Technical Specifications EXTRA EQUIPMENTS


- Charge ammeter
- Moulded case circuit braker (in automatic models)
- Hospital/Critical type silencer
- Sound-proof canopy
- Mobile - trailer
- Synchronization control panel for 2-16 gensets
- 3 pole/4 pole automatic transfer panel (A.T.S.)
- Fuel and oil heater
- Alternator heater
- Automatic fuel filling system
- Fuel-water seperator filter
- PMG warning system

CANOPY
- Modular type sound-proof canopy
ENGINE - Canopy installation executed with screw and nut, without welding process
- Epoxy and polyester powder painted canopy
- PERKINS series heavy duty diesel engine
- Canopy designed for easy maintenance
- 4 cycle, water cooled, turbocharged & air to air COOLED
/turbocharged & air to water COOLED - Lockable doors on both sides of canopy
- Emergency stop button
- Direct injection
- Transparent panel inspection window
- Electronic governor system
- 24 volt self-starter and charger alternator
- Changeable air, fuel and oil filter AUTOMATIC CONTROL PANEL
- Tropical type radiator - LCD display screen - Hardware and materials needed
- Flexible fuel pipe - Battery charger - USB port & RS-485 output
- Oil discharge valve and extention pipe
- Industrial type silencer, exhaust spiral or compensator GEN-SET SAFETY PROTECTION & ALARMS
- Maintenance free battery - High water temperature - Over current load
- Engine block water heater (in automatic models) - Low oil pressure - High & low genset voltage
- Diesel gen-set maintenance and operating instructions and - High & low engine speed - Start/stop failure
electrical circuit diagram - Low radiator water level

QUALITY STANDARD
Our generators are manufactured in compliance with VDE 0530, Easy maintenance canopy design
BSE 4999 BS5000, IEC 34, TS ISO 8528, TS EN ISO 3744, TS EN ISO
3746, TS EN 60034-1, TS EN 60204-1, TS EN 60335-1, TS EN 61439- Refilling from the outside of the canopy
1,
EN 61000, TS EN ISO12100 standards. Canopy made of galvanized steel
We have ISO 9001:2008, ISO 14001:2004, OHSAS 18001:2007 and
ISO10002:2006 management system certificates from Kiwa & MEYER, Warning system for decreasing fuel with electronic fuel level
sender
an accredited independent quality organization.
Our generators up to 400 kw are manufactured in compliance with
2000/14/EC European noise emission directive and certified from Ente
Certificazione Macchine.
We also have TS ISO 8528-4, TS ISO 8528-5, TS EN 13501-1+A1:2013
flame retardancy and TS EN ISO 9227 certificates against anti-corrosion
together with CE Declaration.
ALTERNATOR
- Brushless, single bearing, flexible disc 4 poles alternator for
harmonic failure
- H type isolation class
- IP 21-23 protection class
- Self exciter
- Electronic automatic voltage regulator
- Stator 2/3 step for harmonic failure
- The alternator windings are protected by insulating varnish against
oil and acid.
PERKINS Series
Diesel Generator Sets

PERKINS Series Diesel Generator Sets 10-50 kVA


MODEL E PR XX 0010 E PR XX 0015 E PR XX 0022 E PR XX 0033 E PR XX 0050

kVA 10 15 22,3 33 50
STAND BY
kW 8 12 17,8 26,4 40
GEN-SET POWER
kVA 9 13 20,3 30 45
PRIME
kW 7,2 10,4 16,2 24 36
GROUP

CANOPY DIMESNION (W x L x H) mm 900x1700x1220 900x1700x1220 900x1900x1220 1000x2300x1420 1000x2300x1420

CANOPY WEIGHT kg 650,1 668 760,6 1056,5 1181,5

OPEN DIMENSION (W x L x H) mm 900x1400x1220 900x1400x1220 900x1600x1220 1000x1900x1420 1000x1900x1420

OPEN WEIGHT 503,1 522 606,6 881,5 1006,5

BRAND PERKINS PERKINS PERKINS PERKINS PERKINS

TYPE 403A-11G1 403A-15G1 404A-22G1 1103A-33G 1103A-33TG1

STAND BY kW 9,2 13,2 20,3 30,4 45,6


POWER
PRIME kW 8,4 12 18,4 27,7 41,3

SPEED (rpm) 1500 1500 1500 1500 1500

CYCLE 4 4 4 4 4

DISPLACEMENT (lt) 1,131 1,496 2,216 3,3 3,3

NUMBER OF CYLNDERS 3 IN LINE 3 IN LINE 4 IN LINE 3 IN LINE 3 IN LINE

BORE x STROKE (mm x mm) 77 x 81 84 x 90 4 x 100 105 x 127 105 x 127

COMPRESSION RATIO 23 : 1 22,5 : 1 23,3 : 1 19,25 : 1 17,25 : 1


ENGINE

GOVERNOR TYPE MECHANIC MECHANIC MECHANIC MECHANIC MECHANIC

INDUCTION NATURAL NATURAL NATURAL NATURAL TURBOCHARGED

COMBUSTION SYSTEM INDIRECT INDIRECT INDIRECT DIRECT DIRECT

COOLING SYSTEM WATER WATER WATER WATER WATER

%100 PRIME POWER 3 3,7 5,3 7,2 10,8


FUEL
CONSUMPTION %75 PRIME POWER 2,3 2,8 4 5,61 8,23
lt / h
%50 PRIME POWER 1,7 2 2,9 4,06 5,83

TOTAL LUBRICATION SYSTEM CAPACITY (lt) 4,9 6 10,6 8,3 7,9

TOTAL COOLANT CAPACITY (lt) 5,2 6 7 10,2 10,2

FUEL TANK CAPACITY (lt) 82 82 82 101 101