Quick Guide On Setup Eztek Portable Panel
Quick Guide On Setup Eztek Portable Panel
Quick Guide On Setup Eztek Portable Panel
Prepared By :
May 2012
1|Page
TABLE OF CONTENTS
1. Objective
2. Equipment’s Involves
3. Equipment’s Setup
4. Procedure for Operating
2|Page
Objective
1. To serve as a quick guide to all ELITE Field Engineers when operating with portable
SRO system dedicated for SOP Logging Unit.
2. This quick guide is only explaining on the hardware system only. Thus, to operate or
use the software or acquisition system (Warrior Version 7 above) must be acquired
from the specific manual.
Equipment’s Involve
1. EZTEK SAFETY PANEL EZ3110C S/N: 1482
2. EZTEK SHOOTING GR/CCL PANEL EZ5507A S/N: 1483
3. EZTEK EZLOG PANEL EZ3943C S/N: 1485 * Not utilize in this setup
4. EZTEK PERFORATING PANEL EZ3015E S/N: 1484
5. DRS013 PANEL S/N: 218636
6. MIB001 BOX
7. DEPTH/TENSION INTERFACE BOX (EZTEK) * Not utilize in this setup
3|Page
Equipment’s Setup
EZTEK + DRS013
EZTEK SHOOTING
GR/CCL PANEL
DRS013 PANEL
EZTEK PERFORATING
PANEL
4|Page
EZTEK + DRS013 REAR VIEW
5|Page
WIRELINE IN FROM CIS BOX. TO BE
CONNECT IF USING SHOOTING
GR/CCL OR PERFORATING CCL
6|Page
SIGNAL OUT BANANA PIN TO 7 WAY BINDER
CONNECTOR MIB001
# Colour Description
# Colour Description
PCCL LINE
7|Page
Procedure for Operating DRS013+EZTEK FOR SHOOTING GR/CCL AND
PERFORATING CCL
1. To operate the panel. Turn on all the required panel. For DRS013, only turn ON the
power and DO NOT POWER UP VOLTAGE. Selective switch Post / Neg should be put
in the middle.
2. Open the Warrior Acquisition. Select the services and edit the toolstring.
- GammaGun_DRS013_Eztek service
- Passive_CCL_RS013_Eztek service
3. Put the SAFETY PANEL KEY & PERFORATING PANEL KEY in OPERATE POSITION.
4. If choose GammaGun (Titan) service, Rotate the TWO switch at PERFORATING
PANEL to BY PASS & CORRELATE
5. Push OVERRIDE BUTTON at SHOOTING GR/CCL PANEL after set the required voltage
50-60 V.
6. Select the dataset in the Warrior Acquisition and Start Monitor the Sensor Output
and can begin record log.
7. If choose PCCL (Titan) service, Rotate the TWO switch at PERFORATING PANEL to
PERFORATE & CORRELATE.
8. Select the dataset in the Warrior Acquisition and Start Monitor the Sensor Output
and can begin record log.
9. Once ready to Make Shooting, stop at the require depth.
10. If choose GammaGun (Titan) service - Rotate the TWO switch at PERFORATING
PANEL to NEGATIVE & PERFORATE. Once Rotate to PERFORATE, the OVERRIDE
BUTTON at the SHOOTING GR/CCL PANEL will be off indicate power has been cut.
11. If choose PCCL (Titan) service - Rotate the TWO switch at PERFORATING PANEL to
POSITIVE/NEGATIVE & PERFORATE.
12. TURN THE PERF POWER SWITCH ON AT THE PERFORATING PANEL
13. If use Dump Fire Method – Variac Knob must be preset at the required position pre-
determined during Hot Check. Push FIRE #1 & FIRE #2 simultaneously and PRESS
Dump Fire Button. HOLD few seconds until you observe current indicate SHORT.
14. If use Ramp Up Method – Push FIRE #1 & FIRE #2 simultaneously and turn the
Variac Knob slowly to achieve the require Voltage / Current until you see indication
of Gun Fire / Setting Tool Set.
15. Once confirmed, TURN OFF THE PERF POWER SWITCH AT THE PERFORATING PANEL.
Follow steps 4, 5 & 7 and continue log.
END OF PROCEDURE