Catalogue Maclev Access Floor

Download as pdf or txt
Download as pdf or txt
You are on page 1of 32

sMac Floor System

FACTORY FINISHED PANELS 04


- Cement Infill Steel Raise Acess Floors (Finished) 05
- Calcium Sulphate Raised Access Floors 06
- Woodcore Raised Access Floors 07

FACTORY BARE PANELS 08


- Cementitious Infill Steel Raised Access Floors Systems 09
- Steel Encapsulated Calcium Sulphate Raised Access Floors 10
- Steel Encapsulated Woodcore Raised Access Floors 11

OUTDOOR RAISED ACCESS FLOOR 12


- Adjustable Plastic Pedestal 13

PERFORATED DATA CENTER PRODUCTS 14


- Temperature Control Fan System 15

CLEANROOM PRODUCTS 16
ACCESORIES 22
INSTALLATION PROCEDURES 23
JOB REFERENCES 24
RAISED FLOOR COMPONENTS 25
FLOOR SYSTEMS 26
USER’S GUIDE 28
- Installation Warning 29

QUALITY INSPECTION 30
VALUED CUSTOMERS 31
MISSION
sMac provides variety of access floor products and services for
difference building material to respond the need & usage of every
co
onstruction industry with excellent quality products that present only
fo
or the best to our clients.

VISION
sMac will constantly provide & develop new products to respond the needs
of Thai market especially on quality functionality and services beyond cOLHQW·V
expectations.

COMPANY PROFILE
)RXQGLQV0DF&RUSRUDWLRQ/WGVHWRXWLWVHOIWREHDOHDGLQJUDLVHGDFFHVVIORRUFRPSDQ\IRUERWK
VXSSO\DQGLQVWDOODWLRQ'XULQJWKHVHGD\VZHKDYHEHHQSURYLGLQJQRWRQO\JRRGTXDOLW\UDLVHGIORRUV\VWHP
but also before and after sale services especially our raised floor expert engineers who always provide good
advice to clients for both brand new projects and also renovation projects. This is to make sure that customers
will get what they are looking for.
7RNHHSRXUTXDOLW\FRQVLVWHQF\ZHNHHSGHYHORSLQJUDLVHGIORRUV\VWHPVXFKDVODWHVWSDWHQWPRXOGKLJK
VWUHQJWKFHPHQWIRUPXOD$QWLVWDWLF6XUIDFHHWF7KLVLVWRHQVXUHWKDWZHKDYHVXSSOLHGKLJKTXDOLW\UDLVHGIORRU
V\VWHPZKLFKZLOOPHHWRXUFXVWRPHU·VUHTXLUHPHQWV%HVLGHRXUJLJDQWLFZDUHKRXVHDOZD\VVXSSO\YDULRXV
W\SHVRIUDLVHGIORRUSDQHOVIRUPRUHWKDQPLQWRWDOWRPDNHVXUHWKDWZHFDQVHUYHRXUFXVWRPHUVULJKW
in time.
2IFRXUVHV0DFDOVRSD\RXUDWWHQWLRQIRUGHYHORSLQJVNLOORIRXULQVWDOODWLRQVWDIIVVXFKDVVDIHW\WUDLQLQJ
PDFKLQHVDQGWRROVWUDLQLQJDQGVHUYLFHVPLQGWUDLQLQJHWF%\GRLQJVRV0DFEHOLHYHWKDWZHFDQSURYLGH
high skill installer to do installation and educate our clients to maintain raised floor system as well.The following
projects are some of our main valued customers that we have been installed and serviced.

6&%+($'2)),&(   ¬   640


*/$1'72:(5      640
- THE ELECTRICITY GENERATING AUTHORITY OF THAILAND 640
- CANON PRACHINBURI 640
- MACO EC BUILDING EXPANSION 640
6$7+251648$5(72:(5     640
- CITY LINK BUILDING 640
- G H BANK 640
1(&&25325$7,21 7+$,/$1' &2/7'   640
- AEON MODERNFORM TOWER 640
- CPF CULINARY SCHOOL EMPORIUM TOWER 640
- SONGKHLA RAJABHAT UNIVERSITY 640
- AMERCAN STANDARD 640
- TOSHIBA 640
- BURAPA UNIVERSITY CHON BURI 640
- SINSATHORN TOWER 640
- LION 640
- PTT RAYONG 640
- SIAM DISCOVERY 640
/$.(5$7&+$'$2)),&(     640
FACTORY FINISHED
PANELS

S-AC&ACTORY&INISHEDFLOORSOFFERACHOICEOFCERAMIC MARBLE GRANITE


carpet
WOOD BAMBOO GLASS LAMINATE RUBBERORLINOLEUMsurfaces. All finishes
AREFULLYACCESSIBLEANDINSPECTABLE ANDALLREADYFORINSTALLATION
sMac factory finished floors come in a wide range of materials and
finishes to satisfy all possible technical and decorative need.
glass /ceramic tile
All stages in sMacPRODUCTIONPROCESS FROMDESIGNTOINSTALLATION
are 100% to guarantee quality and reliably short delivery times.

HPL / PVC laminated

rubber / linoleum

HPL

woodcore panels

calcium sulphate panels

steel cement HPL

cement infill steel panels

sMac Corporation 4
FINISHED
FACTORY

PANELS
Cement Infilled Ste
Steel Raised

BARE PANELS
Access
ess Floor

FACTORY
(Finished Type)

RAISED FLOOR
OUTDOOR
Introduction of Products
The floor used two layers of choice cold-rolled steel sheets. The lower hydraulic-stretched sheet
is connected with the upper sheet through high-frequency programmed full-auto butt-welding

DATA CENTER
PERFORATED
at the highest point of the formed nest-like center. After de-oiled and phosphor aid it is sprayed

PRODUCTS
with matt epoxy resin powder on the surface and filled with foaming cement in the middle.
The surface of the floor is posted with hpl high pressing laminate or pe antistatic renew and
glued with pvc conductive trim around.
Characteristics

CLEANROOM
PRODUCTS
s &ULLSTEELSTRUCTURE HIGH QUALITYLIGHTWEIGHTCEMENTINFILLED
s 0ANELSURFACEISPAINTEDELECTROSTATICALLYWITHCONDUCTIVEEPOXYRESIN
s ,OCKHOLEINFOURCORNERSTOMAKETHEWHOLESYSTEMRIGID
s !DJUSTABLEHEIGHTFORPEDESTALAPPLIEDPATENT ASSEMBLYAGILITY
large wire good exchange ability.

DATA CENTER
REMOVING SAVINGCOST LONGPERFORMANCELIFE
s (IGHRECYCLED CONVENIENTREMOVING SAVINGCOST LONGPERFORMANCELIFE

PRODUCTS
ACCESORIES
INSTALLATION
PROCEDURES
JOB REFERENCE/
ACCESS FLOOR
COMPONENTS
FLOOR SYSTEMS

T e chnica l S p e c i f i c ati o n

N
Concentrated Load Rolling Load
International Size N N N/m2
(mm) LB N Kg Impact Load Ultimate Load Uniform load 10 10000
Times Times
USER’S GUIDE

FS800 600X600X35 > 800 > 3560 > 363 > 536 > 10680 > 16100 3560 2670

FS1000 600X600X35 > 1000 > 4450 > 450 > 670 > 13350 > 23000 4450 3560

FS1250 600X600X35 > 1250 > 5560 > 567 > 780 > 16680 > 33000 5560 4450

FS1500 600X600X35 > 1500 > 6660 > 680 > 1005 > 19980 > 34500 6675 5340
INSPECTION/

CUSTOMERS
QUALITY

VALUED

sMac Corporation 5
Calcium sulphate Raised
Access Floor

Calcium sulphate Core

HPL/ Vinyl

Introduction of Products
c
cts
Calcium sulphate raised floorr panel is made of
environment friendly plant’ss fibre as the
reinforcement material to solidify
lidify the calcium PVC Trim
sulphate crystals. Nowadays, calcium
l i sulphate
l h t
has become the future of raised floor because Steel Plate
of good features in environment, fireproof,
protection, high loading capacity, flatness and so on.
Characteristics
s %NVIRONMENTFRIENDLYCALCIUMSULPHATEBOARD
s !NTI STATIC HIGHDIMENSIONALPRECISION STRONG
loading ability and shockproof, fireproof
s !DJUSTABLEHEIGHTFORPEDESTAL ASSEMBLYAGILITY
large wire, good exchangeability.
s /UTLETMATING %LEGANTAPPEARANCEFORPAVINGWIDELY
brand top tiles
s "EINGSTABLEPERFORMANCEINHUMIDITYTEMPERATURE

Te chnica l S pe c i f i c at i o n
N
Concentrated Load Rolling Load
International Size N N N/m2
(mm) LB N Kg Impact Load Ultimate Load Uniform load 10 10000
Times Times

FS800 600 X 600 X 30/ 40 > 800 > 3560 > 363 > 563 > 16080 > 16100 3560 2670

FS1000 600 X 600 X 30/ 40 > 1000 > 4450 > 450 > 670 > 13350 > 23000 4450 3560

FS1250 600 X 600 X 30/ 40 > 1250 > 5560 > 567 > 780 > 16680 > 33000 5560 4450

FS1500 600 X 600 X 30/ 40 > 1500 > 6660 > 680 > 1005 > 19980 > 34500 6675 5340

sMac Corporation 6
FINISHED
FACTORY

PANELS
BARE PANELS
FACTORY
RAISED FLOOR
OUTDOOR
Wood core Raised
Access Floor

DATA CENTER
PERFORATED

PRODUCTS
CLEANROOM
PRODUCTS
HPL/ PVC Vinyl

Steel Plate

DATA CENTER
PRODUCTS
Introduction of Products
ctts PVC Trim
!DVANCEDTECHNOLOGY IMPORTEDHIGHQUALITYCHIPBOARDBASE
TEEDHIGHQUALITYCHIPBOARD BASSE
material or particle board. Tile
ilee could be HPL oro
PVC ceramics (granite). Four sides; conductive regular.

ACCESORIES
"OTTOMPANELALUMINUMFOILORGALVANIZEDSTEEL Wood Core
Stringer; pressure forming and conductive tile
COVER LEADSCREWCOULDADJUSTHEIGHT

INSTALLATION
PROCEDURES
Characteristics
s(IGHQUALITYCHIPBOARDPANELENCAPSULATEDBYGALVANIZEDSTEEL
s,IGHTWEIGHTBUTHIGHLOADINGCAPACITY
s3OUND PROOFINGANDGOODSEALING
s.ICEAPPEARANCE
JOB REFERENCE/
ACCESS FLOOR
COMPONENTS

s0ANELCOULDBEWITHORWITHOUTCORNERLOCKHOLE
FLOOR SYSTEMS

T e chni c a l S p e c i f i cati o n
N
Concentrated Load Rolling Load
International Size N N N/m2
(mm) LB N Kg Impact Load Ultimate Load Uniform load 10 10000
Times Times

FS 440 600 X 600 X 32 > 440 > 1960 > 200 > 295 > 5880 > 9720 1958 1566
USER’S GUIDE

FS 662 600 X 600 X 40 > 662 > 2950 > 301 > 445 > 8850 > 12500 2946 2356

FS 800 600 X 600 X 40 > 800 > 3560 > 363 > 536 > 10680 > 16100 3560 2670

FS 1000 600 X 600 X 40 > 1000 > 4450 > 450 > 670 > 13350 > 23000 4450 3560
INSPECTION/

CUSTOMERS
QUALITY

VALUED

sMac Corporation 7
FACTORY
BARE PANELS

sMac’s Bare Panels in cement, wood agglomerate and calcium


sulphate are available in fully steel, steel encapsulated, alufoil
backing, double alufoil (calcium sulphate panels only).
They permit direct or access-panel inspection of the under-floor
plenum, and are ideal for use in buildings that have to be fully
homologated prior to delivery to the customer and prior to
finalization of the room layout. All sMac bare panel floors can be
covered after installation using any type of commercially
available floor covering.

Alufoil backing
WOODCORE PANELS

CALCIUM SULPHATE PANELS Double alufoil backing

Fully steel encapsulated

Cementitious infill

sMac Corporation 8
FINISHED
FACTORY

PANELS
Cementitious Infill

BARE PANELS
Steel Raised Access

FACTORY
Floor System

RAISED FLOOR
OUTDOOR
DATA CENTER
PERFORATED

PRODUCTS
CLEANROOM
PRODUCTS
DATA CENTER
PRODUCTS
Introduction of Products
Bare steel access floor is specially designed for 5A office building,

ACCESORIES
flexible for installation in intelligence office rooms as requirements.
Sound-proof and easy-cleaning, antistatic PVC or carpet finishing tile
for OA access floor make a soft acoustic walking feeling.

INSTALLATION
PROCEDURES
Characteristics
s &ULLSTEELSTRUCTURE HIGH QUALITYLIGHTWEIGHTCEMENTINFILLED
s 0ANELSURFACEISPAINTEDELECTROSTATICALLYWITHCONDUCTIVEEPOXYRESIN
s ,OCKHOLEINFOURCORNERSTOMAKETHEWHOLESYSTEMRIGID
s !DJUSTABLEHEIGHTFORPEDESTALAPPLIEDPATENT ASSEMBLYAGILITY
large wire good exchange ability.
JOB REFERENCE/
ACCESS FLOOR
COMPONENTS

s (IGHRECYCLED CONVENIENTREMOVING SAVINGCOST LONGPERFORMANCELIFE


FLOOR SYSTEMS

Technical Specification
N
Concentrated Load Rolling Load
International Size N N N/m2
(mm) LB N Kg Impact Load Ultimate Load Uniform load 10 10000
Times Times

FS800 600 X 600 X 33 > 800 > 3560 > 363 > 563 > 10680 > 16100 3560 2670
USER’S GUIDE

FS1000 600 X 600 X 33 > 1000 > 4450 > 450 > 670 > 13350 > 23000 4450 3560

FS1250 600 X 600 X 33 > 1250 > 5560 > 567 > 780 > 16680 > 33000 5560 4450

FS1500 600 X 600 X 33 > 1500 > 6660 > 680 > 1005 > 19980 > 34500 6675 5340
INSPECTION/

CUSTOMERS
QUALITY

VALUED

sMac Corporation 9
Steel Encasuled
Cacium Sulphate
Raised Access Floor

Introduction
ion of Products
4HEFLOORISMADEOFCALCIUMSULFATEAKINDOFORGANICMATERIALS 
MADEOFCALCIUMSULFATEAKINDOFORGANICMATE
D F L I LF T  KI D F I TERI
RIA
IALLS
LS 

Its core is made though dehydrated crystallization according to the
features of calcium sulfate short fibber, and wrapped with choice
galvanized steel plate. Considering that calcium sulfate can resist
the high temperate of 1450ºC, the seamless connection is made between
the upper and lower galvanized steel plates when the floor is designed
ANDMADE WHICHCANBLOCKHEATTRANSMITTANCEMOREEFFECTIVELYSOASTO
increase the time of escape in case of fire. The intentional exposure
OF MMCOREONTHEFOURCORNERSOFTHEFLOORACCORDINGTOTHE
CHARACTERISTICSOFCALCIUMSULFATEISAIMEDATSELF REGULATINGTHEDRYNESSAND
HUMIDITYOFINDOORAIR4HEREAREANGLEKEYNOTESONTHEFOURCORNERS
Characteristics
s3MARTSIZEXXMMEASYFORTHEHAND
s(IGHLOADINGCAPACITY
s%LEGANTAPPEARANCE
s0ANELSCORNERCOULDWITHORWITHOUTLOCKHOLES
s7ILDLYUSEINOFFICEBUILDING HOTELANDMEETINGROOMx

Te chni c a l S pe c if i cati o n
N
Concentrated Load Rolling Load
International Size N N N/m2
(mm) LB N Kg Impact Load Ultimate Load Uniform load 10 10000
Times Times

FS800 600 X 600 X 32/ 40 > 800 > 3560 > 363 > 536 > 10680 > 16100 3650 2670

FS1000 600 X 600 X 32/ 40 > 1000 > 4450 > 450 > 670 > 13350 > 23000 4450 3560

FS1250 600 X 600 X 32/ 40 > 1250 > 5560 > 567 > 780 > 16680 > 33000 5560 4450

FS1500 600 X 600 X 32/ 40 > 1500 > 6660 > 680 > 1005 > 19980 > 34500 6675 5340

sMac Corporation 10
FINISHED
FACTORY

PANELS
Steel Encasuled

BARE PANELS
FACTORY
Wood core
Raised Access

RAISED FLOOR
OUTDOOR
OUTDO
DATA CENTER
PERFORATEDD

PRODUCTS
CLEANROOM
PRODUCTS
DATA CENTER
PRODUCTS
Introduction
uction of Products
Advanced d technology, imported high quality
chipboard d base
b material.
i l

ES
ACCESORIES
Tile could be HPL or PVC ceramics (granite).
Four sides; conductive regular.
Bottom panel; aluminum foil or galvanized steel.
Stringer; pressure forming and conductive tile
cover, lead screw could adjust height.

INSTALLATION
PROCEDURES
Characteristics
s(IGHQUALITYCHIPBOARDPANELENCAPSULATEDBYGALVANIZEDSTEELS
s,IGHTWEIGHTBUTHIGHLOADINGCAPACITY
s3OUND PROOFINGANDGOODSEALING
s.ICEAPPEARANCE
JOB REFERENCE/
ACCESS FLOOR
COMPONENTS
s0ANELCOULDBEWITHORWITHOUTCORNERLOCKHOLE.
FLOOR SYSTEMS

T e chni c a l S p e c i f i c at i o n
N
Concentrated Load Rolling Load
N/m2
USER’S GUIDE

International Size N N
(mm) LB N Kg Impact Load Ultimate Load Uniform load 10 10000
Times Times

FS800 600 X 600 X 32 > 800 > 3650 > 363 > 536 > 10680 > 16100 3560 2670

FS1000 600 X 600 X 32/ 40 > 1000 > 4450 > 450 > 670 > 13350 > 23000 4450 3560

FS1250 600 X 600 X 32/ 40 > 1250 > 5560 > 567 > 780 > 16680 > 33000 5560 4450
INSPECTION/

CUSTOMERS
QUALITY

VALUED

sMac Corporation 11
OUTDOOR RAISED
ACCESS FLOOR

Introduction of Products

Characteristics
sMac pedetal in polypropylene is height-adjustable from 110mm to 1040mm. It has great stability
on structure. Because of material physical property, the pedstal can stand weather extremes, chemical
corrosion and UV radiation.
Numerous accessories are available to allow the pedestals to match all kinds of material: tiles, boards,
decking, pipes, utility ducts.

Te chni c a l S pe c if i cati o n

Product Outdoor pedestal Series No. Height(mm)

Brand sMac 1 110-160

Material Polypropylene 2 190-270

Head Diameter 110mm 3 270-380

Coupler Diameter 95mm 4 350-490

Base Diameter 205mm 5 430-600

Equaliser Thickness 4mm 6 510-710

Load Ability 3T 7 590-820

Slope Corrector Range 0-5% 8 670-930

9 750-1040

sMac Corporation 12
FINISHED
FACTORY

PANELS
Adjustable

BARE PANELS
destal

FACTORY
RAISED FLOOR
OUTDOOR
DATA CENTER
PERFORATED

PRODUCTS
CLEANROOM
PRODUCTS
DATA CENTER
PRODUCTS
ACCESORIES
INSTALLATION
PROCEDURES
JOB REFERENCE/
ACCESS FLOOR
COMPONENTS

Te chni c a l S p e c if i cati o n
FLOOR SYSTEMS

Product Outdoor pedestal Series No. Height(mm)

Brand sMac 1 36-51

Material Polypropylene 2 52-82

Head Diameter 150mm 3 82-135

Coupler Diameter 115m 4 133-225


USER’S GUIDE

Base Diameter 190mm 5 189-293

Load Ability 3T 6 260-365

Slope Corrector Range 0~5% 7 364-507

8 471-651

9 576-795
INSPECTION/

CUSTOMERS
QUALITY

VALUED

sMac Corporation 13
DATA CENTER
PRODUCTS
The
Th combination
bi ti off ventilated
til t d floor
fl iis similar
i il tot that
th t off the
th
antistatic all-steel floor in structure, but its enclosed space is of no
foaming filler. There are punched vents on the upper and lower
steel plates of the floor as well as well on the veneer. The ventilated
floor used with the all-steel access floor is applicable to the sties
with ventilation requirements for the underneath of floor.
The ventilation rate of floor is 20%-45%

AS1000-TFD Ventilation coefficient: 20%


Quantity of ventilation holes: 27x34

AS800-TFB Ventilation coefficient: 20%


Quantity of ventilation holes: 36x36

AS800-TFC Ventilation coefficient: 30%


Quantity of ventilation holes: 24x24

AS1000-TFE Ventilation coefficient: 36%


Quantity of ventilation holes: 8x16

sMac Corporation 14
System
Temperature Control Fan

sMac Corporation
15
QUALITY
JOB REFERENCE/ PERFORATED FACTORY
INSPECTION/ USER’S GUIDE FLOOR SYSTEMS INSTALLATION ACCESORIES DATA CENTER CLEANROOM OUTDOOR FACTORY
ACCESS FLOOR DATA CENTER FINISHED
VALUED PROCEDURES PRODUCTS PRODUCTS RAISED FLOOR BARE PANELS
COMPONENTS PRODUCTS PANELS
CUSTOMERS
Cleanroom Products

Alum
min
nium grating panel

600mm

600mm

Name Material Type Model


(

60A
Solid Panal 60SA
60NA
60AP
Aluminum Die-Cast 600x600
SMAC FLOOR aluminum mm Perforated 60SAP
60 NAP
Grating 60G

sMac Corporation 16
FINISHED
FACTORY

PANELS
Aluminiu
um solid panel

600mm

BARE PANELS
FACTORY
600mm

RAISED FLOOR
OUTDOOR
DATA CENTER
PERFORATED

PRODUCTS
Aluminiu
um perforated panel

CLEANROOM
PRODUCTS
600mm

DATA CENTER
PRODUCTS
600mm

ACCESORIES
INSTALLATION
PROCEDURES
Dimention Weight Central Load & Curvature
(Baseplate only) (Baseplate only)
mm Kg Load (N) Curvature (mm max)
JOB REFERENCE/
ACCESS FLOOR
COMPONENTS

600 x 600 x 43/45 8.5 6000


600 x 600 x 43/45 11.0 10000
FLOOR SYSTEMS

600 x 600 x 43/45 14.5 15000 2.0


600 x 600 x 43/45 7.8, 8.0, 8.3 5000
600 x 600 x 43/45 10.0, 10.2, 10.4 9000
USER’S GUIDE

600 x 600 x 43/45 14.2 14000


600 x 600 x 43/45 8.1 5000
INSPECTION/

CUSTOMERS
QUALITY

VALUED

sMac Corporation 17
sMac Corporation 18
F l o o r s
-
4
-
sMac Corporation
y o u

sMac Corporation 19
QUALITY
JOB REFERENCE/ PERFORATED FACTORY
INSPECTION/ USER’S GUIDE FLOOR SYSTEMS INSTALLATION ACCESORIES DATA CENTER CLEANROOM OUTDOOR FACTORY
ACCESS FLOOR DATA CENTER FINISHED
VALUED PROCEDURES PRODUCTS PRODUCTS RAISED FLOOR BARE PANELS
COMPONENTS PRODUCTS PANELS
CUSTOMERS
Perforated Panel

HPL Panel

Grommet

Step Pedestal

Facia

sMac Corporation 20
Stringer
Cable Tray
Carpet tile

Bare Panel

sMac Corporation 21
QUALITY
JOB REFERENCE/ PERFORATED FACTORY
INSPECTION/ USER’S GUIDE FLOOR SYSTEMS INSTALLATION ACCESORIES DATA CENTER CLEANROOM OUTDOOR FACTORY
ACCESS FLOOR DATA CENTER FINISHED
VALUED PROCEDURES PRODUCTS PRODUCTS RAISED FLOOR BARE PANELS
COMPONENTS PRODUCTS PANELS
CUSTOMERS
ACCESSORIES

sMac Corporation 22
FINISHED
FACTORY

PANELS
BARE PANELS
Installation

FACTORY
Procedures

RAISED FLOOR
OUTDOOR
Bond the supporting leg, and
1 Moving in parts 2 Draw the chalk line 3 adjust thehorizontal position

DATA CENTER
PERFORATED

PRODUCTS
CLEANROOM
PRODUCTS
Move the panels, frames, supporting legs and Determine the position of the supporting leg Bond the supporting leg at the intersection
other members into the construction site. on cleaned ground using the intersection points point of the chalk line with polyurethane
of the chalk line according to the distribution bonding agent, then secure the fixing support
map (shop drawing), i.e., “draw chalk line”. at the same horizontal position with the
adjustable nut and thereby secure the nut and
the screw for the fixing support onto the pillar.

DATA CENTER
PRODUCTS
4 Install the panel 5 Install the frame 6 Complete the installation

ACCESORIES
INSTALLATION
PROCEDURES
Place the panel on the supporting leg, install Measure the dimension of the frame part and, Where necessary, you may us an additional
the panel while making fine adjustment. after machining the floor panel, install the cut reinforcing frame at the cut-in point of the
You also need to the estimate the potential panel. cable outlet. Correct any deviation in the side
exposure to temperature changes and leave drain and joint of the floor tile system and
certain spacing. adjust the horizontal status of the installation
position before completing the installation. JOB REFERENCE/
ACCESS FLOOR
COMPONENTS
FLOOR SYSTEMS

Laser levelling adjustment


USER’S GUIDE
INSPECTION/

CUSTOMERS
QUALITY

VALUED

sMac Corporation 23
JOB REFERENCES

BT
S,
HA
YA

BA
EK

NG
LA

KO
T
PH

K
NA
RA

TI
O

O
ST

NA
AT

L
IO

M
N

US
EU
M

M
AH
AS
AR
AK
HA
M
UN
IV
ER
SI
TY
NG
SU
M
SA

TY
SI
IV ,
ER
UN TRY
RN TIS
KO EN
NG D
O OF
AL Y
UL ULT
CH AC
F

sMac Corporation 24
Components
TECHNICAL

Raised Access Floor


SPECIFICATIONS

pvc stair nosing


pvc perimeter skirting

mdf, connection step with HPL anti-static


mdf, connection facia with HPL anti-static
mdf, connection ramp with anti-slip black rubber

sMac Corporation 25
QUALITY
JOB REFERENCE/ PERFORATED FACTORY
INSPECTION/ USER’S GUIDE FLOOR SYSTEMS INSTALLATION ACCESORIES DATA CENTER CLEANROOM OUTDOOR FACTORY
ACCESS FLOOR DATA CENTER FINISHED
VALUED PROCEDURES PRODUCTS PRODUCTS RAISED FLOOR BARE PANELS
COMPONENTS PRODUCTS PANELS
CUSTOMERS
FLOOR SYSTEMS
200 mm

CORNER LOCK SYSTEM 45 mm

CLIENT

aluminium head pedestal code height quantity

adjustable pedestal alu10cm 80/120 mm 50 pcs/box


range ± 25mm alu15cm 130/170 mm
base 100x100 mm alu20cm 180/220 mm

sMac Corporation 26
FINISHED
FACTORY

PANELS
1500mm

BOLTED STRINGER SYSTEM 50 mm

BARE PANELS
FACTORY
RAISED FLOOR
OUTDOOR
DATA CENTER
PERFORATED

PRODUCTS
CLEANROOM
PRODUCTS
DATA CENTER
PRODUCTS
ACCESORIES
INSTALLATION
PROCEDURES
Open section stringer dimension(W x H x L) 50 pcs/box
made with galvanized 21 x 32 x 570 mm
steel.
JOB REFERENCE/
ACCESS FLOOR
COMPONENTS

flat head pedestal code height quantity

adjustable pedestal ste10cm 80/120 mm *maybe adjusted


FLOOR SYSTEMS

range ± 25mm alu15cm 130/170 mm upon the height


base 100 x100mm alu20cm 180/220 mm
*maybe adjusted ste25cm 230/270 mm
upon the height ste30cm 280/320 mm
ste35cm 330/370 mm
ste40cm 380/420 mm
USER’S GUIDE

... ...
.... ....
.... ....
Ste100cm 980/1020 mm
INSPECTION/

CUSTOMERS
QUALITY

VALUED

sMac Corporation 27
USER’S GUIDE
Instruction manual of each product will be given after installation. Before use, please read the instruction manual
carefully for its proper use and care, and keep this manual for ready reference.

1.Remodeling strictly prohibited


Installation is done according to the conditions that provided.
d.
(Point us use and weight of machine) Remodeling such as,,
opening holes and cutting will affect the strength of panel..
Please contact us if remodeling is needed.

Do not take off the surface materials on the floor. (such as carpet tiles and other tiles)

2.Avoid Shock
2.A
Pan
Panels are designed to withstand the load that written in
the product specification. Do not drop any heavy object or
jump on the panel.
jum
This caused deformation or damage to the panel and pedestal.

3.Water
When a large amount of water is spilt, remove the panel and dry it immediately. Lowering of the adhesive force of
pedestals, electric leakage and rust are caused by water.

4.Removing the panels


Do not remove the panel except when necessary. Please be careful the power cable e and
telephone line under the panel when removing the panel while wiring work.
Carefully handle the removed panel, and ensure the panel is in same direction to
the original position. Please refer to instruction manual about method of handling
the panel. (Removing, level adjust etc.)

Do not leave the panel opened, it will lead to an unexpected accident.


dent.
Use fence to surround it to prevent accident.

5.Indoor ventilation
Condensation occurs in a humid room or a long unused room. Ensure sufficient ventilation to prevent rust and
electric leakage.

6.Wiring
Make adequate room between cables to prevent electric leakage.

sMac Corporation 28
FINISHED
FACTORY

PANELS
Installation Warning

BARE PANELS
FACTORY
Load limitation is depending
p on the type of panel, please refer to the instruction manual.

1.Installation (Moving)
1.I
・W
・When moving a heavy object on top of the panel, there are cases that the load

RAISED FLOOR
OUTDOOR
of its
i own weight or more is applied to the panel, and this will damage the panel
and pedestal. Please refer the protection method that written in instruction manual.
・Due to the floor surface is soft, please cover the floor surface when using a trolley.
・D
・D
・Do not drag the machine on the floor, it may damage the tiles covering the panels..
・U
・Use trolley carefully as not to occur sudden shock.

DATA CENTER
PERFORATED

PRODUCTS
2.Installation of heavy loads
・Installing a heavy objects on a small area of raised floor panel will occur deflection.
n.
To prevent deformation and damage, additional strength is needed.

CLEANROOM
PRODUCTS
・Please install heavy object carefully to avoid any sudden shock. Sudden shock
will cause deformation or damage to the panels or pedestals.

Maintenance

DATA CENTER
PRODUCTS
1.Regular maintenance 3.Caring for antistatic tiles
For long-term high performance of the Raised ・Apply antistatic wax before using the tiles. In
Floor, regular maintenance (once in 2 or 3 years) standard installation, antistatic wax is not applied
is needed. Please contact us for details. at the completion of installation. Antistatic wax

ACCESORIES
protects the tiles from damage or stains. Use
2.Caring for carpet tiles antistatic wax specified by the manufacturer.
・Clean the carpet tiles with a vacuum cleaner The use of other products causes lowering in
for daily care. antistatic effect.
・When coffee or sauce is spilled on the carpet, (E.g.) NON STACK by Rinrei Wax Co.,Ltd.,

INSTALLATION
PROCEDURES
wipe it immediately with a wet rag. ELEX by CxS Corporation (formerly Johnson
・If the stains could not be remove, wash the Company, Limited)
carpet tiles with neutral detergent diluted with ・For daily care, clean the antistatic tiles with a vacuum
water. Dry it adequately before using them cleaner and then wipe them with a rag.
again. Replace new carpet if become seriously ・When using cleaner and remover, move the panels
JOB REFERENCE/

elsewhere.
ACCESS FLOOR
COMPONENTS
dirty.
・If use carpet tiles that not suggested by us, The solvent may cause
caus rust on the p pedestal.
please refer to the company’s manual.
FLOOR SYSTEMS

Change of layout and others

・In case of minor changes, please follow the instruction manual.


・If area is expanded during renovation, extra outlet boxes and reinforcement work will be needed.
USER’S GUIDE

Please contact us.


・Please contact us when panel cutout construction associated with the arrangement change of equipment
is needed.
・As for the accessories including outlet boxes, please read manual of the product.
・Regular maintenance contract is provided. Please contact us for the details. *Please contact our sales
department if you have any questions about how to use.
INSPECTION/

CUSTOMERS
QUALITY

VALUED

sMac Corporation 29
QUALITY
INSPECTION

MacLev
sMac Corporation 30
F l o o r s
-
4
-
y o u
sMac Corporation
VALUED

sMac Corporation 31
CUSTOMERS

QUALITY
JOB REFERENCE/ PERFORATED FACTORY
INSPECTION/ USER’S GUIDE FLOOR SYSTEMS INSTALLATION ACCESORIES DATA CENTER CLEANROOM OUTDOOR FACTORY
ACCESS FLOOR DATA CENTER FINISHED
VALUED PROCEDURES PRODUCTS PRODUCTS RAISED FLOOR BARE PANELS
COMPONENTS PRODUCTS PANELS
CUSTOMERS
Tel. +(66) 2 408 7765
Fax. +(66)2 408 7189
Hotline : 086 318 1864
E-Mail: [email protected]
w w w. s m a cco r p o rat i o n . co. t h
388/7 Ratchaphruek Rd. Bangvak, Phasi Chareon
Bangkok 10160 THAILAND.

sMac Corporation
F l o o r s - 4 - y o u

MacLev

You might also like