1. The monitor board displays status information for an elevator system through LED lights. 2. It shows status codes, input signals, error codes, software versions, and allows control of functions like door open/close. 3. The key board allows navigation of menu options to view parameters, statuses, input values, error logs, and settings for the elevator.

Uploaded by

Ahmed
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
150 views33 pages

05 - SNP - Monitor Board - r0

1. The monitor board displays status information for an elevator system through LED lights. 2. It shows status codes, input signals, error codes, software versions, and allows control of functions like door open/close. 3. The key board allows navigation of menu options to view parameters, statuses, input values, error logs, and settings for the elevator.

Uploaded by

Ahmed
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 33

Monitor Board

◆ Monitor Board

Display Meaning Remark

Community, communication, flash-communication is connected


Monitor
Supervisory panel

CPU working condition Rapid flashing -normal


medium speed –in self study
State
slow -elevator fault
no flash -contact manufacturer

CAN Cabin/shaft communication Flash-communication connected


Duplex/group control
Group Flash-communication is connected
communication
INS/NOR Inspection/automatic mode Light on-auto/light off-inspection

Encode Rotary encoder Light on-speed feedback

Safety Safety circuit Light on-safety circuit is connected

DL Door lock Light on-door lock is connected

HDL Hall door lock Light on-hall door lock is connected


Monitor Board

◆ Function of Key Board

F1 F2

MENU

( Main Board )
ESC ENTER

( Key Board )
Monitor Board

◆ Monitor Board - Menu


Number of operation Error codes Time (Year)

 

Shaft Data Time Time (Date)

 

Input Status (GX, HX) Log-in Operation status code

 
Monitor Board

◆ Monitor Board - Menu


Operation status code Parameter Floor number (IND)

 

Call command Parking floor setting Input Status (X)

 

Shaft teach Front door allow Rear door allow

 
Monitor Board

◆ Monitor Board - Menu


Software version-1 Software version-1
Rear door allow

 

Car status Software version-2 Software version-2

 

Running speed Reset parameter Reset error codes

 
Monitor Board

◆ Monitor Board - Menu

Number of operation LED Menu Door

F1 : Open command
F2 : Close command
Monitor Board

◆ LED

( Main Board )
Monitor Board

◆ Function of Key Board

F1 F2

 or
MENU

ESC ENTER

( Key Board )
Monitor Board

1. Error code

The AIO may store 20 failure codes. The most recent failure code is under No. 00.
Use up and down keys to view these failure codes. Press “Enter ”to view the date
of failure, press “left” and “right” to view the time and floor of the failure, and press
“ESC” to exit.

& : Error Code & : Time, floor


Monitor Board

2. Shaft Data (Hoistway Parameter)

&
Monitor Board

3. Input Status of SM.02/G & SM.02/I

The figure above means: GX0 has no input. Press "up“ and "down" keys to select GX serial
number from 0 to 15. After the GX matching numbers is selected, the highest level shows that
the input has no valid input (0 for no valid input, 1 for valid input).
Monitor Board

4. Input Status of Car top board

The figure in the lowest order of LED


display start to flash, use up or down
button to select the needed figure

If the password inputted is correct, the word


“login” will display on the screen after pressing
the enter button
Monitor Board

5. Process Diagnosis (Status)


This menu displays the current status of
the elevator by a two-digit number
Monitor Board

6. Parameter

Parameter or

Data
Monitor Board

7. Floor number display

1st floor

Number displays “1”


Monitor Board
Monitor Board
Monitor Board

8. Command Registration

Press “up” and “down” to select the floor to


be commanded; press “Enter” to confirm and
the command is registered.

Press “Enter”
Car will go to 1st floor

Press “Enter”
Car will go to 5th floor
Monitor Board

9. Parking floor setting


Monitor Board

10. Shaft teach


Monitor Board

11. Version of Software


Monitor Board

12. Elevator running status


Monitor Board

13. Speed of Elevator (1.75 m/sec)


Monitor Board

◆ Function of Key Board

MENU

( LED Function Selection ) ( Door Open/Close Control )


Monitor Board

◆ LED 00
Display Code Contends Displayed Remark

L1 Door lock relay input signal Start condition for


inspection. That the
Main contactor contact input signal
L2 8 lights are all on
(without contactor lighting)
indicates normal
Brake contactor contact input signal peripheral signal
L3
(without contactor lighting) and inspection can
L4 Brake switch (light if input point is normal) go on.

L5 Motor overheated (light if input point is normal)

L6 Upper limit switch (combined) status signal)

L7 Lower limit switch (combined) status signal)


LED 00
Inspection upwards/downwards signal
L8
(with signal lights)
L10 Main contactor drive signal

L11 Enable signal


Internal state of
L12 /down signal
Up/ inspection. The 6
lights will be on in
L13 Operation signal for drive feedback movement order in normal
inspection.
L14 brake contactor drive signal

L15 Whether speed curve is given or not


Monitor Board

◆ LED 01
Display Code Contends Displayed Remark

L1 Down limit switch status-lights off cannot go down Status of


Hoistway switch
Downwards one floor forced deceleration switch
L2 and leveling switch.
on/off
The light
Downwards two floors forced deceleration switch connection of
L3
switch on/off peripheral input
Downwards three floors forced deceleration switch point.
L4
switch on/off
Downwards four floors forced deceleration switch
+ ENTER L5
switch on/off
LED 01
L6 Upwards one floor forced deceleration switch on/off
L7 Upwards two floors forced deceleration switch on/off
Upwards three floors forced deceleration switch
L8
on/off
L9 Upwards four floors forced deceleration switch on/off
Upper limit switch status-lights are off and lift cannot
L10
go up
L11 Upper leveling switch on/off
L12 Lower leveling switch on/off
Monitor Board

◆ LED 02
Display Code Contends Displayed Remark
Door lock relay (X17/parameter setup –if it is not in Running start
L1
normal light) condition of high
Main contactor contact input signal (without contactor speed. That all the
L2 11 lights are on
lighting)
indicates normal
Brake contactor contact input signal (without
L3 peripheral signal
contactor lighting)
and meets the start
L4 Brake switch requirements.
L5 Motor overheated

+ ENTER L6 Upper limit switch (combined) status signal


L7 Lower limit switch (combined) status signal
LED 02 L8 Door closing limit switch signal (front/rear door)
L9 Ligths on when interal startup fails
L10 Front orientation has invalid signal registration
L11 Automatic high speed status signal
L12 Main contactor drive signal Internal state of the
L13 Enable signal running of high
speed. The 6 lights
L14 Up/down signal
will be on in order
L15 Drive feedback operation signal when the high
L16 Brake contactor drive signal speedis in normal
L17 Whether speed curve is give or not operation.
Monitor Board

◆ LED 03
Display Code Contends Displayed Remark

L1 Front door opening limit on/off The door/close


Related signal
L2 Front door closing limit on/off
Light on indicates
L3 Rear door opening limit on/off The connection of
L4 Rear door closing limit on/off peripheral point
L5 Front door safety edge switch on/off
L6 Rear door safety edge switch on/off
L7 Front door screen switch on/off

+ ENTER L8 Rear door screen switch on/off


L9 Overload switch on/off
LED 03
L10 Door opening button signal
L11 Door closing button signal
L12 Door opening signal of this floor
L13 Lights on in attendant or independent status
L14 Light on in fireman operation status
L15 Front door opening output
L16 Front door closing output
L17 Rear door opening output
L18 Rear door closing output
Monitor Board

◆ LED 04
Display Code Contends Displayed Remark

L1 Main contactor contact input on/off Contact detection


related signal, light
L2 brake contactor contact input on/off on indicates the
connection of
L3 First brake inspection switch contact input on/off peripheral input
point.
L4 Second brake inspection switch contact input on/off

L5 Safety loop high voltage point input on/off


LED 04
+ ENTER L6 Safety loop relay contact input on/off

L7 Door lock loop high voltage point input on/off

L8 Door lock relay contact input on/off

L10 Main contactor drive output

L11 Brake contactor drive output


Monitor Board

◆ LED 05

Display Code Contends Displayed Remark

L1 Down limit switch status Main input


signal logic state.
L2 Downwards one floor forced deceleration switch on/off

L3 Downwards two floors forced deceleration switch on/off

Downwards three floors forced deceleration switch


L4
on/off

L5 Downwards four floors forced deceleration switch on/off


+ ENTER L6 Upwards one floor forced deceleration switch on/off

LED 05 L7 Upwards two floors forced deceleration switch on/off

L8 Upwards three floors forced deceleration switch on/off

L9 Upwards four floors forced deceleration switch on/off

L10 Upper limit switch status

L11 Up leveling switch status

L12 Down leveling switch status

L13 /fireman operation switch


Firefighting return/

L14 Motor overheated signal


Monitor Board

◆ LED 06

Display Code Contends Displayed Remark


~X17 status
Corresponding input point: X0~ Mother board input
point disconnected,
L1
light on indicates
LED 06 ~
the connection of
L18
peripheral input
point.

+ ENTER
Monitor Board

◆ LED 07

Display Code Contends Displayed Remark

L1 Door lock relay (X17/parameter setup-if no normal light Start condition for
hoistway self
Main contactor contact input signal (without contactor
L2 study. That all the
lighting)
9 lights are on
Brake contactor contact input signal (without contactor indicates normal
L3
lighting) peripheral signal
L4 Brake switch and hoistway self
study may start.
L5 Motor overheated
+ ENTER L6 Upper limit switch (combined) status signal

LED 07 L7 Lower limit switch (combined) status signal

L8 Door closing limit switch signal (front/rear door)

L9 Ligths on when interal startup fails

L10 Self study command 1 Internal state of


the hoistwayself
L11 Next floor strong/slow status
study. The 6
L12 Lower leveling switch status lights will be on in
L13 Upper leveling switch status order during self
study.
L14 Self study command 2
L15 Self study startup
Monitor Board

◆ When parameter F165’s(Door opening/closing control) Bit3 is set to 1, it activates LED


operator’s door opening/closing function. In this screen, when press F1, the system will
output door opening signal; when press F2, the system will output door closing signal.

◆ Parameter : F165 Door open prohibit


BIT 0 Inspection mode door open or not
BIT 1 Normal mode door open or not
BIT 2 Base floor door open or not
BIT 3 control the door with monitor board