1 Footing Plan PDF

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

*NOTE: WE ARE ONLY RESPONSIBLE FOR SOUNDNESS OF STRUCTURE

REFLECTED THROUGH THE DRAWING ONLY & NOT FOR EXECUTION.


GENERAL NOTES:
1. THIS DRAWING SHALL BE READ IN CONJUNCTION WITH ALL STRUCTURAL,
ARCHITECTURAL, SERVICES DRAWINGS. AND SPECIFICATIONS.
2. FOLLOW WRITTEN DIMENSIONS ONLY DO NOT SCALE THE DRGS.
3. ANOMALIES IN THE DRAWINGS. SHALL BE BROUGHT TO THE NOTICE OF
THE STRUCTURAL CONSULTANT AND ARCHITECT BEFORE EXECUTION.
4. SEPARATE DETAIL IF ANY GIVEN IN ACTUAL WORKING DRAWING WILL
SUPERSEDE THESE DETAILS.
5. ALL STRUCTURAL CONCRETE SHOULD BE WEIGH BATCHED, MACHINE
MIXED & MECHANICALLY VIBRATED.
6. ALL DIMENSIONS IN THIS DRAWINGS ARE IN MM.(UNLESS SPECIFIED)
7. CLEAR COVER TO REINFORCEMENT SHALL BE, COVER FOR MODERATE AND
SEVERE EXPOSURE CONDITION
* COLUMN = 40 mm, * FOOTING = 50 mm SHOULD BE INCREASED
* BEAM = 25 mm, * SLAB = 15 mm
8. MAXIMUM ALLOWABLE HEIGHT OF COLUMN WITHOUT ANY BRACE OR TIE
a) 230 WIDE-4000mm. b) 200 WIDE-3400mm. c) 300 WIDE-5000mm.
10.LAP LENGTH WHERE " D " IS DIAMETER OF BAR.
M20 M25
LAPING IS NOT ALLOWED IN FOOTING AS ,
COLUMNS / STRUTS 52xD 46xD WELL AS IN CANTILEVER BEAMS,
52xD 46xD R/F FOR THESE MUST BE IN SINGLE PIECE.
BEAM / SLAB
a) COLUMN BARS SHALL BE LAPPED ONLY IN CENTRAL HALF OF ITS LENGTH.NOT MORE
THAN 50 % OF THE BARS SHALL BE LAPPED AT ONE SECTION.
b) AT ANY SECTION OF SLAB/BEAM NOT MORE THAN 50%
c) BARS TO BE LAPPED & LAPS SHOULD BE STAGGERED.
*STRUCTURAL LAYOUT OF :-
10.FOR CANTILEVERS, TOP BARS TO BE ANCHORED BEHIND FOR-70X DIA. OF
COLUMN AND FOOTING. BARS OR SPAN OF CANTILEVERS - *WHICHEVER IS GREATER
11.CONCRETING IN STEP FOOTING FOR ALL STEPS SHOULD CAST
MONOLITHICALLY AT ONCE.
12.LONG SPAN REINFORCEMENT IN " FOOTINGS" SHALL BE PLACED BELOW
THE SHORT SPAN REINFORCEMENT SHORT SPAN REINFORCEMENT
13.CONCRETING IN STEP FOOTING FOR ALL THE STEPS SHOULD CAST
MONOLITHICALLY AT ONCE.
14.'T' NOTES TOR STEEL CONFORMING TO GRADE Fe 500 (FY = 500 N/mm2)
15. FORM WORK SHALL BE REMOVED IN ACCORDANCE WITH IS:456 -2000.

b < 300 mm
h1 < 300 mm
h1 < 300 mm

MINIMUM
6MM:75MM
8MM:80MM
10MM:100MM LINKS DETAILS
or 10 d ( SCALE : NTS )
whichever GREATER

* TYPICAL FOR
LINKs and LOOPs
( SCALE : NTS )