000 Product Series is a distributive data acquisition and
control system based on microprocessor. In common SCADA
(Supervisory Control and Data Acquisition) system, performs the
tasks of collecting and processing of station data for both analog

Remote Terminal Unit


and digital signals; then V-RTU2000 receives the command from
host in master station and transmit back the acquired data, also
to perform the function “check before execution” for station
facilities to ensure a safe and reliable execution in system
control.
11
V-RTU2000 Product Series
The design of V-RTU2000 series is fully modularized with different I/O cards which combines with the
communication ability. The idea for design of V-RTU2000 is to be an aesthetic product with quantity of long-
term stability, easy maintenance, convenient wiring and flexibility in expansion. In the requirements of
today’s power utility such as engineering, operations, and maintenance departments; V-RTU2000 series

V-RTU 2000
offers flexible and economical solution.
Master
DNP3.0 or IEC-870-5 and etc
Protocol
Power Test Set

RTU Sub Rack

RS-232 RS-485 / 2-Wire


PS Card CPU Card

Remote Terminal Unit


Back-plane
RS-485 +5V
+24V

DI Card AI Card DO/DOH AO Card ACI Card ACV Card ACPM Power Meter,
Card Card etc

12
V-RTU2000 Product Series
V-RTU2000 as Bay Controller Unit (BCU) :
Based on modularity design of V-RTU2000, we can easily use V-RTU2000 as bay
controller unit. Normally a bay consist of some digital input and digital output

V-RTU 2000
points within analogue measurement and set-points data.
Master
MMI Control
Center
Bay Reactor 1 Bay Feeder 12 Bay Feeder 1
V-RTU2000 V-RTU2000 V-RTU2000

....... VC-2DCU
PS CPU DI DI DO --- --- --- PS CPU DI DI DO --- --- --- PS CPU DI DI DO --- --- ---
1 2 3 4 5 1 2 3 4 5 1 2 3 4 5

Remote Terminal Unit


PS CPU DI DI DO --- --- --- PS CPU DI DI DO --- --- --- PS CPU DI DI DO --- --- --- PS CPU DI DI DO --- --- ---
1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5

V-RTU2000 V-RTU2000 V-RTU2000 V-RTU2000


13 Bay Trans 1 Bay Trans 2 Bay Line 1 Bay Line 2
V-RTU2000 Product Series
V-RTU2000 as Distributed Terminal Unit (DTU) :
Distributed Terminal Unit, normally used in very large site platform of substations or power plants. In a
factory wiring a high number of signals to a central point is not reasonable, so using of DTU method is

V-RTU 2000
to distributed remote terminal units to number of places. Distance between parts normally can be
1200 meter and with simple repeater it can be more than 6km.

Master
Communication Control
Room Center

V-RTU2000
VC-2DCU
V-RTU2000

Remote Terminal Unit


900m 600m

PS CPU DI DI DI DI DI DI DI DI DI DI DI DI DI DI DI DI
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

PS CPU DI DI DI DI DI DI DI DI DI DI DI DI DI DI DI DI
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

1000m
Combined Section DTU
V-RTU2000
PS CPU DI DI DI DI DI DI DI DI DI DI DI DI DI DI DI DI
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

Substation DTU
PS CPU DI DI DI DI DI DI DI DI DI DI DI DI DI DI DI DI

14 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

Generation DTU
V-RTU2000 Product Series
Previous Next
FTU Fiber Fiber FTU

(Test Set)
V-RTU2000 as
FTU
DC 24V
Fiber Modem
DC 24V
Feeder Terminal Unit (FTU) :

V-RTU 2000
DNP 3.0 R S-232

Battery V-RTU2000

Charger PS C ard CPU Card


RS-2 32
RS-485
V-RTU2000 has various sub racks with
Back-plane
powerful CPU card that can be operate
DC 24V
DC 5V as controller of feeder. Pole mount
RS-485
feeder or substation feeders can be used
Battery DI Card DI Card ACC Card HDO Card HDO Card HDO Card HDO Card VR-2 760
from V-RTU2000 as FTU controller for
RTU usage and etc.

Terminal Block

Remote Terminal Unit


J1 (D I/DO) J2 (Po wer) J3 (PT) J4 (CT)

P1 P2 P3 P4

15 Control Unit

Auto Switch
V-RTU2000 Product Series
V-RTU2000 as
Data Concentrator Unit (DCU) :

V-RTU 2000
P2 C2 C1 B11 B9 B7 B5 B3 B1 A5 A4 A3 A2 A1
P1 VC-6TSG Console

C4 C3 A6 A7 A8 A9 A10 A11 A12

B12 B10 B8 B6 B4 B2

Data Concentrator Unit is a portion of


V-RTU2000, but in regards of its large
ability formed as Veesta-COM2000
Product Series model of
VC-2DCU device.

Remote Terminal Unit


16
V-RTU2000 Product Series
V-RTU2000 as Protocol Converter Unit (PCU) :
Based on VC-2DCU device a portion of V-RTU2000 product series we can configure that to convert any
protocol. It is intelligent device of protocol converter in form of any-to-any. VC-2DCU can support any

V-RTU 2000
serial device protocol as well as Ethernet device protocols and vice versa.

HDLC Indactic LAN DNP3.0 Serial DNP3.0 Serial IEC101


LAN IEC104 Modbus

Masters

Remote Terminal Unit


Slaves

SerialDNP3.0
DNP3.0 Modbus HDLC Indactic
Serial Modbus HDLC Indactic
Serial IEC101 LAN DNP3.0 LANIEC104
IEC104
17 Serial IEC101 LAN DNP3.0 LAN
V-RTU2000 Product Series
V-RTU2000 as Intelligent Electronic Device (IED) :
V-RTU2000 can be used as intelligent electronic device (IED). There are two independent communication
channels are provided by V-RTU2000 CPU Card, of which, one links to the host computer. The other

V-RTU 2000
one links to the Power Meter or other IEDs for obtaining I/O information for such equipment and also
transferring the Output control command. In addition, the V-RTU2000 also provide I/O cards (AI, DI,
AO, DO and etc.) to collect the field information and also carry out the Output of control command.
Master Device
Field Power DNP 3.0 or ModBus RTU Protocol

RS-485 RS-232

PS Card CPU RS-485 / 2-Wire


Card

Remote Terminal Unit


Back-plane

RS-485 +5V

DI Card AI Card DO/DOH AO Card ACI/ACV ACP/W ACPM Power Meter


Card Card Card Card
18
V-RTU2000 Product Series
V-RTU2000 as typical Remote Terminal Unit
(RTU) :
Typical remote terminal units, normally consist of I/O

V-RTU 2000
modules in a cubicle and placed in telemetry room
in a station under controlled. V-RTU2000 also can be
installed as typical Remote Terminal Unit with high
optional items which old system could not cover
them. So typical RTU in V-RTU2000 system, consist
PS CPU DI DI DI DI DI DI DI DI DI DI DI DI DI DI DI DI

of many facilities in operation and configuration 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

PS CPU DI DI DI DI DI DI DI DI DI DI DI DI DI DI DI DI
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

Remote Terminal Unit


PS CPU DI DI DI DI DI DI DI DI DI DI DI DI DI DI DI DI
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

19
V-RTU2000 Product Series
No Model Type Description
Dimension : 3U x 42T x 185mm (H*W*D)
1 VR-2101 RTU Rack
Slot : Power x 1, CPU x 1, IO x 5, PM x 1
Dimension : 3U x 84T x 185mm (H*W*D)

V-RTU 2000
2 VR-2101C RTU Rack
Slot : Power x 1, CPU x 1, IO x 5, PM x 4
Dimension : 3U x 42T x 185mm (H*W*D)
3 VR-2102 RTU Rack
Slot : Power x 1, CPU x 1, IO x 8
Dimension : 3U x 84T x 185mm (H*W*D)
4 VR-2103 RTU Rack
Slot : Power x 1, CPU x 2, IO x 16
Dimension : 3U x 84T x 185mm (H*W*D)
5 VR-2043 COM Rack
Slot : Power x 2, CPU x 2, CM x 16
Input : DC 24V or 48V

Remote Terminal Unit


6 VR-2707B L-PS Card
Output : 5V ±0.1V DC, 20W 24V
Input : 85-260Vrms AC, or 85-375V DC
7 VR-2708B H-PS Card
Output : 5V ±0.1V DC, 20W 24V
1x LAN Port (10/100 Ethernet, RJ-45) (@ Panel)
1x RS-232 Port (for Master) (@ Backplane)
8
20 VR-2717 CPU Card
1x RS-485 Port (for Slave Device) (@ Backplane)
1x RS-232 Port (for Test Set) (@ Panel)
V-RTU2000 Product Series
No Model Type Description

1x RS485 Port (for Master) (@ Backplabe)


9 VR-2715 CPU Card 1x RS-232 Port (for Slave Device) (@ Backplane)
1x RS-232 Port (for Test Set) (@ Panel)

V-RTU 2000
Half/Full Duplex 2/4 wire Lease Line
10 VR-2423 Modem Card V.23, V22bis, V.29, Bell202
1200/2400/9600 BPS Asynchronous
Input : DC 129V
11 VR-2722A DI Card
Point : 8
Input : DC 24V or DC 48V
12 VR-2723A DI Card
Point : 8

Remote Terminal Unit


Input : DC 24V or DC 48V
13 VR-2726 ACC Card
Point : 8
Contact : 10A (2000VA, 200W)
14 VR-2735 DO Card
Point : 4 + 1ME
21 Contact : 5A (1000VA, 100W)
15 VR-2736 DO Card
Point : 8
V-RTU2000 Product Series
No Model Type Description
Contact : 10A (2000VA, 200W)
16 VR-2737 DO Card
Point : 4

V-RTU 2000
Input : +/- 1mA
17 VR-2741 AI Card
Point : 4 (Differential)
Input : 4~20 mA
18 VR-2742 AI Card
Point : 4 (Differential)
Input : +/-5V
19 VR-2743 AI Card
Point : 4 (Differential)
Output : +/- 1mA
20 VR-2751 AO Card
Point : 4 (Differential)

Remote Terminal Unit


Output : 4~20 mA
21 VR-2752 AO Card
Point : 4 (Differential)
Input : 0 ~ 1A or 0 ~ 5A AC
22 VR-2745 ACI Card
Point : 4
22 Input : 0 ~ 120 VAC or 0 ~ 300VAC
23 VR-2746 ACV Card
Point : 8
V-RTU2000 Product Series
No Model Type Description
Power Meter
24 VR-2760 ACPM Card Input Current: 4x 0 ~ 1/5/7A,
Input Voltage: 4x 0 ~ 120/300VAC

V-RTU 2000
GPRS Modem Module Card
25 VR-2425 GPRS Modem
(Ethernet+RS-232) 5V
3g / GRPS Modem Module Card
26 VR-2426 3G/GPRS
(Ethernet+RS232) 5V
Voice+ Data Modem Module Card
27 VR-2444 PLC Modem
Voice Filter + Programmable FSK Modem , 4x Wire
ADSL Modem Card
28 VR-2454 ADSL Modem
Ethernet + RS232

Remote Terminal Unit


Charger Card
29 VR-2801C Charge Card
Input 220V 24VDC Battery , Output: 24V

23

You might also like