0% found this document useful (0 votes)
95 views5 pages

Pi2794 02 - en GB

This document provides specifications for a flush pressure sensor with a 4-digit display, including two status LEDs and a programming button. It measures pressure from -1 to 10 bar with connections for food and beverage applications. The sensor has two digital outputs, one analog output, and can operate from 20-32VDC. Accuracy is within 0.2% of the span with good temperature stability and repeatability.

Uploaded by

phalkejitu
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
95 views5 pages

Pi2794 02 - en GB

This document provides specifications for a flush pressure sensor with a 4-digit display, including two status LEDs and a programming button. It measures pressure from -1 to 10 bar with connections for food and beverage applications. The sensor has two digital outputs, one analog output, and can operate from 20-32VDC. Accuracy is within 0.2% of the span with good temperature stability and repeatability.

Uploaded by

phalkejitu
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 5

PI2794

Flush pressure sensor with display


PI-010-REA01-MFRKG/US/ /P

1 alphanumeric display 4-digit


2 status LEDs
3 programming button

Product characteristics
Number of inputs and outputs Number of digital outputs: 2; Number of analogue outputs: 1
Measuring range -1...10 bar -14.5...145 psi -0.1...1 MPa
Process connection threaded connection G 1 external thread Aseptoflex Vario
Application
Special feature Gold-plated contacts
Application flush mountable for the food and beverage industry
Media viscous media and liquids with suspended particles; liquids and gases
Medium temperature [°C] -25...125; (145 max. 1h)
Min. bursting pressure 150 bar 2175 psi 15 MPa
Pressure rating 50 bar 725 psi 5 Mpa
Vacuum resistance [mbar] -1000
Type of pressure relative pressure; vacuum
No dead space yes
MAWP (for applications 50 bar 725 psi 5 MPa
according to CRN)

ifm electronic gmbh • Friedrichstraße 1 • 45128 Essen — We reserve the right to make technical alterations without prior notice. — EN-GB — PI2794-02 — 30.10.2013 —
PI2794
Flush pressure sensor with display
PI-010-REA01-MFRKG/US/ /P

Electrical data
Min. insulation resistance [MΩ] 100; (500 V DC)
Protection class III
Reverse polarity protection yes
Integrated watchdog yes
2-wire
Operating voltage [V] 20...32 DC
Current consumption [mA] 3.6...21
Power-on delay time [s] 1
3-wire
Operating voltage [V] 18...32 DC
Current consumption [mA] < 45
Power-on delay time [s] 0.5
Inputs / outputs
Number of inputs and outputs Number of digital outputs: 2; Number of analogue outputs: 1
Outputs
Total number of outputs 2
Output signal switching signal; analogue signal; IO-Link; (configurable)
Electrical design PNP/NPN
Number of digital outputs 2
Output function normally open / normally closed; (parameterisable)
Number of analogue outputs 1
Analogue current output [mA] 4...20, invertible; (scalable)
Short-circuit protection yes
Type of short-circuit
pulsed
protection
Overload protection yes
2-wire
Max. load [Ω] 300
3-wire
Max. voltage drop switching
[V] 2
output DC
Permanent current rating of
[mA] 250
switching output DC
Switching frequency DC [Hz] 125
Max. load [Ω] (Ub - 10 V) / 20 mA

ifm electronic gmbh • Friedrichstraße 1 • 45128 Essen — We reserve the right to make technical alterations without prior notice. — EN-GB — PI2794-02 — 30.10.2013 —
PI2794
Flush pressure sensor with display
PI-010-REA01-MFRKG/US/ /P

Measuring/setting range
Measuring range -1...10 bar -14.5...145 psi -0.1...1 MPa
Set point SP -0.98...10 bar -14.2...145 psi -0.098...1 MPa
Reset point rP -1...9.98 bar -14.5...144.7 psi -0.1...0.998 MPa
Analogue start point -1...7.5 bar -14.5...108.7 psi -0.1...0.75 MPa
Analogue end point 1.5...10 bar 21.8...145 psi 0.15...1 MPa
In steps of 0.01 bar 0.1 psi 0.001 MPa
SP1 = 2.50 bar rP1 = 2.30 bar
Factory setting SP2 = 7.50 bar rP2 = 7.30 bar
ASP = 0.00 bar AEP = 10.00 bar
Accuracy / deviations
Switch point accuracy
< ± 0,2; (Turn down 1:1)
[% of the span]
Repeatability [% of the span] < ± 0,1; (with temperature fluctuations < 10 K; Turn down 1:1)
Characteristics deviation < ± 0,2; (Turn down 1:1 , linearity, incl. hysteresis and
[% of the span] repeatability , limit value setting to DIN EN IEC 62828-1)
Linearity deviation
< ± 0,15; (Turn down 1:1)
[% of the span]
Hysteresis deviation
< ± 0,15; (Turn down 1:1)
[% of the span]
Long-term stability
< ± 0,1; (Turn down 1:1; per year)
[% of the span]
Temperature coefficient zero
point < ± 0,05; (0...70 °C)
[% of the span / 10 K]
Temperature coefficient span
< ± 0,15; (0...70 °C)
[% of the span / 10 K]
Response times
Damping for the switching
[s] 0...30
output dAP
Damping for the analogue
[s] 0.01...99.99
output dAA
2-wire
Step response time analogue
[ms] 45
output
3-wire
Min. response time of
[ms] 3
switching output (dAP)
Step response time analogue
[ms] 7
output

ifm electronic gmbh • Friedrichstraße 1 • 45128 Essen — We reserve the right to make technical alterations without prior notice. — EN-GB — PI2794-02 — 30.10.2013 —
PI2794
Flush pressure sensor with display
PI-010-REA01-MFRKG/US/ /P

Interfaces
Communication interface IO-Link
Transmission type COM2 (38,4 kBaud)
IO-Link revision 1.0
Profiles no profile
SIO mode yes
Required master port type A
Process data analogue 1
Process data binary 2
Min. process cycle time [ms] 2.3
Type of operation DeviceID
Supported DeviceIDs
Default 157
Operating conditions
Ambient temperature [°C] -25...80
Storage temperature [°C] -40...100
Protection IP 67; IP 68; IP 69K
Tests / approvals
DIN EN 61000-6-2
EMC
DIN EN 61000-6-3
Shock resistance DIN EN 60068-2-27 50 g (11 ms)
Vibration resistance DIN EN 60068-2-6 20 g (10...2000 Hz)
MTTF [years] 160
Note on approval factory certificate available as download at www.factory-certificate.ifm
Mechanical data
Weight [g] 351.8
Materials stainless steel (1.4404 / 316L); FKM; PTFE; PBT; PEI; PFA
ceramics (99.9 % Al2O3); stainless steel (1.4435 /
Materials (wetted parts)
316L); surface characteristics: Ra < 0,4 / Rz 4; PTFE
Min. pressure cycles 100 million
Process connection threaded connection G 1 external thread Aseptoflex Vario
Displays / operating elements
Display unit LED, green
switching status LED, yellow
Display
function display alphanumeric display, 4-digit
measured values alphanumeric display, 4-digit
Display unit bar; psi; MPa; % of the span
Remarks
Pack quantity 1 pcs.
Electrical connection
Connector: 1 x M12; Contacts: gold-plated

ifm electronic gmbh • Friedrichstraße 1 • 45128 Essen — We reserve the right to make technical alterations without prior notice. — EN-GB — PI2794-02 — 30.10.2013 —
PI2794
Flush pressure sensor with display
PI-010-REA01-MFRKG/US/ /P

Connection

1 connection for 2-wire operation


2 connection for 3-wire operation :
OUT1 switching output
OUT2 switching output
analogue output
3 connection for IO-Link parameter setting (P = communication via IO-Link)

ifm electronic gmbh • Friedrichstraße 1 • 45128 Essen — We reserve the right to make technical alterations without prior notice. — EN-GB — PI2794-02 — 30.10.2013 —