VL2900 Inverter Instruction
VL2900 Inverter Instruction
VL2900 Series
Quick Guide
Contents
02、Product Information------------------------------------- 4
03、System Connection--------------------------------------------8
05、Basic Operation------------------------------------------------ 23
06、List of parameters----------------------------------------------27
Thank you for choosing the VL2900 series ozone power supply.
At the same time, you will enjoy our comprehensive and sincere service for you.
Here accepts no liability for any consequences resulting from negligent or incorrect
installation or parameter adjustment of the Products.
Please strict adherence to this instruction is required to ensure a high level of safety. If
in doubt, please consult with ours.
VL2900 series of high-performance Ozone Power Simple Manual 1
DANGER:indicates that failure to comply with the notice will result in severe personal injury or even death.
WARNING:indicates that failure to comply with the notice will result in personal injury or property damage.
ATTENTION:If the operation is wrong, it may result in moderate or minor injury, and equipment damage。
Please kindly be noted that these three kinds of mark relates to the safety.Any violation of these rules might lead to death
or injury, damage of machine and its system. In addition, we will be not responsible for any personal hurt or damage of
machine which is due to violation of principle mentioned in this manual.
Before installation
● Do not install the equipment if you find water seepage, component missing or damage upon
unpacking.
DANGER ● Donot installthe equipment ifthe packing listdoes not conform tothe product you received.
● Do not touch the components with your hands. Failure to comply will result in static electricity
damage.
● When handling the ozone power supply, be sure to hold on to the shell. If you grab the
front cover plate to carry the ozone power, the main body of the ozone power will fall,
there is a risk of injury.
●Handle the equipment with care during transportation to prevent damage to the
equipment.
WARNING
● Do not use the equipment if any component is damaged or missing Failure to comply
will result in personal injury.
● The device has been tested for withstand voltage before leaving the factory. No
voltage withstand test can be carried out on any parts of the ozone power supply. And
High Voltage may lead to ozone power insulation and internal device damage.
During installation
● Donot loosenthe fixed screws of the components, especiallythe screws with red mark.
● Refitting Ozone Power supply is strictly prohibited.The modified ozone power supply may
DANGER
pose a risk of electric shock.If your company or your company's customer has carried on the
transformation to the product, our company will not assume any responsibility.
● Do not install,maintain,inspect or replace parts unless you are an electrical professional. Or
WARNING
there's a risk of electrocution.
● Use a shielded cable for the encoder, and ensure that the shielding layer is reliably grounded.
● Do not install transformers and other electromagnetic waves or interference devices in the
ATTENTION
ozone power supply around, otherwise it will lead to ozone power supply misoperation.If you
need to install such equipment, should set shield plate between it and the ozone power supply.
2 01,Safety Information and Precautions
At wiring
● Do not operate the connection when the power is connected, otherwise there will be
electric shock.Before checking, please cut off the power supply of all equipment. Even if
the power supply is cut off, there is residual voltage in the internal capacitor. Please wait at
DANGER
least 10 minutes after power is cut off.
● The contact current of the ozone power supply is greater than 3.5 ma, please make sure
that the ozone power supply is well grounded. There's a risk of electrocution.
● Do not connect the power supply to the output terminal of the ozone power supply.
Otherwise, it will cause the ozone power supply to be damaged, even may cause the fire.
● Some systems may operate mechanically when energized, and there is a risk of death or
serious injury.
● Before connecting the ozone power supply, please make sure that the ozone power
supply cover plate is firmly installed and the motor is allowed to restart.
WARNING ● Before connecting the ozone power supply, please confirm whether the rated voltage of
the ozone power supply is consistent with the power supply voltage.
● If the main circuit power supply voltage is used in error, there will be a fire risk.
● It is forbidden to connect the input power supply to the output terminals (U, V, W) of the
ozone power supply. OTHERWISE CAUSE OZONE POWER DAMAGE!
● The brake resistance must not be directly connected to the DC bus (P +) , (N -) terminals.
Or there will be a fire!
● When using ozone power supply, please follow the steps required by electrostatic
prevention measures (ESD) , otherwise it will damage the ozone power supply.
● Please follow the local standards, take certain branch, Short Circuit Protection
Measures. If the protection measures are not appropriate, it may cause the ozone power
supply to be damaged.
● The ozone power supply is suitable for short-circuit current below 100ka, the maximum
voltage is 440VAC (400V class) circuit.
ATTENTION ● Please do not share the ground wire with the welding machine or the power machine
which needs high current, otherwise it will cause the ozone power source or the machine to
act badly.
● When using more than one ozone power supply, take care not to make the ground wire
into a loop. Otherwise, it will cause the Maloperation of the ozone power supply or the
machine.
● Do not connect or operate if the machine is visibly damaged or parts are missing.
● The wiring, the inspection and so on please operate by the professional personnel.
After power-on
● Do not open the cover plate when the power is on. OR YOU'LL GET ELECTROCUTED!
● Do not touch any input or output terminals of the ozone power supply. OR YOU'LL GET
DANGER ELECTROCUTED!
● Please do not remove the ozone power supply cover or touch the printed circuit board,
otherwise there will be the risk of electric shock.
● If you need to confirm the parameter identification, please note that there is a risk of
injury during the motor rotation. Otherwise, it could cause an accident!
WARNING
● Do not change the ozone power supply manufacturer parameters. Otherwise it may cause
damage to the equipment!
VL2900 series of high-performance Ozone Power Simple Manual 3
During operation
● Non-technical personnel should not detect the signal in operation. Otherwise, it may
cause personal injury or equipment damage!
DANGER
● Do not touch the fan or the discharging resistor to check the
temperature. Failure to comply will result in personal burnt.
● During the operation of the ozone power supply, no object is allowed to fall into the
equipment. OTHERWISE CAUSE EQUIPMENT DAMAGE!
WARNING
● Do not use contactor on-off method to control the start and stop of ozone power
supply. OTHERWISE CAUSE EQUIPMENT DAMAGE!
During maintenance
● Personnel without professional training are not allowed to carry out repair and
maintenance of ozone power supply, otherwise cause personal injury or equipment
damage!
● Please do not carry on the repair and maintenance to the equipment with live
electricity. OR YOU'LL GET ELECTROCUTED!!
● carry on the ozone power supply maintenance and repair 10mins after cutting off the
ozone power supply input power. Otherwise the residual charge on the capacitor will do
DANGER
harm to people!
● Before carrying out the maintenance work on the ozone power supply, please ensure
that the ozone power supply is safely disconnected from all the power supply.
● All the pluggable components must be plugged or removed only after power-off.
● After the replacement of ozone power supply must be set and check the parameters。
● Please do not power up the damaged machine, otherwise it will enlarge the damage of
the machine.
● The rotating electric motor will feed some electric energy back to the ozone power
supply, which will cause the ozone power to be charged even when the electric motor
WARNING stops and the power is cut off. Before carrying out the maintenance work on the ozone
power supply, please ensure that the motor is safely disconnected from the ozone
power supply.
The ozone power supply has warning signs for use at the following
DANGER ● Please do not remove the cover plate when the power is on and the
● For maintenance, Inspection and wiring, please first cut off the input side
and output side power supply, and then wait 10 minutes, until the power
02、Product Information
2.1 Type and Identification
Product Category:(Take 3-phase 2.2 kw ozone power supply with built-in Brake Unit as an example.)
VL2900 T 0022 B P
Product Line
Product Nameplate(Take 3-phase 2.2 kw ozone power supply with built-in Brake Unit as an example.)
03、System Connection
● It is forbidden to connect the power supply when the power supply is turned
Danger
on. Or there's a risk of electrocution. Be Sure to keep the breaker OFF.
● During the installation, please cover the upper part of the ozone power
supply with cloth or paper to prevent metal chips, oil, water and so on from
● If the foreign matter enters the ozone power supply, may cause the ozone
● Please take off the cloth or paper when the work is finished. If continue to
Attention cover on the top, it will make the poor ventilation, resulting in abnormal heat
ozone power.
● When operating the ozone power supply, please follow the steps required by
● Do not remove the hood of the State of the ozone power supply hanging,
otherwise may cause ozone power circuit board or terminal row damage.
9 03 、 System Connection
No fuse breaker (MCCB) When the power input, a large impact current will flow into the inverter, so users
input side.
Earthing
Oxygen Generation
Form:3-1 Operating instructions for the peripheral electrical components of the Ozone Power Supply System.
Name of Mounting
Function description
accessories Position
Between the Short Circuit Breaker: cut off the power supply when the downstream
input side of equipment overflows to prevent accidents.
the power Earth Leakage Protection Circuit Breaker:High frequency leakage current
Circuit Breaker
supply and the may be produced when ozone power supply is working. In order to prevent
Ozone Power electric shock and electric fire, please select and install appropriate leakage
Supply. protection circuit breaker according to the situation on site.
Between the
breaker and Power-on and power-off operation of ozone power supply should avoid
(electromagnetic)
the input side frequent up-down operation (interval time is not less than one hour) or direct
CONTACTOR
of the Ozone start operation of ozone power supply through contactor.
Power Supply.
Increasing the power factor of the input side;
Input side of Effectively eliminate the input side of the higher harmonic, to prevent voltage
Input Reactor Ozone Power waveform distortion caused by other equipment damage;
Supply. Eliminate the unbalance of input current caused by the unbalance between
power supply phases.
Reduce the external conduction and radiation interference of Ozone Power
Input side of
EMC Supply;
Ozone Power
Filter Reduce the conduction interference from the power supply to the ozone
Supply.
power supply, improve the anti-interference ability of the ozone power supply.
Increasing the power factor of the input side;
Between the
Improve the efficiency and thermal stability of Ozone Power Supply;
direct current emc filter and
It can effectively eliminate the influence of higher harmonic on the input side
reactor the brake
of the ozone power supply and reduce the external conduction and radiation
resistance;
interference.
Between the
ozone power
supply output
Output side and the
high voltage If necessary, the output reactor can be installed or not.
Reactor package,
install close to
the ozone
power supply.
Output side of
Transformer Ozone Power Please select the suitable transformer.
Supply.
VL2900 series of high-performance Ozone Power Simple Manual 11
Form 4-3 VL2900 series product size list (single phase / three phase 200V class)
installation
Structure Power Section of External Dimension (mm) Installs Weight
dimension(mm) remarks
Code Name Ozone Power Supply A B H W L Screw (kg)
D1 0.4KW~1.5KW 125 166 186 114 172 M4 1.1
D2 2.2KW~5.5KW 160 186 248 149 237 M4 2.5 Plastic shell
hanging type
D3 7.5KW 208 194 322 190 304 M6 6.5
D4 11KW~18.5KW 280 210 436 200 425 M6 20
D5 22KW~37KW 385 265 600 260 580 M8 32
D6 45KW~55KW 473 307 700 343 678 M12 47 Metal hanging
type
D7 75KW~90KW 500 359 860 400 840 M12 90
D8 110KW~132KW 660 370 1160 400 1139.5 M12 130
Form 4-4 VL2900 series product size list (3-phase 400V class)
installation
Structure Power Section of External Dimension (mm) dimension(mm) Installs Weight remarks
Code Name Ozone Power Supply A B H W L Screw (kg)
D1 0.4KW~4KW 125 166 186 114 172 M4 1.1
D2 5.5KW~11KW 160 186 248 149 237 M4 2.5 Plastic shell
hanging type
D3 15KW~18.5KW 208 194 322 190 304 M6 6.5
D4 22KW~37KW 280 210 436 200 425 M6 20
D5 45KW~75KW 385 265 600 260 580 M8 32
D6 90KW~132KW 473 307 700 343 678 M12 47 Metal hanging type.
D7 160KW~200KW 500 359 860 400 840 M12 90
D8 220KW~315KW 660 370 1160 400 1139.5 M12 130 Please refer to the
drawing of the
D9 355KW~560KW 700 432 1340 400 1309 M12 200 machine Case.
D10 630KW~1000KW 830 510 1180 600 1240 M12 240
D11 - - - - - - - -
C1 - - - - - - - - METAL CABINET
C2 - - - - - - - - TYPE
Please refer to the
C3 - - - - - - - - drawing of the
machine Case.
VL2900 series of high-performance Ozone Power Simple Manual 13
158mm
147mm
79mm
92mm
79mm
82,6mm
SECTION A-A
8,2mm
Picture 4-2-C Outline dimensions and mounting dimensions of VL2900 external panel (TJ2)
4.2 Wiring
4.2.1 Standard wiring diagram
The following diagram is the VL2900 series 3-phase 380V voltage class 45kW ~ 1100kW model wiring diagram, other
specifications refer to the following section explanation.
Factory setting:
wire jumper J3 Operating frequency: 0~10V, F15.00=1
wire jumper J1
Relay R1 output
250Vac above 10mA and below 3A
30Vdc above 10mA and below 1A
Factory setting:
inverter fault, F17.02=4
Communication
Selection
Relay R2 output
More Than One
Single Machine
earth terminal
Form 4-5 VL2900 single-phase 220V ozone power supply wiring instructions
Terminal
Terminal Name Function description
Marking
R、T 220VPower input terminal AC input single-phase power connection point
P+、P(P1) DC reactor terminal External DC reactor (or short connection)
Ozone Power Supply Output Terminal
V、W connected load
18.5 kw or less
Ozone Power Supply Output Terminal
U、W connected load
22 KW and above
Earthing terminal(PE) protective earthing
Form 4-5 VL2900 three-phase 220V ozone power supply wiring instructions
Terminal
Terminal Name Function description
Marking
R、S、T 220VPower input terminal AC input single-phase power connection point
P+、P(P1) DC reactor terminal External DC reactor (or short connection)
Ozone Power Supply Output Terminal
V、W connected load
18.5 kw or less
Ozone Power Supply Output Terminal
U、W protective earthing
22 KW and above
Form 4-5 VL2900 three-phase 380V ozone power supply wiring instructions
Terminal
Terminal Name Function description
Marking
R、S、T 380VPower input terminal Ac input three-phase power supply connection point
P+、P(P1) DC reactor terminal External DC reactor (or short connection)
Ozone Power Supply Output Terminal
V、W connected load
37KW or less
Ozone Power Supply Output Terminal
U、W connected load
45KW and above
Earthing terminal(PE) protective earthing
Form 4-5Guide for selection of peripheral electrical components for Ozone Power Supply
SINGLE-PHASE POWER SUPPLY:220V,50Hz/60Hz
AI2 Input and output selection, the default is the current input;
wire jumper
wiring terminal
Note: Due to different specifications or product upgrades, the control loop terminal may be different from
the actual product, please refer to the actual product.
VL2900 series of high-performance Ozone Power Simple Manual 19
Form 4-6 VL2900 series Ozone Power Control Terminal function description.
Terminal Terminal
Categories Function description
Symbol Name
External Provide +10V power to the outside,Maximum output current:
+10V Connection 10mA .Generally used as an external potentiometer power
- GND + 10VPower
Supply supply,Resistance range of potentiometer: 1kΩ~10kΩ.
Power
Supply External
Provide +24V power supply to the outside, generally used as the
Connection
+24V - COM working power supply of digital input and output terminals and the
+24V Power
maximum output current of external sensor power supply: 200mA.
Supply
AI -GND Analog Input 1 Input Range: 0Vdc~10Vdc/0mA~20mA,by the control panel J 1, J13
Analog Input jumper selection decision.
AI2 -GND Analog Input 2 Input Impedance: Voltage Input 22kΩ, current input 500Ω.
X1 -COM Digital Input 1
X2 -COM Digital Input 2
X3 - COM Digital Input 3
X5 - COM Digital Input 5 Switching Input of Optical coupling isolation
X6 - COM Digital Input 6 Input impedance: 1.39 k Ω
Digital Input X7 - COM Digital Input 7
X8 - COM Digital Input 8
In addition to the characteristics of X1~X3、X5~X8 ,it can also be used
as a high-speed pulse inputchannel.
X4 - COM Digital Input 4
Maximum input Frequency: 100kHz
Input Impedance: 1.03kΩ
The voltage or current output is determined by the choice of the J2
Analog Output jumper on the control panel.
AO1 - GND
1 Output voltage range:0V~10V
Analog Output current range: 0mA~20mA
Output The voltage or current output is selected by the J3 jumper on the control
Analog Output panel.
AO2 -GND
2 Output voltage range: 0V~10V
Output current range: 0mA~20mA
Optical coupling isolation,Open collector output.
Digital Output
Y1 - +24V Output voltage range:0V~24V
1
Digital Output Output current range:0mA~50mA
DO1 - High speed
COM(Retain) High speed pulse output up to 100kHz
pulse output
TA1 - TB1 NC terminal Contact driving capacity:250Vac,3A,COSØ=0.4,
TA1 - TC1 NO terminal 30Vdc,1A
Relay Output TA2 - TB2 NC terminal Contact driving capacity:250Vac,3A,COSØ=0.4,
TA2 - TC2 NO terminal 30Vdc,1A
RS485
485+ Communicatio
Communicati n positive end
on Interface RS485 Differential signal input and output, half duplex.
selection Communicatio
485-
n negative
end
External
Auxiliary
J11 keypad External Keypad
Interface
interface
AI1 Input
J1 Voltage and current input is optional, default is voltage input
selection
AI2 Input
J13 Voltage and current input is optional, default is current input
Selection
wire jumper
AO1 Output
J2 Voltage and current output is optional, default is voltage output
Selection
AO2 Output
J3 Voltage and current output is optional, default is current output
Selection
20 04、Installation and wiring
0.022uF、50V
GND
铁氧体磁环
Ferrite magnetic core
◆ SINK wiring
Signal
External
controlle
Note 1: Be Sure to properly install the polarity of the absorption diode. Here's how. Otherwise, when the
digital output terminal has the output, will immediately burn out the DC 24V power supply.
diode
relay
05、Basic Operation
5.1 Operation Panel Instructions
Ozone power supply can be operated, monitored and controlled by LED operation panel.In addition to the LED operation
panel of ozone power supply, users can also choose the external operation panel.
Among them, the parameters can be modified and viewed through the LED operation panel, and the parameters can be
copied, downloaded and other functions through the selection of the external operation panel.
Stop; ON:operating;
Data display area
blinking slowly : Zero-frequency
operation;
blinking quickly:Dc brake; Hz A V Unit indicator
RPM %
Multi-function key
Potentiometer FU N
ESC
Exit/shortcut key
JO G
Increment key
Shift key
▲
▲
EN TER
Enter/set key
RUN key
STO P
RU N Stop/Reset key
RESET
Decrement key
Escape key
Exit / Shortcut Key Main interface to enter monitoring parameters and fault record
parameters group (F39 group) shortcut key;
Enter/set key Step into the menu screen, set parameter confirmation.
5.3 Basic operation ( Set parameters, restore factory values, command channel switch, change
monitoring parameters, password lock and unlock)
26 05 、 Basic operation and commissioning
Set parameters (the example restores the parameters to factory settings, other parameter settings are similar to this
example) :
Press ENTER
to ENTER the
Toggle significant Interface
Next Modify the
bit display
subinterface interface to
F38.0
F38
0
Interface
Modify the Press ENTER Modify the
display
interface to to ENTER the interface to
F38.08
Next 0 2
subinterface
Symbols instructions
Function Number Parameter number, that is, the number shown on the LED panel.
(Communication Represents the register address used for MODBUS communication, where H represents the
Address) hexadecimal value and the number represents the specific address.
Name Parameter Name
Represents a hexadecimal value that can only be modified (not carried) by bits and is subject to
(H) upper and lower limits.
(myriabit、housands, hundreds, tens, ones)
Parameters set range, different control mode parameters set range may be different for
Range
different models.
factory default Factory set value, different control mode different model factory set value may be different.
V: (Voltage) Volt; A: (current) Ampere; C: (temperature) Centigrade; Ω: (Resistance) ohm; mH:
(Inductance) Milligram; rpm: (speed) rpm;% : percent; BPS: (Baud Rate) Bit per second; Hz,
unit
Khz: (frequency) Hertz, Khz; ms, Sec. , Min. H: (time) ms, s, Min, H; KW: (Power) KW; 1: No
units and so on
Change properties Indicates whether the parameters can be changed and the conditions changed.
√ A parameter that can be modified in any state.
× Non-modifiable parameters in the running state.
☆ Actual detection parameters cannot be modified.
Factory parameters are only modified by the factory. USERS ARE FORBIDDEN TO MODIFY
★
THEM.
Content A description of the parameter details
RUN indicator
OFF:Stop;/ON:operating; /blinking slowly:Zero-frequency operation;/blinking quickly:Dc brake;
Command source indicator
OFF:Panel Run Command Channel;/ON:Terminal Run Command Channel;
blinking quickly:Communication run command channel;
Function
indicator blinking slowly:Analog runs command channel;
description FWD/REV( direction indicator):
ON: reverse rotation /OFF: forward rotation
TUNE/TC(Tuning/Torque control indicator): ON:
Torque control mode; /blinking slowly:Tuning status;
All the indicator lights are blinking slowly except the running indicator:Failure or alarm.
HZ: Frequency Unit; A: Current Unit; V: Voltage Unit; RMP (Hz + a) : Speed Unit;% (a + V) :
percentage.
Unit indicator
Note: The Unit Indicator Light Hz is always on when the main interface shows the output
description
frequency, and the unit indicator light Hz flashes slowly when the main interface shows the set
frequency
► :Shift key;
Press the shift key on the main interface to switch the display monitoring parameters
(F38.10 ~ F38.15 can set the monitoring parameters);
Press the shift key on the non-main interface, and the effective bits can be switched between
ones, tens, hundreds, thousands and tens thousands.
FUN/JOG:Multi-function keyMulti-function key (F37.00 can set its function) ;
ESC:Exit key / main interface entry, monitoring parameters and fault record, parameter group
Key Definition (F39 group) shortcut key;
ENTER:Enter/set key;
RUN:RUN key
STOP/RESET:STOP/RESET(F37.00 can set its functions);
▲:Increment key;
▼:Decrement key;
Long Press, increment key or decrement key in the main interface to quickly modify the relevant
parameters (F01.08 can set its modified parameters) .
28 06 、 List of parameters
2List of parameters
GroupF00 - basic functional parameters
Function
Number
Name SCOPE | [factory value] [ changes properties] and contents
(Communication
Address)
Rated power
F00.00 (0.4 ~ 999.9)[ model setting (KW)]〖★〗〖☆〗
of ozone
(0000H) Note: CAN NOT BE INITIALIZED
power supply
0~2|【0】〖√〗
Run 0:Panel Run Command Channel(Command source indicator is OFF)
F00.01 command
1:Terminal Run Command Channel(Command source indicator is ON)
(0001H) channel
selection 2:Communication run command channel(Command source indicator is
blinking quickly)
0~1|【0】〖×〗0:
F00.02
Stop Mode Deceleration Stop
(0002H)
1: Free stop
0~1|【0】〖×〗
0:invalid
1:effective
When the power is switched on after power failure, if the starting conditions
F00.03 Power cut are met, the ozone power supply will automatically run in accordance with
(0003H) restart setting the set mode after waiting for the time defined by F03.09.
Starting conditions: the starting time after power failure is set to 1 or 2.
Before power failure, it is in the running state and there is no stop
command. There is no stop command during the waiting time after power
failure.
Wait time for
F00.04
power failure 0.0~100.0|【5.0Sec.】〖√〗
(0004H)
to restart
F01-Frequency function parameters
Function
Number
Name SCOPE | [factory value] [ changes properties] and contents
(Communication
Address)
0~7|【1】〖√〗
0:frequency panel potentiometer given (only valid for panel with
potentiometer)
1:Digital frequency given1
Frequency 2:Digital frequency given2(Retention)
F01.00
source
(0100H) 3:Frequency communication given1(Absolute Value)(Retention)
selection
4:Frequency communication given2(Percentage)(Retention)
5:Frequency AI 1Analog given(0~10V/20mA)
6:Frequency AI 2Analog given(0~20mA)
7:Frequency pulse given(0~100KHZ)(Retention)
Frequency
F01.01
source digital 200~〖F01.04〗|【1000Hz】〖√〗
(0101H)
setting
panel▲/▼Ke 〖F01.02〗Pane▲/▼Keys、Encoder adjustment contro(
l H):0000~011B|
F01.02 ys 、 Encoder 【0111】〖√〗
(0102H) adjustment 〖F01.03〗TerminalUP/DOWNadjustment control(H) :0000~011B|
control(H) 【0111】〖√〗
0~1|【0】〖√〗0:
F13.06 Working
Constant voltage output
(0D06H) mode
1:Constant current output
0~3|【1】〖√〗
0:Panel potentiometer given(100% corresponding to the rated current of
Ozone Power Supply)
F13.07 Current given
1:Current digital given(100% corresponding to the rated current of Ozone
(0D07H) channel
Power Supply)
2:AI1(100% corresponding to the rated current of Ozone Power Supply)
3:AI2(100% corresponding to the rated current of Ozone Power Supply)
F13.08 Digital current
0.0~100.0%|【0.0%】〖√〗
(0D08H) setting
Current 0.0~30.0%|【5.0%】〖√〗
F13.09
adjustment The current adjustment deviation is the percentage of the given value of the
(0D09H) deviation relative current
Current 0~1|【0】〖√〗
F13.10
detection 0:invalid 1:
(0D0AH)
selection effective
F13.11 Current
0.0~100.0%|【90.0%】〖√〗
(0D0BH) detection level
Current
F13.12
detection 0.0~60.0|【5.0Sec.】〖√〗
(0D0CH)
delay time
0~1|【0】〖√〗
F13.13 Retention
0:invalid
(0D0DH) parameter
1:effective
F14 - analog and pulse input parameters
Function
Number
Name SCOPE | [factory value] [ changes properties] and contents
(Communication
Address)
AI1 minimum 0.00~10.00|【0.10V】〖√〗
F14.00
input voltage Set The minimum input voltage of Terminal AI1. When current signal is
(0E00H)
(current) selected, 0.00 v means 0.00 mA, 10.00 v means 20.00mA.
AI1 minimum 0.0~100.0|【0.0%】〖√〗
F14.01 input The percentage of the actual physical quantities corresponding to the
(0E01H) corresponding minimum input voltage of Terminal AI1.Above the corresponding set out of
setting its scope to take its critical value.
AI1 maximum 0.00~10.00|【10.00V】〖√〗
F14.02
input voltage Set the maximum input voltage of terminal AI1. When the current signal is
(0E02H)
(current) selected, 0.00V represents 0.00mA, and 10.00V represents 20.00mA.
AI1 maximum 0.0~100.0|【100.0%】〖√〗
F14.03 input The percentage of the actual physical quantities corresponding to the
(0E03H) corresponding maximum input voltage of Terminal AI1. Above the corresponding set out of
setting its scope to take its critical value.
F14.04 AI1 input
0.00~10.00|【0.10Sec.】〖√〗
(0E04H) filtering time
AI2 minimum 0.00~10.00|【0.10V】〖√〗
F14.05
input voltage Set the minimum input voltage of terminal AI2. When the current signal is
(0E05H)
(current) selected, 0.00V represents 0.00mA, and 10.00V represents 20.00mA.
AI2 minimum 0.0~100.0|【0.0%】〖√〗
F14.06 input Set the percentage of the actual physical quantity when terminal AI2 inputs
(0E06H) corresponding the minimum input voltage.When the above corresponding setting exceeds
setting its range, its critical value is taken.
AI2 maximum 0.00~10.00|【10.00V】〖√〗
F14.07
input voltage Set the maximum input voltage of terminal AI2. When the current signal is
(0E07H)
(current) selected, 0.00V represents 0.00mA, and 10.00V represents 20.00mA.
AI2 maximum 0.0~100.0|【100.0%】〖√〗
F14.08 input Set the percentage of the actual physical quantity when terminal AI2 inputs
(0E08H) corresponding the maximum input voltage.When the above corresponding setting
setting exceeds its range, its critical value is taken.
VL2900 series of high-performance Ozone Power Simple Manual 31
0000~1111|【0000】〖√〗
LED unit's digit:X1 Logical Setting
LED ten's digit:X2 Logical Setting
Input terminal LED Hundred's digit:X3 Logical Setting
F16.08 Effective status
(1008H) LED Thousand's digit:X4 Logical Setting
setting 1(H) 0: represents the positive logic, that is, the corresponding terminal and the public
connection is valid, disconnect is invalid
1: Represents the anti-logic, that is, the corresponding terminal and the public
connection invalid, disconnect valid
0000~1111|【0000】〖√〗
LED unit's digit:X5 Logical Setting
LED ten's digit:X6 Logical Setting
Input terminal LED Hundred's digit:X7 Logical Setting
F16.09 Effective status
(1009H) LED Thousand's digit:X8 Logical Setting
setting2(H) 0: represents the positive logic, that is, the corresponding terminal and the public
connection is valid, disconnect is invalid
1: Represents the anti-logic, that is, the corresponding terminal and the public
connection invalid, disconnect valid
F16.10 Input terminal
0~200|【20ms】〖√〗
(100AH) filtering time
0~3|【0】〖√〗
Terminal control 0:Two-wire control mode1
F16.11 mode 1:Two-wire control mode2
(100BH)
(FWD、REV、SIn) 2:Three-wire control mode1
3:Three-wire control mode2
0~1|【0】〖√〗
0:The terminal running command is invalid when power on(the terminal is first
Power on disconnected and then closed)
F16.12 terminal running 1:The terminal running command is valid when the power is on.
(100CH) protection The given signal of the two-wire mode operation instruction is the level signal.
selection When the terminal is in the effective state, the ozone power supply will start
automatically.In a system that does not want to be powered up by itself, the
terminal operation command can be selected to be invalid when powered up.
UP/DOWN
F16.13 Terminal
10~1000|【100Hz/S】〖√〗
(100DH) frequency
modification rate
0.1~10.0|【1.0Sec.】〖√〗
F24.02 Fault automatic
(1802H) reset interval time The shortest interval from the current fault self-reset to the next fault
self-reset.
F25 group - advanced functional parameters (retained)
Group F26 - communication function parameters
Function Number
SCOPE | [factory value] [ changes properties] and
(Communication Name
contents
Address)
0000~1551|【0030】〖×〗
LED units' digit:Protocol selection
0:MODBUS
1:Customizing(Retention)
LED Ten' digit :Communication baud rate setting 0:
1200BPS
1:2400BPS
2:4800BPS
3:9600BPS
4:19200BPS
5:38400BPS
Communication 6:79600BPS(Retention)
F26.00
(1A00H) configuration(H) 7:115200BPS(Retention)
LED Hundred's digit:The data format
0:1-bit initiation bit、8-bit data bits、1 bit stop bit、No check for RTU
1:1-bit initiation bit、8-bit data bits、1 bit stop bit、Parity check for RTU
2:1-bit initiation bit、8-bit data bits、1 bit stop bit、Odd parity check for
RTU
3:1-bit initiation bit、8-bit data bits、2 bit stop bit、No check for RTU
4:1-bit initiation bit、8-bit data bits、2 bit stop bit、Parity check for RTU
5:1-bit initiation bit、8-bit data bits、2 bit stop bit、Odd parity check for
RTU
LED Thousand's digit:
0:The write operation has a response
1:Write operation no response
0~247|【1】〖×〗
0:master station 1~
247:Slave station
This parameter is used for serial port communication, set the address of
F26.01 Local machine this ozone power supply.0 is the broadcast address. When set to the
(1A01H) address broadcast address, only the broadcast command can be sent without
answering the host computer.1 ~ 247 slave address, set as slave
address, in the communication process, the machine only with the native
address (or broadcast address) consistent data frame to receive
instructions, and reply frame (broadcast address instruction does not
respond).
0~1000|【5ms】〖×〗
When the ozone power supply is the main engine, this is the
F26.02 Local reply (send) transmission delay time, the minimum delay time is 30ms, if the set
(1A02H) delay value is less than 30ms, it is 30ms.When the ozone power supply is the
slave machine, this is the response delay time, and the actual response
delay time is not less than the transmission time of 3.5 characters.
0000~0022|【0010】〖×〗
LED units' digit:Communication abnormal detection selection
0:No abnormal communication detected
1:Any state is checked 2:
Communication Run status detection only
F26.03 LED Ten' digit:Communication abnormal action selection
abnormal action
(1A03H)
selection 0:Communication failures(E-30)Free shutdown 1:
Alarm (A-30) and maintain the status quo
2:Alarm (a-30) and stop the machine according to the set stop mode
LED Hundred's digit:Retention
LED Thousand's digit:Retention
Communication 0.1~100.0Sec.|【10.0】〖√〗
F26.04
anomaly After the time delay is determined, the normal communication is still
(1A04H)
determination time
unable and the abnormal communication is handled.
Group F27 ~ Group F36-reserved parameter of Special Function
VL2900 series of high-performance Ozone Power Simple Manual 37
0x0000~0x0144|【0x0140】〖×〗
LED units' digit :M-FUNC Key function selection
0:JOG(Positive inching turningt) 1:
JOG(reverse inching turning)
2:Reverse operation
3:Forward and Reverse Switching
4:Clear Panel▲/▼key Set frequency
LEDTen' digit:STOP/RSTKey function selection
F37.00 Panel function key
(2500H) setting (H) 0: only valid for keyboard control
1: effective for both keyboard and terminal control
2: effective for both keyboard and communication control
3: effective for both keyboard and analog command control(Retention)
4: works for all control modes
LED Hundred's digit :STOP+RUNKey function selection 0:
invalid
1:Free Parking
LED Thousand's digit:Retention
Panel▲/▼、
F37.01
Encoder 10~1000|【100】〖√〗
(2501H)
Adjustment Rate
0~2|【1】〖√〗
Panel
F37.02 0: protect action and stop freely
communication
(2502H) 1. Alarm and maintain the status quo
abnormal action
2. Alarm and stop according to the set stop mode
Panel
F37.03 communication 0.0~100.0|【1.0Sec.】〖√〗
(2503H) timeout checkout Note: do not do panel timeout detection when set to 0.0
time
Group F38-system management parameters
Function Number
(Communication Name SCOPE | [factory value] [ changes properties] and contents
Address)
0~65535|【0】〖√〗0:
No Password Protection
1~65535:Password protected,Group F00 ~ F39 parameters need to
verify the password to view and modify
Password setting: ENTER this parameter without password, the
interface displays "00000", set the password value (non-zero) and press
"ENTER", the interface prompts "AgAIn", set the password value AgAIn
and press "ENTER" to ENTER.If the setting values are the same, the
interface prompts "End", then the password is set successfully, and the
F38.00
User Password password protection will take effect immediately;If the Settings entered
(2600H)
twice are different, the interface prompts "Error", then the password
setting fails and needs to be reset.
Password unlock: enter this parameter with password status, the
interface displays "----", enter the password value set last time.If the
password matches, the interface jumps to the next parameter, and the
password is unlocked successfully;If the password does not match, the
interface will prompt "Error", and the password unlock fails, and shall be
unlocked again.
Note: CAN NOT BE INITIALIZED
0~65535|【0】〖√〗0:
No Password Protection
1 ~ 65535: F0.00 REQUIRES PASSWORD VERIFICATION TO BE
F38.01 MODIFIED.
Agent password
(2601H) Password settings and password unlock operation the same user
password (F38.00) , but the password unlock 10 minutes will be
automatically locked.
Note: CAN NOT BE INITIALIZED
38 06 、 List of parameters
0 ~ 65535| 【 0 】 〖 √ 〗 0 :
No Password Protection
F38.02 Run limit function 1 ~ 65535: F38.03, F38.04 need to verify password to view and modify.
(2602H) password Password settings and password unlock operations with the same user
Password (F38.00)
Note: CAN NOT BE INITIALIZED
0~1|【0】〖√〗
0: ban
1: restricted operation
F38.03 Run limit function The operation time is calculated from the effective start of the limited
(2603H) selection operation. When the measured operation time is greater than the set
operation limit time, the ozone power supply enters the operation limit
time and reaches the protection, indicating e-21, which can be contacted
with the direct supplier.
Note: CAN NOT BE INITIALIZED
0.0~6000.0|【10.0h】〖√〗
The operation time is calculated from the effective start of the limited
F38.04 Operating limit operation. When the measured operation time is greater than the set
(2604H) time operation limit time, the ozone power supply enters the operation limit
time and reaches the protection, indicating e-21, which can be contacted
with the direct supplier.
Note: CAN NOT BE INITIALIZED
0~2|【0】〖√〗
LCD keyboard 0: Chinese
F38.05
Display language 1: English
(2605H)
selection 2: keep
Note: CAN NOT BE INITIALIZED
0~3|【1】〖√〗
LEDunits' digit:Parameter display mode selection (reserved)
LEDTen' digi:Main interface monitoring parameter cycle display
parameter selection0~1|【0】〖√〗
F38.06
Display mode 0: Do Not Cycle (the main interface only shows a monitoring parameters,
(2606H)
selection (H) need to show other parameters can be switched through the shift key)
1: AUTOMATIC LOOP (F38.10 ~ F38.12 or F38.13 ~ F38.15 set by the
monitoring parameters loop display, each parameter display 5 seconds
to switch to the next display parameters)
0~2|【0】〖√〗
0: All parameters are allowed to be modified (some parameters can not
F38.07 be modified at run time)
Write protection 1: only allow to change the frequency setting F01.06, F01.07
(2607H)
2: All parameters ARE FORBIDDEN TO BE MODIFIED
The above restrictions are not valid for this function code and User
Password
0~4|【0】〖×〗
0: No Operation
1: User Parameter Initialization 1
F38.08 Parameter
2: User Parameter Initialization 2
(2608H) initialization
3: User Parameter Initialization 3(reserved)
4: clear the fault record (the contents of the fault record are reset to
F39.76 ~ F39.99)
VL2900 series of high-performance Ozone Power Simple Manual 3 9
0~3|【0】〖×〗
0: no operation
1: parameters are uploaded to the panel
2: all function code parameters are downloaded to the ozone power
supply
3: all function code parameters except the motor (reserved) parameters
are downloaded to the ozone power supply
When set to 1 and confirmed, the ozone power will upload all the
function code set values between F00.00 and F38.15 in the control
panel to the memory of the operation panel for storage.
After setting it to 2 and confirming, ozone power will download all the
function code set values between F00.00 and F38.15 in the operation
panel to the internal control board for storage.
After setting it to 3 and confirming, ozone power will download all the
function code set values between F00.00 and F38.15 in the operation
F38.09 Parameter copy panel to the internal control board for storage.(motor parameters of F04
(2609H) function group and F05 group are not downloadable)
Note:
1) for the operation panel, the parameters must be uploaded first,
otherwise the memory of the operation panel is empty;After a parameter
upload operation, the function code parameters will always be saved in
the memory of the operation panel.
2) before the operation of the download as a parameter to ozone power
supply, power of ozone will check the integrity of the function code within
the operation panel parameters and version information, if the memory is
empty, or parameter is not complete, or parameter version does not
accord with the current ozone power supply software version (different)
function code number, all can not download the parameters, and prompt
copy error information;
3) after parameter download, the parameters in the memory of the
operation panel still exist, so repeated copies of multiple ozonepower
sources can be performed.
0~99|【9】〖√〗
This parameter defines one of the monitoring parameters that can be
displayed on the main interface under the running state of ozone power
supply. For example, the default setting is 4, which means that
Operation status
F38.10 monitoring parameters and fault record group (F39 group) no. 4
monitoring
(260AH) parameter F39.04 "output frequency" can be displayed. The next
parameter 1
monitoring parameter can be displayed through the shift key on the main
interface.
Detailed functional options can be found in <F39 Group - Monitoring
Parameters and Fault Records>
0~99|【4】〖√〗
This parameter defines one of the monitoring parameters that can be
displayed on the main interface under the running state of ozone power
Operation status supply. For example, the default setting is 9, which means that
F38.11
monitoring monitoring parameters and fault record group (F39 group) no.9
(260BH)
parameter 2 parameter F39.9 "output voltage" can be displayed. The next monitoring
parameter can be displayed under the main interface by the shift key.
Detailed functional options can be found in <F39 Group - Monitoring
Parameters and Fault Records>
0~99|【10】〖√〗
This parameter defines one of the monitoring parameters that can be
displayed on the main interface under the running state of ozone power
supply. For example, the default setting is 10, which means that the
Operation status
F38.12 monitoring parameters and fault record group (F39 group) no.10
monitoring
(260CH) parameter F39.10 "output current" can be displayed. The next
parameter 3
monitoring parameter can be displayed under the main interface through
the shift key.
Detailed functional options can be found in <F39 Group - Monitoring
Parameters and Fault Records>
0~99|【37】〖√〗
This parameter defines one of the monitoring parameters that can be
displayed on the main interface under the shutdown state of ozone
power supply. For example, the default setting is 3, which means that
Downtime
F38.13 monitoring parameters and fault record group (F39 group) no. 3
monitoring
(260DH) parameter F39.03 "target frequency" can be displayed. The next
parameter 1
monitoring parameter can be displayed under the main interface through
the shift key.
Detailed functional options can be found in <F39 Group - Monitoring
Parameters and Fault Records>
40 06 、 List of parameters
0~99|【2】〖√〗
This parameter defines one of the monitoring parameters that can be
displayed on the main interface under the shutdown state of ozone
Downtime power supply. For example, the default setting is 16, which means the
F38.14
monitoring monitoring parameters and fault record group (F39 group) no.16
(260EH)
parameter 2 parameter F39.16 "input voltage" can be displayed. The next monitoring
parameter can be displayed under the main interface by the shift key.
Detailed functional options can be found in <F39 Group - Monitoring
Parameters and Fault Records>
0~99|【17】〖√〗
This parameter defines one of the monitoring parameters that can be
displayed on the main interface under the shutdown state of ozone
Downtime power supply. For example, the default setting is 17, which means that
F38.15
monitoring monitoring parameters and fault record group (F39 group) no.17
(260FH)
paramete 3 parameter F39.17 is "bus voltage". The next monitoring parameter can
be displayed under the main interface through the shift key.
Detailed functional options can be found in <F39 Group - Monitoring
Parameters and Fault Records>
F38.16 Panel software 1.00~99.99|【1.00】〖☆〗
(2610H) version number Note: CAN NOT BE INITIALIZED
F38.17 Control software 1.00~99.99|【1.00】〖☆〗
(2611H) version number Note: CAN NOT BE INITIALIZED
0.0~800.0|【0.0V】〖★〗〖×〗
This parameter is used for bus voltage correction. When the ozone
power supply is stopped, directly input the correct bus voltage value, that
is, the bus voltage correction is completed. After the correction is
F38.18 Bus voltage completed, this parameter will automatically reset to zero.
(2612H) correction Note: in the case of bus voltage correction, the correction will be
abandoned if the difference between the input correction bus voltage
value and the detected voltage value is greater than 50%. At this time,
there may be a hardware fault. Please correct after removing the
hardware fault.
Note: CAN NOT BE INITIALIZED
Group F39-monitoring parameters and failure records
Function Number
(Communication Name SCOPE | [factory value] [ changes properties] and contents
Address)
F39.00
Set frequencyA 0~8000|【0Hz】〖☆〗
(2700H)
Set
F39.01
frequencyB(Retent 0~8000|【0Hz】〖☆〗
(2701H)
ion)
Set frequency
F39.02
(combined 0~8000|【0Hz】〖☆〗
(2702H) frequency)
target frequency 0~8000|【0Hz】〖☆〗
F39.03
( frequency Monitor the final frequency set by the user and the target frequency of
(2703H)
order) operation of the ozone power supply.
The output
0~8000|【0Hz】〖☆〗
F39.04 frequency
(2704H) Monitor the output frequency of the Ozone Power Supply (excluding slip
(before slip
compensation) compensation).
output frequency
0~8000|【0Hz】〖☆〗
F39.05 (Retention)
(2705H) (after slip Monitor the output frequency of the Ozone Power Supply (including slip
compensation) compensation) .
Estimated 0~8000|【0Hz】〖☆〗
F39.06
frequency of The operating frequency of the motor as estimated by the monitoring
(2706H) Motor(Retention) program.
Measured 0~8000|【0Hz】〖☆〗
F39.07
frequency of Monitor the actual motor operating frequency measured by photoelectric
(2707H)
motor(Retention) encoder.
F39.08 Motor 0~60000|【0rpm】〖☆〗
(2708H) speed(Retention) Monitor the running speed of motor.
F39.09 0.0~1140.0|【0.0V】〖☆〗
output voltage
(2709H) Monitor the output voltage of ozone power supply.
F39.10 0.0~6000.0|【0.0A】〖☆〗
output current
(270AH) Monitor the output current of ozone power supply.
VL2900 series of high-performance Ozone Power Simple Manual 41
0.0~6000.0|【0.0A】〖☆〗
F39.86 Output current in
(2756H) the second fault Record the ozone power supply output current at the time of the
previous failure.
Bus voltage in 0.0~2500.0|【0.0V】〖☆〗
F39.87
case of second Record the DC bus voltage of the ozone power supply at the time of the
(2757H) failure previous failure.
0.0~125.0|【0.0℃】〖☆〗
F39.88 The temperature of
(2758H) the second failure Record the maximum temperature (module temperature or radiator
temperature) at the time of the previous failure.
From the Second
Malfunction 0000~FFFF|【0000】〖☆〗
F39.89 Ozone power To record the time of the last failure Ozone power supply operation
(2759H) supply operation status。
status1(H)
Terminal input 0000~00FF|【0000】〖☆〗
F39.90
status in case of Record the input status of the ozone power supply terminal at the time of
(275AH) second failure(H) the previous failure.
Terminal output 0000~000F|【0000】〖☆〗
F39.91 status in case of
(275BH) Record the output status of the ozone power supply terminal at the time
Second Failure(H) of the previous failure.
F39.92 Type of third 0~99|【0】〖☆〗
(275CH) failure Record the type of fault for the current fault.
The operating 0~8000|【0Hz】〖☆〗
F39.93
frequency of the Record the operating frequency of the ozone power supply at the current
(275DH) third failure time of failure.
0.0~6000.0|【0.0A】〖☆〗
F39.94 Output current in
(275EH) the Third Fault Record the output current of the ozone power supply at the current time
of failure.
0.0~2500.0|【0.0V】〖☆〗
F39.95 Bus Voltage at the
(275FH) third fault Record the DC bus voltage of the ozone power supply at the current
time of failure.
0.0~125.0|【0.0℃】〖☆〗
F39.96 The temperature of
(2760H) the third failure Record the maximum temperature (module temperature or radiator
temperature) at the time of the current failure.
The third time it
malfunctioned: 0000~FFFF|【0000】〖☆〗
F39.97 Ozone power To record the time of the current failureOzone power supply operation
(2761H) supply operation status。
status1(H)
Terminal input 0000~00FF|【0000】〖☆〗
F39.98 status in case of
(2762H) Record the input status of the ozone power supply terminal at the current
third failure(H) time of failure.
Terminal output 0000~000F|【0000】〖☆〗
F39.99 status at the third
(2763H) Record the output status of the ozone power supply terminal at the
failure(H) current time of failure.
VL2900 series of high-performance Ozone Power Simple Manual 44
Attention :
(1) the cause of the failure must be thoroughly checked and removed before resetting, otherwise the ozone power supply
may be permanently damaged.
(2) if the device can not be reset or fails again after the reset, the reason should be checked. Continuous reset will
damage the ozone power supply.
(3) the protection action of overload and overheat should be reset 5 minutes later.
Fault Fault
Possible Cause Solutions
Code description
1. CPU damage
E-18 CPU fault 1. Seek manufacturer's Service
2. Abnormal interference
1. In the process of reading and writing
Internal data functional code data, there is strong 1. Retry after reset
E-19
storage error interference around. 2. Seek the services of manufacturers
2. Internal memory damage
1. In the process of reading and writing
Parameter functional code data, there is strong 1. Retry after reset
E-20
copy error interference around. 2. Seek the services of manufacturers
2. Internal memory damage
Run limit time 1. The time limit for operation has
E-21 Please contact your direct supplier
reached expired.
1. The lead from the power grid to the
Phase is
ozone power supply is broken 1. Eliminate peripheral failures
E-22 missing on the
2. The three-phase voltage imbalance 2. Add AC or DC reactor
input side
ratio is large
Phase missing 1. The lead from ozone power supply to
on the output load is broken. 1. Eliminate peripheral failures
E-23 side Or the 2. Ozone power driver board or control 2. Seek support from manufacturers
output current board failure. 3. Troubleshoot load failures
is unbalanced 3. Load three-phase Winding Fault.
1. Ozone power output short circuit to the
Output to
ground 1. Troubleshoot peripheral faults
E-24 Ground Short
2. Load three-phase winding short-circuit 2. Troubleshoot load failures
Circuit Fault to the ground
External 1. The ozone power peripheral equipment
1. Check signal source and related
E-25 Equipment 1 1 fault input terminal has the SIGNAL
equipment
Failure INPUT.
External
1. Ozone power peripheral equipment 2 1. Check signal source and related
E-26 Equipment 2
fault input terminal has signal input. equipment
Failure
External 1. Ozone Power Peripheral Equipment 3
1. Check signal source and related
E-27 Equipment 3 FAULT INPUT TERMINAL HAS SIGNAL
Failure INPUT equipment
External 1. Ozone Power Peripheral Equipment 4
1. Check signal source and related
E-28 Equipment 4 FAULT INPUT TERMINAL HAS SIGNAL
equipment
Failure INPUT
Keyboard
1. Loose wiring from keyboard to ozone 1. Check the wiring from keyboard to
E-29 communicatio
power supply ozone power supply
n failure
1. RS485 communication signal break
RS485Commu 1. Check analog input signal wiring,
2. Unreasonable configuration of
E-30 nication analog input signal source
parameters related to wire breakage
failures detection 2. Modify configuration parameters
1. Voltage rise time set too short
1. Adjust voltage rise time
2. Start immediately after output is
2. Need to troubleshoot before starting
stopped due to a Fault
3. Choose the ozone power supply with
The current 3. The power capacity of ozone is on the
matching capacity grade
E-44 was detected low side
4. Eliminate the source of short circuit or
to be faulty 4. The load end has short circuit or the
ignition failure
electrode ignites
5. Modification of current detection
5. The setting of current detection
parameters is not reasonable parameters
Voltage
E-99 —— ——
correction fault
VL2900 series of high-performance Ozone Power Simple Manual 4 7
The above ozone power supply parts replacement time of the use of the conditions:
(1) ambient temperature: 30 °C annual average.
(2) load factor: less than 80% .
(3) running time: less than 12 hours per day.