Samsung Inverter Ducted Hideaways - Advanced Climate Solutions 2

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

Samsung Inverter MSP Duct

Samsung quality and energy-efficient Inverter technology


ensure economical, reliable airconditioning of large areas

• Top-quality energy-efficient Inverter Ducted heating/cooling

• Available in sizes from 24 000 BTU to 48 000 BTU

• Single and 3-phase models

• 50m to 75m piping length to outdoor unit/30m elevation

• Environmentally-friendly R410A gas

• Supported nationwide by Samsung Air


Samsung Inverter MSP Duct
Samsung quality and energy-efficient Inverter technology
ensure economical, reliable airconditioning of large areas
W herever ducted airconditioning is called for, Samsung Inverter MSP is the
logical choice. Thanks to highly-efficient Inverter technology, electricity
usage is kept to a minimum, while R410A gas ensures eco-friendliness. For
full information, please contact Samsung Air.
S P E C I F I C AT I O N S
Indoor unit DH070EAV1 DH090EAV DH105EAV DH105EAV DH140EAV DH140EAV
Model
Outdoor unit UH070EAV1 UH090EAV UH105EAV UH105GAV UH140EAV UH140GAV
Capacity (Min./Standard/Max) Cooling *1) Watts 2,200/7,100/8,000 3,000/9,000/10,000 3,350/10,500/12,000 3,350/10,500/12,000 3,450/14,000/15,400 3,450/14,000/15,400
Heating *2) Watts 1,900/8,000/11,000 3,300/9,500/13,500 2,600/11,200/15,500 2,600/11,200/15,500 3,750/16,000/18,500 3,750/16,000/18,500
Power Input (Min./Standard/Max) Cooling Watts 600/2,210/2,600 840/2,800/3,400 830/3,270/3,700 830/3,270/3,700 1,110/4,650/5,700 1,110/4,650/5,700
Heating Watts 470/2,210/3,700 760/2,780/4,790 740/3,100/5,500 740/3,100/5,500 1,020/4,430/5,800 1,020/4,430/5,800
E.E.R Cooling W/W 3.21(A) 3.21(A) 3.21(A) 3.21(A) 3.01(B) 3.01(B)
Heating W/W 3.62(A) 3.41(B) 3.61(A) 3.61(A) 3.61(A) 3.61(A)
Running Current Cooling Amps 2.9/10.0/12.0 3.5/12.4/15.0 3.8/14.7/16.8 1.4/5.0/6.1 5.0/20.6/23.5 1.8/7.4/8.8
(Min./Standard/Max.) Heating Amps 2.8/10.0/16.5 3.1/12.3/24.5 4.5/14.1/25.0 1.3/5.0/8.5 4.5/19.6/26.5 1.7/7.0/9.5.
Piping Connection Liquid mm (inch) 6.35(1/4) 9.52(3/8) 9.52(3/8) 9.52(3/8) 9.52(3/8) 9.52(3/8)
Gas mm (inch) 15.88(5/8) 15.88(5/8) 15.88(5/8) 15.88(5/8) 19.05(3/4) 19.05(3/4)
Power Supply Ø/V/Hz 1/220-240/50 1/220-240/50 1/220-240/50 3/380-415/50 1/220-240/50 3/380-415/50
INDOOR UNIT
Model DH070EAV1 DH090EAV DH105EAV DH105EAV DH140EAV DH140EAV
Panel - - - - - -
Fan Type SIROCCO FAN SIROCCO FAN SIROCCO FAN SIROCCO FAN SIROCCO FAN SIROCCO FAN
Air Flow Rate m3/min 19.6 24 28.1 27.5/28.1 36.8 35.6/36.8
External Static Pressure (Min./Standard/Max.) mmAq 0/4/8 0/6/8 0/8/10 0/8/12 0/8/10 0/8/12
Set Dimension (Net) WxHxD mm 1,150x260x480 1,150x260x480 1,150x320x480 1,150x320x480 1,200x360x650 1,200x360x650
Dimension (Gross) WxHxD mm 1,390x345x575 1,390x345x575 1,396x424x584 1,396x424x584 1,447x425x769 1,447x425x769
Weight (Net/Gross) kg 34/40 33/40 39/46 39/46 55/60 55/60
Panel Dimension (Net) WxHxD mm - - - - - -
Dimension (Gross) WxHxD mm - - - - - -
Weight (Net/Gross) kg - - - - - -
Sound Pressure Level *3) High/Low dB(A) 39/35 39/35 39/35 39/35 43/38 43/38
Drain Pump Kit (Option) MDP-M075SGU1 MDP-M075SGU1 MDP-M075SGU1 MDP-M075SGU1 MDP-M075SGU2 MDP-M075SGU2
Indoor Filter DEFAULT DEFAULT DEFAULT DEFAULT DEFAULT DEFAULT
OUTDOOR UNIT
Model UH070EAV1 UH090EAV UH105EAV UH105GAV UH140EAV UH140GAV
Compressor TWIN BLDC TWIN BLDC TWIN BLDC TWIN BLDC TWIN BLDC TWIN BLDC
Refrigerant Type R410A R410A R410A R410A R410A R410A
Set Dimension (Net) WxHxD mm 880x798x310 932x1,128x375 932x1,128x375 932x1,128x375 932x1,128x375 932x1,128x375
Dimension (Gross) WxHxD mm 1,038x861x406 1,091x1,286x472 1,091x1,286x472 1,091x1,286x472 1,091x1,286x472 1,091x1,286x472
Weight (Net/Gross) kg 57/61 102/117 102/117 102/117 105/120 105/120
Sound Pressure Level dB(A) 52 56 56 56 59 59
Temperature Range Cooling ºC -15~43 -15~50 -15~50 -15~50 -15~50 -15~50
Heating ºC -20~24 -20~24 -20~24 -20~24 -20~24 -20~24
Quantity of Ref. g 1,900 2,600 2,800 2,800 3,100 2,800
Extension Length (total) m 50 75 75 75 75 75
Extension Length (elevation) m 30 30 30 30 30 30
Standard m 5 7.5 7.5 7.5 7.5 7.5
Additional Ref. g/m 30 40 40 40 40 40

1. Nominal cooling capacities are based on: Indoor temp: 27 ° CDB, 19 ° CWB; Outdoor temp: 35 ° CDB, 24 ° CWB; Equivalent ref. piping: 7.5m. Level differences: 0m
2. Nominal heating capacities are based on: Indoor temp: 20 ° CDB, 15 ° CWB; Outdoor temp: 7 ° CDB, 6 ° CWB; Equivalent ref. piping: 7.5m. Level differences: 0m.
3. Sound pressure acquired in a dead room; actual noise level may differ depending on installation conditions.
4. Specifications are subject to change without prior notice for product improvement.

S o l d a n d s u p p o r t e d n a t i o n w i d e by :
Gauteng & Pretoria Western, Eastern & Kwa-Zulu Natal
Central region (012) 661-2002 Northern Cape (031) 579-1895
w w w. s a m s u n g a i r. c o. z a (011) 704-6320 (021) 556-8292
Due to Samsung's policy of constant improvement, specifications are subject to change without notice. E&OE