E1CG-488
ISSUED: MAR. 10, 1999
REVISED: OCT. 10, 2002
HOSHIZAKI
STACKABLE CUBER
MODEL IM-240DME
IM-240DWME
IM-240DSME
IM-240XME
IM-240XWME
IM-240XSME
IM-240AME
SERVICE MANUAL
Downloaded from www.Manualslib.com manuals search engine
CONTENTS PAGE
I. SPECIFICATIONS ---------------------------------------------------------------------------------------
---------------------------------------------------------------------------------------1
1
1. DIMENSIONS/CONNECTIONS ------------------------------------------------------------------
------------------------------------------------------------------1
1
[a] IM-240DME (Air-cooled) -----------------------------------------------------------------------
-----------------------------------------------------------------------1
1
[b] IM-240DWME (Water-cooled) ----------------------------------------------------------------
----------------------------------------------------------------2
2
[c] IM-240DSME (Remote Air-cooled)----------------------------------------------------------
Air-cooled) ----------------------------------------------------------3 3
[d] IM-240XME (Air-cooled) -----------------------------------------------------------------------
-----------------------------------------------------------------------4
4
[e] IM-240XWME (Water-cooled) ----------------------------------------------------------------
----------------------------------------------------------------5
5
[f] IM-240XSME (Remote Air-cooled) ----------------------------------------------------------
----------------------------------------------------------6
6
[g] IM-240AME (Air-cooled) -----------------------------------------------------------------------
-----------------------------------------------------------------------7
7
2. CONDENSER UNIT URC-240C-E --------------------------------------------------------------
--------------------------------------------------------------8
8
E1CG4880210 i
ii E1CG4880210
E1CG4880210 iii
1. DIMENSIONS/CONNECTIONS
E1CG4880210 1
2 E1CG4880210
E1CG4880210 3
4 E1CG4880210
E1CG4880210 5
6 E1CG4880210
E1CG4880210 7
SPECIFICATIONS
MODEL: URC-240C-E
WEIGHT Net 20 kg
CONDENSER Air-cooled
8 E1CG4880210
1. CONSTRUCTION
Power Cord
Front Panel Condensing Unit
Bin Door
Handle
Storage Bin (Optional)
Adjustable Legs
Water Valve
Evaporator
Actuator Toggle Switch
Bin Control Switch
Air-cooled Condenser
Water Plate
Water Tank Fan Motor
Compressor
Pump Motor
Drain Pan
Control Box
E1CG4880210 9
Top Panel
Power Cord
Front Panel Condensing Unit
Bin Door
Handle
Storage Bin (Optional)
Adjustable Legs
Water Valve
Actuator Toggle Switch Evaporator
Water Plate
Water Tank Compressor
Water-cooled Condenser
Pump Motor
Control Box
10 E1CG4880210
Top Panel
Bin Door
Handle
Storage Bin (Optional)
Adjustable Legs
Water Valve
Evaporator
Actuator Toggle Switch
Bin Control Switch
Water Plate
Water Tank Access Valve
Actuator Motor
E1CG4880210 11
Front Panel
Bin Door
Handle
Adjustable Legs
Power Cord
Compressor
Fan Motor
Water Valve
(Backside)
Evaporator Condenser
Water Plate
Water Tank
Drain Pan
12 E1CG4880210
IMPORTANT
If receiving a service call, ask the user to turn off the power to the icemaker and
turn it on again, while watching the icemaker. This will reset the controller, and
in some cases normal operation will resume.
CAUTION
1. Check that the icemaker has been earthed properly. If not, the Controller
Board will not work properly.
2. Do not change wiring and connections, or the Controller Board will not work
properly.
3. Do not touch the reverse side of the Controller Board and tiny electronic
devices on it.
4. Do not repair the electronic devices and parts on the Controller Board in the
field. Replace the whole board assembly when it fails.
5. To get static free, always touch the metal part of the icemaker before servicing.
Electrostatic Discharge will cause severe damage to the Controller Board.
6. The Signal Ground Wire must be connected to the Shield Plate when replacing
the Controller Board after service.
* Make sure that the board is placed correctly into the guides in the Control
Box. Mis-alignment could cause breakage when replacing the Control Box
Cover.
* Handle the board by the edges only. Do not touch the electric parts and
devices except the Transformer.
E1CG4880210 13
Connector K4
Cube Control VR5
Reset Switch
Signal Ground
Connector K2
Connector K1
ID Number Connector K3
14 E1CG4880210
Relay
Control
All the controls are factory-adjusted. Do not
VR2 - Defrost Control
change setting except when replacing the
VR3 - Backup Timer
board or if the setting has changed. Refer to
VR5 - Cube Control
“[e] CONTROLS AND ADJUSTMENT.”
E1CG4880210 15
Check the power source voltage and the components as shown in the table below.
2. Thermistor CAUTION
(on Evaporator) Thermistor Sensor part is fragile,
glass sealed. Handle with care.
Holder
* Disconnect the Connector K4 on the
Screw
board.
* Remove the screw and the Thermistor
Holder on the Evaporator.
* Immerse the Sensor part in a glass 5 -7 kilohms
containing ice and water for 5 minutes.
* Check the resistance between K4
Connector Pins.
* Replace the Thermistor in its correct
position.
Evaporator * Connect K4.
Thermistor
3. Bin Control Switch Manually set the Micro Switch in the Approx.
TRIP and RESET positions, and check TRIP(Closed) 10 sec.
the period. RESET(Open) 80 sec.
16 E1CG4880210
BACKUP TIMER
PUMP MOTOR ON
X4 OFF * Bin Control Switch
FAN MOTOR ON
Freeze Cycle
1 4
Water Pan
X4 ON X4 ON
OPEN
X 1,2 ON X 1,2 OFF
17
X3 OFF X3 ON
CLOSE
2 Defrost Cycle 3
[c] SEQUENCE - LED INDICATORS ON/OFF PATTERN
WATER VALVE ON
X4 ON
* Actuator Toggle Switch moves X 1,2 ON * Cube Control Thermistor
to DEFROST position. X3 ON detects defrost cycle finished.
Relay Legend
X4 OFF * Bin Control Switch X1 - Actuator Motor and Pump Motor
X 1,2 ON tripped during X2 - Hot Gas Valve and Fan Motor
X3 OFF defrost cycle. X3 - Water Valve
X4 - Compressor
[d] FAULT DIAGNOSIS
Check the status of the Service Lamp on the Controller Board (LED-5, See “[c] SEQUENCE”)
by removing the Control Box Cover.
REMEMBER: Hoshizaki controllers are very reliable. They also control every component’s
REMEMBER:
operation. So if a component malfunctions, the controller will respond.
Do not replace controllers in an attempt to shorten the diagnostic process
and not before carefully checking the actual fault and possible cause.
When the icemaker stops, the Controller Board Interlock Indicator shows possible faults.
Cam Arm
18 E1CG4880210
Defrost Cycle
(2) Gas leak Check for leak
Gas
OR
(2) Cam Arm (A) broken Replace
Cam Arm
E1CG4880210 19
A cube control on the Controller Board is factory adjusted to produce constant cubes all year
around.
When the user needs ice cubes with smaller or larger diameter holes, adjust the Variable
Resistor VR5 (Cube Control) using a miniature flat blade screwdriver.
CAUTION
When adjusting the Variable Resistor VR5 for smaller dimple cubes, it may be
necessary to also increase the water supply time to melt away fragments of ice
obstructing the Water Plate which could prevent cubes falling into the Bin.
VR VR VR
20 E1CG4880210
The defrost control regulates the time period between ice-drop and actuator motor restart.
Any adjustment will not be required for normal operation. Factory setting is shown in the table
below. When servicing or replacing the controller board, adjust the Variable Resistor VR2
using a miniature flat blade screwdriver.
When adjusting the Variable Resistor VR5 (Cube Control) for smaller dimple cubes, it may
be necessary to adjust the water supply time setting as well, following the instruction below.
Note: 1. See “II. 2. [a] CONTROLLER BOARD” for location of the Jumper Wires.
2. Any adjustment will not be required under normal use. If an insufficient water supply
results in production of cloudy ice, check to see if the Filter of the Water Valve is
clogged or water pressure is reduced.
3. In some areas where excessively hard water (approx. 250 ppm or more) results in
production of cloudy ice, change the water supply time setting. Also, the Tank Drain
Pipe must be moved to the drain position to prevent concentration of calcium
carbonate, etc. See the figure below.
DEFROST PROCESS FREEZE PROCESS
ON
Approx. 15 sec.
(90 sec. at start up)
E1CG4880210 21
The Condenser Fan Motor rotates at two speeds. The Motor is operated by Relay X6 which
is in turn controlled by the Bimetal Thermostat which is attached to the Control Box. When the
Relay is energised (Thermostat contacts closed), the Motor operates at approximately half
speed. When the Relay is de-energised (Thermostat contacts open), the Motor operates at
full speed.
22 E1CG4880210
WARNING
1. UNPACKING
WARNING
Children should not be allowed in reach of the packaging elements (plastic bags
and expanded polystyrene) as they are potential sources of danger.
CAUTION
Remove shipping carton, tape(s) and packing. If packing material is left in the
icemaker, it will not work properly.
Power Cord
Front Panel Condensing Unit
Louver
(Air-cooled Model)
Bin Door
Handle
Storage Bin (Optional)
Adjustable Legs
Fig. 1
Note: This icemaker needs a Storage Bin. Hoshizaki recommends the following Ice Storage
Bins:
E1CG4880210 23
2) Remove the icemaker panels to gain access to the accessory kit and to assist easier
installation.
a) Front Panel: Remove the screw(s). Lift up and pull toward you.
b) Top Panel: Remove the screw(s). Simply lift off.
c) Side Panel: Remove the screw(s). Slide forward slightly, and
then lift off.
d) Rear Panel: Does not require removal.
Fig. 2
5) Remove the protective plastic film from the exterior. If the icemaker is exposed to the sun
or to heat, remove the film after the icemaker cools.
24 E1CG4880210
WARNING
1. This icemaker is not intended for outdoor use. Normal operating ambient
temperature should be within 1°C to 40°C. Normal operating water
temperature should be within 5°C to 35°C. Operation of the icemaker, for
extended periods, outside of these normal temperature ranges may affect
production capacity.
2. The icemaker should not be located next to ovens, grills or other high heat
producing equipment.
3. The location should provide a firm and level foundation for the equipment.
4. Allow 15 cm clearance at rear, sides and top for proper air circulation and
ease of maintenance and/or service should they be required. For air-cooled
model only, allow 30 cm clearance at the right side.
5. This appliance is not suitable for installation in an area where a water jet
could be used and where dripping is not allowed.
E1CG4880210 25
26 E1CG4880210
Mounting Frame
7) Refit the panels in their correct positions.
Tie
8) Adjust the four legs on the bottom (adjustable Drain Pipe Collar
from 0 to 25.4 mm) to have the icemaker Packing Washer
perfectly horizontal. Use the spirit level. See Drain Pan Bolt
Fig. 9. Bin Control Switch
Fig. 8
Adjust legs
Fig. 9
E1CG4880210 27
WARNING
Check the icemaker models. A D-type icemaker and an X-type icemaker will
be required for stacking two icemakers. A D-type icemaker and two X-type
icemakers will be required when stacking three icemakers. The D-type icemaker
is designed for the upper unit, and the X-type for the middle and lower units.
The D-type and X-type icemakers are provided with two different types of Bin
Control Switch. Use the Bin Control Switch of the lower X-type icemaker only
when stacking icemakers. The Bin Control Switch must be removed from the
upper (and middle) units. Connection of the Bin Control from the lower (and
middle) to the upper unit will require additional connecting leads which are
supplied with the X-type icemaker. Misconnection or no connection may cause
serious damage to the icemaker units, resulting in failure.
1) Prepare and position the Storage Bin as detailed in 1) and 2) in “3. INSTALLATION”.
2) Remove the icemaker panels. The Rear Panel is not required to be removed for installation.
See “1. UNPACKING”.
Extension
6) Secure the lower unit with the two bolts and two Extension
plastic washers provided. See Fig. 10. Drain Hole
8) [P-200SD]
Align the drain hole and the drain pan hole. Handle with care
Drain Pan
Insert the Packing (bin accessory) and fasten Screw Frame
the Drain Pipe Collar (bin accessory) tightly, Washer
28 E1CG4880210
icemakers, this switch will not be required. Drain Pipe Collar Screw Nut
Packing
Keep it after removal. See Fig. 12. Ice Chute
Drain Pan
11) Attach the upper or middle unit on the lower
unit. See Fig. 13.
Drain Outlet
Bolt
12) Secure the two units with the two bolts and the Lower Unit Ice Chute
two nuts provided. See Fig. 13. Bracket
13) Align the lower unit drain hole and the upper
unit drain pan hole. Insert the Packing (lower Fig. 13
unit accessory) and fasten the Drain Pipe Collar
(lower unit accessory). See Fig. 13.
Receptacle Wiring Channel
14) Place the Ice Chute (lower unit accessory) and Plug
Note: If stacking three icemakers, repeat the instructions 10) - 16) for the upper unit.
Remember, only ONE Bin Control is needed regardless of configuration. The Bin
Control extension leads are pre-wired with the plug and will be found coiled in the X-
type wiring channel.
E1CG4880210 29
WARNING
* This icemaker must have a separate power supply or receptacle of 220 - 240V.
* Stacked icemakers should each have a separate receptacle, but they must all be connected
in parallel to the same single phase supply or circuit with sufficient ampacity. In addition
and to avoid nuisance tripping, individual circuit breakers for each machine should not be
used.
* The main control box fuse is rated at 5A and should only be replaced by a qualified service
engineer.
* If the supply cord and the plug should need to be replaced, it should only be done by a
qualified service engineer.
* The wires in the mains lead are coloured in accordance with the following code:
As the colours of the wire in the mains lead of this appliance may not correspond with the
coloured markings identifying the terminals in your plug, proceed as follows:
The wire which is coloured Green-and-Yellow must be connected to the terminal in the plug
which is marked with the letter E or by the symbol or coloured Green or Green-and-
Yellow. The wire which is coloured Blue must be connected to the terminal which is marked
with the letter N or coloured Black. The wire which is coloured Brown must be connected to
the terminal which is marked with the letter L or coloured Red.
* Should the socket outlets in the installation site not be suitable for the plug supplied with
your product, the plug must be removed (cut off if it is moulded on plug) and an appropriate
plug fitted.
30 E1CG4880210
* The non-rewirable plug must never be used without a fuse cover being fitted.
The correct replacement for the detachable fuse cover is identifiable from the manufacturer’s
reference number stamped on the plug.
Supply of replacement fuse covers can be obtained from Hoshizaki Parts/Service Centres.
5) Do not remove the Unit Covers before finishing installation, to prevent damage to the air-
cooled Condenser.
E1CG4880210 31
The Condenser is intended for outdoor use and must be positioned in a permanent well
ventilated site under the following guidelines:
Min. 60 cm clearance
* Select a firm and flat site.
* Normal condenser ambient temperature: +1°C to +40°C. Temperatures not within this
operating range may affect the production capacity of the icemaker.
* The maximum line length is 10 m. For information on longer line installations, call Hoshizaki
Care +44 (0) 1223242254.
* The Condenser should not be installed more than 6 m above the height of the icemaker or
more than 2 m below it.
Note: If the recommended guidelines of the installation are exceeded, the icemaker
performance may be reduced.
[c] INSTALLATION
Note:1.
Note: 1. Tighten the Flare Nuts to a torque of 38±4 Nm.
2. Check the distinction marks on both ends of each copper tubing to make sure the
connections are correct.
3. The tubes should not vibrate. Fix or secure the tubes to prevent stressing.
5) Remove the Service Gauge Port Caps from the Access Valves on the icemaker. Evacuate
the lines through the Gauge Ports for 20 minutes at max. 0.1 torr. Charge both lines with
vapour refrigerant R404A to a pressure of 1 bar. Add nitrogen to raise the pressure to 15
bar. Thoroughly leak test the joints with a leak detector or soap bubbles.
6) Evacuate the lines again at max. 0.1 torr. Vapour charge the lines to 1 - 2 bar with refrigerant
R404A. (The actual charge will depend upon the length of tube run.)
As the total precharged refrigerant amount in the icemaker and remote condenser is 2400
g, the required refrigerant charge will be:
40 g x [length of tube run - 10] m
Example - If the length of tubing run is 15 m (i.e. distance between the icemaker and
Condenser)
15 m - 10 m = 5 m
Base charge = 2400 g (up to 10 m run)
Additional charge = 40 g/m
Required refrigerant charge = 40 g x 5 m = 200 g
On completion of the refrigerant charge, remove the charging cylinder and charging lines.
Refit the Port Caps and tighten to a torque of 10±1 Nm.
E1CG4880210 33
Condenser Unit
Pipe Insulation
Fan Motor Leads
Access Valve
Gas Line
Pipe Insulation
Gas Line
Junction Box
(Fan Motor Access Valve
Leads inside) Fan Motor
Liquid Line
Wiring Cord
Fig. 21
Note: When removing or installing the Nuts on the Access Valves, hold the flat surfaces of the
valve with a spanner as shown below.
Access Valve
Flat Surface
Fig. 22
34 E1CG4880210
WARNING
Cap Gasket
Bushing
Note: The space in the Junction Box is limited. Make the connections outside the Junction
Box before securing the Cord Grip on the Condenser Unit inside by using the Nut
and Bushing provided.
4) Replace the Junction Box Cover in its correct position and secure it with the two screws
provided.
E1CG4880210 35
Drain Outlet
* Only potable water should be used for the (Icemaker dump)
icemaker.
Drainage
* Water supply pressure should be minimum 0.5 Drain Outlet (Bin)
bar and maximum 8 bar. If the pressure
exceeds 8 bar, use a proper pressure reducing
valve. Do NOT throttle back the supply tap. Water Inlet (IM-720)
*Cooling Water Inlet
* A plumbing permit and services of a licensed *Cooling Water Outlet
plumber may be required in some areas. Water Inlet
Elbow
Upper Unit
*Cooling Water Inlet
*Cooling Water Outlet
* The icemaker drain is gravity flow, so ensure Middle Unit
drain pipe has an adequate pitch or fall. Drain Outlet (Upper Unit)
Water Inlet Union
*Cooling Water Inlet
* Water should drain into an open trap. *Cooling Water Outlet
Lower Unit
1) Attach the angled end of white flexible inlet hose (accessory) to the G3/4 fitting on the left
side of the icemaker as indicated, ensuring rubber sealing washer is correctly positioned.
Hand tighten sufficiently to provide leak free joint (Fig. 28).
2) Attach the other end of inlet hose to the water tap (Fig. 29), noting washer is correctly
positioned before hand tightening as above. It is a wise precaution to have a stop valve
within easy reach.
3) Hand tighten grey flexible outlet hose (accessory) onto the R3/4 fitting on the left side of the
Storage Bin as indicated, ensuring rubber washer is correctly positioned to obtain a leak
free joint. The pipe can be cut to length as necessary to suit position of main drain.
Note: Jointing compounds should be approved and suitable for potable water use.
Icemaker
Potable Water
Inlet G3/4
Inlet Hose
Drain Outlet R3/4
(on left side of
Storage Bin)
Inlet Hose
Outlet Hose
Fig. 28 Fig. 29
E1CG4880210 37
* Whilst connecting a water-cooled Condenser to a mains water (potable) supply will not
affect the performance of the machine, it will most certainly cause a high use/waste of a
valuable resource and is not recommended.
* The services of a licensed or coded plumber should be used to ensure a correct installation.
* The connections should be made properly in compliance with the applicable national or
local regulations.
[a] Standard connections according to WRC regulations in U.K. (Fig. 30 and 31)
* When selecting a Cooling Tower, refer to the following peak values of heat flow in the
Condenser:
* Pipes between the Cooling Tower and the icemaker should be at least 20 mm DIA to reduce
pressure loss, even though the icemaker fittings are 13 mm DIA.
* Pressure loss in the water circuit inside the unit will be 5 to 6 m when the cooling water flows
at the ratio of 4 to 5 lit/min.
* Do not use a Cascade Pump, or the Water Regulator will vary the flow and stop it during the
defrost cycle.
[Icemaker Connections]
1) Attach the angled end of white flexible inlet hose (accessory) to the G3/4 fitting on the left
side of the icemaker as indicated, ensuring rubber sealing washer is correctly positioned.
Hand tighten sufficiently to provide leak free joint.
2) Attach the other end of inlet hose to the water tap (Fig. 29), noting washer is correctly
positioned before hand tightening as above.
Note: If filtration or treatment is used, ensure icemaker section only is on treated water
supply, not the Condenser.
38 E1CG4880210
4) By means of a suitable spanner or wrench, tighten the 1/2-3/4 nipples (accessory) into the
Rc1/2 fittings on the left side of the icemaker as indicated. P.T.F.E. tape and/or a suitable
sealing compound should be used to obtain a leak free joint.
Note: Jointing compounds should be approved and suitable for potable water use.
5) Connect the Condenser cooling circuit to the free end of 1/2-3/4 nipples as indicated (Fig.
30) using a suitable rigid type pipe.
Icemaker
Potable Water
Inlet G3/4
Cooling Water
Inlet Rc1/2
1/2-3/4 Nipple
Cooling Water
Outlet Rc1/2
Inlet Hose
Drain Outlet R3/4
(on left side of
Storage Bin)
Bin
Outlet Hose
Fig. 30
Icemaker Cooling
Tower
P
Strainer Pump
Fig. 31
E1CG4880210 39
2) For Condenser connections, use supplied accessory hoses and make the same
connections as 1) to 3) in [a] above to the free end of 1/2-3/4 nipples as indicated (Fig. 32).
Potable Water
Icemaker
Inlet G3/4
Cooling Water
1/2-3/4 Nipple Inlet Rc1/2
Cooling Water
Outlet Rc1/2
Bin
Outlet Hose
Fig. 32
40 E1CG4880210
2) Is the icemaker in a site where ambient temperatures are a minimum of 1°C and maximum
40°C all year around?
3) Is there at least 15 cm clearance around the icemaker for easy maintenance and service?
4) Have all shipping carton, tape(s) and packing been removed from the icemaker?
6) Has the power supply voltage been tested or checked against the nameplate rating?
Has a proper earth been installed to the icemaker?
7) Has the water supply pressure been checked to ensure a minimum of 0.5 bar and maximum
8 bar?
8) Have the compressor hold-down bolts and all refrigerant lines been checked against
vibration and possible failure?
9) Have the Bin Control Switch been checked for correct operation? When the icemaker is
running, push the Detector of the Bin Control Switch. The icemaker should stop within 10
seconds.
E1CG4880210 41
WARNING
1. This icemaker is designed to produce and store edible ice. To keep the
icemaker hygienic:
* Wash your hands before removing ice. Use the Plastic Scoop provided
(accessory).
* The Storage Bin is for ice use only. Do not store anything else in the Bin.
* Clean the Storage Bin before use (see “V. 1. PERIODICAL CLEANING”).
* Keep the Scoop clean. Clean it by using a neutral cleaner and rinse
thoroughly.
* Close the Door after removing ice to prevent entrance of dirt, dust or insects
into the Storage Bin.
4. If the unit is turned off, wait for at least 3 minutes before restarting the icemaker
to prevent damage to the Compressor.
1. START UP
42 E1CG4880210
Before starting the unit, energise the Oil Heater around the lower part of the Compressor to
prevent a starting failure caused by the refrigerant staying inside the Compressor:
1) Move the Washing Switch on the Control Box to the “WASH” position.
Washing
Switch
Control Box
Fig. 33
2) Push the Bin Control Switch to the right into the “bin full” position,
and fix it there with tapes.
4) After 10 seconds in the defrost cycle, the unit stops. Leave the unit
for 12 hours (Oil Heater energised). Fig. 34
5) Move the Washing Switch to the “ICE” position, and release the Bin Control Switch into the
initial “running” position.
Fig. 35
IMPORTANT
2. Do not use ice produced in the trial run. It might be contaminated with foreign
matter in the water circuit. Discard or flush down the drain.
E1CG4880210 43
WARNING
Drain the icemaker to prevent damage to the water supply line at subfreezing
temperatures, using air or carbon dioxide. Shut off the icemaker until proper air
temperature is resumed.
1) Close the water supply tap, and remove the [Normal Position]
Inlet Hose.
Bracket
4) Move the Tank Drain Pipe to the drain Tank Drain
position. See Fig. 36. Pipe
8) Unplug the icemaker or disconnect the power source with the Actuator Toggle Switch in
the “DEFROST” position.
9) Move the Tank Drain Pipe to the normal position, and secure it with the screw.
10) Remove all ice from the Storage Bin, and clean the Bin.
44 E1CG4880210
Bracket
Microswitch
Detector
Fig. 38
E1CG4880210 45
BRACKET COVER
Push the two Pawls and remove the Bracket
Cover.
SWITCH
Pull out the Switch, holding the Rubber Leads
Cap. Handle with care.
SWITCH ACTUATOR
Insert a flat blade screwdriver and wrench it
slightly to pull out the Switch Actuator. Handle
with care to prevent damage to the cam surface
of the Actuator.
DETECTOR
Push out the Detector, holding the Switch
Actuator.
[c] REASSEMBLING
SWITCH ACTUATOR
Insert the lower Shaft and push it along the U
Notch. Check that the Switch Actuator moves
free.
Fig. 39
46 E1CG4880210
WARNING
3. Clean and sanitize the icemaker water system at least twice a year, and
check and clean the Condenser at least once a year.
1. PERIODICAL CLEANING
Wipe the exterior at least once per week with a clean, soft cloth. Use a damp cloth containing
a neutral cleaner to wipe off grease or dirt.
1) Either mix 3 litres of water with 11 ml of 5.25% sodium hypochlorite solution in a suitable
container, or the recommended Hoshizaki sanitiser as directed.
2) Soak the Scoop in the solution for more than 3 minutes. Rinse thoroughly, and shake to
remove surplus liquid.
3) Use a neutral cleaner to wash the Storage Bin Handle. Rinse thoroughly.
4) Soak a clean cloth with the sanitising solution, and wipe the Handle. Use fresh water and
a clean cloth to rinse/dry.
Note: Hoshizaki recommends various types of Storage Bin for the icemaker which vary in
size and design. The following instructions are therefore for general guidance only.
E1CG4880210 47
3) Either mix 5 litres of water with 18 ml of 5.25% sodium hypochlorite solution in a suitable
container, or the recommended Hoshizaki sanitiser as directed.
4) Soak a clean sponge or cloth with the solution, and wipe the Bin liner, Ice Deflector and
Door inner surface.
5) Rinse thoroughly with fresh water and a clean cloth to wipe off the solution. Close the Bin
Door.
Note: Some solutions may cause damage to the Bin liner surfaces or corrosion on the
metal parts. Always rinse the sanitiser unless directed otherwise by Hoshizaki
guidelines.
Plastic mesh Air Filters are fitted to remove dirt or dust from the air, preventing the Condenser
from getting clogged. As the Filters become dirty, air circulation through the Condenser will
be reduced, affecting the icemaker’s performance.
Remove and clean the Air Filters at least twice per month:
1) Unscrew and remove the Front Panel. The Filter is fitted on the inside of the panel behind
the air slots.
2) Unscrew and remove the Louver on the Right Side Panel. The Filter is fitted to the inside
of the plastic Louver.
4) Clean the Air Filters by using a vacuum cleaner. When severely clogged, use warm water
and a neutral cleaner to wash the Air Filters.
5) Rinse and dry the Air Filters thoroughly, and place them back in position.
Air Filter
Louver
Right Side Panel Fig. 40
48 E1CG4880210
Coil
Do not remove
Fig. 41
E1CG4880210 49
Deposits inside the water circuit of the Water-cooled Condenser decrease cooling
performance. Clean inside of the Condenser by circulating a cleaning solution.
CAUTION
Do not use a cleaning solution that will corrode the copper tubing.
In case of contact with the solution, flush with water.
2) Remove the panels and check for leaks from the water line.
3) Unplug the icemaker or disconnect the power source, and close the water supply tap.
4) Disconnect the cooling water inlet and outlet pipings and attach fittings to connect hoses.
5) Disconnect the inlet and outlet tubings of the Water Regulator and replace the Water
Regulator by fittings.
8) Run the pump motor and circulate the solution for a period recommended in the instructions
on label or bottle of the cleaner.
Cleaner
Hose
Condenser
Container
Fig. 42
50 E1CG4880210
To keep the icemaker hygienic, clean and sanitize the icemaking water system at least once
every six months. More frequent cleaning and sanitizing may be required depending on the
water quality.
CAUTION
2. Always wear rubber gloves, eye protectors, apron, etc. for safe handling of
the cleaner and sanitizer.
6. Do not use any ammonia type cleaners on any part of the icemaker.
7. When the ambient and water temperatures are 10°C or below, the Water Pan
may remain open. Warm the icemaking compartment up to 20°C around the
Thermistor.
1) Use a suitable container to dilute 236 ml of the cleaner (“Nickel-Safe Ice Machine Cleaner”
by The Rectorseal Corporation) with 11.4 lit. of water.
2) Open the Storage Bin Door, and remove all the ice to avoid contaminating by the cleaner.
5) Remove the screw, and move the Tank Drain Pipe to the drain
position. See Fig. 36.
6) Push the Bin Control Switch to the right into the “bin full” position.
Hold the switch until the icemaker stops in 10 seconds. See Fig. Fig. 43
43.
E1CG4880210 51
9) After the ice has dropped and the Water Pan begins to close, move Fig. 44
the Washing Switch on the right side of the Control Box to the
“WASH” position. See Fig. 45.
Washing Switch
Control Box
Fig. 45
10) As soon as the Water Pan closes, pour the cleaning solution prepared in 1) carefully into
the Water Pan. Do not splash or spill the solution onto the other parts.
11) Circulate the cleaning solution for 30 minutes. Open the water supply tap, and repeat the
above steps 6) and 7).
12) When the Water Pan closes again, pour clean water into the Water Pan until it floods from
the Overflow Pipe, and circulate the water for 5 minutes.
13) Repeat the above steps 6), 7) and 12) at least three times to rinse thoroughly.
SANITIZING INSTRUCTIONS
14) Use a suitable container to dilute 44 ml of 5.25% sodium hypochlorite solution with 11.4
lit. of water.
15) Repeat the above steps 5), 6) and 7), and close the water supply tap.
52 E1CG4880210
17) Circulate the solution for 15 minutes. Open the water supply tap, and repeat the above
steps 6) and 7).
18) When the Water Pan closes again, pour clean water into the Water Pan until it floods from
the Overflow Pipe, and circulate the water for 5 minutes.
19) Repeat the above steps 6), 7) and 18) at least three times to rinse thoroughly.
20) Move the Tank Drain Pipe to the normal position, and secure it with the screw. See Fig.
36.
22) Replace the Front Panel and Top Panel in their correct
positions. Fig. 46
IMPORTANT
Be sure to operate the Bin Control Switch as specified in 11) and 17) within 40
minutes after the Water Pan closes. After 40 minutes pass, the interlock will
operate to stop the icemaker. (It will not reset automatically.) If the interlock
should operate, disconnect the power source and then reconnect it.
E1CG4880210 53
Water
Valve
Expansion
Valve
Evaporator
Thermistor
Controller
Board Expansion
Valve Bulb
Water Pan
Water Pump
Drier
Condenser
Pressure
Switch
Hot Gas
Fan Motor
Valve Strainer
Compressor
Water Circuit
Refrigerant Circuit
54 E1CG4880210
Water
Valve
Expansion
Valve
Evaporator
Thermistor
Controller
Board Expansion
Valve Bulb
Water Pan
Water Pump
Drier
Condenser
Hot Gas
Valve Strainer
Compressor
Water Circuit
Refrigerant Circuit
E1CG4880210 55
Water Expansion
Valve Valve
Pressure
Switch Bulb
Drier Thermistor
Controller
Access Board
Valve
Connecting
Pipe
Hot Gas
CPR Valve
Fan
Insulation Strainer
Connecting
Con- Pipe
denser
Refrigerant Circuit
56 E1CG4880210
E1CG4880210 57
58 E1CG4880210
E1CG4880210 59
60 E1CG4880210
E1CG4880210 61
62 E1CG4880210
Note: The above data are only for reference in servicing. Actual readings may be
slightly different for each product.
Suction Pressure = Peak readings in freezing cycle
Evaporator Inlet Temp. = 5 minutes before completion of freezing cycle
E1CG4880210 63
1. NO ICE PRODUCTION
PROBLEM CHECK POSSIBLE CAUSE REMEDY
[1] The icemaker a) Power Source 1. OFF position. 1. Move to ON position.
will not start. 2. Loose connections. 2. Tighten.
3. Bad contacts. 3. Check for continuity and
replace.
b) Power Cord 1. Loose connection. 1. Tighten.
2. Open circuit - damaged. 2. Repair or replace.
c) Fuse 1. Blown out. 1. Replace.
d) Bin Control 1. Tripped with Bin filled 1. Remove ice.
with ice.
2. Out of position. 2. Place in position.
3. Fused contacts. 3. Check for continuity and
repair or replace.
e) High Pressure 1. Bad contacts. 1. Check for continuity and
Control replace.
f) Transformer 1. Coil winding opened. 1. Replace.
g) Wiring to 1. Loose connections or 1. Check for continuity and
Controller Board open. replace.
h) Thermistor 1. Leads short-circuit or 1. See “II. 2. [c] BEFORE
open and High CHECKING
Temperature Safety CONTROLLER BOARD”.
(Backup Timer) operates.
i) Hot Gas 1. Continues to open in 1. Check for power OFF in
Solenoid Valve freeze cycle and High freeze cycle and replace.
Temperature Safety
(Backup Timer) operates.
j) Controller Board 1. Defective. 1. See “II. 2. CONTROLLER
BOARD”.
[2] Compressor a) Pressure Switch 1. Dirty Air Filter or 1. Clean.
will not start, or Condenser.
operates 2. Ambient or condenser 2. Check for recommended
intermittently. water temperature too temperatures.
warm (water-cooled).
3. Condenser water 3. Check for recommended
pressure too low or OFF pressure.
(water-cooled).
4. Water Regulating Valve 4. Adjust it lower.
set too high (water-
cooled).
5. Fan not rotating. 5. See 4 - [2] - c).
6. Refrigerant overcharged. 6. Recharge.
7. Refrigerant line or 7. Clean and replace Drier.
components plugged.
8. Bad contacts. 8. Check for continuity and
replace.
9. Loose connections. 9. Tighten.
b) Water Regulator 1. Set too high. 1. Adjust lower.
(water-cooled) 2. Clogged or defective. 2. Clean or replace.
64 E1CG4880210
E1CG4880210 65
66 E1CG4880210
E1CG4880210 67
68 E1CG4880210
E1CG4880210 69
1. EXPANSION VALVE
3) Watch holes of ice cubes produced. Standard setting is that Evaporator inlet side and
outlet side cubes have almost the same diameters. To make the inlet side larger, rotate
90 - 180° clockwise. Smaller, counterclockwise. Do not rotate more than 180° at a time.
CAUTION
Over adjustment of the valve may result in liquid refrigerant return causing freezing
to the suction line and severe damage to the Compressor.
Bulb
Adjust Screw
Bottom View
Solder Connection
Fig. 47
70 E1CG4880210
2) Rotate the Adjust Screw using a flat blade screwdriver so that the pressure gauge shows
19 bar, or the thermometer reads 38 - 40°C, 5 minutes after Freeze Cycle starts.
When the pressure or temperature exceeds the above, rotate the Adjust Screw
counterclockwise.
Adjust Screw
Adjust Screw
Valve Body
Flare
Top View Connection
Bellows
Capillary Tube
Fig. 48
E1CG4880210 71
The compressor must not be opened more than 30 minutes in replacement or service. Do
not mix lubricants of different compressors even if both are charged with the same refrigerant,
except when they use the same lubricant.
If a refrigerant leak occurs in the low side of an ice maker, air may be drawn in. Even if the low
side pressure is higher than the atmospheric pressure in normal operation, a continuous
refrigerant leak will eventually reduce the low side pressure below the atmospheric pressure
and will cause air suction. Air contains a large amount of moisture, and ester oil easily absorbs
a lot of moisture. If an ice maker charged with R404A has possibly drawn in air, the drier
must be replaced.
replaced. Be sure to use a drier designed for R404A.
Repair of the refrigerant circuit needs brazing. It is no problem to use the same handy flux
that has been used for the current refrigerants. However, its entrance into the refrigerant
circuit should be avoided as much as possible.
When processing the copper tubing for service, wipe off oil, if any used, by using alcohol or
the like. Do not use too much oil or let it into the tubing, as wax contained in the oil will clog the
capillary tubing.
Some parts used for refrigerants other than R404A are similar to those for R404A. But never
use any parts unless they are specified for R404A because their endurance against the
refrigerant have not been evaluated. Also, for R404A, do not use any parts that have been
used for other refrigerants. Otherwise, wax and chlorine remaining on the parts may adversely
affect the R404A.
The copper tubes currently in use are suitable for R404A. But do not use them if oily inside.
The residual oil in copper tubes should be as little as possible. (Low residual oil type copper
tubes are used in the shipped units.)
72 E1CG4880210
Never allow the oil in the vacuum pump to flow backward. The vacuum level and vacuum
pump may be the same as those for the current refrigerants. However, the rubber hose and
gauge manifold to be used for evacuation and refrigerant charge should be exclusively for
R404A.
Refrigerant leaks can be detected by charging the unit with a little refrigerant, raising the
pressure with nitrogen and using an electronic detector. Do not use air or oxygen instead of
nitrogen for this purpose, or rise in pressure as well as in temperature may cause R404A to
suddenly react with oxygen and explode. Be sure to use nitrogen to prevent explosion.
1) On the DME/XME and DWME/XWME, attach Charging Hoses, Service Manifold and
Vacuum Pump to the Low-side and High-side (to be fitted by servicer) Access Valves.
Connect the DSME/XSME Charging Hoses as described in “[b] REFRIGERANT
RECOVERY”. If possible, use Quick Release Connectors onto the Access Valves
(especially on the high side).
3) Allow the Vacuum Pump to pull down to a 760 mmHg vacuum. Evacuating period depends
on the pump capacity.
5) Disconnect the Vacuum Pump, and attach a Refrigerant Charging Cylinder to accurately
weigh in the liquid charge. Remember to purge any air from the Charging Hose. See the
Nameplate for the required refrigerant charge.
E1CG4880210 73
6) Open the High-side Valve on the Gauge Manifold, and accurately measure in the liquid
charge. Close the valve on the Charging Cylinder before closing the High-side Manifold
Valve. Any remaining liquid in the line can be charged into the low side.
Note: Always charge in the liquid stage, as many refrigerants are blends and vapour
charging will affect the blend consistency (eg. R404A).
7) Turn on the icemaker. Release the High-side Access Connector, and allow pressure in
the charging line to slowly enter the low side of the system. Cap off the High-side Access
Valve. When pressure reduces on the low side, disconnect the low side charging line
and cap off the Access Valve.
10) Avoid charging large quantities of liquid into the low side in case of damage to the
Compressor.
Depressed
Cap
Access Valve
OPEN
Fig. 49
74 E1CG4880210
3) Recover the refrigerant and store it in a proper container, if required by an applicable law
(See “1. [b] REFRIGERANT RECOVERY”).
4) Remove the Terminal Cover on the Compressor, and disconnect Solderless Terminals.
7) Slide and remove the Compressor. Unpack the new Compressor package.
10) Place the Compressor in position, and secure it using the Bolts and Washers.
11) Remove Plugs from the Compressor Suction and Discharge Pipes.
12) Braze or solder the Access, Suction and Discharge lines (Do not change this order), with
nitrogen gas flowing at the pressure of 0.2 - 0.3 bar.
14) Check for leaks using nitrogen gas (10 bar) and soap bubbles.
15) Evacuate the system and charge it with refrigerant (See “1. [c] EVACUATION AND
RECHARGE”).
16) Connect the Solderless Terminals and replace the Terminal Cover in its correct position.
Note: Hoshizaki recommends that Compressor starting electrics are always replaced at the
same time as the Compressor.
E1CG4880210 75
3) Recover the refrigerant and store it in a proper container, if required by an applicable law
(See “1. [b] REFRIGERANT RECOVERY”).
4) Remove the Drier Holder, if any, and pull the Drier toward you for easy service.
6) Braze or solder the new Drier, with the arrow on the Drier in the direction of the refrigerant
flow. Use nitrogen gas at the pressure of 0.2 - 0.3 bar when brazing tubings.
7) Check for leaks using nitrogen gas (10 bar) and soap bubbles.
8) Evacuate the system and charge it with refrigerant (See “1. [c] EVACUATION AND
RECHARGE”).
Note: Always use a Drier of the correct capacity and refrigerant type.
76 E1CG4880210
IMPORTANT
Always install a new Drier every time the sealed refrigeration system is opened.
Do not replace the Drier until after all other repair or replacement has been
made.
3) Recover the refrigerant and store it in a proper container, if required by an applicable law
(See “1. [b] REFRIGERANT RECOVERY”).
4) Remove the Expansion Valve using brazing equipment. Protect the Evaporator and pipes
from excessive heat with damp cloths or similar.
7) Braze in the new Expansion Valve. Protect the body of the valve from excessive heat, and
use nitrogen at a pressure of 0.2 - 0.3 bar when brazing.
9) Check for leaks using nitrogen gas (10 bar) and soap bubbles.
Fig. 50
E1CG4880210 77
IMPORTANT
Always install a new Drier every time the sealed refrigeration system is opened.
Do not replace the Drier until after all other repair or replacement has been
made.
3) Recover the refrigerant and store it in a proper container, if required by an applicable law
(See “1. [b] REFRIGERANT RECOVERY”).
4) Remove the Water Pan Assembly, referring to “8. WATER PAN ASSEMBLY.”
5) Disconnect the solder connections on the Evaporator using brazing equipment. Protect
the Expansion Valve from excessive heat.
7) Install the new Evaporator, and secure it with the Bolts, Collars (Spacer) and Nuts.
9) Braze pipes, with nitrogen gas flowing at the pressure of 0.2 - 0.3 bar.
10) Check for leaks using nitrogen gas (10 bar) and soap bubbles.
11) Evacuate the system and charge it with refrigerant (See “1. [c] EVACUATION AND
RECHARGE”).
78 E1CG4880210
IMPORTANT
Always install a new Drier every time the sealed refrigeration system is opened.
Do not replace the Drier until after all other repair or replacement has been
made.
3) Recover the refrigerant and store it in a proper container, if required by an applicable law
(See “1. [b] REFRIGERANT RECOVERY”).
7) Braze the new Hot Gas Valve with nitrogen gas flowing at the pressure of 0.2 - 0.3 bar.
WARNING
Always protect the valve body by using a damp cloth to prevent the valve from
overheating. Do not braze with the valve body exceeding 120°C.
9) Check for leaks using nitrogen gas (10 bar) and soap bubbles.
10) Evacuate the system and charge it with refrigerant (See “1. [c] EVACUATION AND
RECHARGE”).
11) Attach the Solenoid Coil to the valve body, and secure it with the screw.
E1CG4880210 79
IMPORTANT
Always install a new Drier every time the sealed refrigeration system is opened.
Do not replace the Drier until after all other repair or replacement has been
made.
4) Recover the refrigerant and store it in a proper container, if required by an applicable law
(See “1. [b] REFRIGERANT RECOVERY”).
5) Cut off the Copper Tube near the Capillary Tube solder connection, using a pipe cutter.
80 E1CG4880210
9) Install the new valve, and insert the Capillary Tubes into the Copper Tube.
10) Web the Copper Tube end, and braze or solder the Copper Tube and Capillary Tubes
together.
12) Check for leaks using nitrogen gas (10 bar) and soap bubbles.
13) Evacuate the system and charge it with refrigerant (See “1. [c] EVACUATION AND
RECHARGE”).
Adjust Screw
Valve Body
Flare
Connection
Bellows
Capillary Tube
Fig. 51
E1CG4880210 81
2) Push the Reset Switch on the Control Box to open the Water Pan.
6) Remove the Water Plate Bracket and the Water Pan Assembly.
7) Remove the two Spring Hook Screws from the Water Tank.
10) Remove the Pump Motor Bracket from the Water Plate.
11) Install the new Water Plate or Water Tank in the reverse order of the removal procedure.
82 E1CG4880210
1 Water Tank
2 Water Plate Bracket
3 Bracket
4 Spring Hook Screw
5 Pump Tubing (Suction)
6 Pump Tubing (Discharge)
7 Pump Motor Bracket
8 Water Plate
9 Overflow Pipe
10 Thumbscrew (for Overflow Pipe)
11 Nylon Tie
12 O-ring
J Pump Motor Assembly
S1 - 4 Tapping Screw
S5 Machine Screw
Fig. 52
E1CG4880210 83
7) Install the new motor or parts in the reverse order of the removal procedure.
8) Plug in the icemaker or connect the power source, and check for leaks.
1 Pump Motor
2 Retainer
3 Mechanical Seal
4 O-ring
5 Fixing Plate for O-ring
6 Packing
7 Impeller
8 Pin
9 Cover
Fig. 53
84 E1CG4880210
7) Install the new valve in the reverse order of the removal procedure.
Note: When replacing parts, disassemble as shown in Fig. 41 (page 49) and replace the
defective parts.
E1CG4880210 85
2) Push the Reset Switch on the Control Box to open the Water Pan.
4) Remove the Extension Spring (Actuator Motor side) from the Cam Arm.
7) Remove the Spring Pin securing the Shaft to the Cam Arm.
9) Install the new Actuator Motor in the reverse order of the removal procedure.
10) Check and adjust so that the Cam Arm normally moves the Actuator Toggle Switch to the
“FREEZE” and “DEFROST” positions (See “II. 2. [b] BEFORE CHECKING
CONTROLLER BOARD”).
86 E1CG4880210
2) Push the Reset Switch on the Control Box to open the Water Pan.
7) Install the new Cam in the reverse order of the removal procedure.
E1CG4880210 87
4) Cut off the Nylon Tie holding the Vinyl Cover Bag.
6) Install the new Actuator Toggle Switch in the reverse order of the removal procedure.
88 E1CG4880210
E1CG4880210 89
90 E1CG4880210
IMPORTANT
[a] MODIFICATION
[b] REPLACEMENT
4) Pull the Shield Plate slightly toward you, and disconnect the Signal Ground wire.
5) Pull out the Controller Board half way, and disconnect the Connectors K1, K2, K3 and K4.
6) Pull out and remove the Controller Board from the Control Box.
7) Install the new Controller Board and reassemble the Control Box in the reverse order of
the removal procedure.
E1CG4880210 91
Bushing
Base
Fig. 55
92 E1CG4880210
3) Remove the Connector K4 on the Controller Board, referring to “14. [b] REPLACEMENT.”
4) Unscrew and remove the Thermistor Holder and Thermistor, located on the Evaporator
(Front Side).
5) Install the new thermistor in the reverse order of the removal procedure, by using a sealant
(High-thermal Conduct Type). See Fig. 56.
Sealant
Holder
* Aluminum Tape
Holder
Holder
** Thermistor and Leads are FRAGILE.
HANDLE WITH CARE. Evaporator
Screw
** Leads
** Thermistor
Fig. 56
E1CG4880210 93
3) Remove two screws at the front bottom of the Control Box, and remove the Control Box
Cover.
7) Install the new Surge Absorber in the reverse order of the removal procedure.
Surge Absorber
Quick Disconnect
Terminal
Fig. 57
94 E1CG4880210
5) Cut the leads of the Fan Motor allowing enough lead length to reconnect using closed end
connectors.
6) Install the new Fan Motor in the reverse order of the removal procedure.
3) Cut the Fan Motor Leads at the connectors in the Junction Box.
4) Release the Fan Motor Bracket and the Fan Motor, pulling the cut leads from the Junction
Box.
5) Install the new Fan Motor in the reverse order of the removal procedure.
6) Reconnect the Fan Motor Leads to the Fan Wiring Cord using new closed end connectors.
E1CG4880210 95