Honeywell Pressure Transmitter STG

Download as pdf or txt
Download as pdf or txt
You are on page 1of 24

ST 3000 Smart Transmitter

Series 100 Gauge Pressure Models


Specifications
34-ST-03-62 August 2011

Introduction
In 1983, Honeywell introduced the first Smart Pressure
Transmitter― the ST 3000®. In 1989, Honeywell launched
the first all digital, bi-directional protocol for smart field
devices. Today, its ST 3000 Series 100 In-line Pressure
Transmitters continue to bring proven “smart” technology
to a wide spectrum of measurement applications. These
transmitters are screwed directly onto a ½” male NPT
nipple. Typical applications include high-pressure
measurement in boilers, fuel feeds, and high-pressure
reaction vessels in the petrochemical and hydrocarbon
recovery industries – any location where accuracy and
reliability are crucial to safe, economical operation.
Honeywell In-line Transmitters offer the ability to be
installed in a wide variety of hazardous environments for
accurate repeatable pressure measurement.
Figure 1 - On the right is Model STG140, STG170 and STG180
Models and on the left is STG14L, STG17L and STG18L.
All Series 100 Gauge Pressure Transmitters feature proven
STG140/STG14L 0 to 500 psi 0 to 35 bar piezoresistive sensor technology.

STG170/STG17L 0 to 3,000 psi 0 to 210 bar

STG180/STG18L 0 to 6,000 psi 0 to 415 bar


Honeywell’s high-performance ST 3000 S100
STG19L 0 to 10,000 psi 0 to 690 bar transmitters lead the industry in:
 Total Accuracy = ±0.0375%
The devices provide comprehensive self-diagnostics to
help users maintain high uptime, meet regulatory  Stability = ±0.01% per year
requirements, and attain high quality standards. S100  Reliability = 470 years MTBF
transmitters are ideal for critical applications, such as  Rangeability = 400 to 1
custody transfer of natural gas and energy and material
 Lifetime Warranty = 15 years.
balances, where accuracy and stability are of the utmost TM
Includes Lifetime Transmitters:
importance.

All ST 3000 transmitters can provide a 4-20 mA output,


Honeywell Digitally Enhanced (DE) output, HART® output,
or FOUNDATION™ Fieldbus output. When digitally
integrated with Honeywell’s Process Knowledge
System™, EXPERION PKS™, ST 3000 instruments
provide a more accurate process variable as well as
advanced diagnostics.
ST 3000 Smart Pressure Transmitter 2

Description Features
The ST 3000 transmitter can replace any 4 to 20 mA  Choice of linear or square root output conformity is a
output transmitter in use today and operates over a simple configuration selection.
standard two-wire system. The measuring means is a  Direct digital integration with Experion PKS and other
piezoresistive sensor, which actually contains three control systems provides local measurement
sensors in one. It contains a differential pressure sensor, accuracy to the system level without adding typical
a temperature sensor, and a static pressure sensor. A/D and D/A converter inaccuracies.
Microprocessor-based electronics provide higher span-
 Unique piezoresistive sensor automatically
turndown ratio, improved temperature and pressure
compensates input for temperature and static
compensation, and improved accuracy.
pressure. Added “smart” features include configuring
lower and upper range values, simulating accurate
The transmitter’s meter body and electronics housing
analog output, and selecting preprogrammed
resist shock, vibration, corrosion, and moisture. The
engineering units for display.
electronics housing contains a compartment for the single-
board electronics, which is isolated from an integral  Smart transmitter capabilities with local or remote
junction box. The single-board electronics is replaceable interfacing means significant manpower efficiency
and interchangeable with any other ST 3000 Series 100 or improvements in commissioning, start-up, and
Series 900 model transmitters. ongoing maintenance functions.

Like other Honeywell transmitters, the ST 3000 features Advanced Diagnostics


two-way communication and configuration capability ST 3000 is now available for both HART® 6 and
between the operator and the transmitter through several FoundationTM Fieldbus with advanced diagnostics that
Honeywell field-rated portable configuration devices, minimize unplanned plant outages, minimize
including the Smart Field Communicator (SFC) and the maintenance costs and by providing the industry’s most
Multiple Communication Configurator (MC ToolKit). reliable transmitter.
 Provide advanced warning of possible failure events
While both are made for in-field use, the MC Toolkit also and avoid costly shutdowns.
can be ordered for use in intrinsically safe environments.
 Three levels of failure reporting

The SCT 3000 Smartline® Configuration Toolkit provides  Comprehensive list of on-board diagnostics (Ref. ST
an easy way to configure instruments using a personal 3000 User manual with HART® 6, 34-ST-25-17 Rev:
computer. The toolkit enables configuration of devices June 09 and FoundationTM Fieldbus option manual
before shipping or installation. The SCT 3000 can operate 34-ST-25-15 Rev: June 09)
in the offline mode to configure an unlimited number of
devices. The database can then be loaded down-line
during commissioning.
ST 3000 Smart Pressure Transmitter 3

Operating Conditions – All Models


Parameter Reference Rated Condition Operative Limits Transportation
Condition and Storage
C F C F C F C F
Ambient Temperature 25±1 77±2 -40 to 85 -40 to 185 -40 to 93 -40 to 200 -55 to 125 -67 to 257
Meter Body Temperature 25±1 77±2 -40 to 110* -40 to 230* -40 to 125 -40 to 257 -55 to 125 -67 to 257
Humidity %RH 10 to 55 0 to 100 0 to 100 0 to 100

Vacuum Region - Minimum


Pressure
mmHg absolute atmospheric 25 2 (short term **)
inH2O absolute atmospheric 13 1 (short term **)
Supply Voltage, Current, Voltage Range: 10.8 to 42.4 Vdc at terminals
and Load Resistance Current Range: 3.0 to 21.8 mA
Load Resistance: 0 to 1,440 ohms (as shown in Figure 2)
Maximum Allowable STG140 and STG14L = 500 psi , 35 bar
Working Pressure (MAWP) STG170 and STG17L = 3,000 psi, 210 bar
(ST 3000 products are rated to
Maximum Allowable Working STG180 and STG18L = 6,000 psi, 415 bar
Pressure)
STG19L = 10,000 psi, 690 bar
Units can withstand overpressure of 1.5X MAWP without damage.

* For CTFE fill fluid the rating is –15 to 110C (5 to 230F)


** Short term equals 2 hours at 70C (158F)
.

1440

1200

Loop 800 Note: A minimum of 250 ohms


Resistance of loop resistance is necessary
(ohms) to support communications.
650 Loop resistance equals barrier
resistance plus wire resistance
plus receiver resistance.
450

250

= Operating Area

0 10.8 16.28 20.63 25 28.3 37.0 42.4


Operating Voltage (Vdc)

Figure 2 - Supply voltage and loop resistance chart


ST 3000 Smart Pressure Transmitter 4

Performance under Rated Conditions* - Models STG140 & 14L (0 to 500 psi)
Parameter Description
Upper Range Limit psi: 500 bar: 35
Minimum Span psi: 5 bar: 0.35
Turndown Ratio 100 to 1
Zero Elevation and No limit except minimum span from absolute 0 (zero) to +100% URL. Specifications
Suppression valid over this range.
Accuracy (Reference – Includes In Analog Mode: ±0.075% of calibrated span or upper range value (URV), whichever is
combined effects of linearity, greater, terminal based.
hysteresis, and repeatability) For URV calibrated below reference point (20 psi), accuracy equals:
• Accuracy includes residual error
after averaging successive   20 psi  or   1.4 bar  in % of span
 0.025  0.05 
   0.025  0.05  
readings.
  span psi    span bar 
• For FoundationTM Fieldbus use
Digital Mode specifications. For For High Accuracy (HA) option: +/- 0.0375% of calibrated span or upper range value
HART use Analog Mode (URV), whichever is greater, terminal based.
specifications.
In Digital Mode: ±0.0625% of calibrated span or upper range value (URV), whichever
is greater, terminal based.
For URV calibrated below reference point (20 psi), accuracy equals:
  20 psi  or   1.4 bar  in % of span
 0.0125  0.05 
   0.0125  0.05  
  span psi    span bar 
* For High Accuracy (HA) option: +/- 0.035% of calibrated span or upper range value
(URV), whichever is greater, terminal based
Zero Temperature Effect per In Analog Mode: ±0.0625% of span.
28C (50F) For URV below reference point of 50 psi for model STG140 or 75 psi for model
STG14L, effect equals:
  50 psi  or   3.5 bar  in % of span
 0.0125  0.05 
   0.0125  0.05  
  span psi    span bar 
OR
  75 psi  or   5.25 bar  in % of span
 0.0125  0.05 
   0.0125  0.05  
  span psi    span bar 

In Digital Mode: ±0.05% of span.


For URV below reference point of 50 psi for model STG140 or 75 psi for model
STG14L, effect equals:

±0.05 (span psi) or ±0.05 ( span bar) in % of span


50 psi 3.5 bar

OR

±0.05 (span psi) or ±0.05 ( span bar) in % of span


75 psi 5.25 bar

Combined Zero and Span In Analog Mode: ±0.10% of span.


Temperature Effect per 28C For URV below reference point of 50 psi for model STG140 or 75 psi for model
(50F) STG14L, effect equals:
  50 psi  or   3.5 bar  in % of span
 0.05  0.05 
   0.05  0.05  
  span psi    span bar 
OR

  75 psi  or   5.25 bar  in % of span


 0.05  0.05 
   0.05  0.05  
  span psi    span bar 
In Digital Mode: ±0.075% of span.
ST 3000 Smart Pressure Transmitter 5

Parameter Description
For URV below reference point of 50 psi for model STG140 or 75 psi for model
STG14L, effect equals:
  50 psi  or   3.5 bar  in % of span
 0.025  0.05 
   0.025  0.05  
  span psi    span bar  
OR

  75 psi  or   5.25 bar  in % of span


 0.025  0.05 
   0.025  0.05  
  span psi    span bar  

Stability ±0.015% of URL per year for lifetime


* Performance specifications are based on reference conditions of 25C (77F), 10 to 55% RH, and 316 Stainless Steel barrier diaphragm.

Performance under Rated Conditions* - Models STG170 & 17L (0 to 3,000 psi)
Parameter Description
Upper Range Limit psi: 3,000 bar: 210
Minimum Span psi: 30 bar: 2.1
Turndown Ratio 100 to 1
Zero Elevation and No limit except minimum span from absolute 0 (zero) to +100% URL. Specifications
Suppression valid over this range.
Accuracy (Reference – Includes In Analog Mode: ±0.075% of calibrated span or upper range value (URV), whichever is
combined effects of linearity, greater, terminal based.
hysteresis, and repeatability) For URV calibrated below reference point (750 psi), accuracy equals:
• Accuracy includes residual error
  750 psi  or   52 bar  in % of span
after averaging successive  0.025  0.05 
   0.025  0.05  
readings.   span psi    span bar  
• For FoundationTM Fieldbus use
In Digital Mode: ±0.0625% of calibrated span or upper range value (URV), whichever
Digital Mode specifications. For
is greater, terminal based.
HART use Analog Mode
specifications. For URV calibrated below reference point (750 psi), accuracy equals:
  750 psi  or   52 bar  in % of span
 0.0125  0.05 
   0.0125  0.05  
  span psi    span bar  

Zero Temperature Effect per In Analog Mode: ±0.1125% of span.


28C (50F) For URV below reference point (500 psi), effect equals:
  500 psi  or   35 bar  in % of span
 0.0125  0.10 
   0.0125  0.10  
  span psi    span bar  
In Digital Mode: ±0.10% of span.
For URV below reference point (500 psi), effect equals:
 500 psi   35 bar 
 0.10
  or  0.10
  in % of span
 span psi   span bar 
Combined Zero and Span In Analog Mode: ±0.175% of span.
Temperature Effect per 28C For URV below reference point (500 psi), effect equals:
(50F)   500 psi  or   35 bar  in % of span
 0.075  0.10 
   0.075  0.10  
  span psi    span bar 
In Digital Mode: ±0.15% of span.
For URV below reference point (500 psi), effect equals:
  500 psi  or   35 bar  in % of span
 0.05  0.10 
   0.05  0.10  
  span psi    span bar 
Stability ±0.03% of per year
* Performance specifications are based on reference conditions of 25C (77F), 10 to 55% RH, and 316 Stainless Steel barrier diaphragm.
ST 3000 Smart Pressure Transmitter 6

Performance under Rated Conditions* - Models STG180 & 18L (0 to 6,000 psi)
Parameter Description
Upper Range Limit psi: 6,000 bar: 415
Minimum Span psi: 60 bar: 4.1
Turndown Ratio 100 to 1
Zero Elevation and No limit except minimum span from absolute 0 (zero) to +100% URL. Specifications
Suppression valid over this range.
Accuracy (Reference – Includes In Analog Mode: ±0.075% of calibrated span or upper range value (URV), whichever is
combined effects of linearity, greater, terminal based.
hysteresis, and repeatability) For URV calibrated below reference point (1,500 psi), accuracy equals:
  1500 psi    104 bar  in % of span
• Accuracy includes residual error  0.025  0.05 
  or  0.025  0.05  
after averaging successive   span psi    span bar  
readings. In Digital Mode: ±0.0625% of calibrated span or upper range value (URV), whichever
is greater, terminal based.
• For FoundationTM Fieldbus use For URV calibrated below reference point (1,000 psi), accuracy equals:
Digital Mode specifications. For
HART use Analog Mode   1500 psi    104 bar   in % of span
 0.0125  0.05 
  or  0.0125  0.05  
specifications.
  span psi    span bar  

Zero Temperature Effect per In Analog Mode: ±0.1125% of span.


28C (50F) For URV below reference point (1,000 psi), effect equals:
  1000 psi    70 bar  in % of span
 0.0125  0.10 
  or  0.0125  0.10  
  span psi    span bar 
In Digital Mode: ±0.10% of span. .
For URV below reference point (1,000 psi), effect equals:

(1000 psi
) 70 bar
(
±0.10 span psi or ±0.10 span bar in % of span )
Combined Zero and Span In Analog Mode: ±0.175% of span. For URV below reference point (1,000 psi), effect
Temperature Effect per 28C equals:
(50F)   1000 psi    70 bar  in % of span
 0.075  0.10 
  or  0.075  0.10  
  span psi    span bar 
In Digital Mode: ±0.15% of span. .
For URV below reference point (1,000 psi), effect equals:
  1000 psi    70 bar  in % of span
 0.05  0.10 
  or  0.05  0.10  
  span psi    span bar 
Stability ±0.03% of per year
* Performance specifications are based on reference conditions of 25C (77F), 10 to 55% RH, and 316 Stainless Steel barrier diaphragm.
ST 3000 Smart Pressure Transmitter 7

Performance under Rated Conditions* - Models STG19L (0 to 10,000 psi)


Parameter Description
Upper Range Limit psi: 10,000 bar: 690
Minimum Span psi: 100 bar: 7
Turndown Ratio 100 to 1
Zero Elevation and No limit except minimum span from absolute 0 (zero) to +100% URL. Specifications
Suppression valid over this range.
Accuracy (Reference – Includes In Analog Mode: ±0.075% of calibrated span or upper range value (URV), whichever
combined effects of linearity, is greater, terminal based.
hysteresis, and repeatability)
For URV calibrated below reference point (2,500 psi), accuracy equals:
• Accuracy includes residual error
after averaging successive   2500 psi    172 bar   in % of span
 0.025  0.10 
  or  0.025  0.10  
readings.
  span psi    span bar 
• For FoundationTM Fieldbus use
Digital Mode specifications. For In Digital Mode: ±0.0625% of calibrated span or upper range value (URV), whichever
HART use Analog Mode is greater, terminal based.
specifications. For URV calibrated below reference point (2,500 psi), accuracy equals:
  2500 psi    172 bar  in % of span
 0.0125  0.10 
  or  0.0125  0.10  
  span psi    span bar 
Zero Temperature Effect per In Analog Mode: ±0.1125% of span.
28C (50F) For URV below reference point (2,500 psi), effect equals:
  2500 psi    172 bar  in % of span
 0.0125  0.10 
  or  0.0125  0.10  
  span psi    span bar 
In Digital Mode: ±0.10% of span. .
For URV below reference point (2,500 psi), effect equals:

±0.10 ( 2500
span psi) or ±0.10 ( span bar) in % of span
psi 172 bar

Combined Zero and Span In Analog Mode: ±0.175% of span.


Temperature Effect per 28C For URV below reference point (2,500 psi), effect equals:
(50F)
  2500 psi    172 bar   in % of span
 0.075  0.10 
  or  0.075  0.10  
  span psi    span bar  
In Digital Mode: ±0.15% of span. .
For URV below reference point (2,500 psi), effect equals:
  2500 psi    172 bar  in % of span
 0.05  0.10 
  or  0.05  0.10  
  span psi    span bar 
Stability ±0.03% of per year
* Performance specifications are based on reference conditions of 25C (77F), 10 to 55% RH, and 316 Stainless Steel barrier diaphragm.
ST 3000 Smart Pressure Transmitter 8

Performance under Rated Conditions - General for all Models


Parameter Description
Output (two-wire) Analog 4 to 20 mA or digital communications DE mode. Options available for
FOUNDATIONTM Fieldbus and HART® protocol.
Supply Voltage Effect 0.005% of span per volt.
Damping Time Constant Adjustable from 0 to 32 seconds digital damping.
CE Conformity (Europe) 89/336/EEC, Electromagnetic Compatibility (EMC) Directive.
NAMUR NE 43 Compliance Transmitter failure information is generated when the measuring information is invalid or
Option no longer present. Failure information is transmitted as a current signal but outside the
normal 4-20 mA measurement signal level. Transmitter failure values are: ≤ 3.6 mA and
≥ 21.0 mA. The normal signal range is ≥ 3.8 mA and ≤ 20.5 mA.
SIL 2/3 Compliance SIL certified to IEC 61508 for non-redundant use in SIL 2 related Safety Systems (single
use) and for redundant (multiple) use in SIL 3 Safety Systems through
TÜV Nord Sys Tec GmbH & Co. KG under the following standards: IEC61508-1: 1998;
IEC 61508-2: 2000; IEC61508-3: 1998.
Lightning Protection Option Leakage Current: 10 microamps max. @ 42.4 VDC, 93°C
(Code “LP”) Impulse Rating: 10/20 µ sec. 5,000 Amps (50 strikes) 10,000 Amps (20 strikes)
(rise/decay) 10/1,000 µ sec. 250 Amps (1,000 strikes) 500 Amps (400 strikes)

Physical and Approval Bodies


Parameter Description
Barrier Diaphragms Material Single-Head Meter Body: 316L SS, Hastelloy® C-2762, Monel® 4003
In-Line Meter Body: 316L SS, Hastelloy® C-2762
Process Head Material Single-Head Meter Body: 316 SS4, Carbon Steel (Zinc-plated) 5, Hastelloy®, C-2762, ,
® 7
Monel 400
In-Line Meter Body: 316L SS4
Head Gaskets Teflon® is standard. Viton® and Graphite are optional – see MSG.
Meter Body Bolting Carbon Steel (Zinc plated) standard. Options include 316 SS4 bolts and nuts or NACE
(A286 SS bolts and 304 SS nuts).
Mounting Bracket Carbon Steel (Zinc-plated) or Stainless Steel angle bracket or Carbon Steel flat bracket
available.
Fill Fluid Silicone DC® 200 or CTFE (Chlorotrifluoroethylene)
Electronic Housing Epoxy-Polyester hybrid paint. Low Copper-Aluminum. Meets NEMA 4X (watertight) and
NEMA 7 (explosion proof). Stainless Steel Optional
Process Connections Single-Head Meter Body: 1/2-inch NPT, 9/16-18 Aminco, DIN (standard option)
In-Line Meter Body: 1/2-inch NPT FEM, ½ inch NPT male, 9/16 Aminco, DIN19213
Wiring Accepts up to 16 AWG (1.5 mm diameter).
Mounting Can be mounted in virtually any position using the standard mounting bracket. Bracket is
designed to mount on 2-inch (50 mm) vertical or horizontal pipe. See Figure 3 for single-
head models and Figure 4 for in-line models.
Dimensions See Figures 5 and 6.
Net Weight With Single-Head Meter Body: 7.0 pounds (3.2 Kg)
With In-Line Meter Body: 3.8 pounds (1.7 Kg)
2 ®
Hastelloy C-276 or UNS N10276
3 ®
Monel 400 or UNS N04400
4
Supplied as 316 SS or as Grade CF8M, the casting equivalent of 316 SS.
5
Carbon Steel heads are zinc-plated and not recommended for water service due to hydrogen migration. For that service, use 316
stainless steel wetted Process Heads.
6 ® ®
Hastelloy C-276 or UNS N10276. Supplied as indicated or as Grade CW12MW, the casting equivalent of Hastelloy C-276
7 ® ®
Monel 400 or UNS N04400. Supplied as indicated or as Grade M30C, the casting equivalent of Monel 400
NOTE: Pressure transmitters that are part of safety equipment for the protection of piping (systems) or vessel(s) from exceeding allowable
pressure limits, (equipment with safety functions in accordance with Pressure Equipment Directive 97/23/EC article 1, 2.1.3), require
separate examination.
ST 3000 Smart Pressure Transmitter 9

Certifications

Type of Protection Comm. Option Field Parameters Temp. Codes


Explosionproof:
Class I, Division 1, Groups A, B, C, D
locations
Dust Ignition Proof: All All T5 Ta = 93ºC
Class II, III, Division 1, Groups E, F,
G locations,
Enclosure Type 4X
Vmax = 42.4V
Imax = 225mA
Intrinsically Safe: 4-20 mA / DE Ci = 4.2nF T4 Ta = 93ºC
Li = *
Pi =1.2W
Class I, II, III, Division 1, Groups A,
B, C, D, E, F, G locations, Enclosure Vmax = 30V
Type 4X Imax = 225mA
4-20 mA / Ci = 4.2nF T4 Ta = 93ºC
Li = *
Pi =1.2W
Vmax = 32V
Imax = 120mA
Fieldbus – Entity T4 Ta = 40ºC
Ci = 4.2nF
(Not FISCO) T3 Ta = 93ºC
Li = 0
Intrinsically Safe: Pi =0.84W
Vmax = 24V
Class I, II, III, Division 1, Groups A, Imax = 250mA
B, C, D, E, F, G locations; Fieldbus – Entity T4 Ta = 40ºC
Ci = 4.2nF
(Not FISCO) T3 Ta = 93ºC
Li = 0
FM Class 1, Zone 0, AEx ia Group IIC, Pi =1.2W
Approvals
SM Enclosure Type 4X / IP 66/67 Vmax = 17.5V
Imax = 380mA
T4 Ta = 40ºC
FISCO Ci = 4.2nF
T3 Ta = 93ºC
Li = 0
Pi =5.32W
Vmax = 42.4V
Imax = 225mA
4-20 mA / DE Ci = 4.2nF T4 Ta = 93ºC
Nonincendive: Li = *
Pi =1.2W
Class I, Division 2, Groups A, B, C, D Vmax = 30V
locations, Enclosure Type 4X Imax = 225mA
4-20 mA / HART Ci = 4.2nF T4 Ta = 93ºC
Li = *
Pi =1.2W
Vmax = 32V
Nonincendive: Imax = 120mA
Fieldbus – Entity T4 Ta = 40ºC
Ci = 4.2nF
(Not FNICO) T3 Ta = 93ºC
Li = 0
Class I, Division 2, Groups A, B, C, Pi =0.84W
D;
Vmax = 24V
Imax = 250mA
Suitable for: Fieldbus – Entity T4 Ta = 40ºC
Ci = 4.2nF
Class II, Division 2, Groups F&G; (Not FNICO)
Li = 0
T3 Ta = 93ºC
Class III, Division 2; Pi =1.2W
Class I, Zone 2, Group IIC,
Vmax = 32V
Enclosure Type 4X / IP 66/67 T4 Ta = 40ºC
FNICO Ci = 4.2nF
T3 Ta = 93ºC
Li = 0
* Li = 0 except Li = 150µH when Option ME, Analog Meter, is selected.
FM ApprovalsSM is a service mark of FM Global
ST 3000 Smart Pressure Transmitter 10

Type of Protection Comm. Option Field Parameters Temp. Codes


Explosion Proof: Class I, Division
1, Groups B, C, D locations
Dust Ignition Proof: Class II, III,
All All T4 Ta = 93ºC
Division 1, Groups E, F, G
locations,
Enclosure Type 4X
Vmax = 42V
Imax = 225mA
4-20 mA / DE Ci = 4.2nF T4 Ta = 93ºC
Li = *
Pi =1.2W
Intrinsically Safe: Vmax = 42V
Imax = 225mA
Class I, II, III, Division 1, Groups A, 4-20 mA / HART Ci = 4.2nF T4 Ta = 93ºC
B, C, D, E, F, G locations, Li = *
Enclosure Type 4X Pi =1.2W
Vmax = 24V
Canadian Fieldbus – Entity
Imax = 250mA
T4 Ta = 40ºC
Standards Ci = 4.2nF
(Not FISCO) T3 Ta = 93ºC
Association Li = 0
Pi =1.2W
(CSA)
Vmax = 42.4V
Imax = 225mA
4-20 mA / DE Ci = 4.2nF T4 Ta = 93ºC
Li = *
Pi =1.2W
Nonincendive: Vmax = 30V
Imax = 225mA
4-20 mA / HART Ci = 4.2nF T4 Ta = 93ºC
Class I, Division 2, Groups A, B, C,
Li = *
D locations, Enclosure Type 4X Pi =1.2W
Vmax = 24V
Imax = 250mA
Fieldbus – Entity T4 Ta = 40ºC
Ci = 4.2nF
(Not FNICO) T3 Ta = 93ºC
Li = 0
Pi =1.2W
All ST 3000 models except STG19L, STG99L, STG170 and STG180
Canadian Registration Number
have been registered in all provinces and territories in Canada and are
(CRN): marked CRN: 0F8914.5C.
ST 3000 Smart Pressure Transmitter 11

Type of Protection Comm. Option Field Parameters Temp. Codes


Flameproof, Zone 1:
T5 Ta = –50 to 93ºC
All All
T6 Ta = –50 to 78ºC
Ex d IIC, Enclosure IP 66/67
Ui = 30V
Ii = 100mA T4 Ta = –50 to 93ºC
4-20 mA / DE Ci = 4.2nF T5 Ta = –50 to 85ºC
IECEx Li = * T6 Ta = –50 to 70ºC
International Pi =1.2W
Electrotechnical Ui = 30V
Commission Intrinsically Safe, Zone 0/1: Ii = 100mA T4 Ta = –50 to 93ºC
(LCIE) 4-20 mA / HART Ci = 4.2nF T5 Ta = –50 to 63ºC
Ex ia IIC, Enclosure IP 66/67 Li = * T6 Ta = –50 to 48ºC
Pi =1.2W
Ui = 24V
Ii = 250mA
Fieldbus T3 Ta = –50 to 93ºC
Ci = 4.2nF
(Not FISCO) T4 Ta = –50 to 40ºC
Li = 0
Pi =1.2W
 Li = 0 except Li = 150µH when Option ME, Analog Meter, is selected.

Type of Protection Comm. Option Field Temp. Codes


Parameters
SAEx Flameproof, Zone 1: All All
(South Africa) Ex d IIC, Enclosure IP 66/67 T5 Ta = –50 to 93ºC
T6 Ta = –50 to 78ºC
Intrinsically Safe, Zone 0/1:
Ex ia IIC, Enclosure IP 66/67 4-20 mA / DE Ui = 30V T4 Ta = –50 to 93ºC
Ii = 100mA T5 Ta = –50 to 85ºC
Ci = 4.2nF T6 Ta = –50 to 70ºC
Li = *
Pi =1.2W

4-20 mA / HART Ui = 30V T4 Ta = –50 to 93ºC


Ii = 100mA T5 Ta = –50 to 63ºC
Ci = 4.2nF T6 Ta = –50 to 48ºC
Li = *
Pi =1.2W

Fieldbus Ui = 24V T3 Ta = –50 to 93ºC


(Not FISCO) Ii = 250mA T4 Ta = –50 to 40ºC
Ci = 4.2nF
Li = 0
Pi =1.2W
Multiple Marking:
4-20 mA / DE Ui = 30V T4 Ta = –50 to 93ºC
Flameproof, Zone 1: Ii = 100mA T5 Ta = –50 to 85ºC
Ci = 4.2nF T6 Ta = –50 to 70ºC
Ex d IIC, Enclosure IP 66/67
Li = *
Pi =1.2W
Intrinsically Safe, Zone 0/1:
Ex ia IIC, Enclosure IP 66/67 4-20 mA / HART Ui = 30V T4 Ta = –50 to 93ºC
Ii = 100mA T5 Ta = –50 to 63ºC
NOTE: The user must determine the Ci = 4.2nF T6 Ta = –50 to 48ºC
type of protection required for Li = *
installation of the equipment. The user Pi =1.2W
shall then check the box [√] adjacent
to the type of protection used on the Fieldbus Ui = 24V T3 Ta = –50 to 93ºC
equipment certification nameplate. (Not FISCO) Ii = 250mA T4 Ta = –50 to 40ºC
Once a type of protection has been Ci = 4.2nF
checked on the nameplate, Li = 0
subsequently the equipment shall not Pi =1.2W
be reinstalled using any of the other
certification types.
* Li = 0 except Li = 150µH when Option ME, Analog Meter, is selected.
ST 3000 Smart Pressure Transmitter 12

Type of Protection Comm. Field Temp. Codes


Option Parameters
Flameproof, Zone 0:
A20 IP6X T95ºC Ta = 93ºC
, Ex tD All All
or T80ºC Ta = 78ºC
Enclosure IP 66/67
Flameproof, Zone 1: T5 Ta = –50 to +93ºC
T6 Ta = –50 to +78ºC,
, Ex d IIC, Ex tD All All
A21 IP6X T95ºC Ta = 93ºC
Enclosure IP 66/67 or T80ºC Ta = 78ºC
Ui = 30V
Ii = 100mA T4 Ta = –50 to 93ºC
4-20 mA / DE Ci = 4.2nF T5 Ta = –50 to 85ºC
Li = * T6 Ta = –50 to 70ºC
Pi =1.2W
Intrinsically Safe, Zone 0/1:
Ui = 30V
, Ex ia IIC, Ii = 100mA T4 Ta = –50 to 93ºC
4-20 mA / HART Ci = 4.2nF T5 Ta = –50 to 63ºC
Li = * T6 Ta = –50 to 48ºC
Enclosure IP 66/67 Pi =1.2W
Ui = 24V
Ii = 250mA
Fieldbus T3 Ta = –50 to 93ºC
Ci = 4.2nF
(Not FISCO) T4 Ta = –50 to 40ºC
Li = 0
Pi =1.2W
Ui = 30V
Ii = 100mA T4 Ta = –50 to 93ºC
4-20 mA / DE Ci = 4.2nF T5 Ta = –50 to 85ºC
Li = * T6 Ta = –50 to 70ºC
Pi =1.2W
Non-Sparking, Zone 2: Ui = 30V
ATEX Ii = 100mA T4 Ta = –50 to 93ºC
(LCIE) 4-20 mA / HART Ci = 4.2nF T5 Ta = –50 to 63ºC
,Ex nA IIC (Honeywell), Li = * T6 Ta = –50 to 48ºC
Enclosure IP 66/67 Pi =1.2W
Ui = 24V
Ii = 250mA
Fieldbus T3 Ta = –50 to 93ºC
Ci = 4.2nF
(Not FNICO) T4 Ta = –50 to 40ºC
Li = 0
Pi =1.2W
Multiple Marking: Ui = 30V
Ii = 100mA T4 Ta = –50 to 93ºC
Flameproof, Zone 1: 4-20 mA / DE Ci = 4.2nF T5 Ta = –50 to 85ºC
Li = * T6 Ta = –50 to 70ºC
, Ex d IIC
Pi =1.2W

Intrinsically Safe, Zone 0/1: Ui = 30V


Ii = 100mA T4 Ta = –50 to 93ºC
, Ex ia IIC
4-20 mA / HART Ci = 4.2nF T5 Ta = –50 to 63ºC
Li = * T6 Ta = –50 to 48ºC
Non-Sparking, Zone 2: Pi =1.2W
, Ex nA IIC

NOTE: The user must determine the


type of protection required for
installation of the equipment. The user Ui = 24V
shall then check the box [ √ ] adjacent Fieldbus Ii = 250mA
T3 Ta = –50 to 93ºC
to the type of protection used on the (Not Ci = 4.2nF
T4 Ta = –50 to 40ºC
equipment certification nameplate. FISCO/FNICO) Li = 0
Once a type of protection has been Pi =1.2W
checked on the nameplate,
subsequently the equipment shall not
be reinstalled using any of the other
certification types.
* Li = 0 except Li = 150µH when Option ME, Analog Meter, is selected.
ST 3000 Smart Pressure Transmitter 13

Type of Protection Comm. Option Field Temp. Codes


Parameters
Flameproof, Zone 1:
T5 Ta = –50 to 93ºC
All All
BR-Ex d IIC T6 Ta = –50 to 78ºC
Enclosure IP 66/67
Ui = 30V
Ii = 100mA T4 Ta = –50 to 93ºC
4-20 mA / DE Ci = 4.2nF T5 Ta = –50 to 85ºC
INMETRO Li = * T6 Ta = –50 to 70ºC
(CERTUSP) Pi =1.2W
Brazil Intrinsically Safe, Zone 0/1: Ui = 30V
Ii = 100mA T4 Ta = –50 to 93ºC
4-20 mA / HART Ci = 4.2nF T5 Ta = –50 to 63ºC
BR-Ex ia IIC
Li = * T6 Ta = –50 to 48ºC
Enclosure IP 66/67 Pi =1.2W
Ui = 24V
Ii = 250mA
Fieldbus T3 Ta = –50 to 93ºC
Ci = 4.2nF
(Not FISCO) T4 Ta = –50 to 40ºC
Li = 0
Pi =1.2W
* Li = 0 except Li = 150µH when Option ME, Analog Meter, is selected.

This certificate defines the certifications covered for the ST 3000 Pressure Transmitter family of
products, including the SMV 3000 Smart Multivariable Transmitter. It represents the compilation
of the five certificates Honeywell currently has covering the certification of these products into
marine applications.
For ST 3000 Smart Pressure Transmitter and SMV 3000 Smart Multivarible Transmitter
ST 3000 Pressure American Bureau of Shipping (ABS) - 2009 Steel Vessel Rules 1-1-4/3.7, 4-6-2/5.15, 4-8-3/13 &
Transmitter Marine 13.5, 4-8-4/27.5.1, 4-9-7/13. Certificate number: 04-HS417416-PDA
Certificate
Bureau Veritas (BV) - Product Code: 389:1H. Certificate number: 12660/B0 BV
(MT Option)
Det Norske Veritas (DNV) - Location Classes: Temperature D, Humidity B, Vibration A, EMC B,
Enclosure C. For salt spray exposure; enclosure of 316 SST or 2-part epoxy protection with 316
SST bolts to be applied. Certificate number: A-11476
Korean Register of Shipping (KR) - Certificate number: LOX17743-AE001
Lloyd's Register (LR) - Certificate number: 02/60001(E1) & (E2)
ST 3000 Smart Pressure Transmitter 14

The ST 3000 Smart Pressure Transmitters are in conformity with the essential requirements of the
Pressure Equipment Directive.

Honeywell ST 3000 Smart Pressure Transmitters are designed and manufactured in accordance
with the applicable portions of Annex I, Essential Safety Requirements, and sound engineering
practices. These transmitters have no pressurized internal volume, or have a pressurized internal
volume rated less than 200 bar (2,900 psig), and/or have a maximum volume of less than 0.1 liter
(Article 3, 1.1.(a) first indent, Group 1 fluids). Therefore, these transmitters are not subject to the
essential requirements of the directive 97/23/EC (PED, Annex I) and shall not have the CE mark
European applied.
Pressure
Equipment
For transmitters rated > 200 bar (2,900 psig) < 1,000 bar (14,500 psig) Honeywell maintains a
Directive (PED)
technical file in accordance with Annex III, Module A, (internal production control) when the CE
(97/23/EC)
mark is required. Transmitter Attachments: Diaphragm Seals, Process Flanges and Manifolds
comply with Sound Engineering Practice.

NOTE: Pressure transmitters that are part of safety equipment for the protection of piping (systems)
or vessel(s) from exceeding allowable pressure limits, (equipment with safety functions in
accordance with Pressure Equipment Directive 97/23/EC article 1, 2.1.3), require separate
examination.
A formal statement from TÜV Industry Service Group of TÜV America, Inc., a division of TÜV
Süddeutschland, a Notified Body regarding the Pressure Equipment Directive, can be found at
www.honeywell.com. A hard copy may be obtained by contacting a Honeywell representative.

Electro Magnetic Compatibility (EMC) (2004/108/EC)


CE Mark All Models: EN 50081-1: 1992; EN 50082-2:1995; EN 61326-1:1997 + A1, A2, and A3 – Industrial
Locations

Dual Seal Dual Seal Certification based on ANSI/NFPA 70-202 and ANSI/ISA 12.27.01 requirements without
Certification the use of additional seal protection elements.

Recommended
Frequency of Honeywell recommends verifying the calibration of these devices once every four years.
Calibration

Approved Honeywell Process Solutions - York, PA USA


Manufacturing Honeywell (Tianjin) Limited – Tianjin, P.R. China
Locations Honeywell Automation India Ltd. – Pune 411013 India

TM
Foundation Fieldbus is a trademark of the Fieldbus Foundation.
®
Viton is a registered trademark of DuPont
®
HART is a registered trademark of HART Communications Foundation.
®
Teflon is a registered trademark of DuPont.
®
Hastelloy C-276 is a registered trademark of Haynes International.
®
DC 200 is a registered trademark of Dow Corning.
®
Monel 400 is a registered trademark of Special Metals Corporation.
SM
FM Approvals is a service mark of FM Global
ST 3000 and Experion are registered trademarks of Honeywell International Inc.

ST 3000 Smart Pressure Transmitter 15

Mounting

24267

Figure 3 - Examples of typical mounting positions for single-head models STG140, STG170, and STG180.

24268

Figure 4 - Examples of typical mounting positions for in-line models STG14L, STG17L, STG18L, and STG19L.
Note that a mounting bracket is not required for in-line models.
ST 3000 Smart Pressure Transmitter 16

Reference Dimensions

millimeters
inches

With 82.9 With


94.9
Smart 3.26 Analog
3.74
meter meter

Removal 53.1 65.1


Clearance 2.09 2.56
for All Caps Without Without 135 3.6
45.7 meter meter 5.32 0.14
1.8
Plug

55.3
2.18
Optional
meters
23.5
.925
1/2" NPT

Optional
Rotational
external
lock
252.8 / 262.1* ground
9.95 / 10.32
162 / 171.3*
6.38 / 6.74

6
0.24
71.1
2.80
SQ. 21.2
0.83
1/2" NPT
Pressure
Connection Mounting Holes
M8 x 1.25 (2)

50
1.97
53.6
2.11
74.4
2.93
24269
*Dimensions vary due to slight differences in electronics housing designs.

Figure 5 - Typical mounting dimensions for single-head models STG140, STG170, and STG180 for reference.
ST 3000 Smart Pressure Transmitter 17

Reference Dimensions

millimeters
inches

With With
Smart 82.9 94.9 Analog
meter 3.26 3.74 meter

Removal 53.1 65.1


Clearance 2.09 2.56
for All Caps
Without Without 135 3.6
45.7 meter meter 5.32 0.14
1.8
Plug

55.3
2.18
Optional
meters
23.5
.925
1/2"
NPT

Optional 158 / 183*


external 6.22 / 7.20 Rotational
ground lock
213.3 / 238.3*
8.40 / 9.38

Other Connectors
1/2" NPT ½” NPT male DIN19213
Pressure
38.1
44.5 Connection
1.5
1.75 or
9/16 Aminco
38.1 Pressure Connection
1.5
24270
*Dimensions vary due to slight differences in electronics housing designs.

Bottom view of DIN

Figure 6 - Typical mounting dimensions for in-line models STG14L, STG17L, STG18L, and STG19L for reference.
ST 3000 Smart Pressure Transmitter 18

Options
 High Accuracy (Option HA)  Indicator Configuration (Option CI)
Extends applicable ST 3000 S100 models to Provides custom configuration of Smart Meters.
±0.0375% reference accuracy (analog).  NAMUR NE43 Compliance (Option NE)
The mounting bracket is available in either zinc- This option provides software the meets the
plated carbon steel or stainless steel. NAMUR NE43 requirements for failsafe
 Mounting Bracket (Options MB, MX, SB, SX, FB) software. Transmitter failure information is
The angle mounting bracket is available in either generated when the measuring information is no
zinc-plated carbon steel or stainless steel and is longer valid.
suitable for horizontal or vertical mounting on a Transmitter failure values are:
two inch (50 millimeter) pipe, as well as wall ≤ 3.6 mA and ≥ 21.0 mA. The normal ST 3000
mounting. An optional flat mounting bracket is ranges are ≤ 3.8 mA and
also available in carbon steel for two inch (50 ≥ 20.5 mA.
millimeter) pipe mounting.  Lightning Protection (Option LP)
 Indicating Meter (Options ME and SM) A terminal block is available with circuitry that
Two integral meter options are available. An protects the transmitter from transient surges
analog meter (option ME) is available with a 0 to induced by nearby lightning strikes
100% linear scale. The Smart Meter (option SM)  Tagging (Option TG)
provides an LCD display for both analog and Up to 30 characters can be added on the
digital output and can be configured to display stainless steel nameplate mounted on the
pressure in pre-selected engineering units. transmitter’s electronics housing at no extra
 HART® Protocol Compatibility cost. Note that a separate nameplate on the
(Options HC and H6) meter body contains the serial number and
Optional electronics modules for the ST 3000 body-related data. A stainless steel wired on tag
provides HART Protocol compatibility in either with additional data of up to 4 lines of 28
HART 5.x or 6.x formats. Transmitters with a characters is also available. The number of
HART Option are compatible with any HART characters for tagging includes spaces.
enabled system that provides 5.x or 6.x format  Transmitter Configuration (Option TC)
support. The factory can configure the transmitter
 FOUNDATION Fieldbus (Option FF) linear/square root extraction, damping time,
Equips transmitter with FF protocol for use in LRV, URV and mode (analog/digital) and enter
31.25 kbit/s FF networks. See document 34-ST- an ID tag of up to eight characters and
03-72 for additional information on ST 3000 scratchpad information as specified.
Fieldbus transmitters.  Custom Calibration and ID in Memory (Option CC)
 SIL2/SIL3 Certification (Option SL) The factory can calibrate any range within the
This ST 3000 product is available for use with scope of the transmitter’s range and enter an ID
safety systems. With the SL option, we are fully tag of up to eight characters in the transmitter’s
certified to SIL 2 capability for single transmitters memory.
and SIL 3 capability for multiple transmitter use  Lifetime Warranty (Option WL)
through TÜV Nord Sys Tec GmbH & Co. KG. Extends limited 1-year warranty policy to 15
We are in compliance with the following SIL years for ST 3000 S100 pressure transmitters.
standards: See Honeywell Terms and Conditions.
 IEC 61508-1: 1998

 IEC 61508-2: 2000

 IEC 61508-3: 1998


ST 3000 Smart Pressure Transmitter 19

Sales and Service


For application assistance, current specifications, pricing, or name of the nearest Authorized Distributor, contact one of the offices below.

Asia Pacific Global New Zealand Denmark Spain AFRICA


Honeywell Limited Honeywell A/S Honeywell S.A. Mediterranean & African
Technical Support Phone: +(64-9) 623-5050 Phone: +(45) 39 55 55 55 Phone: +34 (0)91313 61 00
Field Instruments Distributors
Fax: +(64-9) 623-5060 FAX: +(45) 39 55 55 58 FAX: +34 (0)91313 61 30 Honeywell SpA
Phone: +65 6580 3156 Toll Free (0800) 202-088
Fax: +65 6445-3033 Phone: +39 (02) 250 10 604
Finland Sweden FAX: +39 (02) 250 10 659
Singapore Honeywell OY Honeywell AB
Australia Honeywell Pte Ltd. Phone: +358 (0)20752 2753 Phone: +(46) 8 775 55 00
Honeywell Limited South Africa (Republic of)
Phone: +(65) 6580 3278 FAX: +358 (0) 20752 2751 FAX: +(46) 8 775 56 00 and sub saharan
Phone: +(61) 7-3846 1255 Fax: +(65) 6445-3033
FAX: +(61) 7-3840 6481 Honeywell Southern Africa
France Switzerland Honeywell S.A. Pty. Ltd.
Toll Free 1300-36-39-36 South Korea Honeywell SA Honeywell AG
Toll Free Fax: Phone: +27 11 6958000
Honeywell Korea Co Ltd Phone: +33 (0)1 60198075 Phone: +41 18552448 FAX +27 118051504
1300-36-04-70 Phone: +(822) 799 6114 FAX: +33 (0)1 60198201 FAX: +(41) 1 855 24 45
Fax: +(822) 792 9015
China – PRC - Beijing Germany Turkey NORTH AMERICA
Honeywell China Inc. Thailand Honeywell AG Honeywell Turkey A.S. Canada
Phone: +(86-10) 8458- Honeywell Systems Phone: +49 (69)8064-299 Phone: +90 216 578 71 00 Honeywell LTD
3280 (Thailand) Ltd. FAX: +49 (69)806497336 FAX: +90 216 575 66 35 Phone: 1-800-737-3360
Fax: +(86-10) 8458-4650 Phone: +(662) 693-3099 FAX: 1-800-565-4130
FAX: +(662) 693-3089 Hungary Ukraine
China – PRC - Shanghai Honeywell Kft. Honeywell USA
Honeywell China Inc. Taiwan R.O.C. Phone: +36-1-451 4300 Tel: +380-44- 351-15-50 Honeywell Process
Phone: (86-21) 5257-4568 Honeywell Taiwan Ltd. FAX: +36-1-451 4343 Fax: +380-44- 351-15-51 Solutions,
Fax: (86-21) 6237-2826 Phone: +(886-2) 2245- Phone: 1-800-423-9883
1000 Italy United Kingdom Or 1-800-343-0228
China – PRC - Chengdu FAX: +(886-2) 2245-3243 Honeywell S.p.A. Honeywell Control Systems Email: ask-
Honeywell China Inc. Phone:+390292146307 Ltd. [email protected]
Phone: +(86-28) 6613- SE Asia Countries FAX: +39 0292146377 Phone: +44 (0)1344 655251
5078 see Honeywell Pte Ltd FAX: +44 (0) 1344 655554
Fax: +(86-28) 8678-7061 (Singapore) The Netherlands SOUTH AMERICA
for: Philippines, Pakistan, Honeywell B.V. MIDDLE EAST Argentina
China – PRC - Xi’an Phone: +31 (0) 20 5656200
Honeywell China Ltd - Cambodia, Guam, Laos, Abu Dhabi U A E Honeywell S.A.I.C.
Myanmar, Vietnam, FAX: +31 (0) 20 5656210 Middle East Headquarters Phone: +(54-11) 4383-3637
Xi’an.
Phone: +(86-29) 8833- East Timor Honeywell Middle East Ltd. FAX: +(54-11) 4325-6470
Norway
7490 Honeywell A/S Phone: +971 2 4041246
SE Asia Countries FAX: +971 2 4432536 Brazil
Fax: +(86-29) 8833-7489 Phone: (45) 39 55 55 55 Honeywell do Brasil & Cia
see Honeywell
China – PRC - Shenzhen- Automation India Ltd for: Sultanate of Oman Phone: +(55-11) 7266-1900
Poland FAX: +(55-11) 7266-1905
Honeywell China Inc. Bangladesh Honeywell Sp. zo.o Honeywell & Co Oman LLC
Phone: +(86) 755-2518- Nepal Phone: +48-22-6060900 Phone: +968 24 701153/
Sri Lanka Ext.33 Chile
1226 FAX: +48-22-6060901 Honeywell Chile, S.A.
Fax: +(86) 755-2518-1221 FAX +968 24 787351
EUROPE Phone: +(56-2) 233-0688
Portugal FAX: +(56-2) 231-6679
Indonesia Austria Honeywell Portugal Lda Saudia Arabia
PT Honeywell Indonesia Honeywell Austria GmbH Phone: +351 21 424 5000 Honeywell Turki Arabia Ltd
Jubail Office Mexico
Phone: +(62) 21-535-8833 Phone: +43 (316)400123 FAX: +351 21 424 50 99 Honeywell S.A. de C.V.
FAX: +(62) 21-5367 1008 FAX: +43 (316)40017 Phone: +966-3-341-0140
Fax: +966-3-341-0216 Phone: +(52) 55 5259-1966
Romania FAX: +(52) 55 5570-2985
Honeywell Automation Belgium Honeywell Bucharest Honeywell - ATCO
India Ltd. Honeywell SA/NV Phone: +40 (0) 21 2316437 Dammam Office
Phone: 0096638304584 Puerto Rico
Honeywell Ltd. Phone:+32 (0)2728 24 07 FAX: +40 (0) 21 2316439 Honeywell Inc.
Phone:+(91) 6603-9400 FAX: +32 (0)2728 22 45 Fax: 0096638338059
Phone: +(809) 792-7075
Fax: +(91) 6603-9600 Russian Federation (RF), FAX: +(809) 792-0053
Bulgaria Honeywell Field Solutions Kuwait
Japan Honeywell EOOD Kievskaya str., 7, Honeywell Kuwait KSC
Phone: +965 242 1327 to 30 Trinidad
Honeywell Inc. Phone: +(359) 2 40 20 Moscow 121059, Russia Honeywell Inc.
Phone: +(81) 3 6730 7197 900 Phone +7 (495) 796 98 60 Fax: +965 242 8315
And Phone: +(868) 624-3964
Fax: +(81) 3 6730 7228 FAX: +(359) 2 40 20 990 Fax +7 (495) 797 99 64 FAX: +(868) 624-3969
Phone: +965 326
Malaysia Czech Republic Slovak Republic 2934/1821Fax: +965 326 Venezuela
Honeywell Engineering Honeywell spol. s.r.o. Honeywell s.r.o. 1714 Honeywell CA
Sdn Bhd Phone:+420 242 442 232 Phone: +421-2-58247 410 Phone: +(58-2) 238-0211
Phone: +(603) 7958-4788 FAX: +420 242 442 131 FAX: +421-2-58247 415 FAX: +(58-2) 238-3391
Fax: +(603) 7958-8922
ST 3000 Smart Pressure Transmitter 20

Model Selection Guides are subject to change and are inserted into the specifications as guidance only.
Prior to specifying or ordering a model check for the latest revision Model Selection Guides which are published at:
http://hpsweb.honeywell.com/Cultures/en-US/Products/Instrumentation/ProductModelSelectionGuides/default.htm
Model Selection Guide
34-ST-16U-03
Issue 57
Page 1 of 4

ST 3000 Smart Transmitter Model Selection Guide


Gage Pressure (GP) &
Absolute Pressure (AP)
Series 100

Instructions
● Select the desired Key Number. The arrow to the right marks the selection available.
● Make one selection from each Table (I, II and IV) using the column below the proper arrow.
● Select as many Table III options as desired plus a required communications option selection.
● A (●) denotes unrestricted availability. A letter denotes restricted availability.
● Restrictions follow Table IV.
Key Number I II III (Optional) IV
______ - ___ - 00000 - _ _, _ _ + XXXX

KEY NUMBER
Design Span Selection Availability
0-5 to 0-500 psi / 0-0.34 to 0-35 bar STG140
Single
0-30 to 0-3,000 psi / 0-2.1 to 0-210 bar STG170
Head
0-60 to 0-6,000 psi / 0-4.1 to 0-420 bar STG180
Gage
0-5 to 0-500 psi / 0-0.34 to 0-35 bar STG14L
Pressure
0-30 to 0-3,000 psi / 0-2.1 to 0-210 bar STG17L
In-Line
0-60 to 0-6,000 psi / 0-4.1 to 0-420 bar STG18L
0-100 to 0-10,000 psi / 0-7 to 0-690 bar STG19L
Single 0-50 to 0-780 mm HgA / 0-67 to 0-1,040 mbarA STA122
Head 0-5 to 0-500 psi/0-0.34 to 0-35 bar absolute STA140
Absolute
0-50 to 0-780 mm HgA / 0-67 to 0-1,040 mbarA STA12L
Pressure
In-Line 0-5 to 0-500 psia / 0-0.34 to 0-35 barA STA14L
0-30 to 0-3,000 psia / 0-2.1 to 0-210 barA STA17L

Base STG and STA models no longer include a default communications option. All units now require the
Important Note:
selection of a communication option from Table III (AN, DE, HC, H6 or FF).

TABLE I - METER BODY


Wetted Process Heads / Vent/Drain
Barrier Diaphragms Selection
Bonnet Valves
1
Carbon Steel - 316L SS A__ ● ● ● ● ●
1 ® 3
Carbon Steel - Hastelloy C-276 B__ ● ● ● ● ●
1 ®4
Carbon Steel - Monel 400 C__ 19 19 19 19
5
316 SS - 316L SS E__ ● ● ● ● ●
Materials of * - 316L SS E__ ● ● ● ●
5 ® 3
Construction 316 SS - Hastelloy C-276 F__ ● ● ● ● ●
® 3
* - Hastelloy C-276 F__ ● ● ● ●
5 ®4
316 SS - Monel 400 G__ 19 19 19 19
® 3, 6 ® 3
Hastelloy C-276 - Hastelloy C-276 J__ ● ● ● ● ●
® 7 ®4
Monel 400 - Monel 400 L__ 19 19 19 19
® 8
Silicone DC 200 _1_ ● ● ● ● ● ● ● ● ●
Fill Fluid CTFE (Halocarbon 6.3) _2_ ● ● ● ● ● ● ●
CTFE (MO-10) _4_ ● ●
9/16" - 18 Aminco __A ● ● ● ● ● ● ●
Process Connection 1/2 NPT (female) __G ● ● ● ● ● ● ● ● ●
Configuration 1/2 NPT (male) __H ● ● ● ●
DIN 19213 __D ● ● ●
1
Carbon Steel heads are zinc-plated and not recommended for water service due to hydrogen migration. For that service, use
316 stainless steel Wetted Process Heads.
3
Hastelloy® C-276 or UNS N10276
4
Monel 400® or UNS N04400
5
Supplied as 316 SS or as Grade CF8M, the casting equivalent of 316 SS.
6
Supplied as indicated or as Grade CW12MW, the casting equivalent of Hastelloy® C-276
7
Supplied as indicated or as Grade M30C, the casting equivalent of Monel 400®
8
Use DC®704 option when the STA122 or STA12L will be operating below 50mm HgA, see Fig. 2 in Specification 34-ST-03-65.
* STG1_L has 316L SS process interface.
ST 3000 Smart Pressure Transmitter 21

34-ST-16U-03
Issue 57
Page 2 of 4 STG180 STG14L
STG170 STA14L/17L, STG17L/18L
STG140 STG19L
STA140 STA12L
STA122
TABLE II Selection
No Selection 00000 ● ● ● ● ● ● ● ● ●

TABLE III - OPTIONS


Communication Options (Must choose a communications option)
Analog only (can be configured using appropriate Honeywell DE tool) AN ● ● ● ● ● ● ● ● ●
DE Protocol communications DE ● ● ● ● ● ● ● ● ●
®
HART 5.x Protocol Compatible Electronics HC ● ● ● ● ● ● ● ● ● b
®
HART 6.x Protocol Compatible Electronics H6 ● ● ● ● ● ● ● ● ●
FOUNDATIONTM Fieldbus Communications FF r r r r r r r r r
Indicating Meter Options
Analog Meter (0-100 Even 0-10 Square Root) ME ● ● ● ● ● ● ● ● ●
b
Smart Meter SM ● ● ● ● ● ● ● ● ●
Custom Configuration of Smart Meter CI e e e e e e e e e
Local Zero & Span ZS m m m m m m
b
Local Zero LZ x x x x x x
Transmitter Housing & Electronics Options
No housing conduit plugs come standard with the ST 3000.
For certain approval codes, you must select select a certified couduit plug
from below and it will come packaged in the box with your transmitter.
5
316 SS Electronics Housing - (with M20 Conduit Connections) SH n n n n n n n n n
5
316 SS Electronics Housing - (with M20 to 1/2 NPT 316 SS Conduit b
A3 i i i i i i i i i
Adapter for use with FM and CSA Approval codes)
1/2 NPT to M20 316 SS Conduit Adaptor (Certified ATEX, CSA & IECEx) A1 n n n n n n n n n
1/2 NPT to 3/4 NPT 316 SS Conduit Adaptor (Certified ATEX, CSA & IECEx) A2 ● ● ● ● ● ● ● ● ●
M20 Male to 1/2 NPT Female 316 SS Conduit Adaptor (Certified ATEX, CSA
A4 ● ● ● ● ● ● ● ● ●
& IECEx)
1/2 NPT Zinc-plated Certified Conduit Plug (ATEX, CSA & IECEx) A5 ● ● ● ● ● ● ● ● ●
1/2 NPT 316 SS Certified Conduit Plug (ATEX, CSA & IECEx) A6 ● ● ● ● ● ● ● ● ●
M20 316 SS Certified Conduit Plug (ATEX, CSA & IECEx) A7 ● ● ● ● ● ● ● ● ●
1/2 NPT Non-certified Conduit plug (Zinc-plated carbon steel, general use) A8 ● ● ● ● ● ● ● ● ●
NAMUR Failsafe Software NE 15 15 15 15 15 15 15 15 15
SIL 2 - TÜV Certified transmitter (requires HC/H6 and WP options) SL p p p p p p p p p
Lightning Protection LP ● ● ● ● ● ● ● ● ●
Custom Calibration and I.D. in Memory CC ● ● ● ● ● ● ● ● ●
Transmitter Configuration - (non-Fieldbus) TC 15 15 15 15 15 15 15 15 15
b
Transmitter Configuration - (Fieldbus) FC 21 21 21 21 21 21 21 21 21
Write Protection (Delivered in "ON" position) WP ● ● ● ● ● ● ● ● ●
b
Write Protection (Delivered in "OFF" position) WX g g g g g g g g g
Stainless Steel Customer Wired-On Tag (4 lines, 26 characters per line,
TG ● ● ● ● ● ● ● ● ●
customer supplied information)
Stainless Steel Customer Wired-On Tag (blank) TB ● ● ● ● ● ● ● ● ●
High Accuracy HA d d
Meter Body Options
A286 SS (NACE) Bolts and 304 SS (NACE) Nuts for Head CR ● ● ● ● ●
b
316 SS Bolts and 316 SS Nuts for Proces Heads SS f f f
Modified DIN Process Heads - 316 SS DN w w w w w
® ®
Viton Process Head Gasket (Teflon is standard) VT z z z
Graphite Process Head Gasket GF ● ● ● b
®9 ®
Teflon Process Head Gasket (Viton is standard) TF ● ●
Transmitter Mounting Bracket Options
Angle Mounting Bracket - Carbon Steel MB ● ● ● ● ● ● ● ● ●
Marine Approved Angle Mounting Bracket - Carbon Steel MX ● ● ● ● ● ● ● ● ●
Angle Mounting Bracket - 304 SS SB ● ● ● ● ● ● ● ● ● b
Marine Approved Angle Mounting Bracket - 304 SS SX ● ● ● ● ● ● ● ● ●
Flat Mounting Bracket - Carbon Steel FB ● ● ● ● ● ● ● ● ●
Services/Certificates/Marine Type Approval Options
User's Manual Paper Copy (Standard, HC, H6 or FF ships accordingly) UM ● ● ● ● ● ● ● ● ●
Clean Transmitter for Oxygen or Chlorine Service with Certificate (50039190) 0X h h h h h h h h h
Over-Pressure Leak Test with Certificate (F3392) TP ● ● ● ● ● ● ● ● ●
Calibration Test Report and Certificate of Conformance (F3399) F1 ● ● ● ● ● ● ● ● ●
b
Certificate of Conformance (F3391) F3 ● ● ● ● ● ● ● ● ●
Certificate of Origin (F0195) F5 ● ● ● ● ● ● ● ● ●
SIL Certificate (SIL 2/3) (FC33337) FE 22 22 22 22 22 22 22 22 22
NACE Certificate (Process-Wetted & Non-Process Wetted) (FC33339) F7 o o o o o ● ● ● ●
b
NACE Certificate (Process-Wetted) (FC33338) FG ● ● ● ● ● ● ● ● ●
Material Traceability Certification per EN 10204 3.1 (FC33341) FX ● ● ● ● ● ● ● ● ●
Marine Type Approvals (DNV, ABS, BV, KR & LR) (FC33340) MT 2 2 2 2 2 2 2 2 2
Table III continued next page
5
Supplied as 316 SS or as Grade CF8M, the casting equivalent of 316 SS.
8
Viton® or Fluorocarbon Elastomer
9
Teflon® or PTFE
ST 3000 Smart Pressure Transmitter 22

34-ST-16U-03
Issue 57
Page 3 of 4

STG180 STG14L
STG170 STA14L/17L, STG17L/18L
STG140 STG19L
STA140 STA12L
TABLE III - OPTIONS (continued) STA122
Warranty Options Selection
Additional Warranty - 1 year W1 ● ● ● ● ● ● ● ● ●
Additional Warranty - 2 years W2 ● ● ● ● ● ● ● ● ●
Additional Warranty - 3 years W3 ● ● ● ● ● ● ● ● ● b
Additional Warranty - 4 years W4 ● ● ● ● ● ● ● ● ●
Lifetime Warranty - 15 years WL ● ● ● ● ● ● ● ● ●

Approval
Approval Type Location or Classification Selection
Body
No hazardous location approvals 9X ● ● ● ● ● ● ● ● ●
Explosion Proof Class I, Div. 1, Groups A,B,C,D
FM Dust-Ignitionproof Class II, III Div. 1, Groups E,F,G
SM 1C ● ● ● ● ● ● ● ● ●
Approvals Non-Incendive Class I, Div. 2, Groups A,B,C,D
Intrinsically Safe Class I, II, III, Div. 1, Groups A,B,C,D,E,F,G
Ex ia IIC
T4 (Ta = –50°C to +93°C);
Intrinsically Safe,
T5 (Ta = –50°C to +85°C);
Zone 0 T6 (Ta = –50°C to +70°C)
Enclosure IP 66/67
3S ● ● ● ● ● ● ● ● ●
Ex ia IIC
T4 (Ta = –50°C to +93°C);
Intrinsically Safe,
T5 (Ta = –50°C to +85°C);
Zone 1
T6 (Ta = –50°C to +70°C)
Enclosure IP 66/67
Ex tD A20 IP6X
Dust-tight Enclosure, T95°C (at Ta = 93°C) or
Zone 0 T80°C (at Ta = 78°C)
Enclosure IP 66/67
Ex d IIC
T5 (Ta = –40°C to +93°C), 33 24 24 24 24 24 24 24 24 24
T6 (Ta = –40°C to +78°C)
Flameproof and Dust-
Supply 11- 42Vdc
tight Enclosure,
Ex tD A21 IP6X
Zone 1 T95°C (at Ta = 93°C) or
T80°C (at Ta = 78°C)
Enclosure IP 66/67

Ex nA, IIC
T5 (Ta = –40°C to +93°C),
T6 (Ta = –40°C to +78°C);
Non-Sparking, Zone 2 Supply < 42Vdc, 23mA
ATEX 10 3N ● ● ● ● ● ● ● ● ●
Zone 2 Ex tD A22 IP6X
(LCIE) T95°C (at Ta = 93°C) or
T80°C (at Ta = 78°C) (Honeywell).
Enclosure IP 66/67

Ex ia IIC
T4 (Ta = –50°C to +93°C);
T5 (Ta = –50°C to +85°C);
T6 (Ta = –50°C to +70°C);
Ui = 30V; Ii = 100mA
11 Ex tD A20 IP6X
Multiple Marking T95°C (at Ta = 93°C) or
T80°C (at Ta = 78°C)
Int. Safe, Zone 0/1
and Dust-tight Enclosure, Ex d IIC
T5 (Ta = –40°C to +93°C),
or T6 (Ta = –40°C to +78°C)
Supply 11- 42Vdc 3C 24 24 24 24 24 24 24 24 24
Flameproof, Zone 1 and Ex tD A21 IP6X
Dust-tight Enclosure, T95°C (at Ta = 93°C) or
T80°C (at Ta = 78°C)
or
Ex nA, IIC
Non-Sparking, Zone 2 T5 (Ta = –40°C to +93°C),
T6 (Ta = –40°C to +78°C);
Zone 2 Supply < 42Vdc, 23mA
Ex tD A22 IP6X
T95°C (at Ta = 93°C) or
T80°C (at Ta = 78°C) (Honeywell)
Enclosure IP 66/67

Table III Approvals continued next page


ST 3000 Smart Pressure Transmitter 23

34-ST-16U-03
Issue 57
Page 4 of 4 STG180 STG14L
STG170 STA14L/17L, STG17L/18L
STG140 STG19L
STA140 STA12L
TABLE III - OPTIONS (continued) STA122
Approval
Approval Type Location or Classification Selection
Body
Canadian Explosion Proof Class I, Div. 1, Groups B,C,D
Standards
Dust-Ignitionproof Class II, III, Div. 1, Groups E,F,G 2J 24 24 24 24 24 24 24 4 24
Association
(CSA) Intrinsically Safe Class I, II, III, Div. 1, Groups A,B,C,D,E,F,G
Ex d IIC;
Flameproof, Zone 1 T5 (Ta = -40 to +93ºC),
T6 (Ta = -40 to +78ºC)
IECEx CA 24 24 24 24 24 24 24 24 24
Ex ia IIC; T3, T4, T5 , T6
Intrinsically Safe,
See Spec for detailed temperature codes by
Zone 0/1
Communications option
Intrinsically Safe,
Ex ia IIC T4, T5, T6 Z2 ● ● ● ● ● ● ● ● ●
Zone 0/1 b
SAEx Flameproof, Zone 1 EX d IIC T5, T6 Enclosure IP 66/67 ZD ● ● ● ● ● ● ● ● ●
(South Africa) Multiple Marking 11
Int. Safe, Zone 0/1, or Ex ia IIC T4, T5, T6 ZA ● ● ● ● ● ● ● ● ●
Flameproof, Zone 1 Ex d IIC T5, T6 Enclosure IP 66/67
CERTUSP
Flameproof, Zone 1 BR- Ex d IIC T5, T6 6D ● ● ● ● ● ● ● ● ●
INMETRO Intrinsically Safe, BR- Ex ia IIC; T4, T5, T6
(Brazil) (See CERTUSP certificate for detailed temperature codes by 6S ● ● ● ● ● ● ● ● ●
Zone 0/1 Communications option)
10
See ATEX installation requirements in the ST 3000 User's Manual
11 The user must determine the type of protection required for installation of the equipment. The user shall then check the box [√] adjacent to the type of
protection used on the equipment certification nameplate. Once a type of protection has been checked on the nameplate, subsequently the equipment
shall not be reinstalled using any of the other certification types.

TABLE IV Selection
Factory Identification XXXX ● ● ● ● ● ● ● ● ●

RESTRICTIONS
Restriction Available Only With Not Available With
Letter Table Selection Table Selection
b Select only one option from this group
d I A _ _, E _ _
e III SM
f III 2J
g III SL
h I _2_
i III 1C or 2J
m III STA12L, STA14L, ME, FF
n III 1C, 2J
o III CR
p III HC or H6 and WP III FF, WX
TC, ME, or FISCO/FNICO
FISCO/FNICO compliance available only with
r III III compliance not available 2J, 3C, 3N,
1C
33, 3S, CA, Z2, ZD, ZA, 6D & 6S
w I E _ G, F _ G, G _ G
x III FF, SM Key # STA12L, STA14L
z I B _ _, F _ _, J _ _
2 III MX, SX III FB, MB, SB
This approval code requires the selection of a
4 III III No CRN Number available
certified conduit plug: A5, A6 or A7
15 III FF
19 III F7, FG
21 III FF
22 III SL
This approval code requires the selection of a
24 III
certified conduit plug: A5, A6 or A7

Ordering Example: STG140-A1A-00000-HC,NE,3H+XXXX

Hastelloy® is a registered trademark of Haynes International


Monel 400® is a registered trademark of Special Metals Corporation.
HART® is a registered trademark of HART Communication Foundation.
FOUNDATIONTM Fieldbus is a trademark of Fieldbus Foundation.
Viton® is a registered trademark of DuPont Performance Elastomers.
Teflon® is a registered trademark of DuPont.
DC®200 and DC®704 are registered trademarks of Dow Corning.
ST 3000 Smart Pressure Transmitter 24

Specifications are subject to change without notice.

For More Information


Learn more about how Honeywell’s ST 3000 Smart
Pressure Transmitters can increase performance, reduce
downtime and decrease configuration costs, visit our
website www.honeywell.com/ps/hfs or contact your
Honeywell account manager.

Honeywell Process Solutions


1860 West Rose Garden Lane
Phoenix, Arizona 85027 34-ST-03-62
August 2011
Tel: 1-800-423-9883 or 1-800-343-0228 © 2011 Honeywell International Inc.
www.honeywell.com/ps