FIMER PVS-50-60-TL EN Rev C

Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

Solar inverter

PVS-50/60-TL
The PVS-50/60-TL is FIMER’s cloud connected
three-phase string solution enabling cost
efficient large decentralized photovoltaic systems
for both commercial and utility applications.

From 50 to 60 kW
String inverter - PVS-50/60-TL

This new addition to the PVS string inverter family, with 3 The Installer for Solar Inverters mobile app and configuration wizard
independent MPPT and power ratings of up to 60 kW, has been enable a quick multi-inverter installation, saving up to 70%
designed with the objective to maximize the ROI in large systems commissioning time.
with all the advantages of a decentralized configuration for both
rooftop and ground-mounted installations. Fast system integration
Industry standard Modbus (RTU/TCP)/SUNSPEC protocol enables
Compact design fast system integration. Two ethernet ports enable fast and
Thanks to technological choices aimed at optimizing installation future-proof communication for PV plants.
times and costs, the product design features the power module and
wiring box enclosed in a single compact chassis thus saving Plant portfolio integration
installation resources and costs. Monitoring your assets is made easy, as every inverter is capable to
The inverter comes in multiple versions also allowing the possibility connect to Aurora Vision cloud platform to secure your assets and
to connect to third-party DC string combiners. profitability in long term.

Ease of installation Highlights


The horizontal and vertical mounting possibility creates flexibility for • Up to 3 independent MPPT
both rooftop and ground mounted installations. • Two power ratings: 50 kW at 400 Vac and 60 kW at 480 Vac
Moreover the cover is equipped with hinges and locks that are fast • Horizontal and vertical installation
to open and reduce the risk of damaging the chassis and interior • Easy access to wiring box thanks to hinges and cam latches
components when commissioning and performing maintenance positioned on cover
actions. • Power module and wiring box in a single compact chassis
• Wi-Fi interface for commissioning and configuration
Advanced cloud connected features • Reactive power management capability
Standard wireless access from any mobile device makes the • Remote monitoring and firmware upgrade via Aurora Vision cloud
configuration of inverter and plant easier and faster. Improved user platform (logger free)
experience thanks to a built-in User Interface (UI) enables access to • Provides 10% extra power in case of limited ambient temperature
advanced inverter configuration settings. • Improved operating altitude. Can work up to 4000 mt.
• Built-in dynamic export limitation control algorithm

PVS-50/60-TL string inverter block diagram

CH1+ CH1+
MPPT 1
IN1+ IN1+
CH2+ CH2+ CH1+
Grid parallel relays
CH3+ CH3+
IN1- IN1- DC/DC DC/AC
Inverter Line Grid leakage DSP DSP
CH- CH- Bulk caps (DC/AC) filter current readings Controller Controller

L1
MPPT 2
L2
CH2+
L3

DC SPD DC SPD
(monitored) (monitored) Bulk INV
MPPT 3 Voltage Voltage//
Bulk Readings//R_ISO Current
CH3+ Voltage Readings Readings
Readings//R_ISO (for INV) N
Readings
Standard version Version -S DC (for BST)
Current
AC SPD
readings
signal
IN1A(+) IN1A(+) check
IN1B(+) Grid Voltage
IN1B(+)
CH- Readings
IN1C(+) IN1C(+)
IN1D(+) IN1D(+) PE
IN1E(+) IN1E(+)

IN1A(-) CH1+ IN1A(-) CH1+


IN1B(-) IN1B(-) DC/DC DC/AC
IN1C(-) DSP DSP
IN1C(-) contr.
contr.
IN1D(-) IN1D(-) DC Current readings
IN1E(-) IN1E(-)
AC SPD signal check

IN2A(+) IN2A(+)
IN2B(+) IN2B(+) Control Circuit
IN2C(+) CH2+ IN2C(+) CH2+
IN2D(+) IN2D(+)
IN2E(+) IN2E(+)
1_RS-485
+ T/R
IN2A(-) IN2A(-)
IN2B(-) IN2B(-) - T/R
IN2C(-) IN2C(-) GND
IN2D(-) IN2D(-)
IN2E(-) IN2E(-) 2_RS-485

IN3A(+) IN3A(+)
µP + T/R
- T/R
IN3B(+) IN3B(+)
CH3+ GND
IN3C(+) CH3+ IN3C(+)
IN3D(+) IN3D(+) Remote control
IN3E(+) IN3E(+)
+ R1
IN3A(-) CH- IN3A(-) CH- + R2
IN3B(-) IN3B(-) GND
IN3C(-) IN3C(-)
IN3D(-) IN3D(-) Alarm
IN3E(-) IN3E(-) N.C
Communication N.O
platform
C

Aux
DC SPD DC SPD N.C
(monitored) (monitored) N.O
RS-485 Ethernet Ethernet C
(Main) WLAN

Version -SX Version -SX2 Communication and control board


 String inverter - PVS-50/60-TL

Technical data and types


Type code PVS-50-TL PVS-60-TL

Input side

Absolute maximum DC input voltage (Vmax,abs) 1000 V

Start-up DC input voltage (Vstart) 420…700 V (Default 420 V) 420…700 V (Default 500 V)

Operating DC input voltage range (Vdcmin...Vdcmax) 0,7xVstart ...950 V (min 300 V) 0,7xVstart ...950 V (min 360 V)

Rated DC input voltage (Vdcr) 610 Vdc 720 Vdc

Rated DC input power (Pdcr) 52000 W 61800 W

Number of independent MPPT 3 (version SX and SX2) / 1 (versione standard e S)

Maximum DC input power for each MPPT (PMPPT, max) 19300W@30°C / 17500W@45°C 23100W@30°C / 21000W@45°C

MPPT input DC voltage range (VMPPTmin ... VMPPTmax) at Pacr 480-800 Vdc 570-800 Vdc

Maximum DC input current (Idcmax) for each MPPT 36 A

Maximum input short circuit current for each MPPT 55 A (165 A in case of parallel MPPT)

Number of DC input pairs for each MPPT 5 (SX and SX2 versions), 1 (standard and S version)

DC connection type Screw terminal block (Standard and -S version) or PV quick fit connector 1) (-SX and SX2 version)

Input protection

Reverse polarity protection Yes, from limited current source

Input over voltage protection for each MPPT Type 2 / Type 1 + 2 (option)

Photovoltaic array isolation control According to local standard

DC switch rating for each MPPT (version with DC switch) 75 A / 1000 V for each MPPT

Fuse rating (version with fuses) / max fuse rating 15A (1000V) / 20A (1000V)

Output side

AC grid connection type Three-phase (3Ph/N/PE or 3Ph/PE), grounded WYE system only

Rated AC power (Pacr @cosf=1 ) 50000 W 60000 W

Maximum AC output power (Pacmax @cosf=1) 55000 W up to 30°C 2)


66000 W up to 30°C 2)

Maximum apparent power (Smax) 55000 VA up to 30°C 2) 66000 VA up to 30°C 2)

Rated AC grid voltage (Vac,r) 400 V 480 V

AC voltage range 320...480 V 3)


384...571 V 3)

Maximum AC output current (Iac,max) 80 A

Contributory fault current 92 A

Rated output frequency (fr) 50 Hz / 60 Hz

Output frequency range (fmin...fmax) 47...53 Hz / 57…63 Hz 4)

Nominal power factor and adjustable range > 0.995; 0...1 inductive/capacitive with maximum Sn

Total current harmonic distortion <3%

Maximum AC cable 95mm2 copper or stranded aluminum

AC connection type Screw terminal block, cable gland (admitted cable diameter 25..44mm)

Output protection

Anti-islanding protection According to local standard

Maximum external AC overcurrent protection 100 A

Output overvoltage protection Type 2

Operating performance

Maximum efficiency (hmax) 98.3% 98.5%

Euro efficiency 98.0% 98.0%

Communication

Embedded communication interfaces 3x RS-485, 2X Ethernet (RJ45), WLAN (IEEE802.11 b/g/n @ 2,4 GHz)

Communication protocol Modbus RTU / TCP (Sunspec compliant); Aurora Protocol

Remote monitoring services Standard level access to Aurora Vision monitoring portal

Advanced features Integrated Web User Interface; Embedded logging and direct transferring of data to Cloud
Technical data and types
Type code PVS-50-TL PVS-60-TL

Environmental

Ambient temperature range -25...+60°C (-13...140 °F) with derating above 45 °C (113 °F) with derating above 45 °C (113 °F)

Relative humidity 4%... 100% condensing

Sound pressure level, typical 75 dB(A) @1 m

Maximum operating altitude 4000 m (13123 ft) with derating above 2000 m / 6561 ft

Physical

Environmental protection rating IP65

Cooling Forced air

Dimension (H x W x D) 750 mm x 1100 mm x 261,5 mm / 29.5” x 43,3” x 10.27”

Weight 68 kg / 150 lbs (SX version)

Mounting system Single mounting bracket

Safety

Marking CE

IEC/EN 62109-1, IEC/EN 62109-2, EN 61000-6-2, EN 61000-6-3, EN 61000-3-11, EN 61000-3-12


Safety and EMC standard
EN 62311, EN 301 489-1, EN 301 489-17, EN 300 328

CEI 0-21, CEI 0-16, DIN V VDE V 0126-1-1, VDE-AR-N 4105, G59/3, DRRG/DEWA, Chile LV/MV
EN 50438, RD 1565, RD 413, UTE C15-7-712-1
Grid standard (check your sales channel for availability)
P.O. 12.3, AS/NZS 4777.3, BDEW, NRS-097-2-1, MEA, PEA, IEC 61727, ISO/IEC Guide 67(System 5)
IEC 61683, VFR-2014, IEC 62116, Synergrid C10/11, IRR-DCC-MV, CLC-TS-50549-1/-2, G99, EN 50549-1/-2

Available product variants

Input connections with terminal blocks


PVS-50-TL PVS-60-TL
+ surge arrester Type 2 in both DC and AC sides

Input connections with terminal blocks + DC switch


PVS-50-TL-S PVS-60-TL-S
+ surge arrester Type 2 in both DC and AC sides

15 quick Input connections + fuses (single pole) + DC switch +


PVS-50-TL-SX PVS-60-TL-SX
surge arresters Type 2 in both DC and AC sides

15 quick Input connections + fuses (both poles) + DC switch +


PVS-50-TL-SX2 PVS-60-TL-SX2
surge arresters Type 2 in both DC and AC sides

Optional available

SPD Type 1 + 2 on the DC side 5) Available Available

Display 6) Available Available

Negative Grounding kit PVS-50/60-GROUNDING KIT PVS-50/60-GROUNDING KIT

1) Please refer to the document “String inverters – Product manual appendix” 4) The Frequency range may vary depending on specific country grid standards
available at www.fimer.com for information on the quick-fit connector brand 5) Article with dedicated part number, only for SX2 version
and model used in the inverter 6) Inverter version with display can be selected by dedicated part number.
2) Due to country specific regulations this value can be limited to the rated value This option in not available in combination with the “SPD type 1+2” option
(50 kW for PVS-50-TL, 60 kW for PVS-60-TL) Remark. Features not specifically listed in the present data sheet are not
3) The AC voltage range may vary depending on specific country grid standards included in the product

FIMER_PVS-50-60-TL__EN_Rev_C 11.05.2021

For more information We reserve the right to make technical changes or We reserve all rights in this document and in the subject
please contact modify the contents of this document without prior matter and illustrations contained therein. Any
your local FIMER notice. With regard to purchase orders, the agreed reproduction, disclosure to third parties or utilization of
representative or visit: particulars shall prevail. FIMER does not accept any its contents – in whole or in parts – is forbidden without
responsibility whatsoever for potential errors or possible prior written consent of FIMER. Copyright© 2021 FIMER.
fimer.com lack of information in this document. All rights reserved.

You might also like