The two-day training agenda covers an introduction to META's ring main units (RMUs) and their components and operation. Day 1 includes a factory tour, presentations on RMU components and uses, and types of RMUs. Day 2 consists of hands-on practice operating and testing RMUs, learning about remote terminal units, and installation, troubleshooting and maintenance of RMUs. Key topics are the purpose and components of RMUs like load break switches and circuit breakers, their interlocking functions, and factory acceptance tests for RMUs. The training aims to educate participants on technical aspects of RMUs for medium voltage power distribution networks.

Uploaded by

Tanveer Ahmad
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
55 views46 pages

Training

The two-day training agenda covers an introduction to META's ring main units (RMUs) and their components and operation. Day 1 includes a factory tour, presentations on RMU components and uses, and types of RMUs. Day 2 consists of hands-on practice operating and testing RMUs, learning about remote terminal units, and installation, troubleshooting and maintenance of RMUs. Key topics are the purpose and components of RMUs like load break switches and circuit breakers, their interlocking functions, and factory acceptance tests for RMUs. The training aims to educate participants on technical aspects of RMUs for medium voltage power distribution networks.

Uploaded by

Tanveer Ahmad
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 46

RMU Training

at META Factory
09-oct-22 to 10-oct-22
Agenda-Day 1
Day-1 (9th Oct 2022)

Time Slot Activity


09:00 – 09:30 WELCOMING AND META PROFILE
09:30 – 11:00 SHOP FLOOR VISIT
11:00 – 11:15 COFFEE BREAK
11:15 - 12:00 INERODUCTION FOR RMU
12:00 - 1:00 LUNCH BREAK
1:00 - 3:00 RMU COMPONENT , OPERATION , INTERLOCK ,PURPOSE OF USE , TYPE OF RMU
Agenda- Day 2
Day-2 (10th Oct 2022)

Time Slot Activity


09:00 – 11:00 PRACTICAL FUNCTION OPERATION AND TESTING
11:00 – 11:15 COFFEE BREAK
11:15 - 12:00 RTU AND BRIEF IDEA ABOUT AUTOMATION
12:00 - 1:00 LUNCH BREAK
1:00 - 3:00 INSTALLATION/TROUBLESHOOTING/MAINTENANCE
META PROFILE
META PROFILE
META PROFILE
Medium Voltage Automated Ring Main Unit
META PROFILE

Shop floor Visit


Technical Overview RMU

What is RMU
Switching and protection devices. In an electrical power distribution system, a ring main
unit (RMU) is a factory assembled, metal enclosed set of switchgear used at the load
connection points of a ring-type distribution network.
Technical Overview RMU
RMU Application
RMU is Ring Main Unit , it is responsible to feed and distribute medium voltage in power
system network
Technical Overview RMU
RMU Application
Main advantages of RMU is that , ability to switch “ON/OFF” for both outgoing and
incoming.
So for example if there is a fault in Transformer or maintenance works , we can switch OFF
outgoing breaker to Transformer and confirm isolation by switch “ON“ Earth switch , and
keep another two “LBS” Load Break Switch in “ON” position , voltage supply will proceed to
another customer.
In another scenario , if there is a fault or maintenance works in power cable connected with
RMU , we can switch “OFF “LBS which connected with that power cable , and confirm
isolation by switch “ON“ Earth switching .in same time we can proceed with Transformer
feeding by other incoming source in RMU
Technical Overview RMU
RMU Component
Technical Overview RMU
RMU Component
Technical Overview RMU
RMU Component
Technical Overview RMU
RMU Component
LBS Load Break Switch
Responsible to switch “ON/OFF” voltage supply and load for power cables connected
with RMU , for transfer supply or for maintenance works.
T-Off Breaker
Responsible to arrange protection for transformer, also give transformer isolation facility
for maintenance works
Earth Switch
Responsible to confirm discharge of power cable after switch it “OFF” , then
maintenance works for it can start .
CT and VT sensors
EFI Earth Fault indicator
Protective Relay
RTU Remote Terminal Unit
Technical Overview RMU
Technical Overview RMU
Feature in META RMU
Technical Overview RMU
SMART RMU & CONVENTIONAL RMU

In Smart RMU ,there is extra components like RTU Remote


Terminal Unit , CT sensors and VT sensors ,
all LBS and Breaker status will be seen form control center by
RTU , also CT and VT sensors will send current and voltage
reading to RTU which will transfer these reading to distribution
control center (SCADA-ADMS) ,
Technical Overview RMU
Technical Overview RMU
Technical Overview RMU
Technical Overview RMU
Technical Overview RMU
Technical Overview RMU
Technical Overview RMU
Technical Overview RMU
Technical Overview RMU
Technical Overview RMU
Technical Overview RMU
Technical Overview RMU
Technical Overview RMU
OPERATION INTERLOCK
Technical Overview RMU
Technical Overview RMU
Technical Overview RMU
Technical Overview RMU
Technical Overview RMU
Technical Overview RMU
Technical Overview RMU
FACTORY ACCEPTANCE TEST (FAT)

1. Design and Visual Checks


2. Mechanical Operating and interlock Tests
3. Insulation Resistance Test
4. Dielectric Test on the Main Circuit
5. Functional Tests
6. Measurement of the Resistance of the Main Circuit
7. Test of Protection Circuits
8. Fault Indicator function test (FI)
Technical Overview RMU
FACTORY ACCEPTANCE TEST (FAT)
Technical Overview RMU
FACTORY ACCEPTANCE TEST (FAT)
Technical Overview RMU
FACTORY ACCEPTANCE TEST (FAT)
Technical Overview RMU
FACTORY ACCEPTANCE TEST (FAT)
Technical Overview RMU
FACTORY ACCEPTANCE TEST (FAT)
Technical Overview RMU
FACTORY ACCEPTANCE TEST (FAT)
Technical Overview RMU
FACTORY ACCEPTANCE TEST (FAT)
Thank you

You might also like