0% found this document useful (0 votes)
685 views12 pages

USB-CAN User Manual (v7.20)

This document summarizes the user manual for a USB-CAN device. It describes: 1) Installing the driver software and selecting the correct COM port. 2) Inserting the USB-CAN device and identifying the virtual COM port in the device manager. 3) Opening the accompanying software and configuring settings like frame type, baud rate, and start/stop buttons.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
685 views12 pages

USB-CAN User Manual (v7.20)

This document summarizes the user manual for a USB-CAN device. It describes: 1) Installing the driver software and selecting the correct COM port. 2) Inserting the USB-CAN device and identifying the virtual COM port in the device manager. 3) Opening the accompanying software and configuring settings like frame type, baud rate, and start/stop buttons.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 12

USB-CAN User Manual

1.Install the driver

In the data to see the following folder

Double-click, according to your specific system to install the

driver

2.The USB - CAN insert computer

From the device manager see USB - CAN virtual COM port

From the device manager see USB(232) - CAN virtual COM port
3.Open the USB - CAN software
Click on the Open button

According to the CAN bus selecting frame type and set CAN baud

rate, point solution set and start button, the CAN bus and the equipment

the communication.
4. Software and introduces

4.1 COM Port Settings

Will the USB - CAN insert computer, CAN automatic find the

computer COM port, choose good port CAN, CAN open or closed port,

this with serial debugging assistant similar, communication baud rate is

fixed 1228800 BSP.

4.2 CAN Settings

Work patterns include normal mode, Loop back mode, silent mode, Loop

back + silent mode


Normal mode: is CAN normal communication model, CAN be normal to

the bus to send and receive data

Loop back mode: send data CAN be sent to CAN bus, and at the same

time, feedback internal region of acceptance, ignore accept pin of the

actual state and CAN be used for self test

Silent mode: CAN normal accept data, but CAN only send recessive

position, and CAN't really send message, often is applied to the analysis

of CAN bus activities

Loop back + silent mode: the model can be used for "hot self test",

namely online self test. Like a ring back mode that self test, but does not

affect the CAN bus system.

Frame type: standard frame (CAN2.0 A 11 ID) extended frame (CAN2.0 B

29 ID)

CAN baud rate: CAN the direct selection CAN communication commonly

used baud rate:

1M,800K,500K,400K,250K,200K,125K,100K,50K,20K,10K,5K

f it CAN be directly set the baud rate and you CAN equipment baud rate

does not agree, CAN choose


Fixed 20 bytes to send and receive: CAN converter internal there are

two agreements, one CAN be the length of the communication protocol,

is a kind of fixed 20 bytes of communication protocol, communication

protocol will be fixed after selected 20, variable protocol communication

is not selected

Manual set bps: After the choice will jump out of a custom baud rate

dialog box

The top position CAN baud rate calculation formula, and at the same time
set phase buffer 1, phase buffer 2, and preassigned frequency is ok

Filter ID and Mask ID: are hexadecimal data filtering the IDs and Mask ID
standard frames low 11 (range: 0x00000000 to 0x000007ff) extended frame
filter ID and Mask ID 29 (range 0x00000000 to 0x1fffffff)

Only send once: CAN communication is usually send unsuccessful

automatic repeat, if have been circulating send data, CAN set banned

message automatic repeat


Click , CAN undertake the CAN communication
Frame format contains data frames and remote frame, frame ID is

hexadecimal data, the standard frame ID the range of 0 x00000000 ~ 0

x000007fff, to expand frame ID the range of 0 x00000000 ~ 0 x1fffffff. To

send data also for hexadecimal data. The data in the figure are 0X11

0x22 0x33 0x44 0x55 0x66 0x77 0x88, respectively.

4.3 Sending a single frame data area

Click on the button will be the frame data sent to the


CAN bus

4.4 Send multiple frames data

Add button: When sending multiple frame area below the selected row

will add a frame data


Delete button: To delete the selected rows

Clear button: Send clear area frame to send all the data

Interval: Connected area frame to send on the sending time interval of

two frames (ms)

Send selected frame: Click on this button will send multiple frames in

the selected row

Sequence Selected and then click the send selected frame will

automatically switch to the next frame

Cycle: send cycle is repeated

Stop: cancel sending multiple frames command

Data editing in sending multiple frames area editor

4.5 Reply to reply

ADD: In the automatic response area below the selected row will add a

automatic response data

Delete: To delete the selected rows

Clear: All the data will clear to send automatic response area
Auto Answer: Will be selected after receiving to accept ID will

automatically return the corresponding frame ID and data

4.6 CAN Bus State

Mainly used in turn CAN see USB device CAN state

4.7 Receive ID Configure

Add: Accept the area below the selected row configuration will add a

automatic response data


Delete: To delete the selected rows

Enable: Converter after click on this button will only upload

configuration accept ID area ID set inside, other ID are not uploaded to

the computer

Disable: Converter after click this button to upload all ID data to the

computer

4.8 ending and receiving data display area

Clear: empty to send and receive data display so data

Pause: pause in the sending and receiving display area shows that other

data

Continue to: continue to show to send and receive data

Save: can send and receive data buffer data storage that can hold two

format, excel or TXT text


Display receive only: can send and receive data area show only accept

data

Auto refresh: when display only accept data, CAN choose to be

automatic refresh, this time data are real-time refresh, rather than

increasing column display, this function CAN be concluded CAN

summarize ID data

Select any line

The left mouse button double click it


5.COM bps select

USB - CAN power on when to send and receive light flash one at the

same time, the COM baud rate to 2000000 BPS, flash two at the same

time, the COM baud rate to 1228800 BPS, flash three times at the same

time, the COM baud rate to 115200 BPS, flash four at the same time, the

corresponding COM baud rate to 38400 BPS, flash five times at the same

time, the corresponding COM baud rate to 19200 BPS, flash six at the

same time, the corresponding COM baud rate to 9600 BPS