Lionpak 9501

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

Flax fibre with water compatibility

for marine & general duties

Lionpak 9501 is a braided Typical applications


®

packing of tough flax fibre This packing is highly compatible with water. VALVE STEM DUTIES
impregnated with James Walker’s It is recommended for duties with stern glands,
rudder posts, water wheels, pumps and valves. Maximum Operating Temperature:
proprietary PTFE and
Suitable for use with river water, sea water, +100°C (+212°F)
oil-based dispersion. surface water, waste water and sewage. Minimum Operating Temperature:
-40°C (-40°F)
Prime features Chemical properties Maximum System Pressure:
• E
 conomical packing of tough flax Compatible with media in the range pH 5 -10. 10 MPa/100 bar (1450 psi)
fibre construction.
• Recommended for water duties.
How supplied
• Resistant to deformation. CENTRIFUGAL PUMPS
All popular square sections from 3 mm to 50 mm
• L
 ubrication package minimises scoring AND ROTARY EQUIPMENT
(1/8" to 2") in boxes containing 8 m (26’ 3”), in coil
of sleeves and shafts. form or on spools as detailed in the table below. Maximum Operating Temperature:
Also supplied as split preformed rings and sets. +100°C (+212°F)
Minimum Operating Temperature:

Spool ordering information -40°C (-40°F)


Maximum Shaft Speed:
Size Packaged ± 10%
3 m/s (591 fpm)
mm inch kg lbs Maximum System Pressure:
3.0 1/8 0.9 2 1 MPa/10 bar (145 psi)
5.0 3/16 0.9 2
6.5 1/4 0.9 2
RECIPROCATING PUMPS
8.0 5/16 0.9 2 AND RAMS
10.0 - 2.3 5 Maximum Operating Temperature:

11.0 7/16 2.3 5 +100°C (+212°F)


Minimum Operating Temperature:
12.5 1/2 2.3 5
-40°C (-40°F)
14.0 9/16 2.3 5 Maximum Rod Speed:

16.0 5/8 4.5 10 1.0 m/s (197 fpm)


Maximum System Pressure:
20.0 13/16 4.5 10
10 MPa/100 bar (1450 psi)
22.0 7/8 4.5 10
25.0 1 4.5 10
James Walker
Worldwide
Australia India Norway
T: +61 2 9721 9500 T: +91 224 0808080 T: +47 22 75 75 00
E: [email protected] E: [email protected] E: [email protected]

Belgium Ireland Singapore


T: +32 3 820 79 00 T: +353 214 323626 T: +65 6715 6300
E: [email protected] E: [email protected] E: [email protected]

Brazil Italy South Africa


T: +55 11 4392 7360 T: +39 2 2578308 T: +27 31 304 0770
E: [email protected] E: [email protected] E: [email protected]

China Middle East Spain & Portugal


T: +86 21 6876 9351 T: +971 481 78888 T: +34 94 447 00 99
E: [email protected] E: [email protected] E: [email protected]

France Netherlands UK
T: +33 437 49 74 80 T: +31 186 633111 T: +44 1270 536000
E: [email protected] E: [email protected] E: [email protected]

Germany New Zealand USA


T: +49 4038 60810 T: +64 9 272 1599 T: +1 708 754 4020
E: [email protected] E: [email protected] E: [email protected]

Health warning: If PTFE products are heated to elevated temperatures, fumes will be produced which may give unpleasant effects, if inhaled. Whilst some fumes are emitted
below 300°C (572°F) from PTFE, the effect at these temperatures is negligible. Care should be taken to avoid contaminating tobacco with particles of PTFE or PTFE dispersion,
which may remain on hands or clothing. Safety Data Sheets (SDS) are available on request.
Information given in this publication is given in good faith and represents the results of specific individual tests carried out by James Walker or third parties in accordance with the
methodologies described in this publication, performed in a laboratory. No representation or warranty is given in relation to such information. Values and/or operating limits given
in this publication are not an indication that these values and/or operating limits can be applied simultaneously. While such results may comprise useful additional information
and are industry standard tests, they are no substitute for conducting (or procuring from James Walker) your own tests and engineering analysis and satisfying yourself as to
the suitability of the product you select. Please also note that a product tested in accordance with the published methodology may not perform to such values in application
and/or under different test conditions or methodologies for a variety of reasons, including but not limited to the environment in which it is used/tested or which passes through it
or otherwise affects the product, or due to the handling, storage or installation, or due to the effect of housing or other parts. Our personnel will be happy to discuss any historical
examples we have of a product having been previously used in a particular application.
To ensure you are working with the very latest product specifications, please consult the relevant section of the James Walker website: www.jameswalker.biz.

James Walker Sealing Products & Services Ltd


Registered Office: Lion House, Oriental Road,
Woking, Surrey GU22 8AP, United Kingdom.
Reg no: 00264191 England

Issue number 2
© James Walker 2021 JW4735 0221/PDF

You might also like