Model: A100: Flushing Ring

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

Flushing ring

Model : A100
Spec. sheet no. AD01-01

Service intended
Flushing Ring is designed to be used with a flange,
pancake, or inline diaphragm seals.
The flushing ring have two lateral NPT ports to flush out
the collected process medium adjacent to the diaphragm
seal. A flushing ring is great for use with diaphragm seal
model numbers A100, when there is a potential of the
deposits from the process medium blocking access to the
diaphragm seals. The flushing ring is designed to be
sandwiched between the process flange and the
diaphragm seal. Material gathered in front of the
diaphragm could be flushed out through the flushing
bore holes. The flushing ring also can be used to vent the
process. Several standard widths and sizes are available
to fit different process conditions and applications.

Process connection
ANSI ½" to 4" per ASME

Main order Ordering information

1. Base model 5. Nipple and plug connection type


A100 Flusing ring A One - With plug D Two - With nipple
B Two - With plug Z Other
2. Flushing ring material C With plug and nipple
BX 304SS
DX 304L SS 6. Isolation valve material
CX 316SS
A None
EX 316L SS, ¼" NPT(M)
B 316SS and 316L SS
LX Monel, ⅜" NPT(M)
C Monel
KX Hastelloy-C, ½" NPT(M)
D Hastelloy-C
RX 304SS with PTFE coating
E Teflon
SX 316SS with PTFE coating
Z Other
51 316L SS with PTFE coating
53 Teflon
7. Valve gasket material
54 PVC
1 Teflone
ZZ Other
2 Graphite
3. Process connection type
XXX Refer to process connection type table 8. Flange gasket material
00 None
4. Plug connection size
10 Teflon
0 One - ¼" NPT(F) 4 Two - ⅜" NPT(F) 20 Spiral wound
1 One - ⅜" NPT(F) 5 Two - ½" NPT(F) 30 Oval gasket (Only RTJ)
2 One - ½" NPT(F) 9 Other
3 Two - ¼" NPT(F)

1 2 3 4 5 6 7 8
Sample
A100 BX XXX 0 A A 1 00 ordering code

© WISE Control Inc. All rights reserved. ALL PRODUCT, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE WITHOUT
NOTICE TO IMPROVE RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE.

A100_01
Process connection type table - 7 th , 8th and 9th characters

7 th character 8 th , 9 th character
Code Connection size Flange size

E ½" (15A) AC B16.5 Class 150 RF


F ¾" (20A) AE B16.5 Class 150 FF
G 1" (25A) AF B16.5 Class 300 RF
H 1¼" (32A) AH B16.5 Class 300 FF
J 1½" (40A) AJ B16.5 Class 600 RF
K 2" (50A) AL B16.5 Class 600 FF
L 2½" (65A) KL JIS 10K RF
M 3" (80A) KN JIS 10K FF
N 4" (100A) KP JIS 20K RF
Z Other KR JIS 20K FF
KC JIS 30K RF
KU JIS 30K FF
AS B16.5 Class 900 RF
KD JIS 40K RF
KV JIS 40K FF
A8 B16.5 Class 150 RTJ
A9 B16.5 Class 300 RTJ
AV B16.5 Class 600 RTJ
AT B16.5 Class 1,500 RF
AN B16.5 Class 1,500 FF
AX B16.5 Class 1,500 RTJ
AY B16.5 Class 2,500 RTJ
ZZ Other