Passenger Lift - Catalog Mitsubisi
Passenger Lift - Catalog Mitsubisi
Passenger Lift - Catalog Mitsubisi
Contents
Main Features 3-4
Features 11
Electrical Installation 12
(m/sec)
1.75
NEXIEZ-GPX
1.0 Type MR
1 2
Main Features
Switch Switch
LED Lighting To a specified
floor
● Advantage of LEDs
Ceiling: L500 Earthquake Emergency Return (EER-S) (Optional)
Service life (hr) Power consumption (W) When a secondary wave seismic sensor is activated, Motor
Control
all cars stop at the nearest floor and park there with the panel
LED 40000 LED 14.4 doors open to facilitate the safe evacuation of
Incandescent
2000 Incandescent passengers. Switch
lamp lamp 132
Approximately 20 times longer Approximately 88% reduction
3 4
Car Designs (1/2)
L500 N520
Ceiling: [Center] Brushed stainless-steel Ceiling: [Center] Painted steel sheet (Black)
[Sides] Painted steel sheet (Black) [Sides] Painted steel sheet (White)
Lighting: Downlights (LEDs) Lighting: [Center] Fluorescent lamp
[Sides] Downlights (LEDs)
L500
with center fan type Car Design Example
(Optional)
Car Design Example
Walls - Brushed stainless-steel
Transom panel - Brushed stainless-steel Walls - Decorative plastic finish
Doors - Brushed stainless-steel : M2-D16 [Carvalho Cinza (TX)]
Front return panels - Brushed stainless-steel Transom panel - Brushed stainless-steel
Kickplate - Brushed stainless-steel Doors - Decorative plastic finish
Flooring - M2-F06 [Roca Grafito] : M2-D16 [Carvalho Cinza (TX)]
Car operating panel - Type LCD Front return panels - Brushed stainless-steel
Kickplate - Painted steel sheet
Flooring - M2-F03 [Terrazo Crema]
Car operating panel - Type LCD
The ceiling height of the car shown in this design image is 2600mm.
N510 N530
Ceiling: [Center] Milky white acrylic panel Ceiling: [Center] Brushed stainless-steel
[Sides] Painted steel sheet (Black) [Sides] Painted steel sheet (Black)
Lighting: [Center] Fluorescent lamp Lighting: Fluorescent lamp
[Sides] Downlights (LEDs) Downlights (LEDs)
Stainless-steel
Buttons accented with LED halo illumination
Illuminated characters (CBV1), arrows (PIV1) and halos
attract user’s attention.
Brushed finish
Illumination Yellow-orange lighting Decorative plastic finish (only for Walls & doors)
color
Stainless-steel with
non-directional brushed f inish
M2-D21 M2-D07 M2-D22 M2-D23 M2-D24
Walnut Minnesota (TX) Nogal (MC) Sucupira (TX) Cherry (MC) Chang (RA)
Configuration Flooring
Vinyl tile
Location of
Elevator type*1
Code No. *2 car operating panel M2-D25 M2-D17 M2-D18
Natura (TX) Taupe (TX) Almond (TX)
Front return
Type MR All panel M2-F01 M2-F02 M2-F03 M2-F04 Painted finish
Roca Caliza Roca Ceniza Terrazo Crema Terrazo Blanco
Interior Finishes
Application Required Color No.
Brushed stainless-steel
Walls*1 Decorative plastic finish
Mirror Handrail Painted steel sheet
Brushed stainless-steel
Transom panel
Painted steel sheet
Brushed stainless-steel
Doors Decorative plastic finish
Painted steel sheet
Front return panel Brushed stainless-steel
Paint *2
Kickplate
Brushed stainless-steel
Durable vinyl tiles
Flooring Durable rubber tiles
YH-59S
Marble (Supplied by customer)
Sill Extruded hard aluminum
Stainless-steel
Brushed finish
Painted finish
Jamb - Painted steel sheet Jamb - Brushed stainless-steel M2-P06 M2-P07 M2-P08 M2-P09 M2-P10
: M2-P08 [Azul Brillante] Doors - Brushed stainless-steel Rojo Brillante Industrial Azul Brillante Verde Brillante Gris Nopal
Doors - Painted steel sheet Hall position indicator Almendra Satinado Mate
: M2-P08 [Azul Brillante] and hall button - PIV1-C710
Hall position indicator
and hall button - PIV1-A710
9 10
Features Electrical Installation
Operational and Service Features Power Feeder Data
Feature Abbreviation 1C-2BC 2C-2BC Required
Backup Operation for Car Control Microprocessor CCBK - for Type MR
Backup Operation for Group Control Microprocessor GCBK - -
Capacity Rated Motor Current at 200V Capacity of NF size in Heat
Backup Operation for Hall Control Microprocessor HCBK - speed output power supply machine room emissions
(kg) FLU (A) FLAcc (A) (A)
Car Call Canceling CCC - (m/sec) (kW) (kVA) (W)
Car Fan Shut Off – Automatic CFO-A - 450 1.0 2.8 16 26 4 20 700
Car Light Shut Off – Automatic CLO-A - 1.0 3.4 19 31 5 30 850
550
Continuity of Service COS - - 1.75 5.9 30 52 7 40 1500
Elevator remote control – Car EVRC-C 1.0 4.3 23 39 5 30 1100
700
False Call Canceling – Car Button Type FCC-P
1.75 7.6 38 65 8 40 1900
1.0 4.6 24 41 6 30 1200
Independent Service IND - 750
1.75 8.1 40 70 9 50 2050
Next Landing NXL -
Non-service Temporary Release for Car Call – Card Reader Type NSCR-C
Non-service to Specific Floors – Switch #1
NS for Type MRL
Out-of-service by Hall Key Switch HOS
Overload Holding Stop OLH - Capacity Rated Motor Current at 200V Capacity of Breaker in Heat
Safe Landing (kg) speed output power supply control panel emissions
SFL - FLU (A) FLAcc (A)
(m/sec) (kW) (kVA) (A) (W)
450 1.0 2.8 15 25 4 20 740
Group Control Features
1.0 3.7 20 34 5 30 960
Feature Abbreviation 1C-2BC 2C-2BC Required
630
1.75 6.5 33 58 7 40 1520
Forced Floor Stop FFS 1.0 5.1 25 44 6 30 1190
825
Main Floor Changeover Operation TFS
1.75 8.9 42 75 9 50 1930
Main Floor Parking MFP
FLU: current during upward operation with full load at power supply voltage of 200V.
Strategic Overall Spotting SOHS - - FLAcc: current while accelerating with full load at power supply voltage of 200V.
Door Operation Features Note: If power supply voltage (E) is a value other than 200V, FLU current and FLAcc current are obtained via the following formula.
(FLU/FLAcc current (A) at E (V)) = (Current at 200V) × (200/E (V))
Feature Abbreviation 1C-2BC 2C-2BC Required
Automatic Door Speed Control DSAC -
Door Load Detector DLD -
Door Nudging Feature – With Buzzer NDG -
Door Sensor Self-diagnosis DODA - Feeder Size Calculation
Multi-beam Door Sensor - -
Reopen with Hall Button ROHB -
Repeated Door-close RDC - ● The feeder must be able to withstand continuous flow of the following current at an ambient temperature of 40°C.
1.25 (Note) × FLU (A)
Signal and Display Features (FLU (A): current during upward operation with full load at power supply voltage of 200V)
Feature Abbreviation 1C-2BC 2C-2BC Required Note: For Type MR, the value is 1.05 for the elevator with the rated capacity 700kg or more and the rated speed 1.75m/sec.
Car Arrival Chime – Car AECC
The wire length for the feeder size must be calculated via the following formula.
Car LCD Position Indicator CID-S
Car Top Buzzer
Wire length (m) <= Coefficient* × E (V)/FLAcc (A)
CTBZ -
Emergency Alarm Bell #3 - -
(E: power supply voltage (V))
Hall LCD Position Indicator PIM-C
(FLAcc (A): current while accelerating with full load at power supply voltage of 200V)
Inter-communication System #3 ITP
*Refer to the table below for coefficients.
Voice Guidance System AAN-G
● When power is supplied to multiple elevators in a group through a common feeder, the capacity of the power supply
Emergency Operations and Features transformer, the size of the feeder, and the current rating of the no-fuse (NF) breaker for one elevator are each multiplied
Feature Abbreviation 1C-2BC 2C-2BC Required by the corresponding diversity factor below.
Earthquake Emergency Return EER-S
Emergency Car Lighting ECL - No. of elevators/group 2
Fire Emergency Return FER
Diversity factor 2.0
Firefighters’ Emergency Operation FE
Mitsubishi Emergency Landing Device MELD
Operation by Emergency Power Source – Automatic only OEPS-SA ● The current size of the grounding wire is determined according to the current rating of the NF breaker on the power source side.
● The current rating of the NF breaker on the power source side should be one level larger than that on the receiving box side
Notes: • 1C-2BC (1-car selective collective), 2C-2BC (2-car group control)
• = Standard = Optional = Not applicable in the elevator machine room or hoistway.
• #1: NS for 1C-2BC: Up to 20 stops, NS for 2C-2BC: Up to 16 stops
• #2: Cannot be combined with ITP, EMB. *
• #3: When ITP is applied, Emergency Alarm Bell is . Feeder size (mm2) 3.5 5.5 8 14 22 30 38 50 60 80 100 125 150 200 250 325
Coefficient 6.3 9.7 13.8 23.9 35.9 46.4 57.6 71.3 85 105 126 146 166 192 218 244
11 12
Entrance Layout Drawing
CO (Center Opening) 2S (Side Opening)
(Min. clearance)
(Min. clearance)
55
30
(Min. clearance)
(Min. clearance)
Sill support
(by owner)
30 91
55
Sill support
300
(by owner)
30
300
91
50
4
38
300
Wall
50
300
Finished wall
70
70
Wall
10 (by owner) 10
38
100 Entrance width: JJ 100
70
70
Finish
25
Entrance width: JJ
10
35
150 100 100 5
5 150
Finish
10
35
25
Finished
wall
E-302 E-302
91
75~113
30
55
Sill support
(by owner)
91
Sill support
(by owner)
55
20
10
30
10
30
20
Jamb depth:
4
min. 130
min. 130
depth:
Jamb
10°
140 60
60
140 60
80
140 60
° 90 30 30 150 30
25 150 30
140
30
25 150 Entrance width: JJ
Finish
Finish
30
Door plan (section B-B) Door elevation (section A-A) Door plan (section B-B) Door elevation (section A-A)
25
100
100
100
100
100
120 120 100
B B B B B B B B
Entrance height: 2100
1200
1200
1200
Finished Finished Finished Finished
floor level floor level floor level floor level
A A
A A
13 14
Basic Specifications for Type MR
Horizontal Dimensions
Hoistway Plan Machine Room Plan Hoistway Section
Machine room clear width: AM
Required R1 R3
Hoistway width: AH
Hoistway depth: BH
P6 6 450 1.0 Rear*2 1600×1750 1800×2980
2S 800 1100×1100
Side*2 1800×1530 1850×2050 □
Car internal
Ventilation
depth: BB
□
grille
CO Rear 1750×1590 1850×2900
2200
800 *1 1400×1030 Ventilator
□
R5
P8 8 550 Side 2100×1460 2100×2050 (by owner)
2S Rear*2 1600×2050 1800×3280 □
1.0 800 1100×1400 R2 R4
□
Height: 2000
Side*2 1800×1830 1850×2200
Access door
Width: 700
1.75
Rear 1750×1810 1850×3100 □
P10 10 700 CO 800 *1 1400×1250
□
Control
Side 2100×1600 2100×2050 Entrance panel
Overhead: OH
Please consult our local agents for other specifications. Power outlet (by owner)
• CO: 2-panel center opening doors, 2S: 2-panel side sliding doors.
Entrance height: HH
2100 (standard)
2300 (standard)
• Minimum hoistway dimensions (AH and BH) shown in the table are after waterproofing of the pit and do not include plumb tolerance.
Shown for CO doors
Ceiling height
[Notes]
*1: Entrance width(JJ) of 900mm is also applicable. For minimum hoistway dimensions, etc., please consult our local aqents for details. Counterweight rear drop
*2: This counterweight position or dimension is not available in some areas. Please consult our local agents for details.
Vertical Dimensions
R6
Travel: TR
Ventilation
データ不明
R4 R2
Height: 2000
Access door
Width: 700
1.0
1.0 450,
450, 550,
550, 700,
700, 750
750 60
60 4400
4400 1360
2200
2200 20 2500*1*1
2500 Control
1.75
1.75 550,
550, 700,
700, 750
750 70
70 4630
4630 1410 panel
JJ
AA Lighting outlet (by owner)
[Terms of the table]
• This table shows standard specifications without counterweight safety. Power-receiving box
(by owner)
Pit depth: PD
Please consult our local agents for other specifications.
Power outlet (by owner)
[Note]
*1: Some specifications require more than 2500mm as a minimum floor height. Please consult our local agents if the floor height is less than entrance height HH + 700mm. Shown for 2S doors
Counterweight rear drop
Reaction Loads
R5 R6
Machine room clear width: AM
Counter- Ventilation
Reaction loads(kN) AH grille Note: Hoistway section for counterweight side
weight drop is slightly different from this figure.
position
R1 R2 R3 R4 R5 R6
1400×850 21 16 21 9
Rear
BH
BB
Rear 24 19 24 10 R1 R2
1.0 61 51
Side 22 15 25 12 Lighting
1400×1030 outlet
Rear 25 17 24 10 (by owner)
1.75 61 52
Side 23 15 26 13
8 550 Power-
Rear 25 16 25 9 receiving box Control
panel
1.0 61 51 JJ (by owner)
Side 22 15 24 12
1100×1400 AA Power outlet
Rear 25 17 25 9 Ventilator
1.75 61 52 (by owner)
(by owner)
Side 22 16 25 13
Rear 26 19 26 10 Access door
1.0 68 56 Width: 700
Side 26 19 26 11 Height: 2000
10 700 1400×1250
Rear 27 20 27 11 Shown for 2S doors
1.75 70 58
Side 28 21 29 12
Counterweight side drop
1.0 29 22 29 13
11 750 1350×1400 Side 77 64
1.75 29 23 30 13
15 16
Basic Specifications for Type MRL
Horizontal Dimensions
Hoistway Plan Hoistway Section
Required
Hoistway width: AH
Hoistway depth: BH
1.75 CO 2025×1720 □ Car internal
P11 11 825 800 * 1350×1400 R6
2S 1900×1800 □ width: AA
Car internal
depth: BB
[ Terms of the table] R3
R2 R5 R1
• This table shows standard specifications without the fireproof landing door and counterweight safety.
Please consult our local agents for other specifications.
Overhead: OH
• CO: 2-panel center opening doors, 2S: 2-panel side sliding doors.
• Minimum hoistway dimensions (AH and BH) shown in the table are after waterproofing of the pit and do not include plumb tolerance.
Entrance
[Notes]
width: JJ
Entrance height: HH
*1: Entrance width(JJ) of 900mm is also applicable. For minimum hoistway dimensions, etc., please consult our local agents for details.
2100 (standard)
2300 (standard)
Ceiling height
*2: This counterweight position or dimension is not available in some areas. Please consult our local agents for details.
AH
TR <
= 30 3850*1
450, 630 1300*1
30 < TR <
= 60 3900*1
1.0
TR <
= 30 3900
825 1350
30 < TR <
= 60 3950 20 2500*2
R4
TR <
= 30 4050 1450
1.75 450, 630, 825 30 < TR <
= 60 4100 1500
60 < TR <
= 70 4150 1550 R6 AA
Travel: TR
BB
R5
BH
• This table shows standard specifications without counterweight safety. R3
Please consult our local agents for other specifications. R2 R1
[Notes]
*1: If the capacity is 630kg and marble (supplied by customer) is selected for flooring finish, the dimension may be changed. Please consult our local agents for details.
*2: Some specifications require more than 2500mm as a minimum floor height. Please consult our local agents if the floor height is less than entrance height HH + 700mm.
Pit depth: PD
8 630 1100×1400 1.0 43 32 33 26 80 68
11 825 1350×1400 1.75 48 35 35 28 92 76
R5 R6
17 18