UT Procedure
UT Procedure
sonalrach
A-CNT-CON-OOO-00282
Sub-contractor Name:CERI
Name:
Signature:
CODE DEFINITION
4 For Information
5 Void-Cancelled 1 Superseded
A-QAC-PRO-730-38939
Holds
[).c. 1:It'. if.
.... .......
•• • ...
1 11:~""it'lil !l.!I!Iïl
Page 2 of 15
Petrofac
Procedure For Ultrasonic Testing (UT)
Document No: A-QAC-PRO-730-38939
Revision B
CONTENTS
1 INTRODUCTION 4
2 SCOPE 4
3 REFERENCES 4
4 DEFINITION & ABBREVIATION 5
5 APPLICATION 5
6 PERSONNEL 5
7 EQUIPMENT 6
8 PROBES 6
9 COUPLANT 6
10 CALIBRATION BLOCKS 7
11 CALIBRATION AND SENSITIVITY SETllNGS 7
12 EXAMINATION 7
12.1 LAMINATION CHECKS 7
12.2 WELD INSPECTION 7
12.3 SIMULATION 8
12.4 RE-CALIBRATION 8
12.5 THICKNESS MEASUREMENTS 9
12.6 SURFACE CONDITION 9
12.7 Transfer correction 9
12.8 INSPECTION OF WELDS 9
12.9 EXECUTION 9
12.9.1 Scanning speed 9
12.9.2 Overlap 9
12.9.3 DEFECT SIZING AND ACCEPTABILITY 9
13 ACCETANCE CRITERIA 10
14 REPORTING 10
15 APPENDICES 10
15.1 Calibration block V1 FIGURE 1 and calibration block V2_FIGURE 2 10
15.2 DAC BLOCK _ FIGURE 3 11
15.3 TYPICAL DAC CURVE _ FIGURE 4 & TRANSFER CORRECTION_FIGURE 512
15.4 SCANNING FOR TRANSVERSE DEFECTS _ FIGURE 6 13
15.5 UT REPORT 15
~ ~~ Â
Page 3 of 15
Petrofac
il
.onolrac~
Procedure For Ultrasonic Testing (UT)
Document No: A-QAC-PRO-730-38939
Revision B
1 INTRODUCTION
ln the frame of Ain Tsila Development Project, CERI was subcontracted for site Installation
and testing of LPG Storage Sphere (730-TK-03 A & B) and Off-Spec LPG Storage Sphere
(730-TK-03 C).
2 SCOPE
This procedure applies to ail welding ultrasonic examinations during Spheres erection, nozzles
and internai piping including ail safety requirements of materials . The extent of ultrasonic
examination shall be as specified by the applicable referencing Code Section, specification
and approved ITP.
3 REFERENCES
ASME Section VIII Div. 1 : ASME Boiler And Pressure Vessel Code Code - Rules
Ed 2019 For Construction Of Pressure Vessels
ASME Section VIII Div. 2 : ASME Boiler And Pressure Vessel Code - Rules For
Ed 2019 Construction Of Pressure Vessels - Alternative Rules
ASME IX Ed 2019 : Welding , Brazing , and Fusing Qualifications
ASME V Ed 2019 : Non Destructive Examination - Requirements And
Methods
ASNT-SNT-TC-1A 2016 Personnel Qualification & Certification in Non destructive
Testing
ISO 2400:2012 Non-destructive testing - Ultrasonic testing -
Specification for calibration block No. 1
Page 4 of 15
Petrofac
Procedure For Ultrasonic Testing (UT)
Document No: A-QAC-PRO-730-38939
Revision B
5 APPLICATION
The purpose of this procedure is for ultrasonic examination of production welds including
lamination examination and thickness measurements.
6 PERSONNEL
The examination and evaluation of indication shall be done by NOT Level Il or III operators
certified according to employers written practice in accordance with SNT-TC-1A level Il or
approved equivalent as accepted by Client.
Page 5 of 15
Petrofac
Procedure For Ultrasonic Testing (UT)
Document No: A-QAC-PRO-730-38939
Revision B
7 EQUIPMENT
Examinations shall be carried out manually using the pulse-echo method with direct contact
coupling, the ultrasonic instrument shall have 'A' scan presentation with a well-defined trace to
measure both range and amplitude It may also have an optional function showing a numerical
digital display read-out to simultaneously show thickness/beam path/or % skip trigonometric
values.
Ultrasonic instruments shall be capable of working at test frequencies between 1 to 5 MHZ
Ultrasonic instruments shall be validated by client (or calibrated) annually to assure
performance to manufacturing tolerances.
Ail equipment shall be calibrated and labeled according ASME V article 5, using a reference
block for calibration according ISO 2400.
The maximum temperature difference between the Probes/Blocks used during calibration
and the test surface shall not exceed 15°C.
8 PROBES
Different type of probes may be used, depending on thickness and weld geometry, Surface
condition, Material Thickness, Material grain structure & attenuation, Test coverage required ,
Defect type/size/orientation.
Probes will be assessed daily. Compression probes shall be capable of producing at least 3
separate backwall echoes from the V1 calibration block when the first echo is at full screen
height.
Angle beam probes shall be checked for index point and beam angle. If the angle of incidence
deviates more than 2° from the normal value, then the probe will be replaced.
High temperature probes shall be used above 70°C. Temperature difference between the
calibration block and examination surfaces shall be within 25°F (14 oC).
The actual probes used during the inspection must be recorded on the test report.
9 COUPLANT
The coupling medium to be used shall be chosen to suit the test surface conditions, profile &
temperature.
For temperatures between ooe - 40°C a mixture of cellulose and water or Sound safe will be
used .
During examination of welds, the same couplant shall be used as which was used during
calibration of equipment.
Petrofac @A.
~'RJ ... ..•.
Page 6 of 15
Procedure For Ultrasonic Testing (UT)
Document No: A-QAC-PRO-730-38939
Revision B
10 CALIBRATION BLOCKS
As reference calibration block, the V1 or V2 calibration blocks shall be used as given in Figure
1 and 2.
For establishing sensitivities, a basic calibration block in accordance with DNV OS-F101
Appendix D, B 300 series (as given in figure 3) shall be used. Basic calibration block shall be
made from the project specific mate rial.
Prior to the start of the examination the horizontal and vertical linearity of the equipment shall
12 EXAMINATION
Prior to the examination of the weld the parent metal either side of the weld, where
accessible, shall be examined using 0° compressional waves over a distance of 100 mm from
the bevel. This test is to locate any laminar type defects in the parent metal, which will interfere
with or restrict the subsequent weld examination .
The parent metal scan sensitivity shall set at 2nd Back Wall Echo (BWE) to Full Screen
Height (FSH) .
Scan coverage shall include the entire area of parent material that will undergo a shear
wave interrogation . That extent is equal to the ~ or full skip distance plus ~ the weld
Page 7 of 15
Petrofac
Procedure For Ultrasonic Testing (UT)
Document No: A-QAC-PRO-730-38939
Revision B
The skip distances are calculated for the shallowest angle probe to be used and the
choice of % or full skip is dependent on whether access for scanning is from one side, or from
Skip distance can be calculated as shown and be used to confirm the extent of parent
The echo height from position A shall be maximized and the gain control regulated so that the
echo height is 75% (+/- 5%) of full screen height. This gain setting is ca lied the primary gain
and shall be recorded. Without altering this gain setting, the maximized echo height from points
Band C shall be plotted on the screen.
The reference curve is now to be drawn as a smooth line through the three points. Curves
being respectively 20% and 50% of the reference curve shall also be constructed.
12.3 SIMULATION
When the sensitivity has been established, this sensitivity may be correlated to the drilled hole
During the operation on site the V1 or V2 block will be utilized to confirm the operational
sensitivity if necessary.
12.4 RE-CALIBRATION
At the end of the examination, or every four hours, or change of operator, and whenever a
malfunction of the equipment is suspected, calibration must be checked. Re-calibration shall
also be done if any part of equipment is changed or replaced or equipment switched on-off.
If a point on the DAC has increased more than 2 dB of its amplitude, ail recorded indications
since the last check shall be re-examined with the corrected calibration. If a point on the DAC
has decreased more than 2 dB of its amplitude , ail examination covered since the last
calibration shall be Re-examined with the corrected calibration .
ln addition to this, a daily control shall be done in the following way . Indication set at 80% FSH
then decrease the amplitude -12 dB with the dB control. Obtained indication limits 16-24% of
FSH. If indication is outside the Iimits, the instrument shall be removed from use. This shall be
logged daily by operator.
Page 8 of 15
Petrofac
Procedure For Ultrasonic Testing (UT)
Document No: A-QAC-PRO-730-38939
Revision B
2).
The time base shall be calibrated to enable a minimum of five back wall echoes from the
sarnple to be displayed . For better accuracy, calibration and wall thickness readings will be
The welds shall be examined in such a manner that the entire weld volume is scanned. Where
100 % weld examination is required, the method of scanning for transverse defects is given in
figure 6.
The scanning sensitivity is the corrected primary reference level (DAC+any applicable transfer
correction) + 6 dB, discontinuities however, shall be evaluated using the corrected primary
reference level.
12.9 EXECUTION
12.9.2 Overlap
Each pass of the probe shall overlap a minimum of 15% of the transducer (piezo electric
element) dimension perpendicular to the direction of the scan .
Defects will be sized for dimensional evaluation using the 6 dB drop or maximum amplitude
methods.
Page 9 of 15
Petrofac
Procedure For Ultrasonic Testing (UT)
Document No: A-QAC-PRO-730-38939
Revision B
Only indications with an echo height of 20 % DAC and above will be investigated to their nature
and extent. Acceptance criteria for manual LIT are based on ASME V"I Div. 2.
/\ny indication of crack like nature will be itlllïleûi8l~ly r~fJurled lu the client's representatlve,
regardless of echo height. A" indication with amplitudes of 50% FSH or above sha" be reported
with minimum details as given below. A" areas starving drop of back wall echo to less than
13 ACCETANCE CRITERIA
Acceptance criteria sha" be as per ASME V"I Div2. Parg 7.5.4
14 REPORTING
15 APPENDICES
Petrofac Qj,&
~ERI .••....•.
Page 10 of 15
Procedure For Ultrasonic Testing (UT)
Document No: A-QAC-PRO-730-38939
Revision 8
._--------..
1": «m ul',~
..;.;-. ~~, .
. - - - -....
:-- . -po
~
1
~' l , l, l, l, r, l , l, l', l, ,.., 1":', , l, l ,,] ,Id, l, l, P.
Î , ,
,
\ ./
V1~
I!
\1: •••
"
2~ .S
/ '; '.1
/
- ··i~I<:·;;Ii~ =12.5 u' le
Il'-~~NlP. ''),,-~r-1 ~ <II S
"'1I31~;' l,r"l.
Page 11 of 15
Petrofac
Procedure For Ultrasonic Testing (UT)
Document No: A-QAC-PRO-730-38939
Revision B
'-i!lJ.~~
-t..•...__._-._ V2
...!
rnininHJm
38 mOl
40 mm
10
100mm
Lenglh $t.ilahIH ror U"l'P. sound bP.~rT1 palh ror ail rnlb (~ Iype~ i'J nd lhf"! rnalf·ui;.11 on~ngjuns 10 bH lf'$Ip.d
f:>Jll/'l
Transmitter Receiver
Reference black
Transmitter Receiver
A = Difference (xdB.)
owing 10 difference
in surface and
allenualion.
Page 13 of 15
Petrofac ~A,.~
~ERI ..." •.
Procedure For Ultrasonic Testing (UT)
Document No: A-QAC-PRO-730-38939
Revision B
\Veld width
Notes:
1) Direction of probe movement parallel to weld axis
2) Scanning to be carried out on both sides of weld
3) Probe oscillation through 10 0 during movement along
4) Use 45 0 and 60 0 probe angles.
Page 14 of 15
Petrofac
Procedure For Llltrasonic Testing (UT)
Document No: A-QAC-PRO-730-38939
Revision B
15.5 UT REPORT
W-01 12X
Sub Contractar Code
1 1 1
1
1 1
UT Instrument
ktentfficatlon JMake: Model : Seriai Number: Couplant us.ed (Brand Name or Type):
O'
,.
...
,..
Data correlatJng slmulallon bloek (5) and etoruonle slmu'ator{s). who"
IdentJf1callon;
uscd, wllh InlUal callbrallon
Simulauan
C:lUbraUon Block ID Elocltonic shnulltot(s)
Block (sI
V1 ASUE SOH Bloçk lh1cknClU _ mm -
V2 Roforonoa Rolloctor: SOH mm dl. -
Subcontractor QC
Record Acceptance vrvac Pctrofac QC Company
Name
Signature
Date
pago 1 012 Rcl. ITP No.; PEC.QlJ.ITP-X-l0821
Page 15 of 15