Cri Motores
Cri Motores
Cri Motores
C.R.I. MOTORS
T H E B E G I N N I N G
of C.R.I., way back in 1961, was a resolute attempt to produce a few
irrigation equipments using the limited facilities of an in-house foundry.
Eventually the founder's dream was coming true as the small
production unit he started kept growing rapidly. Now, after more than
five eventful decades, it is an enormous, widely reputed organization,
which produces more than 2300 varieties of perfectly engineered
pumps and motors and sells its products in numerous countries spread
across 6 continents.
C . R . I . I S O N E A M O N G
THE INFRASTRUCTURE
of C.R.I. is pretty comprehensive with state-of-the-art machineries
and high potential in-house R&D recognised by the ministry of
science and technology, Govt. of India - all within its own covered area
of 300,000 square metres. The production environment is accredited
with ISO 9001, ISO 14001 & OHSAS 18001 certifications and the
products are CE, UR/UL, IEC, TSE & ISI certified. The R&D team
always stays in tune with the changing scenario and seldom fails in
coming up with outstanding solutions every time.
N E E D L E S S T O S A Y ,
C.R.I. MOTORS
PageNo.
M O D E L I D E N T I F I C AT I O N C O D E 3
R E S I N F I L L E D E N C A P S U L AT E D S U B M E R S I B L E M O T O R S
4" Motors
D e s c r i p t i o n , Fe a t u r e s a n d A p p l i c a t i o n s 4
Specifications and Materials of Construction 5
E x p l o d e d V i ew 6
Te c h n i c a l D a t a 7
R E S I N F I L L E D E N C A P S U L AT E D S U B M E R S I B L E M O T O R S
D e s c r i p t i o n , Fe a t u r e s a n d A p p l i c a t i o n s 8
4" Motors
Specifications and Materials of Construction 9
E x p l o d e d V i ew 10
Te c h n i c a l D a t a 12
6" Motors
Specifications and Materials of Construction 14
Te c h n i c a l D a t a 15
W AT E R F I L L E D R E W I N D A B L E S U B M E R S I B L E M O T O R S
D e s c r i p t i o n , Fe a t u r e s & A p p l i c a t i o n s 16
E x p l o d e d V i ew 17
4" Motors
Specification and Materials of Construction 23
Te c h n i c a l D a t a 24
6" Motors
Specifications and Materials of construction 25
Te c h n i c a l D a t a 26
8" Motors
Specifications and Materials of Construction 29
Te c h n i c a l D a t a 30
10" Motors
Specifications and Materials of Construction 31
Te c h n i c a l D a t a 32
12" Motors
Specifications and Materials of Construction 33
Te c h n i c a l D a t a 34
C a bl e S e l e c t i o n Ta bl e 35
C o nve r s i o n Ta bl e 38
Pumping trust. Worldwide. C.R.I. MOTORS
X X X S XXX XX X X M (H)(P)
In view of continuous developments, the information / descriptions / specifications / illustrations are subject to change without notice.
3
COMMITMENT RELIABILITY INNOVATION
Deepstar
Description
These oil filled motors are one among the proven & successful products from the house of C.R.I. These motors are developed
with due diligence complying with all safety standards and giving importance to the customers' need. All the components that
are in contact with water are made of AISI 304 stainless steel and the motor is pre-filled with edible grade oil, which acts as
coolant media as well as lubricant. The freezing point of the oil used is -10°C.
Ball bearings are used to withstand the high axial load and the lower ball bearings are of angular contact type.
High quality carbon/ceramic mechanical seal and oil seal made of Nitrile rubber are used to ensure better sealing system.
Pressure equalizing rubber diaphragm is provided to balance the pressure and volume variations due to thermal expansion
of the oil inside the motor. Motor sealing are made by means of ‘O’ rings. Shaft seals and sand guard prevents ingress of well
water, sand and fiber particles into the motor. Care should be taken to ensure that the motor does not run when it is not
submerged in the water. To prevent the motor from dry running, install water level monitor / dry run prevent. The motor needs a
constant flow of water passed over it’s body to keep it at correct operating temperature. Ideally the motors should be set just
above the final yield point of bore well and when the level is not ascertained, fit a “flow inducer pipe” over the pumpset to
ensure adequate cooling. It is mandatory to use C.R.I. Control boxes for all motors with adequate protection & control
systems. Mounting dimensions of these motors are in accordance with NEMA standard.
Features
Applications
These prime mover submersible motors are suitable to couple with deepwell submersible pump ends used for
In view of continuous developments, the information / descriptions / specifications / illustrations are subject to change without notice.
4
Pumping trust. Worldwide. C.R.I. MOTORS
Deepstar
Specifications
Nominal Dia 4” (100mm)
Maximum Outer Diameter 3.74"
0.5 HP to 3 HP - Single Phase
Power Range
0.5 HP to 10 HP - Three Phase
Speed 3450 rpm
Single Phase - 110 V & 220 V, 60 Hz, A.C Supply
Version
Three Phase - 220 V, 380 V & 460 V, 60 Hz, A.C Supply
Class of Insulation F
Degree of Protection IP 68
CCW - Single Phase
Direction of Rotation
Electrically Reversible - Three Phase
Type of Duty S1 (Continuous)
0.5 HP to 1 HP - 337 lbs
Down Thrust Load 1.5 HP to 4 HP - 562 lbs
5 HP to 10 HP - 1011 lbs
Minimum Cooling Flow Along the Motor 0.5 ft/sec
Maximum Liquid Temperature 91.4°F
Maximum Immersion Depth 150 m
Starts per Hour 30 Times
Shaft Type Splined as per NEMA Standard
Mounting Standard NEMA Standard
Single Phase - Permanent Split Capacitor (PSC)
Method of Starting
Three Phase - Direct On Line (DOL)
Cable Lead out 3 Wire Permanent Type TPE/EPDM Rubber Flat Cable
Type - A
Materials of Construction
Part Name Type - A
In view of continuous developments, the information / descriptions / specifications / illustrations are subject to change without notice.
5
COMMITMENT RELIABILITY INNOVATION
Deepstar
Exploded View
In view of continuous developments, the information / descriptions / specifications / illustrations are subject to change without notice.
6
Pumping trust. Worldwide. C.R.I. MOTORS
Deepstar
110V, SINGLE PHASE ELECTRICAL & DIMENSIONAL DATA
Capacitor MFD Amps Max Down Height H1 Nett Weight
PF Cable Size
Models kW HP S.F. EFF.% Thrust
Cosf (sq.mm)
Starting Running F.L Starting load (lbs) mm Inches kg lbs
In view of continuous developments, the information / descriptions / specifications / illustrations are subject to change without notice.
7
COMMITMENT RELIABILITY INNOVATION
Description
These motors are hermetically sealed, encapsulated and water lubricated type with removable cable lead out. The stator
windings are of enameled copper wire and the wound stator is mounted in a stainless steel shell and is completely protected by
a stainless steel cylinder and stator room is pre-filled with resin. The resin filled in the space between the stator & the stainless
steel cylinder dissipates heat quickly resulting in longer motor life. Except stator, other portions of the motor is pre-filled with
deionised water containing propylene glycol (anti-freeze agent) which serves as coolant & lubricant for rotor, bushes and thrust
bearing. Dynamically balanced rotors of these motors maintain uniform clearance thereby giving better efficiency and increase
the life cycle of the water lubricated bush bearings. Specially designed high performance thrust bearings are used that can
withstand high axial thrust loads and upthrust loads with minimum wear and tear.
The unique design of thrust bearings creates a wedge of water between the shoe and the disc and thereby providing better
water lubrication and increases the life cycle of the thrust bearings. Pressure equalizing rubber diaphragm is provided to guard
the pressure and volume variations due to thermal expansion of the water inside the motor. Motor sealing are made by means
of ‘O’ rings. Shaft seals and sand guard prevents ingress of well water, sand and fiber particles into the motor. Care should be
taken to ensure that the motor does not run when it is not submerged in the water. To prevent the motor dry running, install
water level monitor / dry run preventor. The motor needs a constant flow of water past it’s body to keep it at correct operating
temperature. Ideally, the motor should be set just below the level at which water enters the bore well. When this level is not
ascertained, fit a “flow inducer sleeve” over the pumpset to ensure adequate cooling. It is mandatory to install C.R.I. Control
box for all single phase 3 wire motors. All 3 Ph motors require an adequate motor protection control panel. Mounting
Features
Corrosive resistant stainless steel body.
Specially designed thrust bearing to withstand high axial thrust loads.
Low watt loss silicon steel laminations for better starting torque.
Higher power factor resulting in lesser power consumption.
Better heat dissipation for prolonged life cycle.
All single phase two wire motors are supplied with in-built permanent split capacitor.
Optional : All single phase models are also available with lightening arrester.
Applications
These prime mover submersible motors are suitable to couple with deepwell submersible pumpends used for :
In view of continuous developments, the information / descriptions / specifications / illustrations are subject to change without notice.
8
Pumping trust. Worldwide. C.R.I. MOTORS
Specifications
Nominal Dia 4” (100mm)
Maximum Outer Diameter 3.74"
0.5 HP to 1.5 HP - Single Phase 2 Wire
Power Range 0.5 HP to 5 HP - Three Phase 3 Wire
0.5 HP to 10 HP - Three Phase 3 Wire
Speed 3450 rpm
Single Phase - 110 V, 220 V, 60 Hz, A.C Supply
Version
Three Phase - 220 V, 380 V & 460 V, 60 Hz, A.C Supply
Class of Insulation B
Degree of Protection IP 68
CCW - Single Phase
Direction of Rotation
Electrically Reversible - Three Phase
Type of Duty S1 (Continuous)
0.5 HP to 0.75 HP - 300 lbs
Down Thrust Load 1 HP to 2 HP - 650 lbs
3 HP to 10 HP - 1500 lbs
Minimum Cooling Flow Along the Motor 0.25 ft/sec
Maximum Liquid Temperature 91.4°F
Starts per Hour 20 Times
Shaft Type Splined as per NEMA Standard
Mounting Standard NEMA Standard
Single Phase-3 Wire - Capacitor Start Capacitor Run (CSCR)
Method of Starting Single Phase-2 Wire - Permanent Split Capacitor (PSC)
Three Phase - Direct On Line (DOL) 3 Wire 2 Wire
Cable Lead out 2 & 3 Wire Removable Type TPE Flat Cable
Materials of Construction
Part Name Type - A
In view of continuous developments, the information / descriptions / specifications / illustrations are subject to change without notice.
9
COMMITMENT RELIABILITY INNOVATION
Exploded view
13.03
14.04
32.14
32.07
32.13
24.02
32.15
14.07
13.00
14.05
32.05
32.08
11.04
32.11
32.09 11.06
32.24
11.00
Part No. Part Name
14.00
12.03
10.00 Motor base
10.02 Diaphragm
32.09 10.04 Diaphragm guide plate
32.19 11.00 Thrust Base
11.04 Thrust Pad
11.09 11.06 Thrust segment
12.03 11.09 Rocker screw
12.00 12.00 Lower housing
12.03 Bush
14.01
13.00 Rotor
13.03 Upthrust washer
14.00 Upper housing
32.19
14.01 Cable grommet clamp
14.04 Rubber sand guard
10.04 14.05 Sand guard
14.07 Upper housing shell
21.01 Wound stator
24.01 10.02
24.02 Lead out cable
32.05 Pad key
32.07 Nut
10.00 32.08 Oil seal
32.09 O - Ring
32.16 32.11 Drain Plug
32.12 32.12 Screw
32.13 Sand guard washer
32.19 32.14 Spring washer
32.15 Stud
32.16 Washer
32.19 Gasket
32.24 Vent plug
In view of continuous developments, the information / descriptions / specifications / illustrations are subject to change without notice.
10
Pumping trust. Worldwide. C.R.I. MOTORS
Exploded view
14.04
32.14 11.04
32.07 32.13
24.02
32.15
32.19
11.06
14.07 11.00
14.05
13.03
32.08 32.09
32.11
32.09 11.01
32.24
Part No. Part Name
32.09
14.00 32.12
10.00 Motor base
13.00 11.09 10.02 Diaphragm
10.04 Diaphragm guide plate
32.05 11.00 Thrust Base
32.19
32.19 11.01 Thrust base housing
11.04 Thrust Pad
11.06 Thrust segment
12.03 10.04
11.09 Rocker screw
12.03 12.00 Lower housing
14.01 10.02 12.03 Bush
13.00 Rotor
13.03 Upthrust washer
14.00 Upper housing
10.00
32.09 14.01 Cable grommet clamp
14.04 Rubber sand guard
32.16
14.07 Upper housing shell
32.12 24.01 Wound stator
24.02 Lead out cable
24.01 32.05 Pad key
12.00 32.07 Nut
32.08 OIl seal
32.09 O - ring
32.11 Drain plug
32.12 Screw
32.13 Sand guard washer
32.14 Spring washer
32.15 Stud
32.16 Washer
32.19 Gasket
32.24 Vent plug
In view of continuous developments, the information / descriptions / specifications / illustrations are subject to change without notice.
11
COMMITMENT RELIABILITY INNOVATION
110 V & 220V, SINGLE PHASE, 2 WIRE MOTORS TECHNICAL & ELECTRICAL DATA
Rated (F.L.) Maximum (S.F.) Eff. % P.F. % Locked Max. Down
Capacitor
Models Voltage HP S.F. Rotor Thrust Load
Amps Watts Amps Watts S.F. F.L. S.F. F.L. Value µf
Amps (lbs)
R4AS-05-2A 110V 0.5 1.6 7.1 753 9.2 980 60 50 97 97 32 300 50
R4AS-07-2A 110V 0.75 1.5 10 1100 12.7 1395 61 52 99 99 43 300 60
R4AS-10-2A 110V 1 1.4 12.1 1313 15 1640 64 57 98 99 55 650 80
R4AS-05-2D 220V 0.5 1.6 3.4 730 4.3 960 62 51 97 92 18 300 25
R4AS-07-2D 220V 0.75 1.5 4.7 998 5.8 1300 61 56 95 92 25 300 30
R4AS-10-2D 220V 1 1.4 6.2 1306 7.5 1650 63 57 95 91 33 650 35
R4AS-15-2D 220V 1.5 1.3 9 1931 10.5 2300 65 62 97 95 45 650 45
110 V & 220V, SINGLE PHASE, 3 WIRE MOTORS TECHNICAL & ELECTRICAL DATA
Rated (F.L.) Maximum (S.F.) Eff. % P.F. % Locked Max. Down Capacitor Value µf
Models Voltage HP S.F. Rotor Thrust Load
Amps Watts Amps Watts S.F. F.L. S.F. F.L. Amps (lbs) Start Run
R4AS-05-3A 110V 0.5 1.6 8.5 760 11.5 1120 54 50 88 82 36 300 125 20
R4AS-07-3A 110V 0.75 1.5 10.3 1027 14.5 1450 57 55 91 90 46 300 125 30
R4AS-10-3A 110V 1 1.4 12 1186 16 1620 64 63 93 90 58 650 150 40
R4AS-05-3D 220V 0.5 1.6 4.2 796 5.5 1120 54 50 76 62 23 300 60 10
R4AS-07-3D 220V 0.75 1.5 5.3 1141 6.9 1550 61 56 75 64 32 300 60 15
R4AS-10-3D 220V 1 1.4 6.4 1412 8.3 1825 63 57 73 62 39 650 100 20
R4AS-15-3D 220V 1.5 1.3 8.8 1994 11.5 2390 65 62 86 82 46 650 100 20
R4AS-20-3D 220V 2 1.15 10.7 2236 12.3 2453 70 66 93 92 54 650 125 30
R4AS-30-3D 220V 3 1.15 15.5 3530 18.5 4035 69 69 97 97 85 1500 150 45
R4AS-50-3D 220V 5 1.15 25.5 5770 31 6634 69 69 98 98 120 1500 250 80
In view of continuous developments, the information / descriptions / specifications / illustrations are subject to change without notice.
12
Pumping trust. Worldwide. C.R.I. MOTORS
In view of continuous developments, the information / descriptions / specifications / illustrations are subject to change without notice.
13
COMMITMENT RELIABILITY INNOVATION
Specifications
Nominal Dia 6” (150mm)
Maximum Outer Diameter 5.62"
Power Range 5 HP to 60 HP - Three Phase
Speed 3450 rpm
Version Three Phase - 230 V, 380 V & 460 V, 60 Hz, A.C Supply
Class of Insulation F
Degree of Protection IP 68
Direction of Rotation Electrically Reversible
Type of Duty S1 (Continuous)
5 HP to 30 HP - 3485 lbs
Down Thrust Load
40 HP to 60 HP - 6182 lbs
Minimum Cooling Flow Along the Motor 0.52 ft/sec
Maximum Liquid Temperature 5 HP to 40 HP - 86°F, 50 HP & 60 HP - 122°F
Starts per Hour 20 Times
Shaft Type Splined as per NEMA Standard
Mounting Standard NEMA Standard
Three Phase - Direct On Line (DOL)
Method of Starting
Three Phase - Star Delta (SD)
Cable Lead out 3 Wire Removable Type TPE Flat Cable
Materials of Construction
Part Name Type - A
In view of continuous developments, the information / descriptions / specifications / illustrations are subject to change without notice.
14
Pumping trust. Worldwide. C.R.I. MOTORS
Nominal Diameter : 4", 6", 8", 10" & 12" "W" Series
Wellrounder
Description
These motors are eco-friendly, wet type, water filled and rewindable. The stator windings are of water proof synthetic film
insulated copper winding wires. It features water lubricated thrust and journal bearings. Motor is pre-filled with clear, cold,
pure, fresh, filtered propylene glycon (anti-freez agent) mixed water. Before commissioning, ensure the pre-filled level of
water inside the motor. If any loss of volume is noticed, refill with clear, cold, pure, fresh, filtered water, through water filling
plugs / valves provided in the upper housing. Where the use of anti-freeze agent mixed water is not be allowed for special
applications, these motors can also be filled with clear, cold, pure, fresh, filtered water and operated. Dynamically balanced
rotors maintains uniform clearance thereby giving better efficiency and increase the life cycle of the water lubricated bush
bearings. Specially designed high performance thrust bearings are used to withstand high axial thrust loads and up thrust
loads with minimum wear and tear.
The unique design of thrust bearings create a wedge of water between the shoe and the disc, and thereby providing better
water lubrication and increases the life cycle of the thrust bearings. Pressure equalizing rubber diaphragm is provided to
balance the pressure and volume variations of the water inside the motor. Motor sealing are made by means of ‘O’ rings.
Shaft seals and sand guard prevents ingress of well water, sand and fiber particles into the motor. Care should betaken to
ensure that the motor does not run when it is not submerged in the water, To prevent the motor from dry running, install water
level monitor/dry run preventor. The motor needs a constant flow of water passed over it’s body to keep it at correct operating
temperature. Ideally the motors should be set just above the final yield point of bore well and when the level is not
ascertained, fit a “flow inducer pipe” over the pumpset to ensure adequate cooling. It is mandatory to use C.R.I. Control
boxes for all motors with adequate protection & control systems. Mounting dimensions of these motors are in accordance
with NEMA standard.
Features
Applications
These prime mover submersible motors are suitable to couple with deepwell
submersible pumpends used for
Residential Pressure boosting units Oil & Gas
Irrigation Gardens De-watering
Fountains Sprinkler systems CBM (Coal bed methane)
Industrial water supply Mining Mining
In view of continuous developments, the information / descriptions / specifications / illustrations are subject to change without notice.
16
Pumping trust. Worldwide. C.R.I. MOTORS
32.07 29.04
14.17 10.06
14.16
14.04
14.01
14.07
32.15
32.11
10.00
24.01 32.00
In view of continuous developments, the information / descriptions / specifications / illustrations are subject to change without notice.
17
COMMITMENT RELIABILITY INNOVATION
Wellrounder
Exploded view
32.07 24.02
24.04
14.17
14.16
14.04
14.01
14.07
32.12
14.02 24.01
14.01
32.00
32.11
18 In view of continuous developments, the information / descriptions / specifications / illustrations are subject to change without notice.
Pumping trust. Worldwide. C.R.I. MOTORS
Wellrounder
Exploded view
12.03
13.03
12.00
14.04
32.23
32.07 Part No. Part Name
32.09
10.06 10.05
In view of continuous developments, the information / descriptions / specifications / illustrations are subject to change without notice.
19
COMMITMENT RELIABILITY INNOVATION
Wellrounder
Exploded view
32.19
32.07
12.03
12.00
32.15
12.05
32.19
32.12
11.04
14.04
32.01
16.04 11.06
11.00 Part No. Part Name
In view of continuous developments, the information / descriptions / specifications / illustrations are subject to change without notice.
20
Pumping trust. Worldwide. C.R.I. MOTORS
Wellrounder
Exploded view
14.04 13.12
16.02
32.07
16.00
32.16
13.12 32.15
16.02
35.00
35.01 32.11
14.02 32.09
14.11
14.10 35.02
14.11
14.12 35.01
32.19 14.00
12.03
32.07
In view of continuous developments, the information / descriptions / specifications / illustrations are subject to change without notice.
21
COMMITMENT RELIABILITY INNOVATION
Wellrounder
Exploded view
32.12
16.02
32.09
32.11
15.00 32.09
32.15 32.11 11.06
32.14 32.09
32.16 11.05
16.00 32.09
32.10
32.16
32.01
33.02 11.10
14.00
32.05 32.16 32.07
32.12
11.03
32.15 Part No. Part Name
32.15
32.07 10.00 Motor base
10.02 Diaphragm
11.01 Thrust base housing
11.11 11.03 Thrust bearing bottom
11.04 Thrust Pad
13.00 11.05 Ball
32.09 11.06 Thrust segment
11.08 Rocker screw nut
24.01
32.15 11.09 Rocker screw
11.10 Ball guide ring
11.09 11.11 Thrust bearing base plate
11.08 12.00 Lower housing
12.03 Bush
32.05 11.01 13.00 Rotor
13.03 Upthrust Washer
32.12 14.00 Upper housing
13.03 15.00 Seal housing
16.00 Mechanical seal
12.03 32.16 16.02 Mechanical seal clamp plate
11.04
24.01 Wound stator
32.01 10.02 32.01 Circlip
32.05 Key
32.09 32.07 Nut
32.09
32.09 O - Ring
32.10 Segment guide pin
32.11 Drain plug
12.00 10.00
32.12 Screw
32.15 Stud
33.02 32.09 32.16 Washer
32.23 Tie rod
32.15 33.02 Bolt
In view of continuous developments, the information / descriptions / specifications / illustrations are subject to change without notice.
22
Pumping trust. Worldwide. C.R.I. MOTORS
Wellrounder
Specifications
Nominal Dia 4” (100mm)
Maximum Outer Diameter 3.81"
Power Range 0.5 HP to 10 HP - Three Phase
Speed 3450 rpm
Version Three Phase - 220 V, 380 V & 460 V, 60 Hz, A.C Supply
Class of Insulation Y
Degree of Protection IP 58
Direction of Rotation Electrically Reversible
Type of Duty S1 (Continuous)
0.5 HP to 2 HP - 800 lbs
Down Thrust Load
3 HP to 10 HP - 1500 lbs
Minimum Cooling Flow Along the Motor 0.25 ft/sec
Maximum Liquid Temperature 91.4°F
Starts per Hour 20 Times
Shaft Type Splined as per NEMA Standard
Mounting Standard NEMA Standard
Method of Starting Three Phase - Direct On Line (DOL)
Permanently Connected and Sealed 3/4 Core
Cable Lead out
TPE/EPDM Rubber Flat Cable Type - A/N
Materials of Construction
Part Name Type - A Type - N
220, 380 & 460V, THREE PHASE DIMENSIONS & WEIGHT DATA
Lead Out Cable (Sq.mm) Height H1 Nett Weight Approx.
Motor Model HP
220 V 380 V 460 V mm Inches kg lbs
W4A-05-4 0.5 1.5 1.5 - 432 17.0 14.2 31.4
W4A-07-4 0.75 1.5 1.5 - 472 18.6 16.3 35.9
W4A-10-4 1 1.5 1.5 - 502 19.8 17.8 39.2
W4A-15-4 1.5 2.5 1.5 - 560 22.0 20.8 45.8
W4A-20-4 2 2.5 1.5 - 715 28.1 27 59.2
W4A-30-4 3 2.5 1.5 1.5 725 28.5 32 70.4
W4A-40-4 4 2.5 1.5 1.5 890 35.0 36 79.0
W4A-50-4 5 4.0 2.5 2.5 965 37.9 39.7 87.4
W4A-60-4 6 4.0 2.5 2.5 1143 45.0 43.2 95.2
W4A-75-4 7.5 4.0 2.5 2.5 1320 52.0 46.8 103.0
W4A-100-4 10 4.0 2.5 2.5 1422 56.0 47.7 105.0
The last digit of the model number denotes voltage (D = 220V, E = 230V, I = 380V, M = 460V).
In view of continuous developments, the information / descriptions / specifications / illustrations are subject to change without notice.
23
COMMITMENT RELIABILITY INNOVATION
Wellrounder
45° STUD (M8 x 1.25), 4 Nos.,
EQUISPACED ON PCD 76.2
(12.7mm) Min.
RATED MAX. S.F. Efficiency % Power Factor% Locked Thrust
Ø1.37” (35mm)
MODEL HP SF Rotor Capacity Ø1.22” (31mm)
Amps W Amps W S.F F.L. 3/4 S.F F.L 3/4 Amps (lbs) Ø0.61” (15.55mm)
0.5”
0.5 664
(38mm)
W4A-05-4D 1.6 2.3 3.1 928 59 56 51 80 75 70 15 800
1.49”
W4A-07-4D 0.75 1.5 3.6 928 4.3 1264 65 63 57 79 75 64 21 800
W4A-10-4D 1 1.4 4 1136 5.5 1600 68 66 60 80 75 68 25 800
W4A-15-4D 1.5 1.3 5.5 1648 7.3 2032 70 69 65 80 77 71 34 800
Ø3.81”
2 2280 (97mm)
W4A-20-4D 1.25 8 9.6 2600 71 69 66 78 75 71 44 800
W4A-30-4D 3 1.15 10.4 3120 12 3720 72 72 68 80 78 74 58 1500
W4A-40-4D 4 1.15 15 4160 16.8 4720 71 73 70 78 73 70 75 1500
H1 (HEIGHT)
W4A-50-4D 5 1.15 16.3 4880 19.5 6200 76 75 71 81 79 72 97 1500
W4A-60-4D 6 1.15 19.4 6040 23 6820 76 75 73 82 80 70 115 1500
W4A-75-4D 7.5 1.15 22 7280 27.5 8400 76 75 74 83 80 78 137 1500
In view of continuous developments, the information / descriptions / specifications / illustrations are subject to change without notice.
24
Pumping trust. Worldwide. C.R.I. MOTORS
Wellrounder
Specifications
Nominal Dia 6” (150mm)
Maximum Outer Diameter 5.62"
Power Range 5 HP to 60 HP - Three Phase
Speed 3450 rpm
Version Three Phase - 220 V, 380 V & 460 V, 60 Hz, A.C Supply
Class of Insulation Y
Degree of Protection IP 58 / IP 68
CCW - Single Phase
Direction of Rotation
Electrically Reversible - Three Phase
Type of Duty S1 (Continuous)
5 HP to 30 HP - 3500 lbs
Down Thrust Load
35 HP to 60 HP - 6000 lbs
Minimum Cooling Flow Along the Motor 0.5 ft/sec
Maximum Liquid Temperature 91.4°F
Starts per Hour 20 Times
Shaft Type Splined as per NEMA Standard
Mounting Standard NEMA Standard
Three Phase - 5 HP to 60 HP - Direct On Line (DOL)
Method of Starting
Three Phase - 7.5 HP to 60 HP - Star Delta (SD)
Permanently Connected and Sealed 3/4 Core PVC / Rubber
Cable Lead out
Insulated Flat Cable
High Temperature Motors for 158°F / 194°F can be supplied
Thermal Protection
with PT Sensor and XLPE / PA Winding
* On request motors 440 & 690V can be supplied.
Materials of Construction
Part Name Type - A Type - N
In view of continuous developments, the information / descriptions / specifications / illustrations are subject to change without notice.
25
COMMITMENT RELIABILITY INNOVATION
Wellrounder
)
m
m
1.5 45°
” (5
02
2.
220V, THREE PHASE DIMENSIONS & WEIGHT DATA
(72.8mm)
924 36.3 63.6 140
(30mm)
2.86”
1.18”
W6A-200-4D 20 10 1004 39.5 72.7 160
W6A-250-4D 25 16 1084 42.6 81.3 179
W6A-300-4D 30 16 1154 45.4 90.9 200
W6A-400-4D 40 16 1229 48.3 93.6 206
The above mentioned electrical data are applicable for Star-Delta motors also
Note: Star-Delta motors are available from 7.5 H.P. onwards.
In view of continuous developments, the information / descriptions / specifications / illustrations are subject to change without notice.
26
Pumping trust. Worldwide. C.R.I. MOTORS
Wellrounder
380V, THREE PHASE DIMENSIONS & WEIGHT DATA
)
m
m
1.5 45°
Height H1 Nett Weight Approx. (5
Lead Out Cable ”
Model HP 02
Size (Sq.mm) 2.
mm Inches kg lbs
W6A-60-4I 6.0 2.5 754 29.6 44.3 97.66
W6A-75-4I 7.5 4 804 31.6 49.7 109.52 M12 STUD 4 NOS
ON PCD 111
W6A-100-4I 10 4 854 33.6 54.7 120.69
W6A-125-4I 12.5 6 884 34.7 58 127.91 Ø5.62” (143mm)
W6A-150-4I 15 6 924 36.3 62.8 138.38 Ø3” (76.22mm)
W6A-175-4I 17.5 6 964 37.9 67 147.58 1.45” (37mm) Ø2.2” (57mm)
(Spline Length)
Ø0.98” (25mm)
W6A-200-4I 20 10 1004 39.5 71.2 157.04
W6A-250-4I 25 10 1084 42.6 79.6 175.47
(72.8mm)
(30mm)
2.86”
1.18”
W6A-300-4I 30 10 1154 45.4 85.5 188.43
W6A-400-4I 40 10 1229 48.3 93.7 206.76
W6A-500-4I 50 16 1304 51.2 97.9 215.75
W6A-600-4I 60 16 1379 54.2 99.7 220
The above mentioned electrical data are applicable for Star-Delta motors also
Note: Star-Delta motors are available from 7.5 H.P. onwards.
In view of continuous developments, the information / descriptions / specifications / illustrations are subject to change without notice.
27
COMMITMENT RELIABILITY INNOVATION
Wellrounder
W6A-50-4M 5 1.15 7.9 4680 8.5 5120 80.5 79 77.5 76 78.5 75.9 38 3500
W6A-60-4M 6 1.15 9 5900 10.5 6720 81 82 80 83 82 78 48 3500
W6A-75-4M 7.5 1.15 11 7000 12.5 8050 78 79 78.5 81 80 79.5 60 3500
W6A-100-4M 10 1.15 14 9260 16 10600 80 81 80 82 78 77 78 3500
W6A-125-4M 12.5 1.15 17.6 11680 19.8 13400 79.8 80 79.5 84 82 81.5 90 3500
W6A-150-4M 15 1.15 21 13200 23.5 15300 82.5 83 82 81.7 80 79 120 3500
W6A-200-4M 20 1.15 27 18200 31 20800 82 82.5 82 88 86 85.5 165 3500
W6A-250-4M 25 1.15 33 22320 37 25600 82.5 83 82.2 86.8 82.5 82 220 3500
W6A-300-4M 30 1.15 38.8 26750 44.5 30750 82.5 83.5 82 86.5 85 82 260 3500
W6A-350-4M 35 1.15 48 31200 55 35800 82 84 82 82 82 81.5 290 6000
W6A-400-4M 40 1.15 53.5 35760 61.5 41160 83.5 84 83.5 83.3 83.8 83 330 6000
W6A-500-4M 50 1.15 67 44160 77 51500 83 84.5 84 84 83 80 390 6000
W6A-600-4M 60 1.15 85 56400 96 65000 80.5 81 80.5 85 83 79 425 6000
The above mentioned electrical data are applicable for Star-Delta motors also
Note: Star-Delta motors are available from 7.5 H.P. onwards.
In view of continuous developments, the information / descriptions / specifications / illustrations are subject to change without notice.
28
Pumping trust. Worldwide. C.R.I. MOTORS
Wellrounder
Specifications
Nominal Dia 8” (200mm)
Maximum Outer Diameter 7.71"
Power Range 50 HP to 125 HP - Three Phase
Speed 3450 rpm
Version Three Phase - 380 V & 460 V, 60 Hz, A.C Supply
Class of Insulation Y
Degree of Protection IP 58 / IP 68
Direction of Rotation Electrically Reversible - Three Phase
Type of Duty S1 (Continuous)
50 HP to 60 HP - 10000 lbs
Down Thrust Load
75 HP to 125 HP - 12500 lbs
Minimum Cooling Flow Along the Motor 0.5 ft/sec
Maximum Liquid Temperature 91.4°F
Starts per Hour 10 Times
Shaft Type Splined as per NEMA Standard
Mounting Standard NEMA Standard
Three Phase - 50 HP to 125 HP - Direct On Line (DOL)
Method of Starting
Three Phase - 50 HP to 125 HP - Star Delta (SD)
Permanently Connected and Sealed 3/4 Core
Cable Lead out
PVC / Rubber Insulated Flat Cable
High Temperature Motors for 158°F / 194°F can be
Thermal Protection
supplied with PT Sensor and XLPE / PA Winding
* On request motors 440V & 690V can be supplied.
Materials of Construction
Part Name Type - B Type - S
In view of continuous developments, the information / descriptions / specifications / illustrations are subject to change without notice.
29
COMMITMENT RELIABILITY INNOVATION
Wellrounder
380V & 460V, THREE PHASE DIMENSIONS & WEIGHT DATA
Height H1 Nett Weight Approx.
Lead Out Cable 45°
Motor Model HP Size (Sq.mm)
mm Inches kg lbs 6 STUD 4 NOS
ON PCD 152.4
The above mentioned electrical data are applicable for Star-Delta motors also.
In view of continuous developments, the information / descriptions / specifications / illustrations are subject to change without notice.
30
Pumping trust. Worldwide. C.R.I. MOTORS
Wellrounder
Specifications
Nominal Dia 10” (250mm)
Maximum Outer Diameter 9.1"
Power Range 100 HP to 250 HP - Three Phase
Speed 3490 rpm
Version Three Phase - 380 V & 460 V, 60 Hz, A.C Supply
Class of Insulation Y
Degree of Protection IP 68
Direction of Rotation Electrically Reversible - Three Phase
Type of Duty S1 (Continuous)
Down Thrust Load 100 HP to 250 HP - 16860 lbs
Minimum Cooling Flow Along the Motor 0.5 ft/sec
Maximum Liquid Temperature 86°F
Starts per Hour 10 Times
Shaft Type Splined as per NEMA Standard
Mounting Standard NEMA Standard
Three Phase - Direct On Line (DOL)
Method of Starting
Three Phase - Star Delta (SD)
Permanently Connected and Sealed 3/4 Core
Cable Lead out
Rubber Insulated Flat Cable
High Temperature Motors for 158°F / 194°F can be
Thermal Protection
supplied with PT Sensor and PE2 / PA Winding Type - A/N Type - B
Materials of Construction
Part Name Type - A Type - N Type - B
In view of continuous developments, the information / descriptions / specifications / illustrations are subject to change without notice.
31
COMMITMENT RELIABILITY INNOVATION
Wellrounder
380V & 460V - THREE PHASE DIMENSIONS & WEIGHT DATA
Height H1 Nett Weight
Motor Power Lead Out Cable Size (Sq.mm) Approx.
Motor Models
kW HP DOL SD mm Inches kg lbs
W10A-A00-4 75 100 25 16 1226 18.9 239.4 528
W10A-A10-4 81 110 25 16 1266 19.6 259.4 572
W10A-A25-4 93 125 25 16 1316 20.3 273.5 603 Ø9.1” (231mm)
(42.9mm) (min)
1.68”
165 225 35 35 1856 28.7 408.2 900
(101.6mm)
W10A-B25-4
4”
W10A-B50-4 185 250 35 35 1956 30.2 439.0 968
380V DOL & SD MOTORS - THREE PHASE TECHNICAL & ELECTRICAL DATA
Motor
Power Max. Cable Size (Sq.mm)
Method Full Load Starting Efficiency Down
Model of Current Current Power Thrust
(A) (%) Factor Load DOL SD
Starting (A)
kW HP (lbs) No. of No. of
Leadouts Leadouts
Ø9.1” (231mm)
W10A-A00-4I 75 100 T/D 150 225 86 0.87 16860 1 2
D
W10A-A10-4I 81 110 T/D 166 249 86 0.87 16860 1 2
W10A-A25-4I 93 125 T/D 181 272 87 0.89 16860 1 2
W10A-A50-4I 110 150 T/D 220 330 87 0.89 16860 2 2
W10A-A75-4I 130 175 T/D 255 383 87 0.89 16860 2 2
W10A-B00-4I 150 200 T/D 290 435 88 0.89 16860 2 2
W10A-B25-4I 165 225 T/D 325 488 88 0.89 16860 2 2
W10A-B50-4I 185 250 T/D 355 533 89 0.90 16860 2 2
460V DOL & SD MOTORS - THREE PHASE TECHNICAL & ELECTRICAL DATA
Motor Cable Size (Sq.mm)
Power Max.
Motor Method Full Load Starting
of Current Current Efficiency Power Down
Model Starting (A) (A) (%) Factor Thrust DOL SD
kW HP Load No. of No. of
(lbs) Leadouts Leadouts
W10A-A00-4M 75 100 T/D 130 194 86 0.87 16860 1 2
W10A-A10-4M 81 110 T/D 143 215 86 0.87 16860 1 2
W10A-A25-4M 93 125 T/D 156 234 87 0.89 16860 1 2
W10A-A50-4M 110 150 T/D 190 285 87 0.89 16860 2 2
W10A-A75-4M 130 175 T/D 220 330 87 0.89 16860 2 2 ALL DIMENSIONS ARE
IN Inches & mm.
W10A-B00-4M 150 200 T/D 250 376 88 0.89 16860 2 2
W10A-B25-4M 165 225 T/D 281 421 88 0.89 16860 2 2
# METHOD OF STARTING : T - 3P / DOL / 60Hz D - 3P / SD / 60Hz
In view of continuous developments, the information / descriptions / specifications / illustrations are subject to change without notice.
32
Pumping trust. Worldwide. C.R.I. MOTORS
Wellrounder
Specifications
Nominal Dia 12” (300mm)
Maximum Outer Diameter 10.7"
Power Range 250 HP to 600 HP - Three Phase
Speed 3460 rpm
Version Three Phase - 380 V & 460 V, 60 Hz, A.C Supply
Class of Insulation Y
Degree of Protection IP 68
Direction of Rotation Electrically Reversible - Three Phase
Type of Duty S1 (Continuous)
Down Thrust Load 250 HP to 600 HP - 13500 lbs
Minimum Cooling Flow Along the Motor 1.64 ft/sec (86°F), 2 ft/sec (122°F)
Maximum Liquid Temperature 86°F
Starts per Hour 10 Times
Shaft Type Key Way
Mounting Standard International Standard
Three Phase - Direct On Line (DOL)
Method of Starting
Three Phase - Star Delta (SD)
Permanently Connected and Sealed 3/4 Core Rubber
Cable Lead out
Insulated Flat Cable
High Temperature Motors for 158°F / 194°F can be
Thermal Protection
supplied with PT Sensor and XLPE / PA Winding Type - A/N Type - B
* On request motors 440V & 690V can be supplied.
Materials of Construction
Part Name Type - A Type - N Type - B
* Optional.
In view of continuous developments, the information / descriptions / specifications / illustrations are subject to change without notice.
33
COMMITMENT RELIABILITY INNOVATION
Wellrounder
380V & 460V - THREE PHASE DIMENSIONS & WEIGHT DATA
Lead Out Cable Nett Weight
Motor Power Size (Sq.mm) Height H1
Model Approx.
kW HP 380V 460V mm Inches kg lbs
Ø5” (127mm)
Ø2.16” (55mm)
380 V - THREE PHASE TECHNICAL & ELECTRICAL DATA Ø5.01”
Ø4.25” (127.3mm)
Motor Full Starting Full load Max. Down (108mm)
Power Method No. of 0.19” (5mm)
Model Load Current Power Thrust 1.18”
of Starting Eff.% Leadouts
kW HP Max (A) (A) Factor Load (lbs) (30mm)
In view of continuous developments, the information / descriptions / specifications / illustrations are subject to change without notice.
34
Pumping trust. Worldwide. C.R.I. MOTORS
THREE PHASE 3 WIRE (D.O.L.) MOTOR MAXIMUM LENGTH OF COPPER CABLE - SINGLE CABLE PER PHASE
Motor
Rating CABLE SIZE IN AMERICAN WIRE GAUGE
VOLT HP 14 12 10 8 6 4 3 2 1 1/0 2/0 3/0 4/0
0.5 842 1341 2130 3391 5373
0.8 607 967 1535 2445 3874 6179
1.0 475 756 1200 1911 3029 4831 6085
1.5 358 569 904 1440 2282 3640 4585 5782
2.0 272 433 688 1095 1735 2768 3486 4397 5542
Calculate Cable Length (FEET)
3.0 218 346 550 876 1388 2214 2789 3518 4434 5587 7049
4.0 155 247 393 626 992 1582 1992 2513 3167 3991 5035
5.0 112 178 282 449 712 1135 1430 1804 2274 2865 3615 4559 5748
6.0 95 151 239 381 604 963 1213 1529 1928 2429 3065 3865 4873
7.5 126 200 319 505 805 1014 1279 1612 2032 2563 3233 4076
220V
10.0 99 157 250 397 633 797 1005 1267 1596 2014 2540 3202
12.5 134 214 339 540 680 858 1081 1363 1719 2168 2734
15.0 112 179 283 452 569 718 905 1140 1439 1814 2287
17.5 97 154 244 388 489 617 778 980 1237 1560 1966
20.0 136 216 344 433 546 688 868 1095 1380 1740
25.0 112 178 283 357 450 567 714 901 1137 1433
30.0 151 241 303 382 482 607 766 966 1218
35.0 108 172 217 274 345 435 549 692 873
40.0 147 185 233 293 370 466 588 742
50.0 130 164 206 260 328 414 522 658
3.0 457 727 1155 1840 2915 4650 5857 7387 9311 11732 14803
4.0 326 520 825 1314 2082 3321 4184 5276 6651 8380 10574
5.0 234 373 592 943 1495 2384 3004 3788 4775 6017 7591 9573 12071
6.0 199 316 502 800 1267 2022 2547 3212 4048 5101 6436 8116 10234
7.5 264 420 669 1060 1691 2130 2686 3386 4266 5383 6788 8559
220V
10.0 208 330 526 833 1329 1673 2111 2660 3352 4229 5334 6725
12.5 282 449 711 1134 1429 1802 2271 2862 3610 4553 5741
15.0 236 375 595 949 1195 1508 1900 2394 3021 3810 4804
17.5 203 323 511 816 1028 1296 1633 2058 2597 3275 4129
20.0 286 453 722 909 1147 1446 1822 2299 2899 3655
25.0 235 373 595 749 945 1191 1500 1893 2387 3010
30.0 317 505 637 803 1012 1275 1609 2029 2558
35.0 227 362 456 575 725 914 1153 1454 1833
40.0 308 388 489 616 776 979 1235 1557
50.0 273 344 433 546 688 868 1095 1381
35
COMMITMENT RELIABILITY INNOVATION
36
Pumping trust. Worldwide. C.R.I. MOTORS
3Ph, 460V, 3 WIRE (DOL) MOTORS, MAXIMUM LENGTH OF COPPER CABLE IN FEET
Motor
Rating CABLE SIZE IN AMERICAN WIRE GAGE MCM Copper wire size
VOLT HP 14 12 10 8 6 4 3 2 1 1/0 2/0 3/0 4/0 250 300 350 400 500
0.5 880 1420 2250 3450 5550 8620
0.75 743 1182 1878 2990 4739 7559
1 681 1083 1720 2739 4340 6923
1.5 630 1020 1600 2530 3960 6150 7650 9390
2 460 750 1180 1870 2940 4570 5700 7020 8620
3 368 585 930 1480 2345 3741 4713 5943 7491
4 310 510 810 1270 2010 3130 3900 4800 5800 7210 8850
5 230 380 610 970 1540 2410 3000 3700 4560 5590 6870 8290
5.5 190 310 490 790 1240 1950 2430 2980 3670 4510 5550 6700
6 250 410 640 1020 1600 1990 2460 3040 3730 4590 5550
7.5 335 533 844 1347 1697 2140 2697 3398 4288 5002
10 300 480 750 1180 1470 1810 2230 2740 3370 4080
12.5 370 590 960 1200 1470 1810 2220 2710 3280
Calculate Cable Length (FEET)
CONVERSION TABLE
FLOW RATE
US-GPM lps lpm m3/h ft3/h ft3/min imp - GPM US - barrel / day
1 0.063 3.785 0.2271 8.0209 0.1337 0.833 34.286
15.850 1 60 3.6 127.133 2.1189 13.2 543.439
0.264 0.017 1 0.06 2.1189 0.0353 0.22 9.057
4.403 0.278 16.667 1 35.3147 0.5886 3.666 150.955
0.125 0.008 0.472 0.0283 1 0.0167 0.104 4.275
7.48 0.472 28.317 1.6990 60 1 6.229 256.475
1.201 0.076 4.546 0.2728 9.6326 0.1605 1 41.175
0.029 0.002 0.110 0.0066 0.2339 0.0039 0.024 1
LIQUID
US-Gallon m3 Litre (L) Milliliter (ml) lmp. Gallon ft3
1 0.00378 3.785 3785 0.8327 0.1337
264.2 1 1000 1X106 220 35.3147
0.2642 0.001 1 1000 0.22 0.0353
2.642X10-4 1X10-6 0.001 1 2.2X10-4 3.53X10-5
1.201 0.00455 4.546 4546 1 0.1605
7.4805 0.0283 28.317 28317 6.2288 1
LENGTH
Inch (in) Millimeter (mm) Centimeter (cm) Meter (m) Foot (ft) Yard (yd)
1 25.4 2.54 0.0254 0.0833 0.0278
0.0394 1 0.10 0.001 0.0033 0.0011
0.3937 10 1 0.01 0.0328 0.0109
39.3701 1000 100 1 3.2808 1.0936
12 304.8 30.48 0.3048 1 0.3333
36 914.4 91.44 0.9144 3 1
MASS 1 kilometer = 1000 metre = 0.62137 mile; 1 mile = 1609.34 metre = 1.60934 kilometre
Pound (lb) Kilogram (kg) Hundred Weight (cwt) Tonne (t) Ton long (tn) short Ton (sh tn)
1 0.454 0.0089 4.54x10-4 4.46x10-4 5.0x10-4
2.205 1 0.0197 0.001 9.84x10-4 0.0011
112 50.802 1 0.0508 0.05 0.056
2204.6 1000 19.684 1 0.9842 1.1023
2240 1016 20 1.0161 1 1.1020
2000 907.2 17.857 0.9072 0.8929 1
TEMPERATURE
To Convert From To Use Formula
Celsius, tC Kelvin, tK tK = tC + 273.15
Fahrenheit, tF Kelvin, tK tK = (tF + 459.67) / 1.8
Celsius, tC Fahrenheit, tF tF = 1.8 tC + 32
Fahrenheit, tF Celsius, tC tC = (tF - 32) / 1.8
Kelvin, tK Celsius, tC tC = tK - 273.15
Kelvin, tK Fahrenheit, tF tF = 1.8 tK - 459.67
38
NOTES
..................................................................
..................................................................
..................................................................
..................................................................
..................................................................
..................................................................
..................................................................
..................................................................
..................................................................
..................................................................
..................................................................
..................................................................
..................................................................
NOTES
..................................................................
..................................................................
..................................................................
..................................................................
..................................................................
..................................................................
..................................................................
..................................................................
..................................................................
..................................................................
..................................................................
..................................................................
..................................................................