Spherical Tank
Spherical Tank
Document No.
EQS-DST-00098
MECHANICAL DATA
Layout Loads
Vertical / Horizontal - Spherical Basic Wind Speed m/s By Vendor
Vessel Dia. (ID) mm 22500 Basic Wind Pressure N/m2 By Vendor
Tan / Tan mm N/A Earthquake Factor - By Vendor
Height of Bottom mm 2100min. (TBC) Base Shear N By Vendor
Type of Heads (Top/Bottom) Hemispherical Base Moment N-m By Vendor
Shell Thickness mm TBC AGITATOR
Head Thk (Top/Bottom) mm Download N N/A
Type of Supports - Legs Torque N-m N/A
Insulation Thk mm 40 (Hold) Bending Moment N-m N/A
Insulation Type - HC with antisweat WEIGHT
Fireproofing Hold Fabricated: kg 1,335,200
Vessel Volume m³ 5964 Empty kg 1,335,200
Liquid Volume m³ 5581 Operating (Incl. Oper. Liquid):
kg 4,004,300
Jacket / Coil Volume m³ N/A Full of Water (Field): kg 7,294,320
Heat Transfer Area m² N/A Erection: kg
`
MATERIAL DATA
Shell SA-516 Gr70 Bolts (external) SA-193 Gr B7
Heads SA-516 Gr70 Nuts (external) SA-194 Gr 2H
Jacket / Coil Shell N/A Bolts (internal) N/A
Jacket / Coil Head N/A Nuts (internal) N/A
Nozzle Flanges SA-105 Gaskets (external) Note 8
Nozzle Necks SA-106B/SA-333 Gr6 Gaskets (internal) N/A
Nozzle Pad N/A Internals(Welded) N/A
Girth Flanges N/A Internal Trays/Valves N/A
Support (Top at Shell) SA-516 Gr70 Internal Flanges N/A
Support (Lower) A36 Wear Plate(Internal) N/A
Insulation Supports SA-516 Gr70 Internal Pipe SA-106B
Stiffening Rings SA-516 Gr70 Internal Supports SA-516 Gr70
Platform / Ladder Clips SA-516 Gr70 Vortex Breaker N/A
Tailing Lugs N/A Nozzle Baffle Hood N/A
Lifting Lugs / Trunnions N/A Elbow (Internal) N/A
NOZZLE SCHEDULE
Nozzle No. Service NB Rating Flange Finish Stand Elevat Note
off. In (#) -out -ion
34 APPLICABLE SPECIFICATIONS
35 DOCUMENT
NAME Applicable/No
36 NUMBER
37 EQS-SPC-00001 Pressure Vessel Specification Applicable
38 EQS-SPC-00002 Specification for Welding &NDE for Equipment Applicable
39 EQS-SPC-00003 Material Specification for Equipment Applicable
40 EQS-SPC-00004 Specification for Pressure Testing of Equipment Applicable
41 Painting & Coating Specification Applicable
42 PMI Specification No
43 Insulation Specification No
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
Notice: This drawing has not been published and is the sole property of Fluor, and is lent to the borrower for his confidential use only, and in consideration of the loan of this drawing, the borrower agrees Document Number
to return it upon request and agrees that it shall not be reproduced, copied, lent or otherwise disposed of directly or indirectly, nor used for any purpose other than that for which it is specifically furnished. #REF!
Contract: A9OE
VERTICAL PRESSURE VESSEL Item Tag(s): D7001
1 GENERAL NOTES:
1 Process Notes
Provide vortex breaker for pump suction outlet.
5 2 One vessel required mark D7001
6 3 Vessel fabricator shall furnish and install all parts unless otherwise noted.
7 4 Blinded connections to be furnished with blind flange, studs, nuts and gaskets.
8 5 Minimum nozzle projections are from outisde of insulation of the vessel to extreme face of flange as below.
9 200 mm for NPS 4 inches and smaller.
10 250 mm for NPS 6 inches to NPS 12 inches and smaller .
11 300 mm for NPS 14 inches and larger.
12 6 All nozzle bolt holes to straddle principal vessel centerlines.
13 7 Flanged face finish to be in the range of 125 to 250 µ inch.
14 8 External flange gaskets to be spiral wound with SS304 metal winding and graphite filled with SS 304 inner and CS outer ring as per ASME B16.20.
15 9 Instrument nozzle numbers, sizes and rating to be confirmed by control system.
16 10 Process nozzles flange rating shall be verified considerining allowable nozzle loads as per UG-44 of ASME Sec VIII div 1.
17 11 Weights indicated are estimated and subject to vessel supplier confirmation.
18 12 All external attachments welded to the vessel shall be of the same grade material as the vessel.
19 13 Where "by Vendor " is specified it indicates that it is vessel suppliers responsibility to meet requirements in compliance with all applicable
20 codes , standards and specification.
21 14 Nozzles elevation and orientation to be finalized during detail engineering.
22 15 For design purpose , the minimum elevation from the grade level to bottom of the sphere shall be 2200 mm
23 16 Stilling well (4 nos.) required for the GWR level transmitters with 4-in dia pipe and 13 meters length. Length and other details will be confirmed during the
detail engineering design.
17 Minimum design metal temperature to be used as minimum temperature for mechanical design.
18 Maximum pump out rate of 30.7m3/hr represent pump rated capacity by considering both pump are operating simultaneously.
19 Parts shall be as prefabricated in Supplier’s shop as much as possible.
20 Safety valve nozzle size is on hold to be confirmed.
24 21 Spares shall include two sets of unused service gaskets and 10% (two sets minimum) extra bolting.
25 22 Vessel supplier to adhere to project specifications and standards. Same shall be provided on formal request for quotation.
26 23 Wind Load Data
27 Code: ASCE/ SEI 7-10
28 Design wind velocity, (Km/hr) : 210, Exposure: C
29 24 Seismic Load Data
30 Code: ASCE/ SEI 7-10
31 Importance Factor "I" :1.25; Earthquake Zone: 1
32 Ss- Short period (0.2 Sec) Spectral response acceleration in% g: 8.8 & S1- 1second Spectral response acceleration in% g: 3.2.
33 PGA (% Peak Ground Acceleration) % g : 3.4
Piping connected to sphere nozzles that are at the lower of sphere shall be located outside of legs. Contractor to provide the permanent support for piping up to
outside the perimeter of the legs.
34 25 Paint shall be provided as per the specification for painting
35 26 Two grounding lugs shall be provided.
36 27 Nozzle 2" and below shall be RFLWN
37 28 All removable internals shall be removable through vessel manholes unless otherwise noted.
38 29 Vacuum stiffeners to be designed and located by fabricator.
39 30 Internal elevations are top of support ring unless otherwise noted.
40 31 Supply of Ladder & Platform shall be provided by Vessel Fabricator.
41 32 Nozzle flanges shall be in accordance with ASME B16.5.
42 33 Skirt height is on hold, piping to confirm
43 34 Bore of flanges shall correspond with the internal diameter of nozzle neck unless otherwise noted.
44 35 Vessel cleats, supports, ladder & platforms requirement to be provided later.
45 36 All carbon steels for pressure containing parts shall be killed steels
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
Notice: This drawing has not been published and is the sole property of Fluor, and is lent to the borrower for his confidential use only, and in consideration of the loan of this drawing, the borrower agrees Document Number
to return it upon request and agrees that it shall not be reproduced, copied, lent or otherwise disposed of directly or indirectly, nor used for any purpose other than that for which it is specifically furnished. 000.258.DS4201
Contract: A9OE
Item Tag(s): D7001
VERTICAL PRESSURE VESSEL DATA SHEET Revision: A
Unit: 70
P.O. No.: NA
Inquiry No.: 4-0202
Sheet 6 of 7
VESSEL SKETCH
Outline of Equipment and Dimensions That Supplier Shall Hold
Notice: This drawing has not been published and is the sole property of Fluor, and is lent to the borrower for his confidential use only, and in consideration of the loan of this drawing, the borrower agrees Document Number
to return it upon request and agrees that it shall not be reproduced, copied, lent or otherwise disposed of directly or indirectly, nor used for any purpose other than that for which it is specifically furnished. #REF!