EMP-168
Biochemical Analyzer
Service Manual
1
EMP-168 SERVICE MANUAL
Edition:
5th Jun.2007, the first edition
Copyright 2007 Shenzhen Emperor Electronic Technology Co.,Ltd.
Declaration:
Copyright © ShenzhenEmperorElectronicTechnologyCo.,Ltd., 2007, reserves all proprietorship of a copyright.
EMPEROR also reserves the right of modifying products specifications and all the
information in this service manual. No prior notice will be given in case the information in
this manual has been modified.
No formal guarantees will be given by EMPEROR, including but-not-limited-in any
implied guarantees of applicability in sale and using for special purpose.
EMPEROR will not be responsible for the errors in this manual, and also not responsible
for compensating the accidents and implicative injuries which were caused by offering,
operating or using this manual.
Any part of this manual should not be copied, remade or transferred by any method or determination
before getting EMPEROR’s written permission.
Warning:
Only the engineers who are trained or authorized by our company can disassemble
and maintain this device.
2
EMP-168 SERVICE MANUAL
Preface
Dear customers:
Thanks for your purchase of EMPEROR biochemical analyzer. We are honored that you
trust in EMPEROR products. We provide this Service Manual with the purpose of
bringing you a total knowledge of this unit. This manual covers the principles of this unit,
also includes the features, maintenance, and troubleshooting of EMP-168. Meanwhile, in
order to make customers easily remove the troubles that they may always meet in
operation, this manual simply describes the method of disassembly as a guide for
maintenance. Please read the User Manual before you repairing it. We are sure that the
User Manual will help you a lot in operating this unit effectively, meanwhile please read
this Service Manual carefully. If you need more information, which this manual doesn’t
cover, please feel free to contact the local agents or distributors, also can contact with our
headquarters.
We think the information and data in the manual is corrective and reliable, and we try to
avoid any errors. However, it is hard to avoid some printing mistakes and some mistakes,
which are caused by some factors we can’t control. Thanks for your understanding! In
order to improve the performance and reliability of the parts and the unit, we probably
modify the hardware and software without notice. So hope you can understand in case
the service manual may be not comply with the unit somewhere.
You are appreciated for informing us if you find problems and errors in this manual.
Please find our contacting telephone and address in the last page.
3
EMP-168 SERVICE MANUAL
1. Check the accessories carefully according to Packing List. Please do not hesitate to
contact our distributor or our headquarters if any question.
2. Please read all information and the User Manual attached carefully and keep them
well.
3. You will get better technical support and service if you can contact our headquarters
before you maintain this unit.
4
EMP-168 SERVICE MANUAL
CONTENT
CHAPTER1 APPEARANCE ..........................................................................................................................6
CONTACT US ............................................................................................................................................. 22
5
EMP-168 SERVICE MANUAL
Chapter1 Appearance
6
2
7
3
8
4 9
5
10
11
1. Cover of printer 2. Face shell 3. Removable cover 4.Pipette 5. Aspirate switch 6.Display
6
EMP-168 SERVICE MANUAL
screen 7. Logo 8.Horn fenestra 9. Bottom shell 10. Keyboard 11. Power
indicator
Figure 1.1
WASTE
AC INPUT VOLTAGE:AC 100V 240V 50Hz
POWER ON/OFF POWER: 100VA
Biochemical Analyzer
F2A250V
RS232
1 2 3 4 5 6 7 8 9 10
7
EMP-168 SERVICE MANUAL
Chapter2 Disassembly
Before disassemble the unit, please make sure that:
1) There should be an engineer or technician approved by Com. EMPEROR;
2) The power supply has been cut off;
3) Probes and any other external components must be taken off.
Six screws
on bottom Figure2.1
1. Take six screws off above,then put the instrument on the table.
2. Take the cover away and draw the aspirate tube out from tube-holder as figure 2.2.
3. Open the shell softly and you can see some connections between the shell and the bottom as
4. Draw the FPC connector and FPC wire out as figure 2.4, take off all the connections between the
Aspirate tube
Figure 2.2
8
EMP-168 SERVICE MANUAL
Figure 2.3
Figure 2.3
Figure 2.4
9
EMP-168 SERVICE MANUAL
Back-end
pump
Photo part
Power
supply
Front-end
Figure2.5
The reversed shell is as figure2.6
Printer board
Keyboard
Aspirate switch
Figure2.6
The keyboard connector is as figure2.7
X28
To paper feed
X31
Signal wires of
keyboard
X25
X32
To power
To aspirate
indication
switch
Figure2.7
10
EMP-168 SERVICE MANUAL
X34
Printer
X33
communication
Paper feed connector
connector
X
X4
Printer power
4 screws
suppply(6V)
6V
Flexible wires
Flexible
connector
Figure2.8
3 screws
Figure2.9
Take off 3 screws, loose two flexible connectors and extract the flexible wires, the printer header
11
EMP-168 SERVICE MANUAL
LED of back-end
board
Clock cell
X29
Printer communication
LCD
To X34
transition board
fixed screws
X32
Back-end to front-end X5
Back-end
No use for custormaer
power supply
X30 5V
Audio input
X9
LCD Power
X30
input
Audio input
12V
3fixed
screws
1 Copper pillar
Figure2.11
12
EMP-168 SERVICE MANUAL
X27
Lamp power output
To back-end
AC power
4 screws
supply connector
Figure2.13
13
EMP-168 SERVICE MANUAL
Press down
with tweezers
Figure 2.15
4 screws
14
EMP-168 SERVICE MANUAL
2 screws to
fix FPC
wires
LCD
power
Figure2.16
4 screws
FPC connector
4 hexangular screws
Figure 2.18
Figure 2.17
Photo part
15
EMP-168 SERVICE MANUAL
Lamp part
1 Screw
Power supply
Figure 3.1
Figure 3.2
4 screws
Power suppluy
12V
Figure 3.3
2 screws
Peltier
Figure 3.4
16
EMP-168 SERVICE MANUAL
2 screws 4 screws
螺钉 M3×8PWM
Figure 3.5 Figure 3.6
Filter wheel
1 screw
17
EMP-168 SERVICE MANUAL
Cover
Screw
Handle
Clips
Press down
Figure 3.10
18
EMP-168 SERVICE MANUAL
Groove
Two fuses
Figure 3.8
19
EMP-168 SERVICE MANUAL
Chapter4 Trouble-shooting
SN Breakdown Description Solution
1 Can not start 1. Check AC power supply;
2. Check fuse(Figure3.8);
3. Check if the power indicator is on,if yes then check
next (Figure1.1);
4. Check the power supply of back-end with the power
line taking off (5V Figure2.10), if no voltage, the
power supply maybe damaged, replace power
supply.
5. Check if the LED on the back-end board is flickering.
If not flickering, then the back-end maybe damaged,
replace back-end board . (Figure2.10)
6. If everything is OK, but no diplay, then check the LCD
power supply(9.6V /Figure2.10 /X24), if no voltage,
check the power supply(Figure2.10 / X9) of the
transition board,if OK, maybe the LCD transition
board(Figure2.10 ) damaged, replace it. If the LCD
power is OK(9.6V), maybe the LCD is broken,
replace it (2.6).
2 No display on the screen after 1. Check the power supply of the back-end (5V
power on but the power indicator Figure2.10)
is on 2. Check LCD power supply (9.6V/Figure2.10 /X24)
3. Check if the FPC connected well(Figure2.4/
Figure2.10)
3 The lamp of the instrument can 1. Check the power supply before replace the lamp (5V
not be lightened Figure2.12)
2. Check if the X27-X32(figure2.10&figure2.12)
connected well;
3. The lamp is damaged, replace it( Figure3.1).
4 Aspiration is not correct 1. Check the pump tube;
2. Calibrate the pump coefficient.( METHOD:Multi-click
the down-left corner on the [system setting] interface
then enter password “szemp” in the pop-window, then
you can see a [pump coe.] button, default value is
1.8, maximum value is 3.34. Increase the value to
increase the aspiration quantity, decrease the value
to decrease the aspiration quantity, So you can
calibarte the aspiration with pre-know quantity liquid
by changing this value.
5 The temperature is not correct 1. Check the power supply of the peltier.( 12V / X13/
figure 2.12)
2. Check if connector X20 is connected well
(Temperature monitor/ figure 2.12)
3. Check the cooling fan of peltier
20
EMP-168 SERVICE MANUAL
21
EMP-168 SERVICE MANUAL
17 External printer doesn’t work 1. Check the power supply of the printer(Figure 2.8);
2. Check if the printer is based on PCL language;
18 Real time clock not correct 1. Resetting the time;
2. The clock cell on the back-end is exhausted, replace
it. (Figure 2.10)
19 Screen flickering 1. Check if the FPC wire connected well(Figure 2.4);
2. Check if the FPC erathed well( 2 screws on the LCD
transition board(Figure 2.4).
20 Update failure 1. Check the SD card or the USB disk;
2. Check if the files for update is complete and correct.
21 Keyboard doesn’t work 1. Check the connection between the keyboard and
front-end(Figure2.3 / X26&X31);
2. Keyboard damaged, replace it.
22 Aspirate push-button doesn’t work 1. Check the switch of push-button(Figure 1.1);
2. Check the connection of the switch(Figure2.7 /X32).
23 Paper feed doesn’t work 1. Check the connection of the paper feed with printer
board.( Figure2.17 / X28)
24 Speaker doesn’t make sound 1. Check the connection of the speaker (Figure
2.10/X24);
2. Check the audio input connection(Figure 2.10/X30)
25 Power indicator (LED) doesn’t 1. Check the power supply(Figure 2.4);
light 2. Check the led connection with the keyboard(Figure
2.7 / X25).
26 Screen display nothing except 1. Check the FPC connector (Figure 2.7 / X25).
some littery colours
27 Filter motor and peristaltic pump 1. Check the power supply of X7(12V/ figure 2.12)
motor does not move 2. Check if the connector of the filter motor and
peristaltic pump motor X19/X18 connected
well.( Figure 2.12)
CONTACT US
Shenzhen Emperor Electronic Technology CO.,LTD
Address:2/F, Blg 7, Tian’an Nanyou Ind.Area,
Nanshan District,Shenzhen,China
Zip:518054
Phone: (0755)26073889 26073886
Sales:(0755) 26073889 26073379
26102407 26418226
Services:(0755)26073882 26102405
Fax: (0755)26419886
E-mail:[email protected]
Website: Http://www.china-emperor.com
22