Burkert - Turbina DSS030-Standard-EU-EN
Burkert - Turbina DSS030-Standard-EU-EN
Burkert - Turbina DSS030-Standard-EU-EN
Type S030
Product variants described in the data sheet may differ from the product presentation and description.
Type 8611
eCONTROL - Universal
controller
Table of contents
1. General technical data 3
2. Approvals 4
2.1. Certification FDA.....................................................................................................................................................................4
2.2. Pressure Equipment Directive.................................................................................................................................................4
Device used on a pipe............................................................................................................................................................4
3. Materials 5
3.1. Chemical Resistance Chart – Bürkert resistApp....................................................................................................................5
3.2. Material specifications............................................................................................................................................................5
4. Dimensions 6
4.1. Metal sensor-fitting.................................................................................................................................................................6
Internal thread connection......................................................................................................................................................6
External thread connection.....................................................................................................................................................6
Weld end connection..............................................................................................................................................................7
Clamp connection...................................................................................................................................................................8
Flange connection..................................................................................................................................................................9
4.2. Plastic sensor-fitting...............................................................................................................................................................9
True union connection with nut and solvent/fusion socket....................................................................................................9
Solvent/fusion spigot connection.........................................................................................................................................10
5. Performance specifications 11
5.1. Pressure temperature diagram..............................................................................................................................................11
With sensor-fitting S030 standard........................................................................................................................................11
With sensor-fitting S030-HT.................................................................................................................................................11
6. Product installation 12
6.1. Installation notes...................................................................................................................................................................12
6.2. Selection of the nominal diameter........................................................................................................................................12
7. Product operation 13
7.1. Measuring principle..............................................................................................................................................................13
9. Product accessories 14
Product properties
Materials
Please make sure the device materials are compatible with the fluid you are using.
Detailed information can be found in chapter “3.1. Chemical Resistance Chart – Bürkert resistApp” on page 5.
Wetted parts
Body, sensor armature Stainless steel (316L ‑ 1.4404), brass (CuZn39Pb2), PVC, PP or PVDF (depending on S030 version)
Seal FKM or EPDM (depending on S030 version).
Detailed information can be found in chapter “11.4. Ordering chart” on page 17
Axis Ceramics (Al2O3)
Bearings • Ceramics (Al2O3)
• Iglidur® (only for S030-HT)
Paddle wheel • PVDF
• Stainless steel (316L ‑ 1.4404) (only for S030-HT)
• PP on request
Screws Stainless steel (316L ‑ 1.4404)
Dimensions Detailed information can be found in chapter “4. Dimensions” on page 6
Compatibility • With flow transmitter Type SE30, SE30 Ex, SE32, SE35, SE36, batch controller SE35 or 8611 Univer-
sal controller
• Only with flow transmitter Type SE30-HT for S030-HT versions
Pipe diameter DN 06…DN 65
Performance data
Measuring range 0.5…1200 l/min
Measurement deviation • Teach-In (via a remote transmitter): ± 1 % of the measured value1.) (at Teach-In flow rate value)
• Standard K-factor: ± 2.5 % of the measured value1.)
Linearity ± 0.5 % of full scale1.)
Repeatability ± 0.4 % of the measured value1.)
Medium data
Fluid Clean, neutral or slightly aggressive, solid-free liquids
Viscosity 300 cSt. max.
Rate of solid particles Max. 1 %
Maximum particle size 0.5 mm
Velocity • 0.3…10 m/s
• 0.5…10 m/s (only for S030-HT)
Detailed information can be found in chapter “6.2. Selection of the nominal diameter” on page 12.
Fluid temperature For sensor-fitting in
• PVC: 0…+ 50 °C (+ 32…+ 122 °F)
• PP: 0…+ 80 °C (+ 32…+ 176 °F)
• Stainless steel, brass or PVDF: - 15…+ 100 °C (+ 5…+ 212 °F)
• Stainless steel (S030-HT): - 15…+ 125 °C (+ 5…+ 257 °F)
Fluid pressure (max.) For sensor-fitting in
• Plastic PN 10
• Metal: PN 16
• Stainless steel (S030-HT):
–– PN 40 (for - 15…+ 90 °C (+ 5…+ 194 °F) temperature range)
–– PN 25 (for + 90…+ 125 °C (+ 194…+ 257 °F) temperature range)
Detailed information can be found in chapter “5.1. Pressure temperature diagram” on page 11.
Approvals and Certificates
Directives
CE directives The applied standards, which verify conformity with the EU Directives, can be found on the EU Type
Examination Certificate and/or the EU Declaration of conformity (if applicable)
2. Approvals
2.1. Certification FDA
Note:
The specific sensor fittings (S030-HT) for the measurement of flow rates at high temperature and pressure is not covered by this
certification.
Certificates Description
FDA The versions with the body and the sensor armature made of PVDF or stainless steel materials, the paddle wheel
made of PVDF material and the seal made of FKM or EPDM materials comply in their composition with the Code of
Federal Regulations published by the FDA (Food and Drug Administration, USA).
3. Materials
3.1. Chemical Resistance Chart – Bürkert resistApp
You want to ensure the reliability and durability of the materials in your individual
application case? Verify your combination of media and materials on our website or in
our resistApp.
1
2
4
5
4. Dimensions
4.1. Metal sensor-fitting
Internal thread connection
Note:
Specifications in mm
DN P A D L
[inch]
P
NPT ½ 17.0
Rc ½ 15.0
L
20 32.0 94.0 G ¾ 17.0
A
NPT ¾ 18.3
Rc ¾ 16.3
25 32.2 104.0 G 1 23.5
NPT 1 18.0
Rc 1 18.0
32 35.8 119.0 G 1 ¼ 23.5
NPT 1 ¼ 21.0
Rc 1 ¼ 21.0
40 39.6 129.0 G 1 ½ 23.5
NPT 1 ½ 20.0
Rc 1 ½ 19.0
50 45.7 148.5 G 2 27.5
NPT 2 24.0
Rc 2 24.0
G, NPT or Rc in stainless steel (316L ‑ 1.4404), brass (CuZn39Pb2), PVC (only DN 06 and DN 08) or PVDF (only DN 08)
DN P A D L
[inch]
P
DN P A D
25 32.0 130 Rd 40 x 1/6"
P
EN ISO 1127/ISO 4200/DIN 11866 series B, SMS 3008, BS 4825‑1/ASME BPE/DIN 11866 series C or DIN 11850 series 2/DIN 11866
series A/ DIN EN 10357 series A in stainless steel (316L ‑ 1.4404)
DN P A Standard D s
s
08 – – EN ISO 1127/ISO 4200/DIN 11866 series B – –
P
– – SMS 3008 – –
D
Clamp connection
Note:
Specifications in mm
DIN 32676 series B, SMS 30171.), BS 4825‑3/ASME BPE1.) or DIN 32676 series A in stainless steel (316L ‑ 1.4404)
DN P A Standard D D1 (D2)
08 – – DIN 32676 series B2.) – – –
P
– – SMS 3017 – – –
D1
D2
D
– – ASME BPE – – –
29.5 125 DIN 32676 series A 34.0 27.5 10.00
A
15 34.5 130 DIN 32676 series B2.) 34.0 27.5 18.10
– – SMS 3017 – – –
– – ASME BPE – – –
29.5 119 DIN 32676 series A 34.0 27.5 16.00
20 32.0 150 DIN 32676 series B 50.5 43.5 23.70
– – SMS 3017 – – –
34.5 119 ASME BPE 25.0 19.6 15.75
34.5 119 DIN 32676 series A 34.0 27.5 20.00
25 32.2 160 DIN 32676 series B 50.5 43.5 29.70
32.0 129 SMS 3017 50.5 43.5 22.60
32.0 129 BS 4825‑3/ASME BPE 50.5 43.5 22.10
32.0 136 DIN 32676 series A 50.5 43.5 26.00
32 35.8 180 DIN 32676 series B 50.5 43.5 38.40
– – SMS 3017 – – –
– – BS 4825‑3/ASME BPE – – –
– – DIN 32676 series A – – –
40 39.6 200 DIN 32676 series B 64.0 56.5 44.30
35.8 161 SMS 3017 50.5 43.5 35.60
35.8 161 BS 4825‑3/ASME BPE 50.5 43.5 34.80
35.8 161 DIN 32676 series A 50.5 43.5 38.00
50 45.7 230 DIN 32676 series B 77.5 70.5 55.10
39.6 192 SMS 3017 64.0 56.5 48.60
39.6 192 BS 4825‑3/ASME BPE 64.0 56.5 47.50
39.6 170 DIN 32676 series A 64.0 56.5 50.00
65 – – DIN 32676 series B – – –
45.7 216 SMS 3017 77.5 70.5 60.3
45.7 216 BS 4825‑3/ASME BPE 77.5 70.5 60.2
– – DIN 32676 series A – – –
1.) Available with internal surface finish Ra = 0.8 µm
2.) Similar to DIN 32676 series B but with clamp 34.0
Flange connection
Note:
Specifications in mm
DN P A Standard L Z D D1 D2
15 34.5 130 EN 23.5 4 x 14.0 95.0 65.0 45.0
130 ANSI 4 x 15.8 89.0 60.3 34.9
152 JIS 4 x 15.0 95.0 70.0 51.0
P
D2
D1
D
150 ANSI 4 x 15.8 99.0 69.8 42.9
178 JIS 4 x 15.0 100.0 75.0 56.0
25 32.2 160 EN 28.5 4 x 14.0 115.0 85.0 68.0
Z
160 ANSI 4 x 15.8 108.0 79.4 50.8
L
216 JIS 4 x 19.0 125.0 90.0 67.0
A 32 35.8 180 EN 31.0 4 x 18.0 140.0 100.0 78.0
180 ANSI 4 x 15.8 117.0 88.9 63.5
229 JIS 4 x 19.0 135.0 100.0 76.0
40 39.6 200 EN 36.0 4 x 18.0 150.0 110.0 88.0
200 ANSI 4 x 15.8 127.0 98.4 73.0
241 JIS 4 x 19.0 140.0 105.0 81.0
50 45.7 230 EN 41.0 4 x 18.0 165.0 125.0 102.0
230 ANSI 4 x 19.0 152.0 120.6 92.1
267 JIS 4 x 19.0 155.0 120.0 96.0
DIN 8063, ASTM D 1785/76 or JIS K in PVC DIN 16962 in PP or ISO 10931 in PVDF
DN P A Standard A1 A2 D D1
081.) 29.5 122.0 DIN/ISO 92 90 12.00 –
P
– ASTM – – – –
– JIS – – – –
D1
D
DN P A Standard L D H
15 34.5 90 DIN 8063 16.5 20 17.5
P
5. Performance specifications
5.1. Pressure temperature diagram
With sensor-fitting S030 standard
Application range for complete device (sensor-fitting Type S030
+ transmitter Type SE30, SE32, SE35, SE36 or 8611)
16
14
12
10
0
-20 0 20 40 60 80 100
Fluid temperature °C
45
Pressure (bar)
40
35
30
25
20
15
10
Fluid temperature °C
Stainless steel
6. Product installation
6.1. Installation notes
Note:
The device is not designed for gas and steam flow measurement.
Minimum straight upstream and downstream distances must be observed. According to the pipe’s design, necessary distances can
be bigger or use a flow conditioner to obtain the best accuracy.
Make sure that the measuring conditions at the point of measurement are calm and problem-free.
50 x DN 5 x DN 25 x DN 5 x DN 18 x DN 5 x DN
40 x DN 5 x DN 20 x DN 5 x DN 15 x DN 5 x DN
1.) If the valve cannot be mounted after the measuring device, the minimal distances have to be respected.
2.) If an expansion cannot be avoided, the minimal distances have to be respected.
Please note minimum flow velocity
The complete measuring device can be installed into either horizontal or vertical pipes.
Important criteria for this are; ensure that the measurement pipe is fully filled and that the measurement pipe is air bubble free.
Incorrect
Correct Incorrect Incorrect
Correct
Correct
Correct Incorrect
Pressure and temperature ratings must be respected according to the selected sensor-fitting material. The suitable pipe size is se-
lected using the diagram for selecting the nominal diameter of the sensor-fitting.
Note:
For the sensor fittings listed below, the corresponding nominal size in the bracket must be used:
• External threads acc. to SMS 1145
• Weld ends acc. to SMS 3008, BS4825‑1/ASME BPE/DIN 11866 series C or DIN 11850 series 2/DIN 11866 series A/
DIN EN 10357 series A
• Clamp acc. to SMS 3017, BS 4825‑3/ASME BPE or DIN 32676 series A
For all other sensor fittings, the corresponding nominal diameter without clamp applies.
Example 1:
• nominal flow: 10 m3/h
• optimal flow rate: 2…3 m/s
Result: Select a pipe size of DN 40
Not recommended
S030 (standard) Optimal flow rate
S030-HT Diameter of example 1 and example 2
gpm m3/h
Flow rate
1000 l/min
3000 200
DN32 (DN40)1.)
DN
) 1.)
100
65
20
N
DN25 (DN32)1.)
(D
)
1.
50
)
DN
50
10
)
1.
40
)
40
DN
N
(D
)
1.
32
5
DN
20 DN20)1.)
(D
)
1.
25
)
25
DN
50
(D
20
10
DN
2
) 1.)
DN08
20
or 15
DN
15 DN
5 20
1
N
DN06
(D
10
2 0.5
08
DN
5
06
1
DN
0.2
0.5 2
0.1
1
0.2 0.05
0.5
0.1
0.02
0.05 0.2
0.01
0.1 0.3 0.5 1 3 5 10 m/s
0.3 0.5 1 3 5 10 30 fps
Flow velocity
1.) See note at the beginning of this chapter.
7. Product operation
7.1. Measuring principle
When liquid flows through the pipe, the paddle wheel with 4 inserted magnets is set in rotation producing a frequency signal in the
transducer (Hall sensor) of the mounted transmitter. The rotation is detected contactless through the sensor-fitting wall. The frequen-
cy signal is proportional to the flow velocity of the fluid.
See Data sheet Type 8030 Inline flowmeter, Data sheet Type 8032 Flowmeter/threshold detector, Data sheet Type 8035
Inline flowmeter or batch controller, Data sheet Type 8036 Inline flowmeter, ELEMENT design or Data sheet Type 8611 eCON-
TROL - Universal controller for more information.
Transmitter
Type SE32
Inline
sensor-fitting
Type S030
9. Product accessories
Note:
Since March 2012, sensor-fittings Type S030 in DN 15 and DN 20 exist in two versions, that have different K factors. The second
version is identified by the marking “v2”.
This “v2” marking can be found:
• on the bottom of the DN 15 or DN 20 sensor-fitting in plastic
V2
Type S030
Transmitter
Type SE30 Type SE30 Ex Type SE32 Type SE35 Type SE35 Type SE36 Type 8611
Flow t ransmitter Flow transmitter Flow t ransmitter Flow transmitter Batch c ontroller ELEMENT trans- eCONTROL
for Inline for hazardous for Inline for Inline for Inline mitter for Inline - Universal
sensor-fitting areas sensor-fitting sensor-fitting sensor-fitting sensor-fitting controllers
Type 8611
Type 8619 Type 8025
eCONTROL - Universal controller
multiCELL - transmitter/controller Flow transmitter
panel, wall or rail-mounting version
1.) Only for SE30Ex: depending on the category, to be used with an intrinsic safety barrier with NAMUR input
You want to find your desired Bürkert product or spare part quickly and order d irectly?
Our online shop is available for you 24/7. Sign up and enjoy all the benefits.
Two different components must be ordered in order to select a complete device. The following information is required:
• Article no. of the desired flow transmitter (see Data sheet Type 8030 , Data sheet Type 8032 , Data sheet Type 8035 , Data
sheet Type 8036 or Data sheet Type 8611 )
• Article no. of the selected S030 Inline sensor-fitting (see chapter “11.4. Ordering chart” on page 17)
DIN 11866 series B
Clamp connection
DIN 32676 series B – – – 424034 424035 424036 424037 424038 424039 –
4.)
Flange connection
EN 1092‑1/B1/ – – – 424040 424041 424042 424043 424044 424045 –
PN 16
ANSI B16‑ 5 – – – 424046 424047 424048 424049 424050 424051 –
JIS 10K – – – 430108 430109 430110 430111 430112 430113 –
EPDM seal
External thread connection
SMS 1145 – – – – – 443306 – 443307 443308 –
Weld end connection
SMS 3008 – – – – – 443298 – 443299 443300 443374
6.)
DIN 11866 series C
DIN 11850 series 2/ – – 551788 551789 551790 551791 – 551792 551793 –
DIN 11866 series A/
DIN EN 10357
series A
Clamp connection
SMS 3017 – – – – – 443302 – 443303 443304 443399
6.)
Stainless steel - with PVDF paddle wheel - Fluid temperature max. 100 °C, PN 40
FKM seal
Internal thread connection
G – – – 427138 425737 425729 427152 427153 427154 –
1.) External thread
2.) Internal surface finish Ra = 0.8 µm
3.) EPDM seal
4.) Refer to Clamp with D dimensions of 34 mm (see chapter “Clamp connection” on page 8)
5.) DN 20 only available in ASME BPE
6.) Please refer to ASME BPE
Plastic sensor-fitting
PP with paddle wheel (PP), seal (FKM), screws and certificate for DN 15…DN 65 552881
PP with paddle wheel (PP), seal (EPDM), screws and certificate for DN 15…DN 65 443983
PVDF with paddle wheel (PVDF), seal (FKM), screws and certificate for DN 06, DN 08, DN 15 v2 and DN 20 v2 448676
PVDF with paddle wheel (PVDF), seal (FKM), screws and certificate for DN 15 (except DN 15 v2 and DN 20 v2)...DN 65 432302
PVDF with paddle wheel (PVDF), seal (EPDM), screws and certificate for DN 15 (except DN 15 v2 and DN 20 v2)... 432301
DN 65
Sensor holder for version High Temperature
Stainless steel with paddle wheel (stainless steel), seal (FKM) and screws for DN 15 (except DN 15 v2 and DN 20 v2)... 551764
DN 50
Stainless steel with paddle wheel (stainless steel), seal (FKM) and screws for DN 06, DN 08, DN 15 v2 and DN 20 v2 449723
Stainless steel with paddle wheel (stainless steel), seal (EPDM) and screws for DN 15 (except DN 15 v2 and 551763
DN 20 v2)...DN 50
Stainless steel with paddle wheel (stainless steel), seal (EPDM) and screws for DN 06, DN 08, DN 15 v2 and DN 20 v2 449724
O-ring set
FKM - for metal sensor-fitting, DN 06…DN 65 426340
EPDM - for metal sensor-fitting, DN 06…DN 65 426341
FKM - for plastic sensor-fitting, DN 08 448679
FKM - for plastic sensor-fitting, DN 15 431555
FKM - for plastic sensor-fitting, DN 20 431556
FKM - for plastic sensor-fitting, DN 25 431557
FKM - for plastic sensor-fitting, DN 32 431558
FKM - for plastic sensor-fitting, DN 40 431559
FKM - for plastic sensor-fitting, DN 50 431560
EPDM - for plastic sensor-fitting, DN 08 448680
EPDM - for plastic sensor-fitting, DN 15 431561
EPDM - for plastic sensor-fitting, DN 20 431562
EPDM - for plastic sensor-fitting, DN 25 431563
EPDM - for plastic sensor-fitting, DN 32 431564
EPDM - for plastic sensor-fitting, DN 40 431565
EPDM - for plastic sensor-fitting, DN 50 431566
Approvals/Certificates
Inspection certificate 3.1 (acc. to EN‑ISO 10204) 803723
Test report 2.2 (acc. to EN‑ISO 10204) 803722
Certification of Conformity for the surface Quality (DIN4762‑DIN4768‑ISO/4287/1) 804175
3 points Flow calibration certificate (S020 combined with the flow device inserted, only for DN ≤ 200) 550676
FDA approval 803724
China
Canada Hong Kong
USA India
Japan
Korea
Malaysia
United Philippines
Brazil Arab Singapore
Uruguay Emirates Taiwan
South Africa
Australia
New Zealand
Credits, © and concept: Christian Bürkert GmbH & Co. KG | Photographs: Marc Eggimann Fotografie - 4051 Basel | Scanner GmbH - Werbeagentur Künzelsau -