0% found this document useful (0 votes)
43 views1 page

TM570

The document provides instructions for installing two types of posts with reflective sheeting: 1. Type 1 post involves installing a target and wrapping the cylindrical post with 4-inch wide reflective sheeting bands. 2. Type 2 post involves installing reflective sheeting as shown for a square U-flange post with 1-inch diameter holes and fastening it with lag screws. 3. Both post types involve placing reflective sheeting 18 inches above the ground line to clearly identify the edge of the barrier at night or in poor weather.

Uploaded by

nim co
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
43 views1 page

TM570

The document provides instructions for installing two types of posts with reflective sheeting: 1. Type 1 post involves installing a target and wrapping the cylindrical post with 4-inch wide reflective sheeting bands. 2. Type 2 post involves installing reflective sheeting as shown for a square U-flange post with 1-inch diameter holes and fastening it with lag screws. 3. Both post types involve placing reflective sheeting 18 inches above the ground line to clearly identify the edge of the barrier at night or in poor weather.

Uploaded by

nim co
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

3 •" Install reflective sheeting as shown Install target and reflective sheeting

2•" for the Type 2 post as shown for the Type 1 post
2" 2"
Reflective sheeting 4" wide reflective 1Œ" ‚" dia. holes

4
sheeting bands wrapping

"1

"1
ƒ"
(8 req'd.)
Flexible
"4

"4
around cylindrical post Retroreflective Barrier marker

18"

18"
2" plastic post (color of barrier marker
"

"

4‚" 3‚"4‚"
U-Flange post and reflective material shall be the

13 ‚"
13 ‚"

13 ‚"
"1
Wood post (see steel post detail) color of the adjacent edge line)

" 4

5"

5"
9"

9"
"
13 ‚"
2 ‚"

1"

1"
ƒ" Š" dia. holes & fasten
3" - 4" wide 3" - 4" diameter Conc. Barrier
with 4 (‚" x 2") lag screws
TARGET (Use 2 lag screws, centered, for
Ground Line Ground Line 3ˆ" 2ˆ" Ground Line Wood post
circular section plastic delineators.
Lag screws shall be at least 2" longer Ground Line
For "B-3" than the diameter of the circular section.
reflector Do not compress or deform circular
pattern, install section when tightening lag screws)
2nd target
See inst. See inst. TYPE - 1 TYPE - 1 U
detail detail ALTERNATE 1 ALTERNATE 2

TYPE - 4 TYPE - 5
TYPE - 2 TYPE - 3 STEEL POSTS GUARDRAIL AREAS (WITH WOOD POSTS) CONCRETE BARRIER AREAS
2017

(Install barrier markers at 50' spacing unless otherwise noted in plans)


FLEXIBLE PLASTIC POSTS
3-
1-

NOTES: GENERAL NOTES:


2' norm.

Edge ofshl
Type 1,1U & 2 -7'Mi
8' max.
POST: 1. Spacing shall be measured along the shoulder.
as dir.
dgn

Galv. steel, nominal weight Type 1, 2 lb/ft,


Type 1 U, 1.12 lb/ft. 2. On roads with less than 500 vehicle ADT, delineators are not to be
TM570.

4'(
used except where situations such as sharp horizontal curves, etc. exist.

dr
+/
See Standard Drawing TM571 for steel post dimensions

.orf
-3"
3. To clear driveways, crossroads etc., or for required adjustments
and details.
at ramps and at intersections, either:

ace ofcur
Ground Line (a) vary placement of that post up to 25%
TARGET: of spacing shown, or;

ni
Aluminum sheet, nominal thickness .050". Fasten to post (b) eliminate said post if limit of variation

mum Type 3 -Var


with‰" dia. aluminum blind rivets and washers. must be exceeded.

b
For "B-3" reflector pattern, top target shall overlap bottom 4. Judgement should be exercised in the installation of delineators
Var., dependent on rdwy. sec.
target. in cut section, particularly on roads constructed to older
standards where ditches are narrow and where delineators
REFLECTORS: tend to hamper maintenance operations.
3" x 4" reflective sheeting unless otherwise shown.
iabl

Metal posts, 2' 5. On horizontal curves place delineators nearly opposite each other.
( 3•" x 4" reflective sheeting is an acceptable alternate
e

plastic posts, variable


unless otherwise shown.)
dependent upon make of post 6. At guard rail locations the delineators are to be installed behind
Acrylic prismatic reflectors acceptable on Type 1, 1 U, 2
used and anchorage system. the rail and shall be located adjacent to guard rail posts as shown
and 4 posts and Type 5 barrier mounts. for Type 4 Delineators.
Place required number in sequence from top of target.

INSTALLATION DETAIL 7. Install all delineators with reflectors facing adjacent oncoming traffic.

8. Offset delineators an additional 4' in areas of heavy snow removal operations.

TANGENT HORIZONTAL CURVES 9. Backside Delineators may be used in frequently snow plowed areas
MAX. SPACING EACH SIDE OF ROADWAY IN FEET where use of snow poles is not justified. When Backside Delineators
MAX. SPACING are specified, substitute "W-1" and "W-2" with "W-1B" and "W-2B"
EACH SIDE OF DEGREE respectively, on Type 1 steel posts. Do not install Backside Delineators
ON IN ADVANCE OF & BEYOND CURVE
ROADWAY IN FEET OF on one-way sections of roadway, freeways and ramps, or on radius sections.
CURVE FIRST SPACE
CURVE SECOND SPACE THIRD SPACE
10. Refer to TM 222 for bracket assembly details for Backside Reflector Pattern.
400 Lower Than 1 300 300 300 300
1 230 300 300 300
To be accompanied by Drg. No. TM571, TM575, TM576, and/or TM577 as specified.
2 160 300 300 300
REFLECTOR PATTERN TABLE 3 130 260 300 300 CALC. BOOK NO. N/A SDR DATE
01/06/2012

Color Of Reflector Number Of 4 110 220 300 300


Color Color Of Reflector Number Of 5 100 200 300 300 NOTE: All material and workmanship shall be in accordance with
And Target Or Post Reflectors
Type And Target Or Post Reflectors 6 90 180 270 300 the current Oregon Standard Specifications
On Backside On Backside
7 - 8 80 160 240 300 The selection and use of this
"W-1" White 1
9 - 11 70 140 210 300 OREGON STANDARD DRAWINGS
"W-2" White 2 Standard Drawing, while de-
Standard 12 - 16 60 120 180 300
"Y-1" Yellow 1 e
l
ab be
l 17 - 22 50 100 150 300 signed in accordance with
"Y-2" Yellow 2 pc
i
l ca
Pattern p pi
l 40 80 120 240
tA Ap 23 - 34 generally accepted engineer-
"B-1" Blue 1 No No
t
35 - 53 30 60 90 180 TRAFFIC DELINEATORS
"B-2" Blue 2 ing principles and practices,
TM570

54 & Higher 20 40 60 120


"B-3" Blue 3 is the sole responsibility of
"R-1" Red 1 (Min. spacing 20 feet)
the user and should not be 2021
( Install "W-1" reflective pattern unless otherwise noted. See Standard Drawings TM575 thru TM577
for spacing, layout, and reflective pattern of delineators at interchange ramps, used without consulting a DATE REVISION DESCRIPTION
Backside "W-1B" White 1 White 2
channelized intersections, lane reductions, emergency escape ramps and freeway crossovers.) Registered Professional En-
Pattern "W-2B" White 2 White 2
gineer.
DELINEATOR SPACING TABLE FOR TYPES 1, 1U, 2, and 4
plotfile_TM200s_500s.dgn :: Default 7/10/2020 8:51:29 AM hwyr20m
Effective Date: December 1, 2020 - May 31, 2021 TM570

You might also like