5456SafetyCatalog.
qk 9/26/04 9:03 PM Page 18
Emergency Stop and Safety Gate Modules
NA1/2-D
• Safety Category 4 according to EN 954-1
• Redundant circuit
• Force guided relay contacts
• Dual channel input
• 2 NO safety outputs
• Failure diagnosis by LEDs
• Feedback circuit for external contactors monitoring
• Automatic or manual start
• Approval: TUV pending
Product Description Ordering Key NA1/2-D
Emergency stop and safety safety outputs. It can be used Case
gate module according to EN together with safety magnetic Application
60204-1, EN 292-1 /-2, EN 418 sensors SMS series, safety Controlled Devices
and EN 1088. The safety switches or emergency push Safety Outputs
module is in safety category 4 buttons. Safety Category
and is provided with 2 NO
Electrical Specifications
Power supply 24 Vac -15/+10% 50-60Hz / Safety output switching AC 230/240 Vac/8A/1380VA
24 Vdc -15/+10% voltage /current /capability DC 300 V/6A/1380 VA
Power consumption < 5 VA / 5 W Safety output
Input current/voltage 70 mA @ 24 Vdc, without load contact fuse protection 5 A fast or 4 A delayed
Safety outputs 2 NO Insulation voltage 2.5 KV for signal parts;
4.0 KV for safety output parts:
Auxiliary outputs --
Pollution degree 2
Overvoltage category III
Time Specifications Environmental Specifications
Delay on energisation ≤ 150 ms Operating temperature -20°C to + 65°C
Delay on de-energisation ≤ 25 ms Storage temperature -25°C to + 65°C
Channel simultaneity ∞
Mechanical Specifications
Protection degree terminals IP 20 Max cross section
Protection degree housing IP 40 of external conductors 2.5 mm2 flexible wire
2.5 mm2 rigid wire
Housing material Polyamid PA 6.6
Dimensions (H x W x D) 99x22.5x105 mm
Housing type 22.5 mm housing models
Weight 200 g
Mounting DIN rail
1-15 Specifications are subject to change without notice (10.01.04)
5456SafetyCatalog.qk 9/26/04 9:03 PM Page 19
NA1/2-D
Dimensions
Wiring Diagrams Application
Double gate monitoring
Connection Sample Connections
Terminal Function/Connection
A1 +24 Vdc or AC supply
A2 GND or AC supply
S11-S12 First input channel (NO)
S21-S22 Second input channel (NO)
X1-X2 Feedback and Reset
circuit input
13-14 First safety output (NO)
23-24 Second safety output (NO)
Front NA1/2-D
Specifications are subject to change without notice (10.01.04) 1-16