Ac Fault
Ac Fault
DOES FAULT No
OCCUR
RESET GENERATOR
DURING
EXPOSURE?
Yes
LET THE No
No IS FAULT GENERATOR IS FAULT
PRESENT? COOL FOR 30 PRESENT?
MINUTES
Yes
Yes
MEASURE VAC
INPUT AT TB1
ON THE AC
1 CHASSIS
No IS THE VAC
CHECK THE VAC
200 VOLTS
AT THE SOURCE
+/- 10%?
Yes
ENABLE THE AC
CHASSIS. MEASURE
THE DC RAILS VIA
TP16 AND TP17 ON
THE SCB PWB
Yes
1
No
DO THE RAILS MEASURE THE
REPLACE THE AC
MEASURE > VOLTAGE AT
CHASSIS. 254 VDC? TP13 ON THE
AC/FIL/FDBL BD.
Yes
MEASURE THE DC
RAILS AT JB1 4 Yes
DOES THE
AND 6 ON THE TEST POINT REPLACE THE AC
AC/FIL/FDBK BD. MEASURE > .1 CHASSIS.
VOLTS?
No
No
DO THE RAILS
REPLACE THE REPLACE THE
MEASURE >
INV CHASSIS. 254 VDC? SCB PWB
Yes
REPLACE THE
MULTIPLIER
CHASSIS.
END