BSC Health Check
BSC Health Check
Sensitivity: Public
PLLDP; (processor load print)
SAOSP; (SAE Operational area print)
SAOCP; !SAOCP STATE SHOULD BE ACTIVE! (operational control print)
SYFDP; !DURATION SHOULD BE 24 HRS! (SW forlopp print hanging forlopps
duration)
SYFSP; (SW forlopp print hanging forlopps status)
SYRIP:SURVEY; (event details)
SAAEP:SAE=ALL; (SAE of all blocks)
SYBFP:FILE; (print of last BSC backups taken)
RXASP:MOTY=RXOTG;
RXASP:MOTY=RXETG;
RLCRP:CELL=ALL; (CELL STATUS PRINT busy/idle)
RLSTP:CELL=ALL; ( CELL ACTIVE/HALT)
RXMSP:MOTY=RXOTX;
RLDEP:CELL=ALL;
RLDEP:CELL=ALL,EXT;
APG Backup
To cater RP fault
exrpp:rp=RP;
exemp:rp=RP,em=all;
blrpi:rp=RP;
blrpe:rp=RP;
sarpi;
expop:rp=RP;
Repri:rp=RP;
remri:rp=RP,pcb=PCB;
recri:rp=RP;
exrpp:rp=RP;
sarpe;
To cater CP fault
Sensitivity: Public
allip;
dpwsp; If CP WO then alarms are of A2, A3 class priority
recci; Internal system check will be performed
if result is
CP REPAIR
NOT SUCCESSFUL
END
Then more inputs are required
repci;
• It will show the possible faulty boards.
CP DIAGNOSIS
TEST RESULT
FAULT
FAULTTYPE
PERMANENT
MAG PCB REPLACED REASON
CPU-B MAU
CPU-A POWC
CPU-B POWC
Daily/Weekly Routines
Sensitivity: Public
RRTPP:TRAPOOL=ALL; STATE TRC DEVICES
Important Commands
Rxotg-Transceiver group
Rxocf-Central function
Sensitivity: Public
Rxotrx-
Rxotx-Transmitter
Rxorx-Receiver
Rxois-Interface switch
Rxotf-Time function
Rxocon-Concentrator
Rxodp-Dip interface handling-Bts-pcm supervision
Sensitivity: Public
21.RRTPP:TRAPOOL=ALL;-Radio transmission transcoder pool.
22.RRTBI:DEV=RTTH1D-8,FORCE;-Manual blocking of transcoder devices.
23.RRTBE:DEV=RTTH1D-8;-Manual deblocking of transcoder devices.
24.RADEP:DEV=RALT-1;-Administration device data.
25.RXAPP:MO=RXOTG-1;-Abis path status.
26.RXMSP:MO=RXOCF-1;-Managed object status.
27.RLGSP:CELL=LA01D1;-Radio control cell,GPRS.
28.RLGSI:CELL=LA01D1;Radio control cell,GPRS,initiate.
29.RLGSE:CELL=LA01D1; Radio control cell,GPRS,end.
30.RAHHP:SNT=ALL;-TRH load table print..
31.RAHTP:SNT=ALL;-TRH device load table print.
32.RAHEP:NOINT=5;-TRH event log print.-Last 5hours log
33.RXTCP:CELL=LA01D1,MOTY=RXOTG;-Admihistration TG to channel group print.
34.RLDEP:CELL=LA01D1;-Radio control cell description data.
35.RLNRP:CELL=LA01D1,CELLR=all;-Neighbour relation data.
36.ALLIP:PRCA=38;
37.ALLIP:PRCA=43;
38.MGBSP:BSC=ALL;-You will get information about name of routs.
39.RRGBP;-Active GPRS or not
40.RLGSP:CELL=ALL;-GPRS
41.NTCOP:SNT=………….; When you get print out level of devices you will use that level in RRTCP comand
42.RRTCP:DEV=RTTGD…&&-RTTGD….;
43.RLACP:CELL=ALL;For adaptive SDCCH Rule of taking TCH channel for SDCCH,per cell.
APG
aploc;
cpfls
cpfrename relfswx relfsw0
exit
MGLAP; Check LAI code on MSC
RLDEP:CELL=ALL; Check LAI on BSC
MGCEP:CELL=ALL; Checking defined CELLs on MSC
BTS Alarms
ABIS PATH UNAVAIL There are not enough Abis paths defined in the TG.
BTS EXTERNAL A fault is external to the BTS equipment.
BTS INTERNAL A fault exists in a piece of equipment which is internal to the
Sensitivity: Public
BTS.
CON QUEUE CONGESTION At least one of the LAPD Concentrator concentration outlet
queues has reached an unacceptable filling level.
FORLOPP RELEASE Raised at the start of a TG Forlopp Release and automatically
ceased on completion of the TG Forlopp Recovery.
LAPD SIGNALLING OVERLOAD Either 16 kbps or 32 kbps Link Access Protocol for the D-
Channel (LAPD) multiplexed communication link is overloaded.
LMT INTERVENTION A Local Maintenance Terminal (LMT) Intervention fault is
received due to local maintenance activities in the BTS.
LOCAL MODE The MO is in Local Mode, or the MO has changed from Local
Mode to Remote Mode while an OML fault exists.
LOOP TEST FAILED An automatic loop test of the traffic carrying capabilities has
failed.
MAINS FAILURE A fault exists in a piece of BTS equipment which indicates a
failure of power source and which may affect the operation of the
BTS currently or in the future. The power source can be either
internal or external to the BTS.
OML FAULT A fault exists in the communications link between the BSC and
the BTS. This alarm includes faults in the transmission
equipment and equipment in the BSC.
OPERATOR CONDITION An abnormal condition has been detected in the BTS site which
does not affect the operational function of the BTS.
PERMANENT FAULT An MO is classified as being permanently faulty when faults in
the MO have occurred and been cleared a certain number of
times within a defined period of time. That is, the MO is
"unstable". Manual intervention is required to bring such an MO
back into operation.
TS SYNC FAULT Synchronization has been lost on the uplink or downlink
Transcoder and Rate Adaptation Unit (TRAU) channels.
TGC FAULT No active Transceiver Group Control (TGC) application exists in
the TG. This is only applicable to the G01 model. The fault can
occur, for example, when communication with an entire BTS is
lost, or when all TRXCs in a BTS are
Sensitivity: Public