Chapter One
D.C. Generators
Alternating Current (AC)
In alternating current the electric charges flow changes its direction periodically. AC is the
most commonly used and most preferred electric power for household equipment office and
buildings Alternating current can be identified in wave form called as sine wave
1|Page
University of Anbar
College of Engineering
Mech. Eng. Dept. Prepared by
Mohanad A. A. Alheety
ـــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــ
Difference Between Alternating Current and Direct Current
Generator Principle
An electric generator is a machine that converts mechanical energy into electrical energy. An
electric generator is based on the principle that whenever flux is cut by a conductor, an e.m.f.
is induced which will cause a current to flow if the conductor circuit is closed. The direction
of induced e.m.f. (and hence current) is given by Fleming’s right hand rule. Therefore, the
essential components of a generator are:
(a) A magnetic field
(b) Conductor or a group of conductors
(c) Motion of conductor w.r.t. magnetic field.
2|Page
University of Anbar
College of Engineering
Mech. Eng. Dept. Prepared by
Mohanad A. A. Alheety
ـــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــ
(i) When the loop is in position no.1 the generated e.m.f. is zero because the coil sides
(AB and CD) are cutting no flux but are moving parallel to it.
(ii) When the loop is in position no. 2, the coil sides are moving at an angle
3|Page
University of Anbar
College of Engineering
Mech. Eng. Dept. Prepared by
Mohanad A. A. Alheety
ـــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــ
to the flux and, therefore, a low e.m.f. is generated as indicated by point 2.
(iii) When the loop is in position no. 3, the coil sides (AB and CD) are at
right angle to the flux and are, therefore, cutting the flux at a maximum
rate. Hence at this instant, the generated e.m.f. is maximum as indicated
by point 3 in Figure
(iv) At position 4, the generated e.m.f. is less because the coil sides are
cutting the flux at an angle.
(v) At position 5, no magnetic lines are cut and hence induced e.m.f. is
zero as indicated by point 5 in Fig.
(vi) At position 6, the coil sides move under a pole of opposite polarity and
hence the direction of generated e.m.f. is reversed. The maximum
e.m.f.
in this direction (i.e., reverse direction) will be when the loop is at position 7 and zero
when at position 1. This cycle repeats with each revolution of the coil.
4|Page
University of Anbar
College of Engineering
Mech. Eng. Dept. Prepared by
Mohanad A. A. Alheety
ـــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــ
Note that e.m.f. generated in the loop is alternating one. It is because any coil side, say AB has
e.m.f. in one direction when under the influence of N-pole and in the other direction when
under the influence of S-pole. If a load is connected across the ends of the loop, then
alternating current will flow through the load. The alternating voltage generated in the loop
can be converted into direct voltage by a device called commutator. We then have the d.c.
generator. In fact, a commutator is a mechanical rectifier.
Commutator
If, somehow, connection of the coil side to the external load is reversed at the same instant the
current in the coil side reverses, the current through the load will be direct current. This is
what a commutator does. The figure shows a commutator having two segments C 1 and C2. It
consists of a cylindrical metal ring cut into two halves or segments C 1 and C2 respectively
separated by a thin sheet of mica.
The commutator is mounted on but insulated from the rotor shaft. The ends of coil sides AB
and CD are connected to the segments C1 and C2 respectively as shown. Two stationary
carbon brushes rest on the commutator and lead current to the external load. With this
arrangement, the commutator at all times connects the coil side under S-pole to the +ve brush
and that under N-pole to the ve brush.
(i) In Fig below, the coil sides AB and CD are under N-pole and S-pole respectively. Note
that segment C1 connects the coil side AB to point P of the load resistance R and the
segment C2 connects the coil side CD to point Q of the load. Also note the direction of
current through load. It is from Q to P.
5|Page
University of Anbar
College of Engineering
Mech. Eng. Dept. Prepared by
Mohanad A. A. Alheety
ـــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــ
(ii) After half a revolution of the loop (i.e., 180° rotation), the coil side AB is under S-pole
and the coil side CD under N-pole as shown in Fig. (1.5). The currents in the coil sides
now flow in the reverse direction but the segments C 1 and C2 have also moved through
180° i.e., segment C1 is now in contact with +ve brush and segment C2 in contact with
ve brush. Note that commutator has reversed the coil connections to the load i.e., coil
side AB is now connected to point Q of the load and coil side CD to the point P of the
load. Also note the direction of current through the load. It is again from Q to P.
6|Page
University of Anbar
College of Engineering
Mech. Eng. Dept. Prepared by
Mohanad A. A. Alheety
ـــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــ
Construction of a DC Generator
1. Yoke: The outer frame of a dc machine is called as yoke. It is made up of cast iron or
steel. It not only provides mechanical strength to the whole assembly but also carries the
magnetic flux produced by the field winding.
7|Page
University of Anbar
College of Engineering
Mech. Eng. Dept. Prepared by
Mohanad A. A. Alheety
ـــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــ
3. Field winding: Each pole core has one or more field coils (windings) placed over it to
produce a magnetic field. The copper wire is used for the construction of field or exciting
coils. The coils are wound on the former and then
placed around the pole core
When direct current passes through the field winding, it
magnetizes the poles, which in turns produces the flux.
The field coils of all the poles are connected in series in
such a way that when current flows through them, the
adjacent poles attain opposite polarity.
4. Armature core: Armature core is the rotor of the machine. It is cylindrical in shape with
slots to carry armature winding. The armature is built up of thin laminated circular steel
disks for reducing eddy current losses.
The armature core of a DC generator or machine serves the
following purposes.
- It houses the conductors in the slots.
- It provides an easy path for the magnetic flux
8|Page
University of Anbar
College of Engineering
Mech. Eng. Dept. Prepared by
Mohanad A. A. Alheety
ـــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــ
6. Shaft
The shaft is made of mild steel with a maximum breaking strength. The shaft is used to
transfer mechanical power from or to the machine. The rotating parts like armature core,
commutator, cooling fans, etc. are keyed to the shaft.
9|Page
University of Anbar
College of Engineering
Mech. Eng. Dept. Prepared by
Mohanad A. A. Alheety
ـــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــ
The voltage output depends upon the speed of rotation of armature and the field current The
greater the speed and field current, greater is the generated e.m.f. It may be noted that
separately excited d.c. generators are rarely used in practice. The d.c. generators are normally
of self-excited type.
10 | P a g
University of Anbar
College of Engineering
Mech. Eng. Dept. Prepared by
Mohanad A. A. Alheety
ـــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــ
Armature current, Ia = IL
e.m.f generated, Eg = V IaRa
Electric power developed = EgIa
Power delivered to load = 𝑉𝐼𝑎
11 | P a g
University of Anbar
College of Engineering
Mech. Eng. Dept. Prepared by
Mohanad A. A. Alheety
ـــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــ
12 | P a g
University of Anbar
College of Engineering
Mech. Eng. Dept. Prepared by
Mohanad A. A. Alheety
ـــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــ
(iii) Compound generator
In a compound-wound generator, there are two sets of field windings on each pole—one is in
series and the other in parallel with the armature. A compound wound generator may be:
(a) Short Shunt in which only shunt field winding is in parallel with the
armature winding
(b) Long Shunt in which shunt field winding is in parallel with both
series field and armature winding
Short shunt
Series field current, Ise = IL
Shunt field current= 𝐼𝑠ℎ
V+𝐼𝑠𝑒𝑅𝑠𝑒
= 𝑅𝑠ℎ
Long shunt
13 | P a g
University of Anbar
College of Engineering
Mech. Eng. Dept. Prepared by
Mohanad A. A. Alheety
ـــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــ
Series field current, Ise = Ia = IL + Ish
Shunt field current, Ish = V/Rsh
e.m.f generated, Eg = V Ia(Ra +
Rse) Power developed in armature =
EgIa Power delivered to load = VIL
Ex1: A shunt generator delivers 450 A at 230 V and the resistance of the shunt field
and armature are 50 Ω and 0.03 Ω respectively. Calculate the generated e.m.f.
Solution:
Shunt current Ish 230
= = 4.6 A
50
14 | P a g
University of Anbar
College of Engineering
Mech. Eng. Dept. Prepared by
Mohanad A. A. Alheety
ـــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــ
Ex2/long-shunt compound generator delivers a load current of 50 A at 500 V and
has armature, series field and shunt field resistances of 0.05 Ω, 0.03 Ω and 250 Ω respectively.
Calculate the generated voltage and the armature current. Allow 1 V per brush for contact
drop.
Solution:
500
Ish = = 2A
250
Ex3: A short-shunt compound generator delivers a load current of 30 A at 220 V, and has
armature, series-field and shunt-field resistances of0.05 Ω, 0.30 Ω and 200 Ω respectively.
Calculate the induced e.m.f. and the armature current. Allow 1.0 V per brush for contact drop.
Solution:
drop in series winding = 30 × 0.3 = 9 V
Voltage across shunt winding = 220 + 9 = 229 V Ish = 229/200 = 1.145 A
Ia = 30 + 1.145 = 31.145 A
IaRa = 31.145 . 0.05 = 1.56 V
15 | P a g
University of Anbar
College of Engineering
Mech. Eng. Dept. Prepared by
Mohanad A. A. Alheety
ـــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــ
Brush drop = 2 . 1 = 2 V
Eg = V + series drop + brush drop + IaRa
= 220 + 9 + 2 + 1.56 = 232.56 V
Ex4: In a long-shunt compound generator, the terminal voltage is 230 V when generator
delivers 150 A. Determine (i) induced e.m.f. (ii) total power generated and . Given that shunt
field, series field, divertor and armature resistance are 92 Ω, 0.015 Ω, 0.03 Ω and 0.032 Ω
respectively.
Solution:
Ish = 230/92 = 2.5 A
Ia = 150 + 2.5 = 152.5 A
Since series field resistance and divertor
resistances are in parallel (thei r
combined resistance is
= 0.03 × 0.015/0.045 = 0.01 Ω
Total armature circuit resistance is
= 0.032 + 0.01 = 0.042 Ω
Voltage drop = 152.5 × 0.042 = 6.4 V
(𝐢) Voltage generated by armature
Eg = 230 + 6.4 = 236.4 V
(𝐢𝐢) Total power generated in
armature EgIa = 236.4 × 152.5 =
36,051 W
16 | P a g
University of Anbar
College of Engineering
Mech. Eng. Dept. Prepared by
Mohanad A. A. Alheety
ـــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــ
𝐄𝐠 = 𝚽 𝐏 𝐍 𝐙
.
𝟔𝟎 𝐀
Where, A=2 for a simplex wave-wound generator
A=P for a simplex lap-wound generator
17 | P a g
University of Anbar
College of Engineering
Mech. Eng. Dept. Prepared by
Mohanad A. A. Alheety
ـــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــ
Ex5: An 8-pole d.c. generator has 500 armature conductors, and a useful flux of 0.05 Wb
per pole. What will be the e.m.f. generated if it is lap-connected and runs at 1200 rpm ?
What must be the speed at which it is to be driven produce the same e.m.f. if it is wave-
wound?
Solution:
ΦPN Z
Eg = .
60 A
Ex6: An 8-pole d.c. shunt generator with 778 wave-connected armature conductors and
running at 500 r.p.m. supplies a load of 12.5 Ω resistance at terminal voltage of 250 V. The
armature resistance is 0.24 Ω and the field resistance is 250 Ω. Find the armature current, the
induced e.m.f. and the flux per pole.
Solution:
Load current = V/R = 250/12.5 = 20 A
Shunt current = 250/250 = 1 A
Armature current = 20 + 1 = 21 A
Induced e. m. f. = 250 + (21 × 0.24) = 255.04 V
ΦPN Z
Eg = .
60 A
Φ × 8 × 500 778
255.04 = .
60 2
Φ = 9.83 mWb
18 | P a g
University of Anbar
College of Engineering
Mech. Eng. Dept. Prepared by
Mohanad A. A. Alheety
ـــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــ
Ex7: A 4-pole lap-connected armature of a d.c. shunt generator is required to supply the loads
connected in parallel:
(1) 5 kW Geyser at 250 V, and
(2) 2.5 kW Lighting load also at 250 V.
The Generator has an armature resistance of 0.2 ohm and a field resistance of 250 ohms. The
armature has 120 conductors in the slots and runs at 1000 rpm. Allowing 1 V per brush for
contact drops and neglecting friction, find Flux per pole.
Solution:
Geyser current = 5000/250 = 20 A
Current for Lighting = 2500/250 = 10 A
Total current = 30 A
Field Current for Generator = 1 A (250v\250ohm)
Hence, Armature Current = 31 A
Armature resistance drop = 31 × 0.2 = 6.2 volts
Generated e. m. f. = 250 + 6.2 + 2(2 brushes) = 258.2 V,
ΦPN Z
Eg = .
60 A
Φ × 1000 × 120
258.2 =
60
Φ = 129.1 mWb
19 | P a g
University of Anbar
College of Engineering
Mech. Eng. Dept. Prepared by
Mohanad A. A. Alheety
ـــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــ
Ex8: A 4-pole, d.c. shunt generator with a shunt field resistance of 100 Ω and an armature
resistance of 1 Ω has 378 wave-connected conductors in its armature. The flux per pole is
0.02 Wb. If a load resistance of 10 Ω is connected across the armature terminals and the
generator is driven at 1000 r.p.m., calculate the power absorbed by the load.
Solution:
Induced e.m.f. in the generator is
ΦPN Z
Eg = .
60 A
0.02 × 4 × 1000 378
Eg = .
60 = 252 𝑉
2
Load current =V/10
Shunt current= V/100
V V 11V
Armature current = + =
10 100 100
V = Eg − armature drop
V = 252 − 1 × 11𝑉
100
V = 227 V
Load current = 227/10 = 22.7 A
Power absorbed = 227 × 22.7 = 5135 W
20 | P a g
University of Anbar
College of Engineering
Mech. Eng. Dept. Prepared by
Mohanad A. A. Alheety
ـــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــ
Losses in a D.C. Machine
The losses in a d.c. machine (generator or motor) may be divided into three classes
(i) copper losses
(ii) (ii) iron or core losses and
(iii) (iii) mechanical losses.
All these losses appear as heat and thus raise the temperature of the machine.
They also lower the efficiency of the machine.
Copper losses
These losses occur due to currents in the various windings of the machine.
(i) Armature copper loss =𝐼2 𝑅
𝑎 𝑎
21 | P a g
University of Anbar
College of Engineering
Mech. Eng. Dept. Prepared by
Mohanad A. A. Alheety
ـــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــ
(i) Hysteresis loss
Hysteresis loss occurs in the armature of the d.c. machine since any given part of the armature
is subjected to magnetic field reversals as it passes under successive poles. Fig. below shows
an armature rotating in two-pole machine.
Consider a small piece ab of the armature. When the piece ab is under N-pole, the magnetic
lines pass from a to b. Half a revolution later, the same piece of iron is under S-pole and
magnetic lines pass from b to a so that magnetism in the iron is reversed. In order to reverse
continuously the molecular magnets in the armature core, some amount of power has to be
spent which is called hysteresis loss. It is given by Steinmetz formula. This formula is:
In order to reduce this loss in a d.c. machine, armature core is made of such materials which
have a low value of Steinmetz hysteresis co-efficient e.g., silicon steel.
22 | P a g
University of Anbar
College of Engineering
Mech. Eng. Dept. Prepared by
Mohanad A. A. Alheety
ـــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــ
called eddy current loss. The eddy current loss appears as heat which raises the temperature of
the machine and lowers its efficiency
Mechanical losses
These losses are due to friction and windage.
(i) friction loss e.g., bearing friction, brush friction etc.
(ii) windage loss i.e., air friction of rotating armature.
These losses depend upon the speed of the machine. But for a given speed, they
are practically constant.
Note. Iron losses and mechanical losses together are called stray losses.
23 | P a g
University of Anbar
College of Engineering
Mech. Eng. Dept. Prepared by
Mohanad A. A. Alheety
ـــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــ
(ii) Variable losses
Those losses in a d.c. generator which vary with load are called variable losses.
The variable losses in a d.c. generator are
Power Stages
The various power stages in a d.c. generator are represented diagrammatically in the following
figure.
24 | P a g
University of Anbar
College of Engineering
Mech. Eng. Dept. Prepared by
Mohanad A. A. Alheety
ـــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــ
Mechanical efficiency
𝐵 𝐸𝑔 𝐼𝑎
𝜂𝑚 = =
𝐴 𝑀𝑒𝑐ℎ𝑎𝑛𝑖𝑐𝑎𝑙 𝑝𝑜𝑤𝑒𝑟 𝑖𝑛𝑝𝑢𝑡
Electrical efficiency
𝐶 𝑉 𝐼𝐿
𝜂𝑒 = =
𝐵 𝐸𝑔 𝐼𝑎
Commercial or overall efficiency
𝐶 𝑉 𝐼𝐿
𝜂𝑐 = = 𝑀𝑒𝑐ℎ𝑎𝑛𝑖𝑐𝑎𝑙 𝑝𝑜𝑤𝑒𝑟 𝑖𝑛𝑝𝑢𝑡
𝐴
𝜂𝑐 = 𝜂𝑒 . 𝜂𝑚
𝐼𝐿 𝑊𝐶
=√
𝑅𝑎
25 | P a g
University of Anbar
College of Engineering
Mech. Eng. Dept. Prepared by
Mohanad A. A. Alheety
ـــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــ
Ex9: A 10 kW, 250 V, d.c., 6-pole shunt generator runs at 1000 r.p.m. when delivering full-
load. The armature has 534 lap-connected conductors. Full-load Cu loss is 0.64 kW. The total
brush drop is 1 volt. Determine the flux per pole. Neglect shunt current.
Solution:
Since shunt current is negligible, there is no shunt Cu loss. The copper loss occurs in armature
only.
𝐼 = 𝐼𝑎 = 10,000/250 = 40 𝐴
Armature Cu loss = 𝐼2.𝑎𝑅 𝑎
640 = 40 . 𝑅𝑎 2
𝑅𝑎 = 0.4Ω
I𝑎𝑅𝑎 𝑑𝑟𝑜𝑝 = 0.4 × 40 = 16 𝑉
Generated e. m. f = 250 + 16 + 1 = 267 V
ΦPN Z
Eg = .
60 A
Φ × 6 × 1000 534
267 = .
60 , Φ = 30 mWb
6
Ex10: A shunt generator delivers 195 A at terminal p.d. of 250 V. The armature resistance and
shunt field resistance are 0.02 Ω and 50 Ω respectively. The iron and friction losses equal 950
W. Find (a) E.M.F. generated (b) Cu losses (c) output of the prime motor
(d) Commercial, mechanical and electrical efficiencies.
Solution:
250
𝐼𝑠ℎ = = 5𝐴; 𝐼𝑎 = 195 + 5 = 200 𝐴
50
Armature voltage drop = IaRa = 200 × 0.02 = 4 V
∴ Generated e. m. f. = 250 + 4 = 254 V
26 | P a g
University of Anbar
College of Engineering
Mech. Eng. Dept. Prepared by
Mohanad A. A. Alheety
ـــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــ
Armature Cu loss = I2Ra = 2002 × 0.02 = 800 W
�
𝑆ℎ𝑢𝑛𝑡 𝐶𝑢 𝑙𝑜𝑠𝑠 = 𝑉. 𝐼𝑠ℎ = 250 × 5 = 1250 𝑊
Total Cu loss = 1250 + 800 = 2050 W
Total losses = 2050 + 950 = 3000 W
Output = 250 × 195 = 48,750 W
Input = 48,750 + 3000 = 51750 W Output of prime motor
Electrical power produced in armature = 51,750 − 950 = 50,800 W
50,800
ηm = ( ) × 100 = 98.2%
51,750
48750
ηe = ( ) × 100 = 95.9%
48750 + 2050
48750
ηc = ( ) × 100 = 94.2%
51750
Find the load current corresponding to maximum efficiency?
Ex11: long-shunt dynamo running at 1000 r.p.m. supplies 22 kW at a terminal voltage of 220
V. The resistances of armature, shunt field, and the series field are 0.05, 110 and 0.06 Ω
respectively. The overall efficiency at the above load is 88%. Find (a) Cu losses (b) iron and
friction losses (c) the torque exerted by the prime mover
Solution:
Ish = 220/110 = 2 A
I = 22,000/220 = 100 A, Ia = 102 A
Drop in series field winding = 102 × 0.06 = 6.12 V
I2Ra
𝑎 = 1022 × 0.05 = 520.2 W
27 | P a g
University of Anbar
College of Engineering
Mech. Eng. Dept. Prepared by
Mohanad A. A. Alheety
ـــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــ
Series field loss = 1022 × 0.06 = 624.3 W
Shunt field loss = 4 × 110 = 440 W
Total Cu losses = 520.2 + 624.3 + 440 = 1584.5 W
22,000
Input = = 25,000 W
0.88
∴ Total losses = 25,000 − 22,000 = 3,000 W
∴ Iron and friction losses = 3,000 − 1,584.5 = 1,415.5 W
2πN
Power = T T = 238.74 N. m
60
Power plants, whether in d.c. or a.c. stations, will be generally found to have several smaller
generators running in parallel rather than large single units capable of supplying the maximum
peak load. These smaller units can be run single or in various parallel combinations to suit the
actual load demand. Such practice is considered extremely desirable for the following reasons
(i) Continuity of Service
Continuity of service is one of the most important requirements of any electrical apparatus.
This would be impossible if the power plant consisted only of a single unit, because in the
event of breakdown of the prime mover or the generator itself, the entire station will be shut
down.
(ii) Efficiency
Usually, the load on the electrical power plant fluctuates between its peak value sometimes
during the day and its minimum value during the late night hours. Since generators operate
most efficiently when delivering full load, it is economical to use a single small unit when the
load is light. Then, as the load demand increases, a larger generator can be substituted for the
28 | P a g
University of Anbar
College of Engineering
Mech. Eng. Dept. Prepared by
Mohanad A. A. Alheety
ـــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــ
smaller one or another smaller unit can be connected to run in parallel with the one already in
operation.
(iii) Maintenance and Repair
It is considered a good practice to inspect generators carefully and periodically to forestall any
possibility of failure or breakdown. This is possible only when the generator is at rest which
means that there must be other generators to take care of the load
(iv)Increasing plant capacity
In the modern world of increasing population, the use of electricity is continuously increasing.
When added capacity is required, the new unit can be simply paralleled with the old units.
the generators in a power plant, connected by heavy thick copper bars, called bus-bars which
act as positive and negative terminals. To connect the generators in parallel, Positive terminal
of the generators are connected to the positive terminal of the bus-bars and negative terminals
of generators are connected to negative terminal of the bus-bars, as shown in the figure.
1. To connect the 2 generators with the 1 existing working generators, first we have to
bring the speed of the prime mover of the 2nd generator to the rated speed. At this
point switch S4 is closed.
2. The circuit breaker V2 (voltmeter) connected across the open switch S2 is closed to
complete the circuit. The excitation of the generator 2 is increased with the help of
field rheostat till it generates voltage equal to the voltage of bus-bars.
29 | P a g
University of Anbar
College of Engineering
Mech. Eng. Dept. Prepared by
Mohanad A. A. Alheety
ـــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــ
3. The main switch S2 is then closed and the generator 2 is ready to be paralleled with
existing generator. But at this point of time generator 2 is not taking any load as its
induced e.m.f. is equal to bus-bar voltage. The present condition is called floating,
that means ready for supply but not supplying current to the load.
4. The main switch S2 is then closed and the generator 2 is ready to be paralleled with
existing generator. But at this point of time generator 2 is not taking any load as its
induced e.m.f. is equal to bus-bar voltage. The present condition is called floating,
that means ready for supply but not supplying current to the load.
30 | P a g
University of Anbar
College of Engineering
Mech. Eng. Dept. Prepared by
Mohanad A. A. Alheety
ـــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــ
𝐼1 = 𝐸1 − 𝑉
𝑅1
𝐸2 − 𝑉
𝐼2 =
𝑅2
Series Generators in Parallel
Suppose E1 and E2 are initially equal, generators supply equal currents and have equal shunt
resistances. Suppose E1 increases slightly so that E1 > E2. In that case, I1 becomes greater than
I2. Consequently, field of machine 1 is strengthened thus increasing E1 further whilst the field
of machine 2 is weakened thus decreasing E2 further.
A final stage is reached when machine 1 supplies not only the whole load but also supplies
power to machine 2 which starts running as a motor.
This condition can be prevented by using equalizing bar because of which two similar
machines pass approximately equal currents to the load, the slight difference between the two
currents being confined to the loop made by the armatures and the equalizer bar.
31 | P a g
University of Anbar
College of Engineering
Mech. Eng. Dept. Prepared by
Mohanad A. A. Alheety
ـــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــ
Ex12/ Two shunt generators each with an armature resistance of 0.01 ohm and field
resistance of 20 ohm run in parallel and supply a total load of 4000 A. The e.m.f.s are
respectively 210 V and 220 V. Calculate the bus-bar voltage and output of each machine.
V = bus-bar voltage
I1 = output current of G1
I2 = output current of G2
I1 + I2 = 4000 A, Ish = V/20.
V V
Ia1 = (I1 + ) ; Ia2 = (I2 + )
20 20
In each machine,
V + armature drop = induced e.m.f.
𝑉 + 𝐼𝑎1 𝑅𝑎 = 𝐸1
V
or V + (I1 + ) × 0.01
20
= 210 ...1st machine
32 | P a g
University of Anbar
College of Engineering
Mech. Eng. Dept. Prepared by
Mohanad A. A. Alheety
ـــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــ
Also V + Ia2 Ra = E2
V
or V + (I2 + ) × 0.01 = 220 … 2nd machine
20
Ex13/ Two d.c. generators A and B are connected to a common load. A had a constant e.m.f.
of 400 V and internal resistance of 0.25 Ω while B has a constant e.m.f. of 410 V and an
internal resistance of 0.4 Ω. Calculate the current and power output from each generator if the
load voltage is 390 V. What would be the current and power from each and the terminal
voltage if the load was open-circuited.
Solution:
33 | P a g
University of Anbar
College of Engineering
Mech. Eng. Dept. Prepared by
Mohanad A. A. Alheety
ـــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــ
𝑆𝑖𝑛𝑐𝑒 𝑡ℎ𝑒 terminal or output voltage is 390 V, hence
Load supplied by A = (400 − 390)/0.25 = 40 A
Load supplied by B = (410 − 390)/0.4 = 50A
∴ Power output from A = 40 × 390 = 15.6 kW
Power output from B = 50 × 390 = 19.5 kW
If the load is open-circuited as shown in figure above, then the two generators are put in series
with each other and a circulatory current is set up between them.
Net voltage in the circuit = 410 − 400 = 10 V
Total resistance = 0.4 + 0.25 = 0.65 Ω
∴ circulatory current = 10/0.65 = 15.4 A
The terminal voltage = 400 + (15.4 × 0.25) = 403.8 V
Obviously, machine B with a higher e.m.f. acts as a generator and drives machine A as a
motor.
Power taken by A from B = 403.8 × 15.4 = 6,219 W
Part of this appears as mechanical output and the rest is dissipated as armature Cu loss.
34 | P a g