TI Manual Side Elevator
TI Manual Side Elevator
TI Manual Side Elevator
This document contains confidential information. All rights including copyright, confidential information, trade
secrets and design rights are owned by Texas International Oilfield Tools, LTD (TIOT, Texas International,
and Texas International Oilfield Tools). No use or disclosure is to be made without prior written permission of
Texas International Oilfield Tools, LTD.
Revision History
Description of Change
Rev Change
A -
GENERAL ...................................................................................................................... 4
CONVENTIONS ............................................................................................................. 5
SAFETY ......................................................................................................................... 5
SPECIFICATIONS ......................................................................................................... 6
OM001-A www.TEXASINTERNATIONAL.com 3
GENERAL
Figure 1
Texas International Oilfield Tools (TIOT) offers conventional side door elevators in two
(2) different types: SLX and SX. See Specifications table on page 6 for load capacity
and size ranges. The elevators hoist casing and drill collars. SLX and SX elevators
should only be used with tubular having square shoulder connections or lifting plugs.
The elevator has a simple, reliable door, latch and safety latch that simultaneously
locks when the door closes. The safety pin is fixed with a cable onto the elevator to
prevent loss. Ears are strategically placed to avoid picking up the tubular with the
elevator inverted.
The SLX elevators (Figure 1 above) are designed for all size casing up to 42” with load
rating from 100 to 500 ton. The shielded safety latch protects the latch from
accidentally opening. To open, simply pull the safety pin, pull the latch lock handle out,
and swing the elevator halves apart. Both latches operate from a single handle and
automatically re-latch when the elevator door is closed.
The SX elevator (Figure 2), designed for handling large, collar type casing, is sturdier
and has a safety latch requiring two (2) handed operation. The casing size ranges up
to 36” with load rating of 350 and 500 tons.
4 Texas International Oilfield Tools, LTD. OM001-A
General continued
Figure 2
CONVENTIONS
SAFETY
OM001-A www.TEXASINTERNATIONAL.com 5
Safety continued
SPECIFICATIONS
SX Part Number
Size Range Frame PN + BC Capacity
9‐5/8"‐ 13‐3/8" T29964‐XXX 500 Tons
9‐5/8"‐ 13‐3/8" T29965‐XXX 350 Tons
14” ‐ 18‐5/8" T29966‐XXX 350 Tons
BC= Bore code shown as XXX above
Table 2
SLX Part Number
Size Range Frame PN + BC Capacity
2‐3/8"‐ 2‐7/8" T33693‐XXX 100 Tons
3‐1/2” – 5‐1/2” T33854‐XXX 100 Tons
4–1/2” – 8‐5/8” T31239‐XXX 150 Tons
9‐5/8” – 10‐3/4” T33950‐XXX 150 Tons
11‐3/4” – 13‐5/8” T33982‐XXX 150 Tons
18‐5/8” – 20” T33632‐XXX 150 Tons
5‐1/2” – 7‐5/8” T41239‐XXX 250 Tons
8‐5/8” – 10‐3/4” T43950‐XXX 250 Tons
11‐3/4” – 13‐5/8” T43982‐XXX 250 Tons
16” – 20” T43632‐XXX 250 Tons
6‐5/8” – 9‐7/8” T53950‐XXX 350 Tons
10‐3/4” – 13‐3/8” T53982‐XXX 350 Tons
42” 42ELEV 500 Tons
BC= Bore code shown as XXX above
Table 3
When there is suspicion that the elevator has been overloaded, it should be
pulled from operation for an Annual type PM
Normal wear in course of use will eventually reduce the elevator’s capability. Inspect
the bore, latch, latch pin and hinge pin regularly for wear. Cracks or the appearance of
damage can indicate disrepair, even impending failure, and requires prompt attention.
The elevator must be either pulled from operation immediately or repaired.
Semi-Annual (PM2)
Try to open the latch by prying the latch between body and latch with a steel bar
or screw driver – the latch lock prevents the latch from being opened (figures 3
and 4). If the elevator opens during pry test, pull from operation for repair
Verify bore dimension is within API specification (see table 4)
Remove coating and debris from critical areas
Disassemble and perform Magnetic Particle Inspection (MPI) on critical areas as
indicated on API Specification 8C
Carry on daily PM
Annual (PM3)
Repeat daily and semi-annual PMs
Performance load test
MPI critical areas twenty four (24) hours after load test
OM001-A www.TEXASINTERNATIONAL.com 7
Preventative Maintenance continued
Proof of load test and MPI are required after remanufacture or a major weld
repair in a critical area
The wear of the elevator bore affects its ability to support the required load. Elevators
for which the bore measurements exceed the ‘Maximum Allowable Wear’ shown in
tables 4 through 6 shall either be remanufactured or scrapped.
Drill Collars with Zip Lift Recess
Bore Maximum Allowable
Collar OD
Code Wear (in)
4‐1/8'' 177 3.844
4‐3/4'' 435 4.406
5‐1/4'' 179 4.906
5‐1/2'' 180 5.156
5‐3/4'' 181 5.313
6'' 362 5.563
6‐1/4'' 337 5.813
6‐1/2'' 373 6.063
6‐3/4'' 387 6.250
7'' 361 6.500
7‐1/4'' 357 6.750
7‐1/2'' 188 7.000
7‐3/4'' 339 7.250
8'' 336 7.500
8‐1/4'' 422 7.750
8‐1/2'' 426 8.000
9'' 427 8.438
9‐1/2'' 370 8.938
9‐3/4'' 367 9.188
10'' 195 9.438
10‐3/4'' 527 10.188
11'' 419 10.438
11‐1/4'' 196 10.688
Table 4
OM001-A www.TEXASINTERNATIONAL.com 9
Elevator Wear Limits continued
Plain Drill Collars with Lift Plug Casing
Bore Maximum Allowable Bore Maximum Allowable
Collar OD Casing Size (in)
Code Wear (in) Code Wear (in)
3'' 205 3.188 2 3/8 158 2.512
3‐1/8'' 206 3.313 2 7/8 160 3.013
3‐1/4'' 207 3.438 3 1/2 162 3.639
3‐1/2'' 209 3.688 4 1/2 129 4.659
3‐3/4'' 211 3.938 4 3/4 130 4.913
4'' 213 4.188 5 131 5.168
4‐1/8'' 519 4.313 5 1/2 132 5.676
4‐1/4'' 548 4.438 5 3/4 133 5.931
4‐1/2'' 215 4.688 6 134 6.185
4‐3/4'' 354 4.969 6 5/8 135 6.821
5'' 552 5.219 7 136 7.203
5‐1/4'' 219 5.469 7 5/8 137 7.838
5‐1/2'' 411 5.719 8 5/8 139 8.856
5‐3/4'' 222 6.031 9 140 9.238
6'' 349 6.281 9 5/8 141 9.873
6‐1/4'' 348 6.531 9 7/8 649 10.128
6‐3/8'' 331 6.656 10 831 10.255
6‐3/4'' 338 7.063 10 1/8 846 10.382
7'' 372 7.313 10 3/4 142 11.018
7‐1/4'' 335 7.563 11 3/4 143 12.036
7‐1/2'' 137 7.813 13 3/8 144 13.664
7‐3/4'' 550 8.063 13 5/8 596 13.918
8'' 334 8.313 16 145 16.335
8‐1/4'' 347 8.563 18 723 18.370
8‐1/2'' 580 8.844 18 5/8 146 19.006
8‐3/4'' 226 9.094 20 147 20.405
9'' 356 9.344 21 1/2 148 21.925
9‐1/4'' 227 9.594 22 688 22.431
9‐1/2'' 346 9.844 24 630 24.456
10 228 10.406 26 650 26.481
10‐1/2'' 229 10.906 28 693 28.506
11'' 230 11.406 30 644 30.531
Table 5 Table 6
Ear Radius ( R ) Minimum
based on tons ( in)
100 1
150 1 1/2
250 1 7/8
350 1 7/8
500 2
Figure 5
Table 7
SX
Figure 6
Elevator Type SX 350/500
Total Clearance
(in)
Hinge Pin 0.030
Latch Pin 0.035
Table 8
OM001-A www.TEXASINTERNATIONAL.com 11
Critical Area Map continued
SLX
Figure 7
Elevator Type SLX
Capacity (in Tons) 100 150/250 350
Total Clearance (in)
Hinge Pin 0.020 0.035 0.035
Latch Pin 0.020 0.030 0.035
Table 9
OM001-A www.TEXASINTERNATIONAL.com 13
SPARE PARTS LIST
Figure 8
SX Spare Parts List
# Frame PN T29964 T29965 T29966
Range (in) 9 5/8 ‐ 13 3/8 9 5/8 ‐ 13 3/8 14 ‐ 18 5/8
Capacity / Max Operational Load (Ton) Req 500 350 350
Item Component
1 LATCH PIN 1 T29951
2 HINGE PIN 1 T29956
3 LINK BLOCK 2 T9519
4 LATCH LOCK PIN RETAINER 1 T5302
5 LATCH LOCK PIN 1 T6027
6 SAFETY PIN 1 080070
7 LATCH SPRING PLUG 2 T8024
8 LATCH LOCK SPRING 2 T30657
9 LATCH LOCK 1 T6021
10 LATCH 1 T30597 T29945 T20005
Table 11
Figure 9
SLX 100 Spare Parts List
Frame PN T33693 T33854
#
Range (in) Req 2 3/8 ‐ 2 7/8 3 1/2 ‐ 5 1/2
Item Component
1 LINK BLOCK 2 T32430
2 LATCH PIN 1 T33700‐4 T29980‐3
3 HINGE PIN 1 T32424‐5 T34613
4 HINGE PIN RETAINER 1 T34614 T32918
5 LATCH LOCK PIN 1 T33700‐4 T29980‐3
6 SAFETY PIN 1 080042
7 LATCH LOCK SPRING 2 T33701 T33816
8 LATCH SPRING 2 T33703 T33818
9 LATCH LOCK 1 T33696 T33812
13 ROLLER PIN 2 T33698 T31584
11 LATCH 1 T33697 T33813
12 ROLLER 2 T33702 T33817
Table 12
OM001-A www.TEXASINTERNATIONAL.com 15
Spare Parts List continued
SLX 150 Spare Parts List
Frame PN T31239 T33950 T33982 T33632
#
Range (in) Req 4 1/2 ‐ 8 5/8 9 5/8 ‐ 10 3/4 11 3/4 ‐ 13 3/8 16 ‐ 20
Component
1 LINK BLOCK 2 T9519
2 LATCH PIN 1 T32424‐3 T33645
3 HINGE PIN 1 T34611 T33953 T33985 T33646
4 HINGE PIN RETAINER 1 T32892 T32892
5 LATCH LOCK PIN 1 T29980‐4 T50713
6 SAFETY PIN 1 080042
7 LATCH LOCK SPRING 2 T31404 T33658
8 LATCH SPRING 2 T31383 T33657
9 LATCH LOCK 1 T31332 T33635
10 ROLLER PIN 2 T31584
11 LATCH 1 T31331 T33634
12 ROLLER 2 T31407
Table 13
SLX 250 Spare Parts List
Frame PN T41239 T43950 T43982 T43632
#
Range (in) Req 5 1/2 ‐ 7 5/8 8 5/8 ‐ 10 3/4 11 3/4 ‐ 13 5/8 16 ‐ 18 5/8
Component
1 LINK BLOCK 2 T9519
2 LATCH PIN 1 T32424‐3 T33645
3 HINGE PIN 1 T34611‐1 T33953‐1 T33985‐1 T33346‐1
4 HINGE PIN RETAINER 1 T32892 T31074
5 LATCH LOCK PIN 1 T29980‐4 T29980‐4 T50713‐2 T32424‐2
6 SAFETY PIN 1 080042
7 LATCH LOCK SPRING 2 T31388 T33658
8 LATCH SPRING 2 T31383 T33657
9 LATCH LOCK 1 T31332 T33635
10 ROLLER PIN 2 T31584
11 LATCH 1 T31331 T33634
12 ROLLER 2 T31407
Table 14
SLX 350 Spare Parts List
Frame PN T53950 T53982
#
Range (in) Req 6 5/8 ‐ 9 7/8 10 3/4 ‐ 13 3/8
Component
1 LINK BLOCK 2 T9519
2 LATCH PIN 2 T33645 T33613
3 HINGE PIN 1 T35009 T35001
4 HINGE PIN RETAINER 1 T35171 T35314
5 LATCH LOCK PIN 1 T32424‐2 T33643
6 SAFETY PIN 1 080042
7 LATCH LOCK SPRING 2 T33658 T33623
8 LATCH SPRING 1 T33657 T33628
9 LATCH LOCK 1 T33635 T33642
10 ROLLER PIN 1 N/A T31584
11 LATCH 1 T33634 T33612
12 ROLLER 1 N/A T31407
13* HINGE PIN RETAINER RING 2 T35052 N/A
14* LINK BLOCK PIN CLIP 2 T32051 N/A
15* LATCH SPRING PIN 1 T32018 N/A
* Not shown
Table 15
OM001-A www.TEXASINTERNATIONAL.com 17
Every Company has to have a Toolbox
at Texas International Oilfield Tools.
We provide the tools to fuel the
world!
The terms VARCO, VARCO-BJ, and BJ are trademarks of Varco I/P, Inc., National Oilwell Varco, L.P., or their affiliates. Texas International Oilfield
Tools is not an authorized distributor of any Varco I/P or NATIONAL OILWELL VARCO product. Texas International Oilfield Tools is not affiliated with
Varco I/P, Inc., National Oilwell Varco, L.P., or their affiliates. Varco I/P, Inc., National Oilwell Varco, L.P., and their affiliates do not endorse any Texas
International Oilfield Tools' products or replacement parts.