EFFICIENCY AND NOISE

LEVEL CERTIFICATIONS

Anex Cougar VTE Bronze 600W

Lab ID#: CG60001686


Report: 20PS1686A
Receipt Date: Jul 16, 2020
Test Date: Jul 20, 2020 Report Date: Jul 21, 2020

DUT INFORMATION DUT SPECIFICATIONS

Brand Cougar Rated Voltage (Vrms) 100-240

Manufacturer (OEM) HEC Rated Current (Arms) 10-6

Series VTE Bronze Rated Frequency (Hz) 50-60

Model Number CGR BS-600 Rated Power (W) 600

Serial Number ZBJ01VE60003061 Type ATX12V

DUT Notes 120mm Rifle Bearing Fan


Cooling
(EJA 1202512SEHN)

Semi-Passive Operation ✗

Cable Design Fixed cables

POWER SPECIFICATIONS

Rail 3.3V 5V 12V 5VSB -12V

Amps 16 20 45 2.5 0.3


Max. Power
Watts 150 540 12.5 3.6

Total Max. Power (W) 600

CABLES AND CONNECTORS

Native Cables

Description Cable Count Connector Count (Total) Gauge In Cable Caps

ATX connector 20+4 pin (450mm) 1 1 18-22AWG No

4+4 pin EPS12V (610mm) 1 1 18AWG No

6+2 pin PCIe (460mm+120mm) 1 2 18AWG No

SATA (450mm+120mm+120mm) / 4-pin Molex (+120mm) 2 6/2 18AWG No

Modular Cables

AC Power Cord (1080mm) - C13 coupler 1 1 18AWG -

All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics PAGE 1/16
› The link to the original test results document should be provided in any case

Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient www.cybenetics.com [email protected]
and silent power supplies are promoted 4004 MESA GEITONIA, LIMASSOL, CYPRUS
EFFICIENCY AND NOISE
LEVEL CERTIFICATIONS

Anex Cougar VTE Bronze 600W

General Data -
Manufacturer (OEM) HEC

PCB Type Single Sided

Primary Side -
Transient Filter 4x Y caps, 2x X caps, 2x CM chokes

Inrush Protection NTC Thermistor Cantherm MF72 2.5D15

Bridge Rectifier(s) 1x  GBJ 1506 (600V, 15A @ 100°C)

APFC MOSFETs 2x China Wind CWS20N60AF (600V, 13A @ 100°C, Rds(on): 0.19Ohm)

APFC Boost Diode 1x STMicroelectronics STTH8S06D (600V, 8A)

Bulk Cap(s) 1x CapXon (420V, 270uF, 2,000h @ 85°C, LS)

Main Switchers 2x China Wind CWS20N60AF (600V, 13A @ 100°C, Rds(on): 0.19Ohm)

Combo PFC/PWM Controller Champion CM6800UX & CM03X Green PFC Controller

Primary side: APFC, Double-Forward


Topology
Secondary side: Passive Rectification & DC-DC converters

Secondary Side -
2x MHCHXM MBR4E60
+12V & 5V SBRs 2x MHCHXM MBR3E60
2x MHCHXM MBR3E45

DC-DC Converters: 2x China Resources Microelectronics (Chongqing) CRTD045N03L (30V, 72A @ 100°C, Rds(on):
3.3V 4.5mOhm)
PWM Controllers: ANPEC APW7073

Electrolytic: 10x CapXon (2-5,000h @ 105°C, KF), 2x CapXon (2,000h @ 105°C, KM)
Filtering Capacitors
Polymer: 2x CapXon

Supervisor IC EST EST7627A (OCP, OVP, UVP, SCP, PG)

Fan Model EJA 1202512SEHN (120mm, 12V, 0.32A, Rifle Bearing Fan)

5VSB Circuit -
Standby PWM Controller Power Integrations TNY288PG

All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics PAGE 2/16
› The link to the original test results document should be provided in any case

Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient www.cybenetics.com [email protected]
and silent power supplies are promoted 4004 MESA GEITONIA, LIMASSOL, CYPRUS
EFFICIENCY AND NOISE
LEVEL CERTIFICATIONS

Anex Cougar VTE Bronze 600W

RESULTS

Temperature Range (°C /°F) 30-32 / 86-89.6

ErP Lot 6 2010: ✓


ErP Lot 3/6 Ready ErP Lot 6 2013: Partially
ErP Lot 3 2014 & CEC: ✗

(EU) No 617/2013 Compliance ✓

115V 230V

Average Efficiency 83.423% Average Efficiency 85.618%

Efficiency With 10W (≤500W) or 2% (>500W) 64.297 Average Efficiency 5VSB 71.607%

Average Efficiency 5VSB 72.219% Standby Power Consumption (W) 0.0975778

Standby Power Consumption (W) 0.0466416 Average PF 0.978

Average PF 0.987 Avg Noise Output 43.19 dB(A)

Avg Noise Output 43.31 dB(A) Efficiency Rating (ETA) BRONZE

Efficiency Rating (ETA) BRONZE Noise Rating (LAMBDA) S

Noise Rating (LAMBDA) S

TEST EQUIPMENT

Chroma 63601-5 x4
Chroma 63600-2 x2
Electronic Loads
63640-80-80 x20
63610-80-20 x2

AC Sources Chroma 6530, Keysight AC6804B

Power Analyzers N4L PPA1530 x2

Sound Analyzer Bruel & Kjaer 2270 G4

Microphone Bruel & Kjaer Type 4955-A

Data Loggers Picoscope TC-08 x2, Labjack U3-HV x2

Tachometer UNI-T UT372 x2

Digital Multimeter Keysight U1273AX, Fluke 289, Keithley 2015 - THD

UPS CyberPower OLS3000E 3kVA x2

Transformer 3kVA x2
HOLD-UP TIME & POWER OK SIGNAL (230V)

Hold-Up Time (ms) 11.5

AC Loss to PWR_OK Hold Up Time (ms) 9.3

PWR_OK Inactive to DC Loss Delay (ms) 2.2

All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics PAGE 3/16
› The link to the original test results document should be provided in any case

Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient www.cybenetics.com [email protected]
and silent power supplies are promoted 4004 MESA GEITONIA, LIMASSOL, CYPRUS
EFFICIENCY AND NOISE
LEVEL CERTIFICATIONS

Anex Cougar VTE Bronze 600W

EFFICIENCY UNDER HIGH AMBIENT TEMPERATURE


INFO

The PSU`s efficiency under high ambient


temperatures with 115V and 230V input. For this
graph the results of the 10-110% load regulation
table are used

5VSB EFFICIENCY
INFO

This graph depicts the efficiency levels of the 5VSB


rail with 115V and 230V input

All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics PAGE 4/16
› The link to the original test results document should be provided in any case

Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient www.cybenetics.com [email protected]
and silent power supplies are promoted 4004 MESA GEITONIA, LIMASSOL, CYPRUS
EFFICIENCY AND NOISE
LEVEL CERTIFICATIONS

Anex Cougar VTE Bronze 600W

5VSB EFFICIENCY -115V (ERP LOT 3/6 & CEC)

Test # 5VSB DC/AC (Watts) Efficiency PF/AC Volts

0.045A 0.233 0.084


1 66.006%
5.181V 0.353 115.15V

0.090A 0.466 0.145


2 70.713%
5.179V 0.659 115.15V

0.550A 2.839 0.342


3 74.770%
5.160V 3.797 115.15V

1.000A 5.142 0.385


4 71.556%
5.141V 7.186 115.15V

1.500A 7.680 0.408


5 71.329%
5.119V 10.767 115.14V

2.500A 12.687 0.439


6 69.034%
5.074V 18.378 115.14V

5VSB EFFICIENCY -230V (ERP LOT 3/6 & CEC)

Test # 5VSB DC/AC (Watts) Efficiency PF/AC Volts

0.045A 0.233 0.031


1 56.145%
5.181V 0.415 230.42V

0.090A 0.466 0.054


2 63.923%
5.179V 0.729 230.42V

0.550A 2.839 0.215


3 72.019%
5.160V 3.942 230.42V

1.000A 5.142 0.283


4 73.342%
5.141V 7.011 230.42V

1.500A 7.680 0.321


5 72.242%
5.119V 10.631 230.41V

2.500A 12.689 0.359


6 71.262%
5.075V 17.806 230.40V

All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics PAGE 5/16
› The link to the original test results document should be provided in any case

Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient www.cybenetics.com [email protected]
and silent power supplies are promoted 4004 MESA GEITONIA, LIMASSOL, CYPRUS
EFFICIENCY AND NOISE
LEVEL CERTIFICATIONS

Anex Cougar VTE Bronze 600W

115V

All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics PAGE 6/16
› The link to the original test results document should be provided in any case

Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient www.cybenetics.com [email protected]
and silent power supplies are promoted 4004 MESA GEITONIA, LIMASSOL, CYPRUS
EFFICIENCY AND NOISE
LEVEL CERTIFICATIONS

Anex Cougar VTE Bronze 600W

EFFICIENCY GRAPH 115V


INFO

This graph depicts the PSU’s efficiency throughout


its entire operational range. For the generation of
the efficiency and noise graphs we set our loaders
to auto mode through our custom-made software
before trying thousands of possible load
combinations

NOISE GRAPH 115V


INFO

The PSU’s noise in its entire operational range and


under 30-32 °C ambient is depicted in this graph.
The X axis represents the load on the +12V rail(s)
while the Y axis is the load on the minor rails

All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics PAGE 7/16
› The link to the original test results document should be provided in any case

Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient www.cybenetics.com [email protected]
and silent power supplies are promoted 4004 MESA GEITONIA, LIMASSOL, CYPRUS
EFFICIENCY AND NOISE
LEVEL CERTIFICATIONS

Anex Cougar VTE Bronze 600W

VAMPIRE POWER -115V


INFO

This graph is generated by the PPA Standby Power


Analysis software which takes full control of the
power analyzer during the whole procedure. This
application features all of the EN50564 &
IEC62301 test limits for standby power software
testing

All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics PAGE 8/16
› The link to the original test results document should be provided in any case

Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient www.cybenetics.com [email protected]
and silent power supplies are promoted 4004 MESA GEITONIA, LIMASSOL, CYPRUS
EFFICIENCY AND NOISE
LEVEL CERTIFICATIONS

Anex Cougar VTE Bronze 600W

10-110% LOAD TESTS 115V

DC/AC Fan Speed PSU Noise Temps PF/AC


Test # 12V 5V 3.3V 5VSB Efficiency
(Watts) (RPM) (dB[A]) (In/Out) Volts

3.125A 1.979A 1.952A 0.975A 60.001 34.13°C 0.971


1 81.937% 855 21.1
12.290V 5.053V 3.378V 5.128V 73.228 37.52°C 115.12V

7.268A 2.978A 2.944A 1.175A 120.017 34.96°C 0.981


2 85.927% 856 21.1
12.259V 5.042V 3.363V 5.109V 139.674 39.06°C 115.10V

11.789A 3.472A 3.441A 1.375A 180.018 35.63°C 0.986


3 86.635% 859 20.9
12.212V 5.042V 3.355V 5.091V 207.789 40.83°C 115.09V

16.343A 3.969A 3.942A 1.577A 240.022 35.70°C 0.988


4 86.390% 1140 30.0
12.165V 5.041V 3.349V 5.072V 277.834 41.66°C 115.08V

20.567A 4.972A 4.947A 1.782A 300.054 36.30°C 0.989


5 85.707% 1436 36.8
12.133V 5.029V 3.337V 5.052V 350.092 42.76°C 115.08V

24.816A 5.980A 5.954A 1.988A 360.008 36.96°C 0.989


6 84.819% 1748 42.0
12.097V 5.019V 3.324V 5.032V 424.441 44.30°C 115.07V

29.063A 6.991A 6.974A 2.196A 419.642 37.49°C 0.990


7 83.778% 2038 47.2
12.061V 5.008V 3.312V 5.011V 500.897 46.11°C 115.05V

33.410A 8.001A 8.005A 2.406A 480.135 37.77°C 0.990


8 82.670% 2174 47.6
12.025V 4.996V 3.298V 4.990V 580.784 47.19°C 115.06V

38.160A 8.513A 8.517A 2.412A 539.481 38.62°C 0.990


9 81.679% 2166 47.5
11.975V 4.993V 3.288V 4.977V 660.489 48.72°C 115.05V

43.029A 9.015A 9.066A 2.522A 600.199 39.74°C 0.991


10 80.536% 2164 47.5
11.922V 4.992V 3.276V 4.958V 745.253 50.62°C 115.04V

48.312A 9.005A 9.088A 2.528A 660.239 40.58°C 0.989


11 79.230% 2159 47.6
11.861V 4.998V 3.268V 4.946V 833.318 52.28°C 115.05V

0.117A 18.001A 18.001A 0.001A 146.955 36.05°C 0.984


CL1 77.391% 1888 43.9
12.530V 4.798V 3.284V 5.114V 189.886 42.03°C 115.13V

44.970A 0.999A 1.000A 1.000A 539.427 39.03°C 0.990


CL2 81.978% 2139 47.9
11.694V 5.170V 3.329V 5.054V 658.013 50.59°C 115.05V

All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics PAGE 9/16
› The link to the original test results document should be provided in any case

Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient www.cybenetics.com [email protected]
and silent power supplies are promoted 4004 MESA GEITONIA, LIMASSOL, CYPRUS
EFFICIENCY AND NOISE
LEVEL CERTIFICATIONS

Anex Cougar VTE Bronze 600W

20-80W LOAD TESTS 115V

DC/AC Fan Speed PSU Noise


Test # 12V 5V 3.3V 5VSB Efficiency PF/AC Volts
(Watts) (RPM) (dB[A])

1.209A 0.492A 0.486A 0.193A 19.991 0.933


1 70.767% 853 21.2
12.276V 5.087V 3.392V 5.171V 28.249 115.15V

2.418A 0.985A 0.975A 0.388A 39.980 0.957


2 79.333% 853 21.2
12.278V 5.075V 3.385V 5.159V 50.395 115.14V

3.630A 1.480A 1.466A 0.583A 60.009 0.970


3 82.727% 853 21.2
12.275V 5.065V 3.380V 5.146V 72.539 115.14V

4.838A 1.976A 1.956A 0.779A 79.958 0.974


4 84.859% 854 21.2
12.270V 5.057V 3.376V 5.134V 94.225 115.12V

RIPPLE MEASUREMENTS 115V

Test 12V 5V 3.3V 5VSB Pass/Fail

10% Load 14.20mV 8.50mV 15.90mV 12.10mV Pass

20% Load 16.00mV 9.50mV 16.50mV 13.10mV Pass

30% Load 17.30mV 10.20mV 16.50mV 15.80mV Pass

40% Load 18.20mV 10.80mV 17.70mV 16.50mV Pass

50% Load 21.50mV 12.40mV 18.10mV 17.70mV Pass

60% Load 24.70mV 13.50mV 18.70mV 21.30mV Pass

70% Load 30.70mV 14.60mV 19.40mV 22.60mV Pass

80% Load 36.00mV 16.10mV 25.40mV 23.70mV Pass

90% Load 39.10mV 17.50mV 26.80mV 24.80mV Pass

100% Load 45.70mV 20.00mV 28.70mV 28.70mV Pass

110% Load 51.90mV 21.30mV 29.70mV 30.60mV Pass

Crossload1 26.30mV 17.40mV 34.50mV 17.10mV Pass

Crossload2 54.20mV 14.20mV 20.10mV 25.20mV Pass

All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics PAGE 10/16
› The link to the original test results document should be provided in any case

Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient www.cybenetics.com [email protected]
and silent power supplies are promoted 4004 MESA GEITONIA, LIMASSOL, CYPRUS
EFFICIENCY AND NOISE
LEVEL CERTIFICATIONS

Anex Cougar VTE Bronze 600W

230V

All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics PAGE 11/16
› The link to the original test results document should be provided in any case

Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient www.cybenetics.com [email protected]
and silent power supplies are promoted 4004 MESA GEITONIA, LIMASSOL, CYPRUS
EFFICIENCY AND NOISE
LEVEL CERTIFICATIONS

Anex Cougar VTE Bronze 600W

EFFICIENCY GRAPH 230V


INFO

This graph depicts the PSU’s efficiency throughout


its entire operational range. For the generation of
the efficiency and noise graphs we set our loaders
to auto mode through our custom-made software
before trying thousands of possible load
combinations

NOISE GRAPH 230V


INFO

The PSU’s noise in its entire operational range and


under 30-32 °C ambient is depicted in this graph.
The X axis represents the load on the +12V rail(s)
while the Y axis is the load on the minor rails

All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics PAGE 12/16
› The link to the original test results document should be provided in any case

Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient www.cybenetics.com [email protected]
and silent power supplies are promoted 4004 MESA GEITONIA, LIMASSOL, CYPRUS
EFFICIENCY AND NOISE
LEVEL CERTIFICATIONS

Anex Cougar VTE Bronze 600W

VAMPIRE POWER -230V


INFO

This graph is generated by the PPA Standby Power


Analysis software which takes full control of the
power analyzer during the whole procedure. This
application features all of the EN50564 &
IEC62301 test limits for standby power software
testing

All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics PAGE 13/16
› The link to the original test results document should be provided in any case

Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient www.cybenetics.com [email protected]
and silent power supplies are promoted 4004 MESA GEITONIA, LIMASSOL, CYPRUS
EFFICIENCY AND NOISE
LEVEL CERTIFICATIONS

Anex Cougar VTE Bronze 600W

10-110% LOAD TESTS 230V

DC/AC Fan Speed PSU Noise Temps PF/AC


Test # 12V 5V 3.3V 5VSB Efficiency
(Watts) (RPM) (dB[A]) (In/Out) Volts

3.125A 1.979A 1.955A 0.976A 60.009 35.58°C 0.909


1 83.237% 857 21.1
12.288V 5.053V 3.379V 5.127V 72.094 39.02°C 230.37V

7.274A 2.976A 2.941A 1.175A 120.041 35.96°C 0.956


2 87.418% 860 20.9
12.254V 5.043V 3.365V 5.107V 137.319 40.17°C 230.37V

11.793A 3.472A 3.442A 1.376A 180.048 36.83°C 0.971


3 88.314% 862 20.9
12.210V 5.041V 3.356V 5.088V 203.872 41.75°C 230.36V

16.348A 3.971A 3.942A 1.579A 240.056 36.91°C 0.978


4 88.202% 1208 31.5
12.163V 5.039V 3.349V 5.069V 272.166 42.43°C 230.36V

20.579A 4.974A 4.946A 1.783A 300.093 37.55°C 0.982


5 87.752% 1468 37.4
12.128V 5.028V 3.336V 5.049V 341.978 43.73°C 230.36V

24.827A 5.981A 5.960A 1.990A 360.054 37.64°C 0.984


6 87.057% 1780 43.6
12.093V 5.017V 3.324V 5.027V 413.586 44.80°C 230.35V

29.080A 6.994A 6.979A 2.198A 419.769 38.74°C 0.986


7 86.270% 2049 46.7
12.058V 5.006V 3.311V 5.006V 486.578 47.52°C 230.34V

33.420A 8.004A 8.008A 2.407A 480.217 39.54°C 0.986


8 85.477% 2180 47.8
12.024V 4.994V 3.297V 4.986V 561.809 49.26°C 230.34V

38.178A 8.514A 8.519A 2.413A 539.542 39.61°C 0.987


9 84.778% 2167 47.5
11.971V 4.993V 3.287V 4.973V 636.418 50.08°C 230.32V

43.039A 9.021A 9.068A 2.524A 600.253 40.40°C 0.988


10 83.924% 2166 47.5
11.920V 4.990V 3.276V 4.955V 715.232 51.52°C 230.32V

48.334A 9.010A 9.091A 2.530A 660.274 40.98°C 0.989


11 83.085% 2161 47.6
11.856V 4.997V 3.267V 4.942V 794.696 52.84°C 230.31V

0.118A 17.999A 18.000A 0.001A 146.900 37.68°C 0.969


CL1 78.892% 1781 43.6
12.529V 4.795V 3.284V 5.114V 186.203 43.58°C 230.35V

45.009A 1.002A 1.000A 1.000A 539.759 40.64°C 0.987


CL2 85.090% 2138 47.9
11.691V 5.170V 3.325V 5.054V 634.339 51.83°C 230.31V

All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics PAGE 14/16
› The link to the original test results document should be provided in any case

Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient www.cybenetics.com [email protected]
and silent power supplies are promoted 4004 MESA GEITONIA, LIMASSOL, CYPRUS
EFFICIENCY AND NOISE
LEVEL CERTIFICATIONS

Anex Cougar VTE Bronze 600W

20-80W LOAD TESTS 230V

DC/AC Fan Speed PSU Noise


Test # 12V 5V 3.3V 5VSB Efficiency PF/AC Volts
(Watts) (RPM) (dB[A])

1.210A 0.492A 0.486A 0.193A 19.998 0.722


1 71.455% 861 20.9
12.271V 5.088V 3.393V 5.170V 27.987 230.37V

2.418A 0.986A 0.975A 0.388A 39.988 0.857


2 80.350% 859 20.9
12.275V 5.075V 3.387V 5.158V 49.767 230.37V

3.632A 1.481A 1.463A 0.583A 60.018 0.908


3 84.042% 858 20.9
12.272V 5.065V 3.381V 5.145V 71.414 230.37V

4.839A 1.977A 1.956A 0.780A 79.966 0.932


4 85.842% 858 20.9
12.267V 5.057V 3.377V 5.132V 93.155 230.37V

RIPPLE MEASUREMENTS 230V

Test 12V 5V 3.3V 5VSB Pass/Fail

10% Load 14.10mV 8.30mV 14.80mV 11.90mV Pass

20% Load 14.90mV 9.00mV 15.50mV 12.70mV Pass

30% Load 17.10mV 9.70mV 15.90mV 15.40mV Pass

40% Load 18.00mV 10.60mV 16.50mV 16.60mV Pass

50% Load 21.10mV 11.50mV 17.30mV 17.50mV Pass

60% Load 24.40mV 12.60mV 18.00mV 20.80mV Pass

70% Load 29.20mV 13.70mV 18.90mV 22.30mV Pass

80% Load 35.30mV 15.90mV 25.60mV 23.80mV Pass

90% Load 38.10mV 17.10mV 27.00mV 24.60mV Pass

100% Load 47.90mV 20.00mV 29.30mV 28.20mV Pass

110% Load 53.00mV 21.70mV 32.10mV 30.10mV Pass

Crossload1 26.00mV 17.00mV 35.50mV 17.40mV Pass

Crossload2 52.60mV 12.60mV 20.50mV 25.20mV Pass

All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics PAGE 15/16
› The link to the original test results document should be provided in any case

Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient www.cybenetics.com [email protected]
and silent power supplies are promoted 4004 MESA GEITONIA, LIMASSOL, CYPRUS
EFFICIENCY AND NOISE
LEVEL CERTIFICATIONS

Anex Cougar VTE Bronze 600W

Top side Power specifications label

CERTIFICATIONS 115V

CERTIFICATIONS 230V

All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics PAGE 16/16
› The link to the original test results document should be provided in any case

Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient www.cybenetics.com [email protected]
and silent power supplies are promoted 4004 MESA GEITONIA, LIMASSOL, CYPRUS

You might also like