FP-001 Guide
FP-001 Guide
Version 1.0
1
Table of Contents
2
Computer to FP-001
3
Open an executable file you get from us – (example A6-USD4), then hit
Auto(A) to start the programming.
4
Press the Reset/Start Button once to complete the programming.
5
FP-001 to Bill Acceptor
Make sure the Programmer is set to L1 and Normal before Power up.
6
Press the Reset/Start Button Once.
7
Once the Bill Acceptor Cycles, download is complete and L4 will be
solid orange.
At this stage you need to look at the Bezel lights on the Bill Acceptor.
8
Press the Reset/Start Button once and the Bill Acceptor will cycle to
complete the programming.
If the Bezel Lights are solid Green, this means you need to calibrate the Bill
Acceptor.
9
Press the Reset/Start Button Once.
Solid orange L4 light will go out and come back solid orange again.
10
Take your Calibration Card making sure you inset it in the direction of the
arrows pointing.
Put the Calibration Card all the way inside the Bill Acceptor till it stops.
The Bill Acceptor will take the Calibration Card through its calibration stage
witch takes about 5 seconds. (Depending on the Bill Acceptor Model)
Once the Calibration Card is sent back out and the Bill Acceptor is not
taking it, remove the Card from the Bill Acceptor.
11
Press the Reset/Start Button Once.
12
Press the Reset/Start Button Once.
The Bill Acceptor will cycle and the Bezel lights will be blinking green
confirming successful programming and calibration.
13