12 V version - 0000139
24 V special version - 0000527
Option automatic adapter - 0000521
Option master-slave adapter - 0000133
Revision Page
Design review
Neue Art.Nr eingepflegt R10
Hardware
Generator Revision Modification Strike Plate Date Upgrade
Created by
Fischer Panda GmbH - Head of Technical Documentation
Otto-Hahn-Str. 32-34
33104 Paderborn - Germany
Phone: +49 (0) 5254-9202-0
E-Mail: [email protected]
web: www.fischerpanda.de
Copyright
Reproduction and modification of the manual is permitted only after agreement with the manufacturer!
Fischer Panda GmbH, 33104 Paderborn, reserves all rights regarding text and graphics in this document. Details
are given to the best of our knowledge. No liability is accepted for correctness. Please note: technical modifications
aimed at improving the product may be implemented without prior notice. Therefore, it must be ensured prior to
installation that the pictures, diagrams and related material are applicable to the genset supplied. In case of doubt,
verify upon delivery that documentation and equipment match.
Hardware ................................................................................................................................. 2
3 Measurements.............................................................................................................. 27
3.1 Hole pattern .................................................................................................................... 27
The settings described here can by performed by the operator, unless otherwise indicated.
The installation should be carried out by specially trained personnel or by authorized repair shops (Fischer Panda
service points).
Danger for life! - The generator can be equipped with a Warning! Automatic start
automatic start device. This means expected starting of
the generator, the starter battery must the generator can
be started by an external signal. To avoid an unexpected
starting of the generator, the starter battery must be
disconnected before start working at the generator.
The generator must not be put into operation with cover Warning!
removed.
Danger for Life. Improper handling, operation, Warning! Danger of Life - High voltage
installation and maintenance can result in severe
personal injury and/or material damage.
2. General operation
2.1 Panel Generator Control
01 02 03 04 05 06 07
08 09 10
11 12 13 14 15
01. LED for coolant temperature red1 08. LED for pre-glow „heat“ orange1
02. LED for water leak red/yellow1 (sensor optional) 09. LED for Generator „start“ green1
1
03. LED for AC-voltage fault red/yellow 10. LED for Generator „stand-by“ green1
04. LED for AC-voltage ok green1 11. Push button for pre-glow „heat“
12. Push button for Generator „start“
05. LED for winding temperature red1
13. Operating hours counter
06. LED for oil pressure red1 14. Push button panel „off“
07. LED for battery charge voltage fault green/red1 15. Push button panel „on“
1
LED green: normal operation mode, LED red: fault, LED yellow: warning, LED orange: active
01 02
03 04
01 02
03
04 05 06
2.3.1 Placement.
Install the remote control panel at a dry, good accessible and shady place.
Connect the remote control panel to the standard 12 core cable at the generator. (1:1)
The solder jumpers are marked on the printed circuit board (with jumper no. and at three-part solder jumper with soldering surface no.)
(1): Equivalent resistance for load control lamp e.g. for use with three-phase alternator also integrated automatic controller of Bosch. The resistance value is 68 Ω 3 W,
i.e. only for 12 V.
(2): A closed contact switches the appropriate input to GND.
Fig. 2.3.4.1-1: Settings of soldered jumper for this configuration (column Conf.)
The solder jumpers are marked on the printed circuit board (with jumper no. and at three-part solder jumper with soldering surface no.)
(1): Equivalent resistance for load control lamp e.g. for use with three-phase alternator also integrated automatic controller of Bosch. The resistance value is 68 Ω 3 W,
i.e. only for 12 V.
(2): A closed contact switches the appropriate input to GND.
Fig. 2.3.4.2-1: Settings of soldered jumper for this configuration (column Conf.)
The solder jumpers are marked on the printed circuit board (with jumper no. and at three-part solder jumper with soldering surface no.)
(1): Equivalent resistance for load control lamp e.g. for use with three-phase alternator also integrated automatic controller of Bosch. The resistance value is 68 Ω 3 W,
i.e. only for 12 V.
(2): A closed contact switches the appropriate input to GND.
Fig. 2.3.4.3-1: Settings of soldered jumper for this configuration (column Conf.)
The solder jumpers are marked on the printed circuit board (with jumper no. and at three-part solder jumper with soldering surface no.)
(1): Equivalent resistance for load control lamp e.g. for use with three-phase alternator also integrated automatic controller of Bosch. The resistance value is 68 Ω 3 W,
i.e. only for 12 V.
(2): A closed contact switches the appropriate input to GND.
Fig. 2.3.4.4-1: Settings of soldered jumper for this configuration (column Conf.)
The solder jumpers are marked on the printed circuit board (with jumper no. and at three-part solder jumper with soldering surface no.)
(1): Equivalent resistance for load control lamp e.g. for use with three-phase alternator also integrated automatic controller of Bosch. The resistance value is 68 Ω 3 W,
i.e. only for 12 V.
(2): A closed contact switches the appropriate input to GND.
Danger for life! - The generator can be equipped with a Warning!: Automatic start
automatic start device. This means the generator can be
started by an external signal. To avoid an unexpected
starting of the generator, the starter battery must be dis-
connected before start working at the generator.
Never switch off the battery until the generator has Attention!
stopped, if necessary close fuel valve!
03
02
01
2.6.1 Function:
The automatic adapter RE0704 extends the generator control panel P6+ with an automatic input. A potential-free
contact can be attached to this input. If this contact is closed, then the generator, which is attached to the generator
control panel P6+, is started automatically. If the contact is opened, then the generator is stopped automatically.
The automatic starting procedure consists of pre-heating (heat) and operating the starter (start). It can be again
aborted at any time by opening the contact at the automatic input.
For automatic stopping (stop) the output “Fuel pump” (clamp 9 generator control panel) is switched off. The time for
the automatic stop procedure can be terminated only by switching off generator control panel prematurely.
The times for “heat”, “start” and “stop” are separately adjustable (see below).
The additional automatic adapter switched on and off using the generator control panel with its push buttons “on”
and “off”.
If the contact at the automatic input is connected, while the generator control panel is switched on, then the
automatic starting procedure is carried out.
If the power supply is attached or switched on using the generator control panel, while the contact of the automatic
input is closed, then the automatic starting procedure won't be carried out, because the generator control panel is
always switched off after attaching the power supply (generator the control panel must have been separate from the
power supply for at least 60 s).
Data:
Parameter Information
Operation voltage The automatic adapter power is supplied via the generator control panel P6+. The same absolute
maximum ratings obtain as with the generator control panel P6+.
Operation temperature The same absolute maximum ratings obtain as with the generator control panel P6+.
Proper power consumption 10 mA - 20 mA
Tolerance of times ± 10 %
Connection for the automatic adapter X2 (row with odd pin numbers // I/O view from operating panel)
02
01
02
01
With the Master-Slave-Adapter RE0706 two Generator Control Panels P6+ RE0703 can be connected to a Master-
Slave-Combination. In addition on each Generator Control Panel P6+ an Master-Slave-Adapter RE0706 is installed.
The Generator Control Panel P6+ is interconnected by the 14pole connecting terminals on the Master-Slave-
Adapters 1:1. The Master-Panel is hereby defined when the generator is connected to the main connector. Thus, the
main connector of the Slave-Panel should not be occupied (unconnected).
The solder jumpers on the Master-Panel have to be coded in the same manner as for a Master-Panel without a
Slave-Panel as in normal operation. The solder jumpers on the Slave-Panel are coded as for slave operation (please
see the appropriate adjustment pages for the Generator Control Panel P6+ RE0703).
The Master-Panel and Slave-Panel are identical, and only differs as a result of the coding. Both Master-Slave-
Panels are also identical.
2.7.4 Fuse:
The use of these connections for other purposes, other than the master-slave connection of two generator control
panels, is generally forbidden. In individual cases, after consultation and clarifying the technical details, a release for
another use can, if technically possible, be allowed.
2.7.5.2 Terminal X3
Fig. 2.7.5.2-1: Terminal connections terminal X3
Notes:
1.Power rating of the output: max. 0,5 A in continuous operation and briefly 1,0 A.
2.The supply of all output currents may not exceed (less 0,2 A power consumption) the rated current of the safety device of the control panel.
3.The output has a free wheeling diode, which short circuit negative voltages (related to GND).
4.The output has a Z-diode, which prevents an overvoltage (related to GND) into the output.
Fig. 2.7.6-1: Settings of soldered jumper for this configuration (column Conf.)
The solder jumpers are marked on the printed circuit board (with jumper no. and at three-part solder jumper with soldering surface no.)
X = Jumper must be so set
XM = Jumper, function must be so set on the master panel is selected
M = Jumper must be set exactly the same, as on the master panel,
(1): Equivalent resistance for load control lamp e.g. for use with three-phase alternator also integrated automatic controller of Bosch. The resistance value is 68 Ω 3 W,
i.e. only for 12 V.
(2): A closed contact switches the appropriate input to GND.
Fig. 2.7.6.2-1: Settings of soldered jumper for this configuration (column Conf.)
The solder jumpers are marked on the printed circuit board (with jumper no. and at three-part solder jumper with soldering surface no.)
X = Jumper must be so set
XM = Jumper, function must be so set on the master panel is selected
M = Jumper must be set exactly the same, as on the master panel,
(1): Equivalent resistance for load control lamp e.g. for use with three-phase alternator also integrated automatic controller of Bosch. The resistance value is 68 Ω 3 W,
i.e. only for 12 V.
(2): A closed contact switches the appropriate input to GND.
10.5.17
Q:\Zeichnungen\7067e01.idw
6 5 4 3 2 1
Measurements
D D
25
,5
185
Q3
Hole pattern
4x
3. Measurements
88
95
95
105
87
177
C C
185
195
B 175 B
Maßstab: Gewicht:
Material: Halbzeug:
Otto-Hahn-Str. 32-34 D-33104 Paderborn Tel.: (05254) 9202-0 Artikel Nr.: 21.02.02.009H
Fax (05254) 85724 [email protected] www.fischerpanda.de
Datum Name Panel Generator Control
Bearb. 06.03.2007 jschaefers
A A
Gepr.
Norm.
Allgemeintoleranzen nach Blatt
DIN ISO 2768-mK 2D Zeichnungs Nr. 1
Alle nicht 7067e01
bemaßten Fasen Schutzvermerk nach A3
a=0,5 mm DIN 34 beachten ! Ersatz für Ersetzt durch
Zust. Änderungen Datum Name
6 5 4 3 2 1