Fehlercodes Liste
Fehlercodes Liste
Level LED Flashes UID FID Type Display Message Description Recommended Action
1 2 1 0x4481 Warning F12001 Handbrake Fault Handbrake is active when direction selected. Release handbrake
1 5 1 0x4541 Warning F15001 Fan Fault No speed feedback from external heatsink fans Check operation of heatsink fans
1 5 2 0x4542 Warning F15002 Low Oil Low Oil Check oil level
1 5 3 0x4543 Warning F15003 Hydraulic filter Hydraulic Filter Check hydraulic filter
1 5 4 0x4544 Warning F15004 Pump Current Low Pump motor is not drawing sufficient current Check pump motor is connected
1 5 5 0x4545 Warning F15005 Isolation Fault Isolation fault detected between logic and power frame Check isolation between low and high voltage circuits
1 5 6 0x4546 Warning F15006 No Motor Speed Signal No speed feedback from motor Check encoder wiring and speed measurement signal
1 5 7 0x4547 Warning F15007 Tow Mode Tow mode has been activated Disable tow mode if not required
1 5 8 0x4548 Warning F15008 Steer Sensor Warning Invalid steer sensor state Check steer sensor wiring
1 5 9 0x4549 Warning F15009 Pulsed Enable Pulsed enable signal not present, unable to enable bridge Check 1kHz pulsed enable signal is received
1 6 1 0x4581 Warning F16001 Throttle Fault (Warn) Warning level throttle fault. Used for Renault Twizy Check throttle wiring and installation.
Throttle appears to be stuck. This fault will clear if throttle starts to
1 6 2 0x4582 Warning F16002 Safety Case 1 Check throttle wiring and installation.
work again.
Throttle appears to be stuck. This fault will latch and can only be
1 6 3 0x4583 Warning F16003 Safety Case 2 Check throttle wiring and installation.
cleared by repairing the throttle and recycling power.
Ensure contactor doesn't exceed maximum current and check
1 6 4 0x4584 Warning F16004 Analogue Output Over Current (warn) Contactor driver over current
contactor wiring
1 6 5 0x4585 Warning F16005 Analogue Output Off with Failsafe (warn) Contactor driver not working Internal hardware fault
Ensure contactor doesn't exceed maximum current and check
1 6 6 0x4586 Warning F16006 Analogue Output Over Temperature (warn) Contactor driver over temperature
contactor wiring
1 6 7 0x4587 Warning F16007 Analogue Output Under Current (warn) Contactor driver unable to achieve current target in current mode Ensure contactor driver current target is within range
1 6 8 0x4588 Warning F16008 Analogue Output Short Circuit (warn) Contactor driver MOSFET short circuit detected Internal hardware fault
BDI remaining charge (0x2790,1) is less than BDI Warning level
1 7 1 0x45C1 Warning F17001 BDI Warning Charge battery
(0x2C30,5)
BDI remaining charge (0x2790,1) is less than BDI Cutout level
1 7 2 0x45C2 Warning F17002 BDI Cutout Charge battery
(0x2C30,4)
Battery voltage (0x5100,1) is less than Under Voltage limit
1 7 3 0x45C3 Warning F17003 Low Battery Cut Charge battery
(0x2C02,2) for longer than the protection delay (0x2C03,0)
Battery voltage (0x5100,1) is greater than Over Voltage limit
1 7 4 0x45C4 Warning F17004 High Battery Cut Charge battery
(0x2C01,2) for longer than the protection delay (0x2C03,0)
Capacitor voltage (0x5100,3) is greater than Over Voltage limit
1 7 5 0x45C5 Warning F17005 High Capacitor Cut Charge battery
(0x2C01,2) for longer than the protection delay (0x2C03,0)
Battery voltage (0x5100,1) is less than rated minimum voltage for
controller for longer than 1s.
1 7 6 0x45C6 Warning F17006 Vbat below rated min Charge battery
NOTE: This fault is sometimes seen at power down.
Battery voltage (0x5100,1) is greater than rated maximum voltage
1 7 7 0x45C7 Warning F17007 Vbat above rated max Charge battery
for controller for longer than 1s.
Capacitor voltage (0x5100,3) is greater than rated maximum voltage
1 7 8 0x45C8 Warning F17008 Vcap above rated max Charge battery
for controller for longer than 1s.
1 7 9 0x45C9 Warning F17009 Motor in low voltage cutback Motor control has entered low voltage cutback region. Charge battery
1 7 10 0x45CA Warning F17010 Motor in high voltage cutback Motor control has entered high voltage cutback region. Charge battery
1 8 1 0x4601 Warning F18001 Device too cold Low heatsink temperature (0x5100,4) has reduced power to motor Allow controller to warm up to normal operating temperature.
1 8 2 0x4602 Warning F18002 Device too hot High heatsink temperature (0x5100,4) has reduced power to motor Allow controller to cool down to normal operating temperature.
3 13 22 0x4F56 Severe F33122 Motor in wrong direction Motor rotation detected as wrong direction. No longer supported Check motor wiring.
3 13 23 0x4F57 Severe F33123 Motor stalled Motor rotation stalled. No longer supported Check motor wiring.
EMCY message received from non-Sevcon node and anonymous
3 14 1 0x4F81 Severe F34101 CANopen anon EMCY level 3 Check status of non-Sevcon nodes on CANbus
EMCY level (0x2830,0) is set to 3.
EEPROM or flash configuration data corrupted and data can not be
4 1 1 0x5041 Very Severe F41001 Bad NVM Data
recovered.
4 1 2 0x5042 Very Severe F41002 VPDO Out of Range VPDO mapped to non-existent or invalid object Check all VPDO mappings (0x3000 to 0x3400)
Set configuration object to valid value. Our of range object can be
4 1 3 0x5043 Very Severe F41003 Static Range Error At least one configuration object is out of range
identified using 0x5621 or Engineering DVT CLI window.
At least one configuration object is out of dynamic range. This is Check all dynamic range objects. Engineering DVT CLI window
4 1 4 0x5044 Very Severe F41004 Dynamic Range Error
where one objects range depends on another object. indicates type of object which is out of range.
4 1 5 0x5045 Very Severe F41005 Auto-configuration Fault Unable to automatically configure I/O and vehicle setup. Check auto configuration objects (0x5810 and 0x5811)
4 1 6 0x5046 Very Severe F41006 Voltage autoconfig error Unable to set battery voltage Check auxillary drives support low voltage configurations
4 2 1 0x5081 Very Severe F42001 Invalid Steer Switches Steering switches are in an invalid state Check steering switches and wiring
4 4 1 0x5101 Very Severe F44001 Line Contactor o/c Line contactor did not close when coil is energized. Check line contactor and wiring
4 4 2 0x5102 Very Severe F44002 Line Contactor welded Line contactor closed when coil is denergized. Check line contactor and wiring
4 5 1 0x5141 Very Severe F45001 Beltloader Fault Unable to change between traction and pump motors on beltloader. Check change over contactors and motor wiring.
4 5 2 0x5142 Very Severe F45002 Ren Signal Fault signalled by Renault vehicle network Check peripheral Renault devices
4 5 3 0x5143 Very Severe F45003 VERLOG VERLOG signal failure Check peripheral Renault devices
4 6 1 0x5181 Very Severe F46001 Digital Input Wire Off Digital input wire-off Check wiring
4 6 2 0x5182 Very Severe F46002 Analogue Input Wire Off Analogue input outside of allowed range (0x46cX) Check wiring
Ensure contactor doesn't exceed maximum current and check
4 6 3 0x5183 Very Severe F46003 Analogue Output Over Current Contactor driver over current
contactor wiring
4 6 4 0x5184 Very Severe F46004 Analogue Output On with No Failsafe Internal hardware failsafe circuitry not working Internal hardware fault
4 6 5 0x5185 Very Severe F46005 Analogue Output Off with Failsafe Contactor driver not working Internal hardware fault
Ensure contactor doesn't exceed maximum current and check
4 6 6 0x5186 Very Severe F46006 Analogue Output Over Temperature Contactor driver over temperature
contactor wiring
4 6 7 0x5187 Very Severe F46007 Analogue Output Under Current Contactor driver unable to achieve current target in current mode Ensure contactor driver current target is within range
4 6 8 0x5188 Very Severe F46008 Analogue Output Short Circuit Contactor driver MOSFET short circuit detected Internal hardware fault
4 7 1 0x51C1 Very Severe F47001 Power Supply Interrupt Not used
4 7 2 0x51C2 Very Severe F47002 Capacitor Precharge Failure Capacitor voltage (0x5100,3) did not rise above 5V at power up Check power wiring
Controller heat sink has reached critical high temperature, and has
4 8 1 0x5201 Very Severe F48001 Heatsink overtemp Allow controller to cool down to normal operating temperature.
shut down.
4 11 1 0x52C1 Very Severe F41101 DSP Encoder Fault Encoder input wire-off is detected. Check encoder wiring
4 11 2 0x52C2 Very Severe F41102 DSP Overcurrent Fault Motor current exceeded controller rated maximum Check motor configuration and wiring
4 11 3 0x52C3 Very Severe F41103 DSP Control Fault Motor controller unable to maintain control of motor Check motor configuration. Ensure motor speed is not too high.
4 11 4 0x52C4 Very Severe F41104 Motor Overspeed Fault Motor control tripped due to motor overspeed Check motor configuration. Ensure motor speed is not too high.
4 11 5 0x52C5 Very Severe F41105 Encoder Alignment Severe Encoder is not aligned properly. Ensure encoder offset is correctly set or re-align encoder
4 12 1 0x5301 Very Severe F42101 CANBUS Fault CANbus fault condition detected on multinode system. Check CANbus wiring
4 12 2 0x5302 Very Severe F42102 Bootup not received CANopen slave has not transmitted boot up message at power up Check status of all nodes on CANbus.
4 12 3 0x5303 Very Severe F42103 LPRX queue overrun CANbus fault condition detected on multinode system. Check CANbus wiring
4 12 4 0x5304 Very Severe F42104 LPTX queue overrun CANbus fault condition detected on multinode system. Check CANbus wiring
4 12 5 0x5305 Very Severe F42105 HPRX queue overrun CANbus fault condition detected on multinode system. Check CANbus wiring
4 12 6 0x5306 Very Severe F42106 HPTX queue overrun CANbus fault condition detected on multinode system. Check CANbus wiring
4 12 7 0x5307 Very Severe F42107 CAN overrun CANbus fault condition detected on multinode system. Check CANbus wiring
4 12 8 0x5308 Very Severe F42108 CAN off bus CANbus fault condition detected on multinode system. Check CANbus wiring
4 12 9 0x5309 Very Severe F42109 Nodeguarding Failed Not used
Check PDOs on all CANbus nodes are configured correctly and
4 12 10 0x530A Very Severe F42110 Short PDO received Received RPDO doesn't contains enough bytes
match up.
4 12 11 0x530B Very Severe F42111 CANopen Heartbeat Failed Heartbeat not received within configured time out (0x1016) Check status of all nodes on CANbus.
4 12 12 0x530C Very Severe F42112 CANopen slave in wrong state CANopen slave has changed to unexpected state Check status of all nodes on CANbus.
4 12 13 0x530D Very Severe F42113 CAN ESTAT set Internal CANbus fault Internal software fault
4 12 14 0x530E Very Severe F42114 SDO HDL Error Internal CANbus fault Internal software fault
4 12 15 0x530F Very Severe F42115 SDO Timeout Error Internal CANbus fault Internal software fault
4 12 16 0x5310 Very Severe F42116 SDO Abort Error Internal CANbus fault Internal software fault
4 12 17 0x5311 Very Severe F42117 SDO State Error Internal CANbus fault Internal software fault
4 12 18 0x5312 Very Severe F42118 SDO Toggle Error Internal CANbus fault Internal software fault
4 12 19 0x5313 Very Severe F42119 SDO Rec Error Internal CANbus fault Internal software fault
4 12 20 0x5314 Very Severe F42120 SDO Len Error Internal CANbus fault Internal software fault
4 12 21 0x5315 Very Severe F42121 SDO Send Error Internal CANbus fault Internal software fault
4 12 22 0x5316 Very Severe F42122 SDO unknown event Internal CANbus fault Internal software fault
4 12 23 0x5317 Very Severe F42123 SDO Bad SRC Internal CANbus fault Internal software fault
4 12 24 0x5318 Very Severe F42124 SDO bad error number Internal CANbus fault Internal software fault