Compressed Air Drain Trap: CA - 14 C.I
Compressed Air Drain Trap: CA - 14 C.I
Compressed Air Drain Trap: CA - 14 C.I
CA 14 C.I
Description: The CA 14 C.I. is a float type automatic liquid drain trap for air systems. It has a cast iron body and cover with synthetic rubber valve head for positive closure. Available Sizes and end connections: 15, 20 & 25 NB Screwed: BSPT/NPT Limiting Conditions: PMA - Max. allowable pressure TMA - Max. allowable temperature TMO - Max. operating temperature Cold hydraulic test pressure PMX - Max. differential pressure = 13.0 bar = 220C = 127C = 26.0 bar (g). = 13 bar
Materials:
No. Part 1. 2. 3. 4. 5. 6. 7. 8. 9. Base Cover Bolts Cover Gasket Cover Valve Seat Valve Seat Gasket Set Screws Ball Float & Lever Pivot Frame Material Cast Iron Carbon Steel Standard IS210FG260 H.T. IS 1367 Gr8
E 120 135
Stainless Steel ASTMA-743 Gr.CA40 Stainless Steel ASTM A - 240 Type 304 Stainless Steel IS 1364 Type 304 Stainless Steel ASTM A - 240 Type 304 Stainless Steel ASTM A - 240 Type 304 Stainless Steel BS 2056 Type 302 302 S26 Synthetic Rubber Viton
Installation: The trap should be fitted in a horizontal plane or vertical plane with inlet at the top so that the float mechanism is free to rise and fall in vertical plane. Point arrow on name plate downwards. The arrow on the casting indicates the flow direction. Refer user manual (latest revision) for further details.
How to fit Main Valve Assembly: Undo cover bolts and lift off base. Remove complete float assembly by undoing the two screws. Remove main valve seat and replace with a new one supplied with new gasket. Fit complete new float assembly by tightening the assembly set screws. Refit cover using new gasket. Recommended tightening torques: Main Valve Seat 25-35 Nm. Cover Bolts 25-35 Nm. Main Valve Assly. Screws 2.5 -3 Nm. Spare Parts: (Refer Fig. below.) The spare parts available are shown in heavy outline. Parts drawn in broken lines are not supplied as spares Available Spares: Main Valve Assembly Maintenance: With suitable isolation, repairs can be carried out with the trap in the line. When reassembling it is advisable to make sure that all the joint faces are clean. How to fit Main Valve: Undo cover bolts and lift off base, withdraw pivot pin to release float and lever from bracket. Push out dumbell shaped valve and replace with new one. Reassemble and refit cover using new gasket. Set of all Gaskets (Packet of 3) Float assly. A, B, C,D, E, F, G, T B, T 'C'
How to Order: Always order spares by using the description given in the column headed 'Available Spares' In User Manual. How to Specify: Example: 20 NB SPIRAX - MARSHALL CA 14 C.I. screwed BSPT.