Intro PT 1 EN
Intro PT 1 EN
PROTECT 1.
April 2012
DATA&IT, SBU C-UPS, PM/SR
CONTENTS
A CLASSIFICATION 3
B PRODUCT HIGHLIGHTS 8
C SUMMARY 25
2
A-
CLASSIFICATION
CLASSIFICATION ACC. TO
- AEG΄S UPS PRODUCT PORTFOLIO
- IT΄S APPLICATION ORIENTED USE
- UPS PRODUCT NORM IEC 62040-3
CLASSIFICATION ACC. TO
4
CLASSIFICATION ACC. TO
PROTECT D.
PROTECT D. 1000 / 1500 / 2000 / 3000 / 6000 / 10000 [VA]
1-phase Output
On-Line / VFI - technology
PROTECT 1. PROTECT 1.
10000 / 15000 / 20000 [VA]
1-phase Output
On-Line / VFI - technology
PROTECT 1.M
PROTECT 1.M
scalable: 4000 up to 24000 [VA]
1-phase Output
On-Line modular / VFI - technology
Power [ kVA ] 0.5 0.7 1 1.5 2 3 4 6 8 10 12 16 20 24
5
CLASSIFICATION ACC. TO
Home, SoHo
600 VA 500 to 1400 VA
Comprehensive protection Protects PCs, workstations
for all Multimedia equipment. and phone systems.
Compact UPS
PROTECT 1. PROTECT 1.M PROTECT 2.33 2.0 PROTECT 3.M 2.0 PROTECT BLUE.
Medium High
Data Centre
Power UPS
6
CLASSIFICATION ACC. TO
4. Undervoltage continuous VI
PROTECT 1.
Classification 2
Voltage
5. Overvoltage continuous Line-Interactive
Independent
Limited protection
6. Transients (Surge) < 4 ms Classification 1
via UPS
(extended protection
VFI recommended (10.))
7. Frequency variations sporadic
(true) Online
Voltage +
8. Voltage distortion (Burst) periodic real Double-
see as well 10.
Frequency
Independent Conversion
9. Voltage harmonics continuous
7
B-
PRODUCT
HIGHLIGHTS
POWER STEPS
PROTECT 1.
2 nd generation Double-Conversion UPS
DSP controlled n+x technology
6 0 0 0 0 VA
4 0 0 0 0 VA
20000 VA
4 5 0 0 0 VA
3 0 0 0 0 VA
15000 VA
3 0 0 0 0 VA
2 0 0 0 0 VA
10000 VA
9
PRODUCT INFO – FEATURES
FEATURES
10
PRODUCT INFO – FEATURES
POWER RANGE OVERVIEW – FEATURES
11
PRODUCT INFO – CONNECTIONS
PROTECT 1.200 (20kVA ) – CONNECTIONS
11 PE-/earthing terminals
12 Macrolon cover plate Extract of the operating instructions
12
LESS SPACE REQUIREMENT
PROTECT 1. 570 mm
10 / 15 / 20 kVA
13
PRODUCT INFO – AUTONOMY TIME DATA ( I )
AUTONOMY TIME DATA
14
PRODUCT INFO – AUTONOMY TIME DATA ( II )
AUTONOMY TIME DATA AT PART LOAD
< < < < Autonomy time at > > > >
PROTECT 1. at part load
25% load 50% load 75% load 100% load
PROTECT 1.100 [ 10 kVA ] = 1750 W = 3500 W = 5250 W = 7000 W
with 1 x PROTECT 1.100 BP 83 min. 42 min. 24 min. 16 min.
with 2 x PROTECT 1.100 BP 145 min. 97 min. 56 min. 42 min.
with 3 x PROTECT 1.100 BP 166 min. 134 min. 98 min. 60 min.
with 1 x PROTECT 1. BP 20 89 min. 47 min. 29 min. 19 min.
with 2 x PROTECT 1. BP 20 216 min. 103 min. 69 min. 47 min.
with 3 x PROTECT 1. BP 20 329 min. 177 min. 105 min. 78 min.
with 4 x PROTECT 1. BP 20 472 min. 243 min. 155 min. 103 min.
with 5 x PROTECT 1. BP 20 591 min. 312 min. 204 min. 138 min.
PROTECT 1.150 [ 15 kVA ] = 2625 W = 5250 W = 7875 W = 10500 W
with 1 x PROTECT 1. BP 20 58 min. 29 min. 16 min. 10 min.
with 2 x PROTECT 1. BP 20 125 min. 68 min. 42 min. 29 min.
with 3 x PROTECT 1. BP 20 216 min. 103 min. 69 min. 47 min.
with 4 x PROTECT 1. BP 20 295 min. 153 min. 90 min. 68 min.
with 5 x PROTECT 1. BP 20 357 min. 202 min. 117 min. 85 min.
PROTECT 1.200 [ 20 kVA ] = 3500 W = 7000 W = 10500 W = 14000 W
with 1 x PROTECT 1. BP 20 42 min. 19 min. 10 min. 6 min.
with 2 x PROTECT 1. BP 20 89 min. 47 min. 29 min. 19 min.
with 3 x PROTECT 1. BP 20 152 min. 62 min. 48 min. 34 min.
with 4 x PROTECT 1. BP 20 216 min. 103 min. 69 min. 47 min.
with 5 x PROTECT 1. BP 20 276 min. 138 min. 86 min. 63 min.
15
PRODUCT INFO – COMPONENT DIAGRAM
COMPONENT DIAGRAM
Component
diagram :
16
PRODUCT HIGHLIGHT – EFFICIENCY
EFFICIENCY
Load [ % ]
17
PRODUCT INFO – OPERATIONAL BEHAVIOUR
BYPASS TECHNOLOGY (SBS)
iINV
iM
uL
18
PRODUCT INFO – OPERATIONAL BEHAVIOUR
INVERTER CONTROL PROCESS (PWM)
uD u12
u +
0
uR t
load / demand
comparison u L with u R
19
PRODUCT HIGHLIGHT – PROTECT 1.BP20
BATTERY CABINET PROTECT 1.BP20
PROTECT 1. BP 20
10 / 15 / 20 kVA
Well-build terminals
for 35mm² wire connection/ pole
Batteries on sliders,
for easy future battery exchange
High-performance batteries
(design life 10-12 years acc. to EUROBAT)
20
PRODUCT INFO – PROTECT 1.BP20
TRANSPORT & UNLOADING
21
PRODUCT HIGHLIGHT – PARALLEL OPERATION ( I )
PARALLEL OPERATION (ILLUSTRATION)
PROTECT
1.100 or
1.150 or
1.200
up to 3 units in parallel
Parallel field incl. external manual bypass switch
to increase output power
and/ or to provide redundancy Single - phase output
22
PRODUCT INFO – PARALLEL OPERATION ( II )
PARALLEL OPERATION (REDUNDANCY LEVELS)
23
PRODUCT INFO – REAR VIEW
REAR VIEW
PROTECT 1.150
PROTECT 1.200
Coooling fan Cooling fan
increase of power
and/ or active redundancy
Input
Battery
breaker
connection
24
C-
CONCLUSION
CONCLUSION
COMPETITIVENESS – CONCLUSION
26