0% found this document useful (0 votes)
195 views4 pages

FS 3200 - FS-Flow Switch

The document provides specifications for a flow switch, including: 1) An overview of the document scope and contents. 2) Requirements for codes, standards, scope of supply, and general switch specifications. 3) Details on switch material requirements and a sample data sheet format.

Uploaded by

Binu Mani
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
195 views4 pages

FS 3200 - FS-Flow Switch

The document provides specifications for a flow switch, including: 1) An overview of the document scope and contents. 2) Requirements for codes, standards, scope of supply, and general switch specifications. 3) Details on switch material requirements and a sample data sheet format.

Uploaded by

Binu Mani
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

Design Division Spec # 3200

Engineering Services Functional Specifications Rev # 2


11 - High, Mumbai FLOW SWITCH Discipline Instt.
ISO 9001: 2000 Page # 1 of 4

FUNCTIONAL SPECIFICATION

FOR

FLOW SWITCH

TOTAL
PREPARED / REVIEWED REV.
APPROVED BY No. OF DATE
REVISED BY BY No.
PAGES
VS RS GRP 4 18.02.2008 2
ET RS GRP 6 28.03.2007 1
ET MC AC 6 13.05.2003 0

ISO -FORMAT No. Ref. PROCEDURE No. ISSUE No. REV. No. REV. DATE:
DD/SOF/004A/B DD/SOP/008 TO 015 02 01 01/08/2006
Design Division Spec # 3200
Engineering Services Functional Specifications Rev # 2
11 - High, Mumbai FLOW SWITCH Discipline Instt.
ISO 9001: 2000 Page # 2 of 4

CONTENTS

Clause No. ITEM Page No.


1.0 Scope of This Document 3
2.0 Codes and Standards 3
2.1 Reference specifications 3
3.0 Scope of Supply 3
4.0 Flow Switch 3
4.1 General 3
4.2 Material 3
Annexure I Data Sheet Format 4

ISO -FORMAT No. Ref. PROCEDURE No. ISSUE No. REV. No. REV. DATE:
DD/SOF/004A/B DD/SOP/008 TO 015 02 01 01/08/2006
Design Division Spec # 3200
Engineering Services Functional Specifications Rev # 2
11 - High, Mumbai FLOW SWITCH Discipline Instt.
ISO 9001: 2000 Page # 3 of 4

1.0 SCOPE OF THIS DOCUMENT:


1.1 This functional specification describes the essential design considerations for the
selection of Flow Switch for the intended service.
2.0 CODES & STANDARDS:
2.1 Reference Documents and Specifications:
a) Instrumentation Design Criteria
b) Basic Bid Work
c) Project P & IDs
d) Process Design Criteria / Instrument Process Data Sheets / Instrument List with
Process Parameters
3.0 SCOPE OF SUPPLY:
3.1 The quantity to be supplied and installed shall be as per the requirements indicated
in the Basic Bid Work, Design Criteria and the P & IDs.
3.2 The vendor shall be responsible for the selection of the Flow Switch suitable for its
intended application, its procurement, tagging, packing, testing & calibration,
preparation for shipment, along with accessories, spares, and assistance where
required for its installation & commissioning at site. This FS shall be read in
conjunction with the Instrument Design Criteria.
4.0 FLOW SWITCH:
4.1 General:
4.1.1 The flow switch shall be Differential Pressure type / Thermal Dispersion type
suitable for Class I, Division I, Group D, T3 class.
4.1.2 The flow switch shall actuate a relay when activated or when shutdown is reached.
The contact rating shall in general be 24 V DC, 2 A. Flow Switches shall have a
repeatability of ±0.2%.
4.1.3 The flow switch shall have either internal / external set point adjustment with
locking mechanism to avoid tampering.
4.1.4 Cable entry to the flow switch shall be ¾” NPTF. Two numbers of cable entry
shall be provided. One cable entry shall be plugged with a plug suitable for the
area classification.
4.1.5 In case Insertion type flow switches are used, the immersion length for probe shall
be 250 mm from flange top face. The projection of flange nozzle from pipe top
face shall be 200 mm.
4.1.6 Plastic bags shall be provided for Flow Switches to protect them during handling,
installation and commissioning.
4.1.7 All switches shall be Ex d.
4.2 Material:
4.2.1 The material requirements for Flow Switches shall in general be according to
clause 3.6.4.5 of Instrumentation Design Criteria.
4.2.2 The flow switch sensor material shall be suitable for the process conditions and
shall be minimum SS 316. For water service, the sensor material shall be Monel.

ISO -FORMAT No. Ref. PROCEDURE No. ISSUE No. REV. No. REV. DATE:
DD/SOF/004A/B DD/SOP/008 TO 015 02 01 01/08/2006
Design Division Spec # 3200
Engineering Services Functional Specifications Rev # 2
11 - High, Mumbai FLOW SWITCH Discipline Instt.
ISO 9001: 2000 Page # 4 of 4

ANNEXURE – I
Typical Data Sheet For Flow Switches
FLOW SWTICHES
3 3
UNITS: Flow Liquid – M /HR. Gas – NM /HR. Pressure – Kg/cm2 Temperature – oC Level/Length - M
1 Tag Number
2 Line Number
GENERAL 3 Line Size & Schedule
4 Service
5
6 Switch Type
7
8 End Connection – Size & Rating
9 End Connection – Facing & Finish
10 Material – Body & Flange
11 Material – Element
BODY
12 Range
13
14
15
16
17
18 Type – Electric / Pneumatic
19 Output Type
20 Contact Rating
21 Load Type
22 Enclosure Class
23 Area Class
24 On flow increase – O/p Contact
SWITCH
25 On flow decrease – O/p Contact
26 Accuracy
27 Repeatability
28 Set Point
29 Difference – Fixed / Adjustable
30 Set Point Adjustment – Internal / External
31
32
OPTIONS 33
34
35 Fluid State
36 Flow Min. Maximum
37 Flow Normal
38 Inlet Pressure Operating Maximum
39 Temperature Operating Maximum
SERVICE 40 Sp. Gr. At Oper. Temp.
CONDITIONS 41
42 Molecular Weight
43 Operating Viscosity (Cp)
44 Allowable pressure drop
45 Corrosive Content
46
47 IBR Certification
48 Manufacturer
ITEM DETAILS
49 Model Number
50 Remarks
NOTES:

Vendor’s Seal and Signature

ISO -FORMAT No. Ref. PROCEDURE No. ISSUE No. REV. No. REV. DATE:
DD/SOF/004A/B DD/SOP/008 TO 015 02 01 01/08/2006