The Retiwave-1000 is a digital ultrasonic system used for ophthalmology. It can perform A and B scans to measure the eyeball and diagnose conditions like cataracts, retinal issues, and tumors. A scans provide measurements of the anterior chamber, lens thickness, axial length, and more to calculate IOLs. B scans produce clear profile images of the eyeball to examine its anatomical structures and any nodules.

Uploaded by

Nurul Amin
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
570 views10 pages

AB Scan

The Retiwave-1000 is a digital ultrasonic system used for ophthalmology. It can perform A and B scans to measure the eyeball and diagnose conditions like cataracts, retinal issues, and tumors. A scans provide measurements of the anterior chamber, lens thickness, axial length, and more to calculate IOLs. B scans produce clear profile images of the eyeball to examine its anatomical structures and any nodules.

Uploaded by

Nurul Amin
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 10

Ophthalmic A/B Scan

Retiwave-1000 A/B Scan

Feature:

Retiwave-1000 is digital ultrasonic system for ophthalmology. With advanced intelligent digital software the parameters
of freezed and stored images could be adjusted voluntarily.Scan A measures data for every part of the eyeball as anterior
chamber depth, lens thickness,axial length and so on which are needed in ophthalmic surgeries, and calculates IOL by
axial length. Scan B displays profile images of the eyeball clearly and directly. Scanning anatomical formsand nidi inside
the eyeball, doctors can diagnose accurately for examination of cataract, vitreousbody disease, ocular trauma,
detachment of retina or choroid, macula disease, and intraoculartumor, etc..

CHONGQING VISION STAR OPTICAL CO., LTD www.hyvisionstar.com


Ophthalmic A/B Scan
ODU-5 A/B Scan

Feature:

 10.4’’ adjustable LED screen


 Press one key could transport current image to PC workstation
 Equipped with keyboard floodlight, used for dark room
 100 images permanent storage capacity.
 Standard workstation software, easily management and print data

Technical Data
A Probe frequency 10MHz
A Probe Measuring model Contact
A Probe Measuring range Over 5mm~40mm
A Probe Measuring error ≤0.05mm
A Probe Measuring type Length of optic axis, automatic calculation, result analysis
A Probe Image freezing Image freezing auto, auto+ preservable, manual
Intraocular lens formula SRK-T, SRK II, HOLLADAY,BINKHORST-IIHOFFER-Q, HAIGISI
Gain 20~110dB Technical Data
Time gain adjustment 0~30dB A Scan B Scan
B Probe Frequency 10Mhz ACD, Lens, Vitreous, Axial length measurement High resolution and contrast B scan
B Probing Depth ≥50mm IOL Formulas: SRK-II, SRK-T, BINKHORST, 8 kinds pseudo-color
Axial Resolution ≤ 0.2mm HOLLADAY,HOFFER-Q,HAIGIS
Lateral Resolution ≤0.3mm Direct contact/immersion measurement Multiple electronic measurements: Distance, Area,
Gain Adjustment 20-110db Perimeter, Volume
Time Gain Adjustment 0-30db Support Normal, Cataract, Aphakic and Special eye 8 kinds TGC adjustable
Operation Mode Eyecup, gel, aqueous capsule model
Post Processing Measuring Tools Area, Length, Mark and Annotation
Reviews 100 images available

CHONGQING VISION STAR OPTICAL CO., LTD www.hyvisionstar.com


Ophthalmic A/B Scan
Technical Data

SW-2100 A/B Scan A Scan B Scan


Frequency 10MHz, with LED Frequency 10MHz/20MHz(optional), magnetic
driven, noiseless
Depth 40mm Scanning Mode Sector Scanning
Feature:
Precision ±0.05 mm Magnify Multi continuous magnification,
real-time magnification
With normal, vitreous body enhancement, retina observation model, SW-2100 is mainly used for diagnosis of introcular Measurement Anterior chamber depth, Resolution Lateral ≤0.3mm; Vertical ≤0.2mm
diseases, display the location, shaper range of the focus of infection and relationship with the surrounding tissue. Can be lens thickness, Geometry position Lateral ≤10%; Vertical ≤5%
diagnosed vitreous opacity, retinal detachment, eye base tumors, etc. eye diseases. A scan is used to measure chamber vitreous body length, total precision
depth, lens thickness, axial length, calculate diopter of implant IOL as well. length and average Depth 60mm
Gain of probe 30dB-105dB
Eye mode Phakic / Aphakic / Dense / Scanning Angle 53°
Various IOL
IOL Formula SRK-II, SRK-T, HOFFER-Q, Gray Scale 256
HOLLADAY,BINKHORST-II, False Color Multi colors. OCT
HAIGIS measurement type Multigroup distances, perimeters
and areas
Stat. Calculation Average and standard Movies 100 images movie review, AVI JPG
deviation format image output
Store 10 Scanning results for Image postprocessing multiple curves processing,
each eye Pseudo-color processing curve
Display Mode B, B+B, B+A, A
Hint Preset keyword
Case Search Multi-keywords
User-defined report with
template

CHONGQING VISION STAR OPTICAL CO., LTD www.hyvisionstar.com


Ophthalmic A/B Scan
SAB-500 A/B Scan

Feature:

SAB-500 A/B Scan with normal, vitreous body enhancement, retina observation mode, mainly used for diagnosis of
intraocular diseases, display the location, shape range of the focus of infection and the relationship with the surrounding
tissue. Can be diagnosed vitreous opacity, retinal detachment, eye base tumors etc. eye diseases. A scan is used to
measure anterior chamber depth, lens thickness, axial length, calculate diopter of implant IOL as well.

Technical Data
A Scan B Scan
Frequency: 10MHz, with LED Frequency 10MHz/20MHz(optional) , magnetic
driven, noiseless
Depth 40mm Scanning Mode Sector Scanning
Precision ±0.05 mm Magnify Multicontinuous magnification,
real-time magnification
Measurement Anterior chamber depth, lens Resolution Lateral ≤0.3mm; Vertical ≤0.2mm
thickness, vitreous body length,
total length and average
Eye mode Phakic / Aphakic / Dense / Geometry position precision Lateral ≤10%; Vertical ≤5%
Various IOL
IOL Formula SRK-II, SRK-T, HOFFER-Q, Depth 60mm
HOLLADAY, BINKHORST-II,
HAIGIS
Stat. Average and standard deviation Enhance the part of vitreous body and retina
Calculation
Store 10 Scanning results for each Gain of probe 30dB-105dB
eye
Display Mode B, B+B, B+A, A Scanning Angle 53°
Hint preset keyword Gray Scale 256
Case Search Multi-keywords False Color Multi colors. OCT
Screen 15 inch LCD Measurement type Multigroup distances, perimeters and
areas
Built-in battery can use 4 hours Image post processing Multiple curves processing,
pseudo-color processing curve
User-defined report template poor credit secured Movies 100 images movie review, AVI JPG
loans format image output

CHONGQING VISION STAR OPTICAL CO., LTD www.hyvisionstar.com


Ophthalmic A/B Scan
SAB-200 A/B Scan Technical Data
A Scan B Scan
Frequency: 10MHz, with LED Frequency 10MHz/20MHz (optional), magnetic
Feature:
driven, noiseless
Depth 40mm Scanning Mode Sector Scanning
Precision ±0.05 mm Magnify Multicontinuous magnification, Real-Time
SAB-200 A/B Scan with normal, vitreous body enhancement, retina observation mode, mainly used for diagnosis of
magnification
intraocular diseases, display the location, shape range of the focus of infection and the relationship with the surrounding
Measurement Anterior chamber depth, lens Resolution Lateral ≤0.3mm; Vertical≤0.2mm
tissue. Can be diagnosed vitreous opacity, retinal detachment, eye base tumors etc. eye diseases. A scan is used to
thickness, vitreous body
measure anterior chamber depth, lens thickness, axial length, calculate diopter of implant IOL as well
length, total length and
average
Eye mode Phakic / Aphakic / Dense / Geometry position Lateral ≤10%; Vertical≤5%
Various IOL precision
IOL Formula SRK-II, SRK-T, HOFFER-Q, Depth 60mm
HOLLADAY, BINKHORST-II,
HAIGIS
Stat. Calculation Average and standard Enhance the part of vitreous body and retina
deviation
Store 10 Scanning results for each Gain of probe 30dB-105dB
eye
Display Mode B, B+B, B+A, A Scanning Angle 53°
Hint preset keyword Gray Scale 256
Case Search Multi-keywords False Color Multi colors. OCT
Screen 15 inch LCD Measurement type multigroup distances, perimeters and
areas
Built-in battery can use 4 hours Image post processing multiple curves processing, Pseudo-color
processing curve
User-defined report template poor credit secured Movies 100 images movie review, AVI JPG format
loans image output

CHONGQING VISION STAR OPTICAL CO., LTD www.hyvisionstar.com


Ophthalmic A/B Scan
SK-3000 A/B/P Scan SP-2000 A/B Scan

Feature: Feature:

 A scan, B scan and pachymeter in one  Compact body, light weight


 Data sharing in Lan (optional)  One station working platform
 Many measurement tools  USB connection
 150 frames video record  Integrated image capture
 Integrated patient management
 Integrated report edit

Technical Data
B Scanner
Probe Frequency 10MHz
Scanning Mode Mechanical sector scanning
Gray Scale 256 Levels
Zoom √
Total Gain 20- 105db
Measuring Depth ≥60mm
Scanning Angle 53°
TGC TGC 0-30db
Memory 20 Images Technical Data

Resolution Axial ≤ 0.2mm, lateral ≤ 0.4mm A-Scan


Display Mode B, B+A
Scan Modes Contact/Immersion
Pseudocolor Mode √
Examination Modes Normal, Dense Cataract, Aphakic, Pseudophakic (PMMA, Acrylic, Silicone)
Report Print Vedio
Playback 150 Frames AXL, ACD, Lens and Vitreous, Individual Segment Velocities, Average and Standard Deviations
Measurements
A Scanner for AXL, ACD, Lens&Vitreous

Probe Frequency 10MHz Specification Clinical Accuracy: ±0.1mm, Electrical Accuracy: 0.0375mm, IOL Calculation in 0.5D Increments
Measuring Range 0-42mm
IOL Calculation Refractive: SRK-II, SRK-T, Binkhorst- II, Holladay, Hoffer-Q, Haigis, Post-refractive: Latkany
Biometry Accuracy 0.05mm
Formulas Myopic, Latkany Hyperopic, Double-K/SRK-T
EYE Mode 6 Different measuring mode, 3 Custom measuring mode
A-Scan Probe Hand-held, Immersion or Slit Lamp Mounted Applicable
LOL Formula 6 Calculation formulas with contrast calculation
B-Scan
Statistical Calculation Standard deviation, variance
Scan Modes B Mode, B+A Mode, B+B Mode
P Scanner
Probe Frequency 20MHz 1. Adjustable Zoom, Gain. 2. Variable Gain Control. 3. 256 Levels Grey Scale,
Features
Biometry Accuracy ≤ 0.01mm 4. Capture of Frames and Cline Loops Available. 5. Clinical Resolution: 0.2mm
Measuring Depth 0.3-1.2mm Probe Transducer Frequency: 12.5MHz, 53° Sector Scanning Method
Output Mode Vedio 20MHz FD 13mm for Anterior segment
Computer Parameter Special imbedded system, 12.1" display screen, touching type operation Optional 20MHz FD 25mm for Posterior segment
Printer Available Sony copy machine, normal Accuracy: 0.1mm

CHONGQING VISION STAR OPTICAL CO., LTD www.hyvisionstar.com


Ophthalmic A/B Scan
ODU-8 A/B Scan CAS-2000B A/B Scan

Feature:
Feature:
 10.4’’ adjustable LED screen
 Capable of capturing both still images and video clips, provides excellent image resolution with a full set of
 Press one key could transport current image to PC workstation
features
 Equipped with keyboard floodlight, used for dark room
 Easy to use measurement calipers for distance and angle measurements
 100 images permanent storage capacity.
 Frame-by-frame review of video clips provided for selection
 Standard workstation software, easily management and print data
of optimal image
 Patient database and image library is provided with printing and download capabilities

Technical Data
A Scan B Scan
Probe Frequency 10MHZ B-scan mode Mechanic Sector scans
Method contact, immersion (optional) Scan angle 53°
Precision 0.05mm Detect Depth 50mm
Measurement ACD depth, lens, axial length, Probe frequency 10 MHZ Error±0.5 MHZ
parameters and its average
IOL Calculation SRK/II, SRK/T, Holladay, Resolution Vertical<0.5mm, Lateral<1.0mm
SCDK, Hoffer-Q, Haggis
Operation Automatic, Manual Gray Scale 256
Technical Data
Information storage Build-in Case data Display Mode B; B+B; B+A
A Scan B Scan
Printer Inner Thermal Printer Images reports External high definition ink-jet printer
ACD, Lens, Vitreous, Axial length measurement High resolution and contrast B scan
Display Monitor High Speed LCD Image Post Brightness, Contrast, Smooth, Sharp,
IOL Formulas: SRK-II, SRK-T, BINKHORST, 8 kinds pseudo-color
Processing stretch, Equalize, etc.
HOLLADAY,HOFFER-Q,HAIGIS
Report Data Patient’s name, ID, Right/left, Ultrasonic videoing Ultrasonic image dynamic playback
Direct contact/immersion measurement Multiple electronic measurements: Distance, Area,
Doctor's name, Date, IOL grey scale reaches
Perimeter, Volume
table. 256
Support Normal, Cataract, Aphakic and Special eye 8 kinds TGC adjustable
model

CHONGQING VISION STAR OPTICAL CO., LTD www.hyvisionstar.com


Ophthalmic A/B Scan
ODM-2100 A/B Scan ODM-2100S A/B Scan

Feature:

 Operating mode: B, B+A, B+B, A


 High resolution images
 8 images memory
 6 steps zoom from 34-60mm
 Variable displaying area, various area measurements
 5 sections adjustable TGC
 Cineloop for 5.6sec
 Accurate axial measurement under B-mode (SMI-5)
 Manual correction of axial measurement under A-mode (SMI-5)
 Multi-groups of calipers for distance measurement
 Measuring mode: contact and immersio
 8 groups average with standard deviation (S.D.)
 Save up to 50 groups of IOL calculation results Technical Data
 B-probe protection: automatic stop after 10 minutes of continuous scanning B-Scan
 Foldable keyboard, fully portable Display mode B, B+B, B+A, A

Technical Data Probe frequency 10MHz

B-Scan: A-Scan: Scanning method Mechanical sector scan

Probe frequency 10MHz Probe 10MHz with fixation red light Scanning angle 53°

Scanning angle 53° Resolution 0.01mm Resolution Axial≤0.2mm, lateral≤0.4mm

Resolution Axial ≤ 0.2mm, lateral≤ 0.4mm Biometry accuracy ≤±0.06mm Gain 0~98 dB adjustable

≥98dB with an adjustable range Zoom 34mm~60mm, 6 steps selectable


Total gain ≥98dB adjustable Gain
of 0~55dB Post processing 4 groups of curves (Linear, Logarithmic, Exponential, S-curve)

Zoom 34mm~60mm, 6 steps selectable Measuring range 15~39mm Gray scale 256 levels

anterior chamber depth, lens Distance & area measurement


-30d~0dB dynamic, 6 points
TGC Measuring parameters thickness, vitreous length and A-Scan
manually adjustable
axial length Probe 10MHz with fixation red light
automatic (for normal, dense Resolution 0.01mm
Variable delay 5 different measuring
0~15mm cataract, aphakic and Biometry accuracy ≤±0.06mm
depth modes
pseudophakic); manual Gain ≥98dB with an adjustable range of 0~55dB
SRK/T, SRK-II, BINKHOST-II, 15~39mm
4 groups of curves (linear, Measuring range
Post processing IOL formula HOLLADAY, HOFFER-Q and
logarithmic, exponential, s-curve) Measuring parameters Anterior chamber depth, Lens thickness, vitreous length and axial length
HAIGIS
Measuring method Contact
Gray scale 256 levels Calculation of 8 groups average with standard deviation (S.D)
5 different measuring Modes Automatic (for normal, dense cataract, Aphakicand special); manual
Dynamic replay for 5.6 sec, 56 images displayed
Save up to 50 groups of results and 4 groups of IOL constants IOL Formula SRK/T, SRK-II, BINKHOST-II, HOLLANAY, HOFFER-Q and HAIGIS
continually or separately
Multi-groups of electronic calipers for distance measurement Calculation of 8 groups’ average with standard deviation (S.D)

Various area measurement Save up to 50 groups of results and 4 groups of IOL constants

CHONGQING VISION STAR OPTICAL CO., LTD www.hyvisionstar.com


Ophthalmic A/B Scan
ODM-2300S A/B Scan
ODM-2200 A/B Scan
Feature: Feature:

 8 color codes  High Definition 20MHz B-scan Image.


 Operating mode: B, B+A, B+B, A  High Resolution LCD touch screen.
 High resolution images  Image/video snapped and stored in real time in multiple
 8 images memory buffer slots for immediate
 6 steps zoom from 34-60mm  comparison and review. Multiple TGC options for operator's
 Variable displaying area preference including

 5 sections adjustable TGC  vitreous-enhanced mode.

 Cineloop for 5.6sec  Editable clinical report with A-scan/IOL results, B-scan images,

 Accurate axial measurement under B-mode (SMI-5) and textual comments with configurable entries.
 Reports in PDF format for sharing and print-out.
 Manual correction of axial measurement under A-mode (SMI-5)
 Compatibility with graph/text printer.
 Multi-groups of calipers for distance measurement
 Diverse connections via HDMI and USB 2.0 ports.
 Measuring mode: contact and immersion
 HDMI interface for double-screen showcase.
 8 groups average with standard deviation (S.D.)
 DICOM 3.0 protocol available via USB 2.0 port.
 Save up to 50 groups of IOL calculation results
 Massive storage capacity for over 20,000 exams.
Technical Data B-Scan Enhanced Visibility and User-friendliness
B-Scan: A-Scan:  Image/video buffer slots for immediate click- and- -check,review and comparison.
Probe  Images/videos captured in real time and saved in lossless format ( .bmp & avi ).
10MHz Probe 10MHz with fixation red light
frequency  Zooming and scan depth adjustment for better ocular disease observation.
Scanning  Vitreous- Enhanced Mode improves visibility at vitreous body.
53° Resolution 0.01mm
angle A-Scan & IOL Calculation Enhancements and Tight Integration
Biometry  Biometry buffer slots for immediate click-and-check,review and comparison.
Resolution axial≤0.2mm, lateral≤0.4mm ≤±0.06mm
accuracy  Improved accuracy and reliability with Average and Standard Deviation for
Total gain ≥98dB adjustable Gain ≥98dB with an adjustable range of 0~59dB
 up to10 scans per exam.
34mm ~ 60mm, 6 steps Measuring
Zoom 15~39mm  6 popular IOL formulae and 5 Post-refractive IoL formulae available.
selectable range Full Reporting Capabilities
-30dB~0dB dynamic, 6 points Measuring anterior chamber depth, lens thickness, vitreous length
TGC  Full report integrating A-scan/IOL results.
manually adjustable parameters and axial length  B-scan images and doctor s comments.
5 different  With customized dictionary of symptom entries.
Variable delay automatic (for normal, dense cataract, aphakic and
0~15mm measuring
depth pseudophakic); manual Comprehensive Data Archiving and Management
modes  Simple UI allows users to load, search, print, etc..
4 groups of curves (linear,  Unlimited storage capacity for over 20,000 exams(8 lossless images per exam).
Post IOL power SRK/T, SRK-II, BINKHOST-II, HOLLADAY, HOFFER-Q
logarithmic, exponential,
processing calculation and HAIGIS
s-curve)
Gray scale 256 levels 8 groups average with standard deviation (S.D)
Dynamic replay for 5.6 sec, 56 images Save up to 50 groups of IOL calculation results and 4 groups of IOL
displayed continually or separately constants
Multi-groups of electronic calipers for distance measurement
Various area measurement

CHONGQING VISION STAR OPTICAL CO., LTD www.hyvisionstar.com


Ophthalmic A/B Scan
Technical Data
B-Scan
Ultrasound Probes 10MHz B-Scan Probe, 20MHz B-Scan Probe
Axial Resolution 10MH2 B-Scan: ≤ 0.1mm; 20MH2 B-Scan: ≤ 0.08mm
Lateral Resolution 10MHz B-Scan: ≤ 0.2mm; 20MHz B-Scan: ≤ 0.15mm
Scan Depth 10MHz: 28mm - 60mm; 20MHz: 19mm - 40mm,6-Step Selectable
Scan Angle 53°
Cineloop 10s/100 frames with dynamic replay
Image Acquisition B-Scan images , Snapped & Saved in real-time without any limitation
Gray Scale 256Levels
Gain 1-105dB adjustable
TGC Default
Vitreous- Enhanced Mode
Customized
B+A Mode AL Measurement
Color Codes 8
Measurements Distance, Area & Angle
A-Scan
Probe 10MHz with Fixation Red Light
Gain 1-60dB
Measuring Method Contact or Immersion
Measuring Range AL Range: 1 5mm-40mm
Measuring Accuracy ±0.05mm

CHONGQING VISION STAR OPTICAL CO., LTD www.hyvisionstar.com