The document provides a display code guide for error codes shown on the PMI-DAU device. The codes are shown as two digits with the first digit indicating the device mode and the second digit specific warnings or errors. Errors range from hardware issues to software exceptions to triggers and data overloads. Resolving the issue typically involves resetting or replacing the unit, reconnecting cables, or checking power supply lines.
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
100%(1)100% found this document useful (1 vote)
1K views
PMI Error Codes
The document provides a display code guide for error codes shown on the PMI-DAU device. The codes are shown as two digits with the first digit indicating the device mode and the second digit specific warnings or errors. Errors range from hardware issues to software exceptions to triggers and data overloads. Resolving the issue typically involves resetting or replacing the unit, reconnecting cables, or checking power supply lines.
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1
DISPLAY CODES FOR THE PMI-DAU
Both Digits: Blocking startup errors
Display Type Description Action HW Error A hardware error exists Reset/Replace Unit IDKey IDKey is not connected or Reconnect/replace 2nd Digit: Warnings and errors Error invalid IDKey Display Description Action Recovered from fatal Check power SW Error exception Reset/Reload App Main supply line A missing supply line A Check power Main supply line B missing supply line B Overload on supply to isolated analog input Overload on supply to non- isolated analog input
Overload on supply to digital I/O
Internal power monitor failed Reset/Replace Unit
Trigger or TDC timeout: Engine is stopped or running at a very low speed Direction change: Engine is reversing Too many trigger pulses: System is incorrectly configured or engine is reversing 1st Digit: Modes Data overload: The system is experiencing data overload – Display Description possible causes: noise on trigger signals Bootloader Mode Trigger inconsistency: Different no. of trigger pulses per revolution Test Mode detected – bad encoder setup or adjustment Configuration Mode Missing configuration: PMI-DAU has not been configured with Normal Mode engine parameters Invalid direction: Engine is running Running/calculating astern