The user manual provides instructions for the ACP824P Alarm Control Panel. It has 3 sentences: The ACP824P alarm control panel has 32 zones with 8 wired zones and 24 wireless zones. It can be armed and disarmed using user codes, key fobs, phone calls, SMS messages, auto timers or central monitoring systems. When an alarm occurs, the user will be notified by phone call, SMS, GPRS or TCP/IP depending on how the panel is configured.

Uploaded by

Dedi Jannery
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
287 views33 pages

Manual ACP824P (Sept 2020)

The user manual provides instructions for the ACP824P Alarm Control Panel. It has 3 sentences: The ACP824P alarm control panel has 32 zones with 8 wired zones and 24 wireless zones. It can be armed and disarmed using user codes, key fobs, phone calls, SMS messages, auto timers or central monitoring systems. When an alarm occurs, the user will be notified by phone call, SMS, GPRS or TCP/IP depending on how the panel is configured.

Uploaded by

Dedi Jannery
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 33

ACP824P

Alarm Control Panel


User Manual

P/N:20121119-5
ACP824P WIRING DIAGRAM

LED display
on Metal case GSM LED Flash

BAT
+_

Telephone
TEL
LI NE

Tel.line
AC AC + BELL- R B G Y +12V GND Z1 GND Z2 Z3 GND Z4 Z5 GND Z6 Z7 GND Z8

13VAC 2A Aux power


output 2.2K 2.2K 2.2K 2.2K 2.2K 2.2K 2.2K 2.2K

Power Arm

Disarm Fault
Delet e Confirm
Frice Panic Medical Check

1 2 3 Arm

4 5 6 Disarm

7 8 9 Home

0 # Bypass

Power supply
Only can use12V/7A sealed lead-acid battery,change battery every 3-5 years
With 1 keypad,power consumption 250mA,support for 16 working hrs.
Total power consumption(keypad,auxiliary power,siren)can~t exceed max.power
consumption of control panel
Max.Rechargeable current of battery:350MA
User manual ACP824P

Content
Foreword 1
Features 2
Alarm procedure 3
1.Remote control by phone 4
2.Follow me operation 4
GSM remote operation 6
GSM alarm receiving 6
GSM control via SMS 6
Keypad 7
LED display on Metal case 8
Basic operation 9
System setting 10
I.Set password 11
1.1 Set administrator password 11
1.2 Set user password 11
II.set CMS number 11
2.1 Set CMS number 11
2.2 Set user Id 12
2.3 Free arm telephone number 12
2.4 Free disarm telephone number 12
2.5 Set the user telephone number 12
2.6 CMS dialing times 13
2.7 The user phone dialing time 13
III.System options 13
3.1 System time setting 13
3.2 Entry delay time setting 13
3.3 Set exit delay time 14
3.4 Siren time 14
3.5 Set ring time 14
3.6 Detector loss check 14
3.7 Communication checking interval time 15
3.8 Arm,disarm indication sound 15
3.9 Arm/disarm report 15
3.10 Panic alrm sound 15
IV. Code wireless device 16
4.1 Code wireless remote controller 16
4.2 Auto code wireless detector 16
4.3 Manual code remote controller 16
User manual ACP824P

4.4 Manual code wireless detector 17


4.5 Delete remote controller 17
4.6 Delete detectors 17
V.System zone setting 17
5.1 Zone type setting 18
5.2 Zone siren type setting 18
5.3 Wired zone loop type 18
5.4 The response speed of wireless 19
VI.Other options setting 19
6.1 AC power fault report delay 19
6.2 Time calibration 20
6.3 Force arming 20
6.4 Cross protection areas 20
6.5 Dial back specific Number 21
VII.GSM setting 21
7.1 GSM module set 21
7.2 GSM information setting 21
7.3 Alarm priorities 22
7.4 GSM message language 22
7.5 DTMF output signal strength 22
7.6 Handshake voice input signal strength 23
7.7 GPRS setting 23
7.8 Server IP address 23
7.9 Server port 23
7.10 Server registered ID 24
7.11 Server registered passwordh 24
7.12 Server connection 24
Technical specification 25
Maintenance and protection 25
Limitation of the Products 26
User manual Foreword

Foreword
ACP824P is a intelligent alarm control system which integrated
with burglarproof, fireproof, gas leak proof. It is compatible with
wired and wireless alarm mode.
ACP824P refers to the most advanced coding techniques of BUS
zone and multi-bit random code-hopping techniques in security &
reliability, to avoid false alarm and interference effectively.
1. 32 zones:8 wired, 24 wireless
2. 6 way to arm and disarm the system: User code, Key fob, Phone,
SMS, Auto timer, CMS
3. Alarm notification: When alarm occurs, user can have alarm
notification by phone call, SMS, GPRS, TCP/IP (optional)
Smart feature of ACP824P
1. Multi-zones combination alarm, special design for the places
such as watch room, bedromm and etc.
2.Can use without keypad
3.LED display on metal case, easier for user to check system info.

Warning!!!
●Don’t disassemble or modify, or else may be lead to danger and
the damage of panel.
●Be sure not to cause to break by falling or throwing down or

strong impacting. Not install near the magnetic field, may


because instability.
●Keep dry and clean. Don’t install the panel in the site which has

oily fume, water-vapour, much poudre.


●Be keep out of the sun and heat. Don’t install the panel near the

heating stove etc. high temperature equipment, such as spotlight.


Keep out of the direct sunlight, may cause color fading.
●When cleaning, wipe with the mull. To remove dirt need to use

detergent, don’t use gasoline or paint thinner etc. chemicals. Or


else may cause damage or the paint scaled off the panel.

ACP824P 1
User manual Features

Features:
Zones: 8 wired/ 24wireless
Keypad and remote: Support 8 pcs LCD keypad and 8 remotes
Password: 1 installer code, 1 duress code, 15 user codes
CMS: 2 CMS follow me numbers, 1 account number
Voice number: 4 voice numbers, Voice prompting operation
Event log: 128 event logs
Module expanded: GSM/ GPRS module
Recording:10-second automatic message Recording

2 ACP824P
User manual Alarm procedure

Alarm procedure

Tele Telephone telephone Cell phone

1st 2nd 3rd 4th

3.The panel will dial 1-4 telephone numbers


as preset.If more than 4 numbers,the panel will
start with second telephone number, then 3,4...

d
ire
W

BUS
Alarm software
Alarm situation found,
start to send message
DISARM
ALARM
POWER FAULT
COM
ARM

1.The detector activated send


alarm information to alarming center
CMS

110 alarm center


wi
re
2.The panel use Ademco Contact ID to send les
s
alarm information to alarming center.
If the panel got confirmation from center,
then alarm successfully.Otherwise, the panel
will repeat alarm.The alarm information will
be display and reslove by the alarm center computer
software.

ACP824P 3
User manual Remote control by phone

1. Remote control by phone

1 DI ~ DI ~ 2

When user answer the call,the panel


User to call landlines phone
pick up phone after preset rinings
which connect to the panel

3 4
1 2 3 4
"Welcome to your security Enter the user code as per voice
system Enter your user code" prompting(factory default
code: 1234)

System disarm, press one 5


System arm, press two
System home arm, press three
Play the zone address recording, press nine
Hang up, press zero

2. Follow me operation
When the detector is triggered, the panel will sound alarm and display the triggered
zone number and alarm type on the LCD screen. The panel will give a alarm and dial
the preset voice numbers if the panel received the alarm.
The user can hear indication after he took th e phone.The user operate follow the
voice indication to disarm/arm、inquire and mornitor .

1 POWER
OC M
DISARM

ARM
ALARM
FAULT
2

Panel receivealarm,
Send the alarm signal and dial voice number

4 ACP824P
User manual Follow me operation

User answer the call

4
Cancel the alarm press one
Check alarm zone press two
Activate the hoot press three
To disable the siren press four
Disarm system press five
Arm the system press six
Stay arm the system press seven
Play the zone address recording press nine
Hand up press zero

ACP824P 5
User manual GSM remote operation

GSM remote operation


You can SIM card number,then panel will off revised user password,the default
password is 1234,as
press 1 to disarm
press 2 to arm
press 3 to home arm
press 0 to hangup

GSM alarm receiving


When alarm occurs,GSM will call the preset voice number,it will voice prompt
“system is alarm,please process the alarm
press one to cancel alarming
press two to check alarm zone
press three to trigger siren
press five to disarm
press six to arm
press seven to home arm

GSM control via SMS


Arm command PASSWORD:1234 SYSTEM ARM

Disarm command PASSWORD :1234 SYSTEM DISARM

Home arm command PASSWORD :1234 SYSTEM HOME

Status checking command PASSWORD :1234 SYSTEM STATUS

Cancel alarm command PASSWORD :1234 SYSTEM CANCEL

Note:There is no space in the command“password:1234”,There is a space between


system and arm.enter“system arm”,when operate successfully,SMS auto reply
“Arm Successful”.

Set GPRS access command PASSWORD :1234 APN:“aaaaaa”

Set GPRS access User name command PASSWORD :1234 USER:“bbbbbb”

Set GPRS access User code command PASSWORD :1234 PWD:“cccccc”

   “ 
Remarks:There is no space between APN:

6 ACP824P
User manual Keypad

Keypad description

Power LED Power Arm Arm LED


Disarm LED Disarm Fault Fault LED
Delete Confirm
Frice Panic Medical Check

1 2 3 Arm

4 5 6 Disarm

7 8 9
Speech indication
Numeric keyboard Home

0 # Bypass

Power LED: it will normal ON when AC and battery without any trouble. It will off
when both AC and battery with trouble. It will slow flash when battery
with trouble, it will quick flash when AC with trouble.
Fault LED: It will slow flash when communication with trouble, it will off when
without any troubles.
Arm LED: It will ON when armed, slow flash when stay in, quick flash when alarm.
Disarm LED: It will ON when disarmed, it will OFF when zone trouble.

Fire : The panel will send out alarm Check : Press CHECK key to check the
signal when press FIRE key 3 for alarm events , it used as Confirme
seconds, it used as UP key when key when programming.
programming.
: W hen y ou e ntering n umbers,
Panic : The panel will send out alarm
press *, the LCD screen will
signal when press PANIC key for 3
seconds, it used as DOWN key display P, means 2s pause
when programming. when dialing, for other settings,
press * means EXIT.
Medical : The panel will send out alarm
signal when press HELP key for 3 # :When enter errors, press # can
seconds, it used as DELETE key delete the errors, it used as
when programming. Confirm key when programming.

Basic operation
Factory default Admin password: 012345
Factory default User password: 1234
Arm: User password [1234]+ Arm

Home: User password[1234]+ Home

Disarm: User password[1234]+ Disarm

Bypass: User password[1234]+ Bypass + zone number + #

ACP824P 7
User manual LED display on Metal case

#
Enter system setting : Admin password[012345]+
+ #
* +[0]+
Exit system setting:
*
Password reset: You can enter installer code 000000 to enter setup only during the
first 1 minute when the alarm is powered on.

8 ACP824P
User manual Basic operation

Basic operation
☆Arm ☆ Disarm
Power Arm
~嘀~ Power Arm
~嘀~
Disarm Fault Disarm Fault
Delete Confirm Delete Confirm
Frice Panic Medical Check Frice Panic Medical Check

1 2 3 Arm 1 2 3 Arm

4 5 6 Disarm 4 5 6 Disarm

7 8 9 Home 7 8 9 Home

0 # Bypass 0 # Bypass

Y Y

M D M D

User code[1234] + Arm or the away User code [1234] + Disarm or the

ARM button in the keyfob DISARM button on the keyfob

☆ Emergency ☆ Stay arm


~ di ~ di ~ ~ di ~ di ~
Power Arm Power Arm

Disarm Fault Disarm Fault


Delete Confirm Delete Confirm
Frice Panic Medical Check Frice Panic Medical Check

1 2 3 Arm 1 2 3 Arm

4 5 6 Disarm 4 5 6 Disarm

7 8 9 Home 7 8 9 Home

0 # Bypass 0 # Bypass

Y Y

M D M D

Emergency help:press key in the keyfob User code + Stay or press the home
or press Panic and hold for 3s ARM key in the keyfob.

Note: If the LCD also display zone alarm when the user disarmed the system after
alarming, please disarm the system again, then LCD display will resume.

ACP824P 9
User manual System setting

System setting
[012345] + + [0] + #
*
System setting display

2 0 6 0 5

Programming address Set data Data bit

System menu and programming address


01-- Set admin password 51-- Set siren type
02-- 17Set user password 52-- Wired zone loop type
20--21 Set CMS 53-- Wired zone response time
22-- Set user No. 60-- Force arm
23--26 Set user phone number 61-- Call back specified number
27-- Set CMS dialing times 62-- Set free arm phone number
28-- Set user phone dialing times 63-- Set free disarm phone number
30-- Set system time 70-- The first group cross zone
31-- Set enter delay time 71-- The second group cross zone
32-- Set exit delay time 72-- The third group cross zone
80-- Set GSM
33-- Siren time
81-- Set GPRS
34-- Ring times
82-- Alarm priority
35-- Check sensor loss
83-- Set GSM info
36-- Communication testing time
84-- Server IP address
37-- Arm/disarm tone
85-- Server port
38-- Arm/disarm report
86-- Server register ID
39-- Panic alarm tone
87-- Server register password
40-- Auto program remote 88-- Server connection mode
41-- Auto program sensor 89-- DTMF output signal strength
42-- Enter remote code 90-- Handshake tone input signal
43-- Enter sensor code strength
44-- Delete remote 91-- SMS language
45-- Delete sensor 98-- AC off delay report
50-- Set zone type 99-- Time calibration

10 ACP824P
User manual Set password

I.Set password
1.1 Set administrator password
For example: set the administrator password as 112233, the factory default password
is 012345.

[012345] +
* + [0] + # ---- + [01] + [112233]
Password
LCD screen display
01 3 06 + #
LCD screen display
Press # return to standby interface
* +

1.2 Set user password(the factory default password:1234)


For example:set the NO.3 user password as 5678

[012345] +
* + [0] + # ---- + [04] + [5678]

04 8 04 + #

# return to standby interface


Press
* +

NOTE:User can set 16 user passwords,the program address:02-17

II.Set CMS number


2.1 Set CMS number
For example:set the CMS number as 9P80012345

[012345] +
* + [0] + # ---- + [20] + [9 80012345]
Program *Telephone
address number
20 11 + #

# return to standby interface


Press
* +

Note: user can set 2 CMS numbers,the program address:20-21,when press


LCD screen dispaly asP,it means dial pause 2 seconds.
*
The dial pause only for connecting with extensions, otherwise,press 80012345 directly.

ACP824P 11
User manual set CMS number

2.2 Set user ID(the factory default setting :0000)


Example: set the user ID as 6666

[012345] +
* + [0] + # ---- + [22] + [6666]
Program User ID
LCD screen address
22 05 + # display

LCD screen dispaly


Press # return to standby interface
* +

2.3 Free arm telephone number


Example: set the free arm telephone number as 84113252

[012345] +
* + [0] + # ---- + [62] + [ 84113252 ]

62 09 + #
Press # return to standby interface
* +

2.4 Free disarm telephone number


Example: set the free disarm telephone number as 84113268

[012345] +
* + [0] + # ---- + [63] + [ 841132 68]

63 09 + #
Press # return to standby interface
* +

2.5 Set the user telephone number


Example: set the NO.3 user telephone number as 93872105

[012345] +
* + [0] + # ---- + [25] + [93872105]

25 09 + #
Press # return to standby interface
* +

Note:user can set 4 user telephone numbers,the program address:23-26。

12 ACP824P
User manual system options

2.6 CMS dialing times.The default setting is 5 times


Example:set the dialing time as 4 times.

[012345] +
* + [0] + # ---- + [27] + [04]

27 4 02 + #
Press # return to standby interface
* +

2.7 The user phone dialing time:the default setting is 5 times


Example: set the dialing time as 3 times

[012345] +
* + [0] + # ---- + [28] + [03]

28 3 02 + #
Press # return to standby interface
* +

III.System options
3.1 System time setting
Example: set the system time and date as 10:01,July,11,2012

[012345] +
* + [0] + # ---- + [30]

+ [1207111001]
Y M D H M
30 1 10 + #
Year Month Day Hour Minute
Press # return to standby interface
* +

3.2 Entry delay time setting:after triggerd the delay zone,panel start
alarming.the default setting is 10 seconds.
Example: set the entry delay time as 15 seconds.

[012345] +
* + [0] + # ---- + [31] + [015]
Program Time
LCD screen address
31 5 03 + # dispaly
LCD screen dispaly
Press # return to standby interface
* +

ACP824P 13
User manual system options

3.3 Set exit delay time:the default setting is 10seconds.


Example: set the exit delay time as 15 seconds.

[012345] +
* + [0] + # ---- + [32] + [015]

32 5 03 + #
Press # return to standby interface
* +

3.4 Siren time(the default setting is 5mins)


Example: set the siren time as 10 mins

[012345] +
* + [0] + # ---- + [33] + [10]

33 0 02 + #
Press # return to standby interface
* +

3.5 Set ring time(the default time is 7times)


Example: set the ring time as 5 times.

[012345] +
* + [0] + # ---- + [34] + [05]
Program Time
LCD screen address
34 5 02 + # dispaly

LCD screen dispaly


Press # return to standby interface
* +

3.6 Detector loss check(the default setting is00 as Disable)


Example:set the detector loss check time as 4hours

[012345] +
* + [0] + # ---- + [35] + [04]

35 4 02 + #
Press # return to standby interface
* +

14 ACP824P
User manual System options

Note: wireless detector send status report about every 3 hours. The panel check if receiver
the status report signal or alarm signal from detector at programed time. If not
receive the singal, will judge detector loss. We suggest set the neterval time of
detector inspection longer than 4 hours.
3.7 Communication checking interval time :
It is checking of communication between alarm panel and CMS. To check if the
communication is normal(default is 00, not checking)
Example: set the communication checking interval time as 15 hours.

[012345] +
* + [0] + # ---- + [36] + [015]

36 5 03 + #
Press # return to standby interface
* +

3.8 Arm, disarm indication sound :


To set if the siren sound when user use remote controller to arm,disarm the panel
(default: not sound)
0> not sound 1>sound
Example: set the arm /disarm indication sound on

[012345] +
* + [0] + # ---- + [37] + [1]

37 1 01 + #
# return to standby interface
Press
* +

3.9 Arm/disarm report(default: not report to CMS)


0> not report 1> report
Example: set arm/disarm report CMS

[012345] +
* + [0] + # ---- + [38] + [1]
Program 1>Report
LCD screen address
38 1 01 + # dispaly
LCD screen dispaly
Press # return to standby interface
* +

3.10 Panic alrm sound:


To set if the siren sound when trigger the panic button on remote controller or
emergency button on keypad(default: OFF)
0> OFF 1> ON

ACP824P 15
User manual system options

Example: set the panic alarm sound on

[012345] +
* + [0] + # ---- + [39] + [1]

39 1 01 + #
Press # return to standby interface
* +

IV. Code wireless device


4.1 Code wireless remote controller
Example: auto code number 5 remote

[012345] +
* + [0] + # ---- + [40] + [5]

40 5 01 + # 40 1 01 + #
Trigger remote 1 01 is the first number of
controller remote is 9 digit address code

# return to standby interface


Press
* +

4.2 Auto code wireless detector


Example: auto code number 9 wireless detector

[012345] +
* + [0] + # ---- + [41] + [09]

41 9 02 + # 41 2 01 + #
2 01 is the first number of
Trigger wireless is 9 digit address code
wirelers detector
# return to standby interface
Press
* +

4.3 Manual code remote controller


Example: manual code the first remote controller by enter address code of remote
077230023

[012345] +
* + [0] + # ---- + [42] + [1]

42 1 01 + # [077230023] 41 3 09 + #

Press
* + # return to standby interface

16 ACP824P
User manual System zone setting
User manual

4.4 Manual code wireless detector


Example: manual code the number 24 wireless detector by enter the address code
035126025

[012345] +
* + [0] + # ---- + [43] + [24]

43 4 02 + # [035126025] 43 5 09 + #

# return to standby interface


Press
* +

4.5 Delete remote controller


Example: delete the number 8 remote controller

[012345] +
* + [0] + # ---- + [44] + [8]
Program Address
LCD screen address code
44 8 01 + # dispaly
LCD screen dispaly
# return to standby interface
Press
* +

Note: enter 0 to delete all remote controller


4.6 Delete detectors
Example: delete number 11 detector

[012345] +
* + [0] + # ---- + [45] + [11]
Program Address
LCD screen address code
45 1 02 + # dispaly
LCD screen dispaly
# return to standby interface
Press
* +

Note: enter 00 to delete all detectors


V.System zone setting
5.1 Zone type setting
Options of zone type as below
0>disable 1>delay 2>perimeter
3>burglar 4>24 hours 5> emergency
6> fire alarm
For example: set protection area 7 and 8 as one group of the double direction one-shot
mode cross protection area. Preset time is 50 seconds.

ACP824P 17
User manual system zone setting

Burglar alarm zone only trigger under system arm status, delay and perimeter zone
trigger under stay or arm status.
24 hours, emergency and fire alarm zone will trigger under any system status

Factory default:
Wired zone 1-8 enable, wireless zone 9-32 enable, bus zone 33-64 disable, 00 is system
zone. Pls connect resistor 2.2k to wired zone before power on the alarm panel, otherwiset
he alarm panel will make alarm or cause zone trouble. When need use bus zone, 7601 one
zone expand module is required.
Example: set the number 59 zone as fire alarm zone

[012345] +
* + [0] + # ---- + [50] + [59]
Program Zone
LCD screen address
+ [6] 50 6 03 + # dispaly
Type
LCD screen dispaly

# return to standby interface


Press
* +

Note: If only check the zone type, then enter zone number, then press # button.
The LCD will display the zone type.
5.2 Zone siren type setting(default continious sound)
The options of siren type:
0>mute 1> continious sound 1> pulse tone
Example:set zone 33 siren type as pulse tone

[012345] +
* + [0] + # ---- + [51] + [33]
Program Zone
LCD screen address
+ [2] 51 2 03 + # dispaly
Type
LCD screen dispaly
Press + # return to standby interface
*
Note: if only check the zone siren type, enter zone # , then press # button,
the LCD will display the siren type

5.3 Wired zone loop type(default: resistor loop)


The options of wired zone loop type:

0>N.O loop, zone open loop normal, short-cut loop alarm


1>N.C loop, zone short-cut loop normal, open loop alarm

18 ACP824P
User manual Other options setting

2.2KΩ NC
Z Z
NO 2.2KΩ

C C
Eol resistor N.G wiring Eol resistor N.O wiring

For example: set the protection area No.6 as N.C loop

[012345] +
* + [0] + # ---- + [52] + [6]

+ [2] 52 2 02 + #

# return to standby interface


Press
* +

Note: if only see the loop type in the wired protection area, press # to display the
loop type after inputting the protection area number
5.4 The response speed of wireless protection area (default is 500ms)
Configurable response speed of wireless protection area as below
For example: set the response speed for protection area No.3 is 10ms, Screen shows

[012345] +
* + [0] + # ---- + [53] + [3]
Program Zone
LCD screen address
+ [1] 53 1 02 + # dispaly
1>10ms
LCD screen dispaly

# return to standby interface


Press
* +

Note: If only can see the response speed of wireless areas, after inputting the protection
areas No. and press # , it will display the response speed. The common detector’
s response speed is 500ms, 10ms for High speed detectors and vibration sensors.

. VI.Other options setting


6.1 AC power fault report delay: when there is AC power fault occurs, the
delay time for reporting to the alarm receiving centre default for 30 minutes.
For example: set the delay time of AC power fault report is 5 minutes

[012345] +
* + [0] + # ---- + [98] + [05]

98 5 02 + #

Press # return to standby interface


* +

ACP824P 19
User manual Other options setting

Note: if the delayed time setting is 0 minutes, it means that it will not report the power
fault information.
6.2 Time calibration
For example: If the panel time every 24 hours fast 20 seconds, take the formula
20x100/24=83 to calibrate, then set this value is 083. If slows 20 seconds, then
it is 183 to calibrate the time.

[012345] +
* + [0] + # ---- + [99] + [083]

99 3 03 + #

# return to standby interface


Press
* +

6.3 Force arming: Allow users to arm when protection area faults. In the state of
the arming, the protection areas and recovery information will report to alarm
receiving centre. Default is disable.
0>Disable force arming 1>Enable force arming
For example: set enable force arming

[012345] +
* + [0] + # ---- + [60] + [1]

60 1 01 + #

# return to standby interface


Press
* +

6.4 Cross protection areas: protection area 1+protection area 2 + time + mode.
Configurable cross protection area mode as below
0>Cancel cross model
1> The double direction twice-trigger mode : single trigger protection area 1, 2,
it will not alarm, trigger first protection 1, then trigger protection area 2 within
preset time, it will alarm; first trigger protection area 2 then area 1, it will not alarm.
2>The double direction One-Shot mode: trigger protection area 1, protection area 1
alarm; trigger protection area 2 first then protection area 1 within preset time, then
it will not alarm; trigger protection area 1 behind the preset time, the protection
area 2 will alarm.
3>Twice-trigger alarm mode: one-shot trigger protection are 1 or 2, it will not alarm,
trigger protection area 1 and 2 in preset time separately, then protection area 1 and
2 alarm.

20 ACP824P
User manual GSM setting

[012345] +
* + [0] + # ---- + [70] + [07080502]
Zone 1 Time Mode
70 2 08 + # Zone 2

Press # return to standby interface


* +

Note: It can set 3 groups of cross protection areas. The corresponding No is 70-72
6.5 Dial back specific No. : dial telephone No. that connected with panel, input the
# + administrator’s password after off-hook. It will be on-hook automatically
and the panel will call the preset the telephone No. which can execute the arm and
disarm operation in a long distance.
For example: set the dial back telephone No. is 12345678.

[012345] +
* + [0] + # ---- + [61] + [12345678]

61 09 + #

Press # return to standby interface


* +

VII.GSM setting
7.1 GSM module set (default is disable)
For example: set enable GSM module.Configurable GSM information as below.
0>Disable 1 > Enable

[012345] +
* + [0] + # ---- + [80] + [1]

80 1 01 + #
LCD screen dispaly
Press # return to standby interface
* +

7.2 GSM information setting (default is SMS + voice calling)


0 > SMS + voice calling 1 > SMS 2> Voice calling
For example: set only can dial voice calling.

ACP824P 21
User manual GSM setting

[012345] +
* + [0] + # ---- + [83] + [2]
Program Type
LCD screen address
83 2 01 + # dispaly

LCD screen dispaly


Press # return to standby interface
* +

7.3 Alarm priorities (default is GSM priority)


0>GSM priority 1 > PSTN priority
For example: set telephone line is priority

[012345] +
* + [0] + # ---- + [82] + [1]

82 1 01 + #
Press # return to standby interface
* +

7.4 GSM message language (default is Chinese)


Configurable SMS language as below
0>Chinese 1>English
For example: set message as English

[012345] +
* + [0] + # ---- + [91] + [1]

91 1 01 + #
Press # return to standby interface
* +

7.5. DTMF output signal strength(default is 04)


For example: set DTMF output signal strength is 05

[012345] +
* + [0] + # ---- + [89] + [05]
Program Signal
LCD screen address stregth
89 5 02 + # dispaly

LCD screen dispaly


Press # return to standby interface
* +

22 ACP824P
User manual GSM setting

7.6 Hand skake voice input signal strength (default is 60)


For example: set handshake voice input signal strength is 70

[012345] +
* + [0] + # ---- + [90] + [70]

90 0 02 + #
Press # return to standby interface
* +

7.7 GPRS setting (default is disable)


0> Disable 1>Enable
For example: set enable GPRS function.

[012345] +
* + [0] + # ---- + [81] + [1]

81 1 01 + #

Press # return to standby interface


* +

7.8 Server IP address


For example: set Server IP address is 202.101.78.2

[012345] +
* + [0] + # ---- + [84]

+ [202101078002] 84 2 12 + #
Press # return to standby interface
* +

7.9 Server port


For example: set Server port is 03467

[012345] +
* + [0] + # ---- + [85] + [03467]

85 7 05 + #
Press # return to standby interface
* +

ACP824P 23
User manual GSM setting

7.10 Server registered ID


For example: set server registered ID is 75640001

[012345] +
* + [0] + # ---- + [86] + [75640001]
Program User ID
LCD screen address
86 1 08 + # dispaly

LCD screen dispaly


Press + # return to standby interface
*
7.11. Server registered password
For example: set Server registered password is 12345678

[012345] +
* + [0] + # ---- + [87] + [12345678]

87 8 08 + #
Press # return to standby interface
* +

7.12 Server connection (default is long connection)


Configurable comection method mode as below
0> Long connection 1> Short connection
For example: set connection is short one

[012345] +
* + [0] + # ---- + [88] + [1]

88 1 01 + #
Press # return to standby interface
* +

Note: Enable GPRS function need to enable GSM module.


Long connection: do not deal with SMS, voice calling and Server, via GPRS
long connection.
Short connection: when it have voice calling and SMS, the system will cut off connection
with GPRS, and deal with the voice calling and SMS priority. When this is done, GPRS
will connect with Server automatically.
Server registered ID and password: GPRS can registered must have the correct ID and
password that registered in the Server. it must be 8 digitals for the ID and passwords.

24 ACP824P
User manual Technical specification

Technical specification
General data
External AC power supply vdtage: Input:
185~230VAC
Output: 13VAC/2A
Backup battey(optiond): 12V/7AH
The method of alarming dial:Telephone alarm 、 GSM alarm and
GPRS alarm
DTMF dial frequency variation :< 1.5%
Backup power supply duration:16 hours
Communication Protocol with CMS: Ademco Contact ID
Frequency: 433MHz/868MHz
E Signal transmit distance: 100 to 120 meters (open area)
Operation temperature range: 32F to 120F(0℃ to 45℃ )
Storage temperature range: -4F to140F(-20℃ to 60℃ )
Relative humidity:85% at 30 (86F)

Maintenance and protection


Regular test
Design of components of the system is to reduce maintenance
cost, but still it is suggested that periodical check may be
carried out.
The cleanliness of control main machine
Main control panel maybe be stained by fingers or covered by
dust after using for a while. Use soft cotton cloth or sponge to
clean it. Don't use any lubricant, liquor such as kerosene, acetone
and strong gel which will damage appearanceand the tran
sparency of top window.
ATTENTION: Don't use any lubricant, liquor such as kerosene,
acetone and strong gel which will damage appearance and the
top transparency of window.

ACP824P 25
User manual Limitation of the Products

Limitation of the Products


Although the products is a high standard products, there is also
some limitation of them such as false alarm or no alarm, the
reasons may be below:
Lack of Maintenance. The system needs maintenance and test
regularly test. The sensitive of the detectors may decrease and
the siren may not whistle.
Lack of power supply If no power input and the back up power
is not enough, the panel can not work normally.
Telephone Line False If the telephone line is cut, the panel
could not send alarm signals
Limitation of Smoke Detectors if the smoke is far from the
smoke detector, the detector could not alarm
If the intruder break in through some door or window not
monitored, or some one knows hot to make the system not
work.